[New instruments for preparation of the prosthesis socket and primary stability of the acetabular Press-fit cups].

The aim of the present study was to develop surgical instruments necessary to achieve a precisely reamed surface and stable initial fixation. The instruments used to prepare the socket were a gauge-drill guide, a liner for the spigot hole and two spigotted reamers of different design and indentation intended to achieve a precisely reamed surface while preserving subchondral bone. For each reamer we implanted in a synthetic hip model 10 uncemented cups with 2 mm press-fit and loaded at 2.4 kN in the physiological axis (Mod. 8501, Instron, Canton, MA, USA). The micromotion between implant and bone socket was measured using an inductive micrometric measuring system (MultiNCDT-500, Micro-Epsilon, Ortenburg, Germany) and compared with that seen after using conventional instruments. The use of the new reamer of elliptical design significantly reduced the standard deviations of the measured values (p < 0.01 at the ischium and pubis) and also reduced maximum movement (p < 0.01 at the ischium); at the same time, all the components showed overall limited movement (< 150 microns at the ischium, pubis and ilium) under maximum loading (2.4 kN). Manufacturing tolerances, the quality and wear of the instruments, acetabular bone stock and surgical technique all impact on the degree of press-fit obtainable at surgery. The results of our study show that press-fit and initial stability can be optimized by using adequate instruments to prepare the socket.

Acetabulum↗

Comparison of conventional instruments and mechanical debriders for surgery of patients with chronic sinusitis.

BACKGROUND: This article compares the use of the microdebrider as a form of powered instrumentation designed to decrease mucosal trauma with traditional surgical instruments for endonasal sinus surgery. METHODS: Surgery was performed with the shaver or conventional instruments using an endonasal approach in 24 patients with bilateral chronic rhinosinusitis. Each patient served as his/her own control, meaning that one side was operated on with conventional instruments and the opposite side was operated on with the microdebrider to evaluate postoperative recovery, healing, and incidence of complications. They were stratified preoperatively and reassessed during 3- and 6-month follow-up and long-term (mean, 13 month) follow-up visits, which included nasal endoscopy, saccharin transport time, assessment of mucociliary transport times and clinical symptoms. RESULTS: In this prospective randomized study we were unable to find a statistical difference (p > 0.05) in surgical outcome for patients when using either conventional instruments or mechanical debriders. CONCLUSION: In the literature, mechanical debriders are supposed to provide for mucosal preservation and faster healing. However, for surgical outcome, the use of microdebriders in our study was not better than the results at 3-, 6-, and at 13-month follow-up visits when compared with conventional instruments. Synechia formation, patency of middle meatal antrostomy, and ostial reocclusion were the same in both groups. The incidence of polxyposis as a sign of recurrent or persistent infection was similar. Functional results using the saccharin transport time, as a marker of mucociliary function, or episodes of recurrent purulent secretions, again, were identical.

Adult↗

Surgical application of a new robotic system for paranasal sinus surgery.

The applicability of a robotic system for fully automated surgical procedures approaching the sphenoid sinus is evaluated. An integrated robotic system, A73, for computer navigation-guided, fully automated, and telemanipulation robotic performance is described. Details of the system comprising newly designed surgical instruments for robotic operations and preoperative planning protocols are provided. Experiments with an operational accuracy of less than 1 mm were followed by surgical tests, in which the results of fully automated and telemanipulation performances on 5 cadaveric heads are seen. The A73 system has been successfully used for a reproducible and accurate resection of the anterior wall of the sphenoid sinus. Therefore, we conclude that this system is suited for further testing toward approaching fully automated and more complex procedures of paranasal surgery.

Cadaver↗

Cytoreductive Surgery in Ovarian Cancer: Why, When, and How?

Retrospective evidence supports the value of optimal cytoreductive surgery in the initial therapy of patients with advanced ovarian cancer. Specialized procedures, including radical pelvic surgery, bowel resection, and diaphragm resections, are frequently necessary to accomplish optimal cytoreduction. Cytoreduction and total gross tumor removal are possible more frequently with new surgical instruments such as the Cavitron ultrasonic surgical aspirator and argon beam laser. Pelvic and periaortic lymph node resection is an important aspect of cytoreductive surgery, and systematic removal of grossly uninvolved lymph nodes may improve survival. Secondary cytoreductive surgery appears to benefit a select group of patients.

Journal Article↗

[Methods to improve the delivery of hospital ophthalmological care to children in the Ukrainian SSR].

