Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “RADIO”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39Linked to original sources

Phosphorylation and gene expression of p53 are not affected in human cells exposed to 2.1425 GHz band CW or W-CDMA modulated radiation allocated to mobile radio base stations.

A large-scale in vitro study focusing on low-level radiofrequency (RF) fields from mobile radio base stations employing the International Mobile Telecommunication 2000 (IMT-2000) cellular system was conducted to test the hypothesis that modulated RF fields induce apoptosis or other cellular stress response that activate p53 or the p53-signaling pathway. First, we evaluated the response of human cells to microwave exposure at a specific absorption rate (SAR) of 80 mW/kg, which corresponds to the limit of the average whole-body SAR for general public exposure defined as a basic restriction by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines. Second, we investigated whether continuous wave (CW) and wideband code division multiple access (W-CDMA) modulated signal RF fields at 2.1425 GHz induced apoptosis or any signs of stress. Human glioblastoma A172 cells were exposed to W-CDMA radiation at SARs of 80, 250, and 800 mW/kg, and CW radiation at 80 mW/kg for 24 or 48 h. Human IMR-90 fibroblasts from fetal lungs were exposed to both W-CDMA and CW radiation at a SAR of 80 mW/kg for 28 h. Under the RF field exposure conditions described above, no significant differences in the percentage of apoptotic cells were observed between the test groups exposed to RF signals and the sham-exposed negative controls, as evaluated by the Annexin V affinity assay. No significant differences in expression levels of phosphorylated p53 at serine 15 or total p53 were observed between the test groups and the negative controls by the bead-based multiplex assay. Moreover, microarray hybridization and real-time RT-PCR analysis showed no noticeable differences in gene expression of the subsequent downstream targets of p53 signaling involved in apoptosis between the test groups and the negative controls. Our results confirm that exposure to low-level RF signals up to 800 mW/kg does not induce p53-dependent apoptosis, DNA damage, or other stress response in human cells.

Amino Acid Sequence↗

Assessment of the immune responsiveness of mice irradiated with continuous wave or pulse-modulated 425-MHz radio frequency radiation.

Groups of female BALB/C mice were irradiated with 425-MHz radio frequency (RF) radiation either continuous wave (CW) or pulse modulated (PM, 1-ms pulse width, 250 pulses/s). Mice were irradiated in a rectangular strip-transmission line at average forward powers of 78, 17.7, or 5 W for CW and 17.7, 5, or 1.25 W for PM. The mean specific absorption rate, as measured using twin-well calorimetry was 7.7 W/kg for a forward power of 70 W. No differences in the mitogen-stimulated response of lymphocytes or in the primary antibody response to sheep erythrocytes or polyvinylpyrrolidone were observed between irradiated and sham-irradiated mice, nor between mice exposed to either CW or PM 425-MHz RF radiation.

Animals↗

Specific absorption rate (SAR) in models of the human head exposed to hand-held UHF portable radios.

Specific absorption rate (SAR) was measured in models of the human head exposed to hand-held portable radios ("transceivers") transmitting at frequencies in the 800-MHz band. An isotropic implantable electric-field probe was used to measure internal fields induced in the head models, and SARs were determined by calculation. As well as determining representative values and distributions for SARs under various conditions, it was shown that antenna type and orientation with respect to the head are important factors affecting energy absorption.

Absorption↗

In vitro lymphocyte proliferation induced by radio-frequency electromagnetic radiation under isothermal conditions.

Whole human blood was exposed or sham-exposed in vitro for 2 h to 27 or 2,450 MHz radio-frequency electromagnetic (RF) radiation under isothermal conditions (i.e., 37 +/- 0.2 degrees C). Immediately after exposure, mononuclear cells were separated from blood by Ficoll density-gradient centrifugation and cultured for 3 days at 37 degrees C with or without mitogenic stimulation by phytohemagglutinin (PHA). Lymphocyte proliferation was assayed at the end of the culture period by 6 h of pulse labeling with 3H-thymidine (3H-TdR). Exposure to radiation at either frequency at specific absorption rates (SARs) below 50 W/kg resulted in a dose-dependent, statistically significant increase of 3H-TdR uptake in PHA-activated or unstimulated lymphocytes. Exposure at 50 W/kg or higher suppressed 3H-TdR uptake relative to that of sham-exposed cells. There were no detectable effects of RF radiation on lymphocyte morphology or viability. Notwithstanding the characteristic temperature dependence of lymphocyte activation in vitro, the isothermal exposure conditions of this study warrant the conclusion that the biphasic, dose-dependent effects of the radiation on lymphocyte proliferation were not dependent on heating.

Dose-Response Relationship, Radiation↗

Absence of a synergistic effect between moderate-power radio-frequency electromagnetic radiation and adriamycin on cell-cycle progression and sister-chromatid exchange.

In our laboratories we are conducting investigations of potential interactions between radio-frequency electromagnetic radiation (RFR) and chemicals that are toxic by different mechanisms to mammalian cells. The RFR is being tested at frequencies in the microwave range and at different power levels. We report here on the 1) ability of simultaneous RFR exposures to alter the distribution of cells in first and second mitoses from that after treatment by adriamycin alone, and 2) on the ability of simultaneous RFR exposure to alter the extent of sister chromatid exchanges (SCEs) induced by adriamycin alone. This chemical was selected because of its reported mechanism of action and because it is of interest in the treatment of cancer. In our studies, Chinese hamster ovary (CHO) cells were exposed for 2 h simultaneously to adriamycin and pulsed RFR at a frequency of 2,450 MHz and a specific absorption rate of 33.8 W/Kg. The maximal temperature (in the tissue-culture medium) was 39.7 +/- 0.2 degrees C. The experiments were controlled for chemical and RFR exposures, as well as for temperature. Verified statistically, the data indicate that the RFR did not affect changes in cell progression caused by adriamycin, and the RFR did not change the number of SCEs that were induced by the adriamycin, which adriamycin is known to affect cells by damaging their membranes and DNA.

Animals↗

Dose dependence of acetylcholinesterase activity in neuroblastoma cells exposed to modulated radio-frequency electromagnetic radiation.

Radio-frequency electromagnetic radiation (RFR) at 915 and 147 MHz, when sinusoidally amplitude modulated (AM) at 16 Hz, has been shown to enhance release of calcium ions from neuroblastoma cells in culture. The dose-response relation is unusual, consisting of two power-density "windows" in which enhanced efflux occurs, separated by power-density regions in which no effect is observed. To explore the physiological importance of these findings, we have examined the impact of RFR exposure on a membrane-bound enzyme, acetylcholinesterase (AChE), which is intimately involved with the acetylcholine (ACh) neurotransmitter system. Neuroblastoma cells (NG108), exposed for 30 min to 147-MHz radiation, AM at 16 Hz, demonstrated enhanced AChE activity, as assayed by a procedure using 14C-labeled ACh. Enhanced activity was observed within a time window between 7.0 and 7.5 h after the cells were plated and only when the exposure occurred at power densities identified in a previous report as being effective for altering the release of calcium ions. Thus RFR affects both calcium-ion release and AChE activity in nervous system-derived cells in culture in a common dose-dependent manner.

Acetylcholinesterase↗

Specific absorption rate levels measured in a phantom head exposed to radio frequency transmissions from analog hand-held mobile phones.

Electric fields (E-fields) induced within a phantom head from exposure to three different advanced mobile phone system (AMPS) hand-held telephones were measured using an implantable E-field probe. Measurements were taken in the eye nearest the phone and along a lateral scan through the brain from its centre to the side nearest the phone. During measurement, the phones were positioned alongside the phantom head as in typical use and were configured to transmit at maximum power (600 mW nominal). The specific absorption rate (SAR) was calculated from the in situ E-field measurements, which varied significantly between phone models and antenna configuration. The SARs induced in the eye ranged from 0.007 to 0.21 W/kg. Metal-framed spectacles enhanced SAR levels in the eye by 9-29%. In the brain, maximum levels were recorded at the measurement point closest to the phone and ranged from 0.12 to 0.83 W/kg. These SARs are below peak spatial limits recommended in the U.S. and Australian national standards [IEEE Standards Coordinating Committee 28 (1991): C95.1-1991 and Standards Australia (1990): AS2772.1-1990] and the IRPA guidelines for safe exposure to radio frequency (RF) electromagnetic fields [IRPA (1988): Health Phys 54:115-123]. Furthermore, a detailed thermal analysis of the eye indicated only a 0.022 degrees C maximum steady-state temperature rise in the eye from a uniform SAR loading of 0.21 W/kg. A more approximate thermal analysis in the brain also indicated only a small maximum temperature rise of 0.034 degrees C for a local SAR loading of 0.83 W/kg.

Absorption↗

Bone response to radio frequency sputtered calcium phosphate implants and titanium implants in vivo.