On the material of Children Eye Department the Filatov Institute, changes in the structure of eye pathology for the period of 1947-1989 are analysed. It is shown that for the last years, among all eye diseases, the incidence of inflammatory eye diseases fell to 7.5%. The incidence of eye traumas and their outcomes reaching 26.2% remained stable. The incidence of congenital pathology (35.4%) and new-formations in the eye (10.8%) with predominance of malignant tumors, complex pathology of oculomotor apparatus (23.5%) reached high values. Organization of centers, of ophthalmic microsurgery in children allowed to introduce into ophthalmological practice complex surgical interventions requiring special devices and instruments. Surgical activity of the Center of Ophthalmic microsurgery in Children on the basis of the Filatov Institute made up 84.5% in the last five years. In order to optimize the rendering of stationary ophthalmological aid to children, the authors consider it necessary to improve continuity between a microsurgical center and regional children eye hospitals, to increase qualification of children ophthalmologists, to create a Republic Center for Rehabilitation of Children with eye diseases on the basis of a sanatorium with a good ophthalmological equipment.

Child↗

Instrumentation for the dermatologic surgeon.

Because dermatologic surgery continues to enjoy widespread popularity as a leading treatment modality for skin disease, the skill and training of the surgeon are critical to patient care. Equally important, however, are the tools the surgeon uses to perform each particular procedure. Surgical instrumentation has often been a confusing subject for the novice surgeon, one in which personal preference often outweighs technical considerations. This article will present the advantages and short-comings of several instruments that constitute the basic armamentarium of the dermatologic surgeon.

Dermatologic Surgical Procedures↗

New variant CJD-BSE (mad cow disease). The need for disposable ENT instruments.

This paper outlines the development of Bovine Spongiform Encephalopathy (BSE) in the United Kingdom. The relationship between BSE and new variant Creutzfeldt-Jakob disease (vCJD) is considered and the risks of iatrogenic spread reviewed. The rationale for disposable surgical instruments in adenotonsillectomy to prevent iatrogenic spread is discussed.

Animals↗

Ultrasonic cleaning in the hospital.

Ultrasonic cleaning can prolong the life of expensive instruments. In the past, many fine instruments were discarded due to stiffening hinges and box locks, or sticking plungers. Hand scrubbing and spray washing could not thoroughly clean these areas. Ultrasonic cleaners effectively remove dried and baked blood, serums and medications from these instruments. Also, hinged instruments and syringes operate more smoothly during use in surgery when cleaned using ultrasonics. In addition, the use of ultrasonics alleviates the necessity for hand scrubbing of contaminated surgical instruments and laboratory apparatus, a procedure which could lead to injury or infection. The superb cleaning powers of ultrasonic cleaners, their speed and simplicity of operation, and their ability to remove blood, tissue, bacteria and microorganisms within minutes, makes them a valuable addition to any operating room suite, central service department, or emergency room. Their cost-effectiveness is considerable for the small hospital, and compelling for the large hospital.

Central Supply, Hospital↗

Medical applications of shape memory alloys.

Shape memory alloys (SMA) are materials that have the ability to return to a former shape when subjected to an appropriate thermomechanical procedure. Pseudoelastic and shape memory effects are some of the behaviors presented by these alloys. The unique properties concerning these alloys have encouraged many investigators to look for applications of SMA in different fields of human knowledge. The purpose of this review article is to present a brief discussion of the thermomechanical behavior of SMA and to describe their most promising applications in the biomedical area. These include cardiovascular and orthopedic uses, and surgical instruments.

Alloys↗

[Low-invasive colposuspension in stress enuresis in females].

Retropubic colposuspension (RC) is one of leading surgical treatments of stress enuresis in women. A low-traumatic method of RC with application of special surgical instruments is proposed. Retropubic urethrocervicopexy and low-invasive colposuspension were made in 27 and 17 women, respectively. 25 women have undergone endoscopic operations. Postoperative complications were minimal in endoscopic and low-invasive interventions. Long-term results were similar to literature data. Low-invasive colposuspension is an effective and low-traumatic treatment of stress enuresis in women.

Adult↗

[Biomechanical modeling of instrumentation for the scoliotic spine using flexible elements: a feasibility study].