The objective of this study was to evaluate the effect of radio frequency sputtered calcium phosphate (CaP) coatings of titanium (Ti) implants on the bond strength at the bone-implant interface and percent bone contact length. Cylindrical coated or noncoated implants (4.0-mm diameter by 8-mm long) were implanted for 3 and 12 weeks. At 3 weeks after implant placement, the ultimate interfacial strengths for as-deposited CaP-coated and heat-treated CaP-coated implants were 2.29 +/- 0.14 MPa and 1.28 +/- 0.04 MPa, respectively. These ultimate interfacial strength values at 3 weeks were statistically greater than the mean ultimate interfacial strength for control Ti implants (0.67 +/- 0.13 MPa). At 12 weeks after implant placement, no statistical differences in the mean ultimate interfacial strengths were observed between the as-deposited CaP-coated, heat-treated CaP-coated, and control Ti implants. Histomorphometric evaluation indicated greater percent bone contact lengths for the as-deposited CaP-coated implants compared with the heat-treated CaP-coated and control Ti implants 3 and 12 weeks after implant placement.

Animals↗

Radio frequency hyperthermia of advanced human sarcomas.

Hyperthermia greater than or equal to 42 degrees C is tumoricidal in vitro and in many animal models, although such temperatures have only recently been achieved experimentally in some human cancers. A recently developed radio frequency device that provides safe hyperthermia to any depth without surface tissue injury now permits evaluation of the effects of hyperthermia on advanced human sarcomas. Twelve patients with large sarcomas located intraabdominally [7], in the chest wall [2], proximal extremity [2], and the neck [1], were evaluated in this study. Tumor types include liposarcoma [3], rhabdomyosarcoma [2], leiomyosarcoma [2], neurofibrosarcoma [2], and one each malignant mesothelioma, undifferentiated sarcoma, and osteosarcoma. Intratumor temperatures greater than or equal to 42 degrees C were observed in all tumors, with virtually no normal tissue injury. Selective tumor heating greater than or equal to 45 degrees C occurred in 9/12 (75%) and greater than or equal to 50 degrees C in 6/12 (50%). One to five weekly treatments greater than or equal to 50 degrees C and ten daily treatments greater than or equal to 45 degrees C resulted in significant tumor necrosis and pain relief in some patients. Hyperthermia of advanced sarcomas is possible with little host toxicity and may be of potential therapeutic benefit.

Adult↗

Shielded gradient coils and radio frequency probes for high-resolution imaging of rat brains.

A shielded gradient system and radio frequency probes for a 4.7-T/30-cm horizontal bore magnet are described. The systems were designed principally to obtain images and localized spectra from rat brains. The gradients can operate in either a shielded or non-shielded mode. The rf probe, which combines both highest sensitivity and highest resolution, consists of a large modified saddle type transmitter and a small surface reception coil, actively decoupled using diodes. The system performance is demonstrated on phantoms and on a rat brain, where an image with in plane resolution of 80 microns and a slice thickness of 150 microns is obtained.

Animals↗

Reduced power selective excitation radio frequency pulses.

A pulse synthesis algorithm is described that allows for the synthesis of selective radio frequency pulses requiring less peak power. The pulses thus synthesized have the same duration, total energy, and frequency response as those synthesized by the standard algorithm. Their phase function is, however, different. The power reduction is typically on the order of 60-70%. This modification will increase the utility of optimized selective pulses.

Algorithms↗

Effect of radio frequency inhomogeneity correction on the reproducibility of intra-cranial volumes using MR image data.

The volumes of total brain, white matter, gray matter, and cerebrospinal fluid in normal volunteers were determined using a supervised nonparametric feature map segmentation of dual-contrast MR images after correcting for the radio frequency (RF) inhomogeneity. Reproducibility of the segmentation was evaluated in terms of inter-observer and scan-to-scan variations. A comparison with the published results indicates that the scan-to-scan and inter-observer variabilities in the determination of tissue volumes are substantially reduced following the RF inhomogeneity correction.

Brain↗

Applications of a travelling wave-based radio-frequency-only stacked ring ion guide.

The use of radio-frequency (RF)-only ion guides for efficient transport of ions through regions of a mass spectrometer where the background gas pressure is relatively high is widespread in present instrumentation. Whilst multiple collisions between ions and the background gas can be beneficial, for example in inducing fragmentation and/or decreasing the spread in ion energies, the resultant reduction of ion axial velocity can be detrimental in modes of operation where a rapidly changing influx of ions to the gas-filled ion guide needs to be reproduced at the exit. In general, the RF-only ion guides presently in use are based on multipole rod sets. Here we report investigations into a new mode of ion propulsion within an RF ion guide based on a stack of ring electrodes. Ion propulsion is produced by superimposing a voltage pulse on the confining RF of an electrode and then moving the pulse to an adjacent electrode and so on along the guide to provide a travelling voltage wave on which the ions can surf. Through appropriate choice of the travelling wave pulse height, velocity and gas pressure it will be shown that the stacked ring ion guide with the travelling wave is effective as a collision cell in a tandem mass spectrometer where fast mass scanning or switching is required, as an ion mobility separator at pressures around 0.2 mbar, as an ion delivery device for enhancement of duty cycle on an orthogonal acceleration time-of-flight (oa-TOF) mass analyser, and as an ion fragmentation device at higher wave velocities.

Computer-Aided Design↗

Lethal and teratogenic effects of long-term low-intensity radio frequency radiation at 428 MHz on developing chick embryo.

Exposure of developing chick embryos to 428 MHz radio frequency (RF) radiation at a power density of 5.5 mW/cm2 for more than 20 days resulted in embryolethal and/or teratogenic effects and delayed hatching. These adverse biological effects were not due to any thermal effect of the RF radiation. We have demonstrated teratogenicity in the chick embryo as a result of protracted low-dose RF irradiation.

Abnormalities, Radiation-Induced↗

Investigations of low-amplitude radio frequency pulses at and away from rotary resonance conditions for I = 5/2 nuclei.

Additional experimental evidence of rotary resonance effects for multiple-quantum coherence conversion in a spin-5/2 system is presented. Two-dimensional plots of the relative efficiency of MQ excitation and conversion are given as a function of radio frequency (rf) amplitude and pulse width. Data are presented for the excitation of five-quantum coherence (5QC), as well as for 5QC to three-quantum coherence (3QC) conversion, 5QC to IQC (the central transition coherence) conversion, and 3QC to IQC conversion. A two-fold increase in the signal-to-noise ratio is achieved by substituting low amplitude rf pulses in place of hard rf pulses for 5QC excitation and 5QC to 3QC conversion in a mixed multiple-quantum magic angle spinning (MAS) (MMQMAS) experiment. The anisotropic line shape for the low-amplitude rf pulse version of the MMQMAS experiment was observed to be distorted from the MAS line shape. The cause and implications of the distortion are discussed.

Anisotropy↗

Prospective head motion compensation for MRI by updating the gradients and radio frequency during data acquisition.

Subject motion appears to be a limiting factor in numerous magnetic resonance imaging (MRI) applications. For head imaging the subject's ability to maintain the same head position for a considerable period of time places restrictions on the total acquisition time. For healthy individuals this time typically does not exceed 10 minutes and may be considerably reduced in case of pathology. In particular, head tremor, which often accompanies stroke, may render certain high-resolution 2D and 3D techniques inapplicable. Several navigator techniques have been proposed to circumvent the subject motion problem. The most suitable for head imaging appears to be the orbital or spherical navigator methods. Navigators, however, not only lengthen the measurement because of the time required for acquisition of the position information, but also require additional excitation radio frequency (RF) pulses to be incorporated into the sequence timing, which disturbs the steady state. Here we demonstrate the possibility of interfacing the MR scanner with an external optical motion tracking system, capable of determining the object's position with sub-millimeter accuracy and an update rate of 60Hz. The movement information on the object position (head) is used to compensate the motion in real time. This is done by updating the field of view (FOV) by recalculating the gradients and the RF-parameter of the MRI tomograph during the acquisition of k-space data based on the tracking data. Results of rotation phantom, in vivo experiments and the implementation in two different MRI sequences are presented.

Artifacts↗

The effects of radio-frequency lesions of the nucleus accumbens on d-amphetamine-induced locomotor and rearing behavior in rats.

A large body of evidence supports the conclusion that mesolimbic dopaminergic neurons, particularly those that innervate the nucleus accumbens (n. ACC), are important for the expression of amphetamine-stimulated locomotor behavior (ASLB). However, a contradictory report (Wirtshafter et al. 1978), stating that bilateral lesions of the n. ACC fail to block ASLB, was based on a general measure of activity that did not distinguish between locomotion and rearing. In the present study, observer ratings of videotaped responses were used to determine the separate effects of 2.0 mg/kg d-amphetamine (d-AMP) on locomotion and rearing in rats with either sham or radio-frequency lesions of the n. ACC. The n.ACC lesions blocked the locomotor stimulation, but not the increased rearing that follows d-AMP administration. These results support the general conclusion that dopaminergic terminals in the n. ACC are important for the expression of ASLB, and further suggest that d-AMP-stimulated locomotion and rearing are mediated through different neural substrates.

Animals↗

Use of radio-frequency pulsed energy in the control of postoperative reaction in blepharoplasty.

This is a preliminary report of the use of a device to apply small pulses of radio-frequency energy to surgical wounds in order to improve wound healing. The device was applied to one eye in 21 patients who underwent bilateral blepharoplasty. There were no device-related complications. In 11 patients, edema and ecchymosis were noticeably less on the treated side within 24 hours of surgery. In 6 patients, ecchymosis and swelling were so slight that no difference between treated and untreated sides was visible. Two patients were noticeably worse on the treated side. Further studies will be conducted.

Eyelids↗