Surgical instrumentation of the scoliotic spine is a complex procedure with many parameters, such as the spinal segment to operate on, the number and position of the hooks and screws, etc. Biomechanical modeling is a tool which can be used to determine the influence of these parameters. However, technical difficulties due to the large stiffness range of involved components and the large deformations associated with surgical maneuvers are encountered when using the finite elements method. Thus, the objective of this study is to adapt a modeling approach using analysis of flexible mechanisms and evaluate its feasibility. The model combines rigid bodies for the vertebrae and flexible elements representing intervertebral structures. The mechanical properties were calculated from published data and the geometry was personalized with intraoperative measurements. Following the installation of the hooks and screws on the modeled spine, two steps were used to simulate the surgical maneuvers: 1) translation and attachment of the hooks/screws on the first rod; 2) rod rotation. The feasibility of this modeling approach was evaluated by simulating the surgical maneuvers on 2 cases: 1) a physical model; 2) a clinical case. The agreement between intraoperative measurements and simulation results (frontal curvatures are reproduced with over 80% accuracy) shows the feasibility of the modeling approach. This approach also reduces computational convergence problems because of its limited sensitivity to stiffness differences between elements, which demonstrates the advantage of flexible mechanism modeling relative to finite element modeling. Long term goals of subsequent refinements are the development of a tool for surgical correction predictions and for the design of more efficient instrumentation.

Adolescent↗

[Evaluation of instrument improvements in oculomotor muscle surgery].

Five improvements of surgical instruments for strabismus-surgery are introduced; these are a small muscle-hook, a broad, flat muscle-hook, two variants of a retractor and one instrument for the resection or tucking of a rectus-muscle. All instruments have proved to be less traumatic and seem much safer than others even in less experienced hands. Most of them have been used over a period of more than 10 years in a specialized department.

Humans↗

Inexpensive retractors for laser operations.

The sterile tongue depressor and Lucite block have been presented as simple, safe and inexpensive retractors for use in laser operations. Such inexpensive devices are cost effective alternatives to blackened surgical instruments.

Carbon Dioxide↗

[Change in the properties of titanium alloys exposed to a stream of high-frequency, low-pressure radiating plasma].

The Nitrogen-Argon plasma of a high-frequency low-pressure discharge is proven to be very effective in machining pieces made of titanium alloys. The optimum operating modes are found that improve surface microhardness, reduce surface roughness, increase durability and endurance limits, and do not produce the effect on the residual stress. The operating modes have been tested with great success in machining microsurgical and ultrasonic surgical instruments.

Alloys↗

[H2O2 low temperature plasma sterilization. New possibilities for use with eye surgery instruments].

The H2O2-low-temperature-plasma-sterilization (STERRAD 100) works with a temperature below 50 degrees C (140 degrees F). This system is appliable for thermostabile materials as well as for thermolabile materials. The efficancy of this new system is shown by a biological test with Bacillus pumilus spores. 5 typical ophthalmic surgical instruments were contaminated. After sterilization the numerical reduction of the microorganisms had to be at least 6 log levels. Corrosion caused by hydrogene peroxide was excluded after exposing steal with a high quantity of this substrate. Electromicroscopy analysations of the surfaces of stainless steal after LTP, steam sterilization and hot-air sterilization are compared. Options and limitations of this new sterilization technique are discussed. A newly developed operating system with a complete instrumental box (OP-Set) will be introduced.

Bacillus↗

Two new forceps for use during and after dacryocystorhinostomy.

PURPOSE: To report two new forceps for use during and after external dacryocystorhinostomy (E-DCR). Description of surgical instruments is provided. METHODS: Interventional case series. The E-DCR forceps were modified from the usual ophthalmic forceps, and they were designed for grasping the posterior flaps in the narrow and deep surgical region. The washout forceps under the transnasal endoscopic (TNE) examination consists of the usual otolaryngeal forceps with an injector tip at the apex to wash out discharge around the ostium in the nasal cavity. RESULTS: In consecutive 28 E-DCR procedures cases (25 patients), E-DCR was successfully performed using the E-DCR forceps. This forceps was useful to suture the posterior flaps in all cases. The washout forceps was available to remove the congealed discharge that could not be aspirated. CONCLUSION: These two forceps proved to be useful during and after the E-DCR procedure.

Dacryocystorhinostomy↗

[Neurosurgery in antique medicine].

Trepanation and craniotomy are two of the oldest surgical procedures known, and extensive archaeological evidence of trepanation exists in ancient cultures. However, the first descriptions of the surgical techniques are from Greek and Roman medicine, where cranial surgery was used to treat head trauma. This article concerns neurosurgery in ancient medicine, with an emphasis on "De Medicina" by Aulus Cornelius Celsus (25 BC-50 AD) and the Corpus Hippocraticum (about 400 BC). These texts are further considered in the light of excavated surgical instruments from Pompeii.

Craniocerebral Trauma↗