Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “PRINTING”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39Linked to original sources

Evaluation of screen-printed gold on low-temperature co-fired ceramic as a substrate for the immobilization of electrochemical immunoassays.

Screen-printed gold (SPG, Dupont gold conductor 5734) on low-temperature co-fired ceramic (LTCC) materials (Dupont dielectric tape 951, mostly composed of alumina and silica) has been demonstrated to be a substrate for electrochemical enzyme-linked immunosorbant assays. The effect of two different cleaning treatments and the extent of nonspecific adsorption on the SPG/LTCC and plain LTCC surfaces were also evaluated. LTCC materials hold promise for constructing a new generation of devices for microelectrochemical sensing and assays. Facile fabrication in three dimensions with integrated conducting elements makes them attractive. A standard sandwich immunoassay for a model analyte, mouse IgG, was used to evaluate the LTCC materials. After the assembly of components onto chips of SPG/LTCC and plain LTCC, p-aminophenol that was generated enzymatically by the enzyme label was detected electrochemically with a separate glassy carbon electrode. Cleaning SPG/LTCC with a piranha solution (7:1 vol/vol of concentrated H2SO4/30% H2O2), traditionally used for other gold surfaces prior to SAM assembly, resulted in a notable decrease in assay signal and an increase in nonspecific adsorption when compared to cleaning with water alone. Assay components assemble specifically on plain LTCC, with only a small percent attributed to NSA. Environmental scanning electron microscopy, energy-dispersive X-ray spectroscopy, and X-ray photoelectron spectroscopy reveal the tremendous chemical heterogeneity and complexity of both SPG/LTCC and plain LTCC surfaces and aid in the explanation of assay results. A 10% acetate Tween bovine serum albumin solution and an ethanolic solution of 4 mM 1-butanol eliminate assay signals originating from plain LTCC. The outcomes of these studies can now be used to achieve miniaturized electrochemical immunoassays on LTCC materials where both plain and SPG surfaces are present.

Adsorption↗

Manufacture of biomaterials by a novel printing process.

Tricalcium phosphate (TCP) scaffolds with controlled internal porosity were fabricated with a suspension of TCP in diacrylate cross-linking monomers using a mold prepared by ink-jet printing. Scaffolds were removed by selective dissolution of the mold. They were heat treated for removal of the acrylic binder followed by sintering. Despite a considerable linear shrinkage, scaffold porosity was retained after sintering. Composite scaffolds were fabricated from TCP in poly(ethylene glycol) diacrylate using an identical gel casting route.

Journal Article↗

Noise pollution in textile, printing and publishing industries in Saudi Arabia.

A study of 20 factories belonging to textile, printing, publishing and paper products industries in Jeddah was conducted. Data on Leq, Maximum and Minimum SPL at different octave bands, as well as dBA, were collected. It has been found that textile, publishing and paper products industries are the most noisy industries. The paper is concluded with suitable recommendation for noise control and worker protection.

Humans↗

An exercise in improving suicide reporting in print media.

This study was conducted to support the publication of guidelines for media reporting on suicide. First, quantitative and qualitative aspects of suicide reporting in Swiss print media were surveyed over a time span of 8 months. The results were presented at a national press conference, and written guidelines for suicide reporting were sent out to all newspaper editors. The results of the survey and the guidelines were discussed in a personal meeting with the Editor-in-Chief of the main tabloid. After the publication of the guidelines a second, identical survey was conducted. The main variables regarding frequency, form, and content of the newspaper reports before and after the press conference were compared. The number of articles, on the one hand, increased over the 3 years between the first and second survey, but the quality of reporting clearly improved on the other. The personal contact with the editor of the tabloid was probably the most effective means of intervention.

Guidelines as Topic↗

Clinical examinations to validate self-completion questionnaires: dermatitis in the UK printing industry.

A self-completion questionnaire sent to 2600 Nottinghamshire members of the Graphical Paper and Media Union elicited a 62% response. Forty one per cent of respondents reported suffering a skin complaint at some time and 11% had a current skin problem on the hand. This paper reports the validation stage of the study. Samples of 45 'cases' of self-reported dermatitis and 60 'controls', who reported they had never suffered a skin complaint, were clinically examined. All 45 self-reported cases were clinically confirmed as dermatitis. Occupationally related irritant contact dermatitis (ICD) was diagnosed in 20 (44%); 26 (58%) complaints were thought to be induced or exacerbated by occupation. Of the controls, 21 (35%) were also diagnosed with a skin complaint, the majority being mild, with an occupational association in 17, the majority (15) being ICD. Sixteen ICD cases were patch tested resulting in positive reactions to colophony, neomycin, nickel and potassium dichromate (2 of each). Two cases of basal cell carcinoma on the face were also identified, of which the participants were unaware. Although there was no false positive self-reporting there was a considerable number of false negatives, demonstrating the importance of clinical validation of questionnaires relating to industrial skin disease. This study has highlighted the need for improvement in skin care provision in the printing industry.

Adult↗

Predicting reading performance from neuroimaging profiles: the cerebral basis of phonological effects in printed word identification.

This study linked 2 experimental paradigms for the analytic study of reading that heretofore have been used separately. Measures on a lexical decision task designed to isolate phonological effects in the identification of printed words were examined in young adults. The results were related to previously obtained measures of brain activation patterns for these participants derived from functional magnetic resonance imaging (fMRI). The fMRI measures were taken as the participants performed tasks that were designed to isolate orthographic, phonological, and lexical-semantic processes in reading. Individual differences in the magnitude of phonological effects in word recognition, as indicated by spelling-to-sound regularity effects on lexical decision latencies and by sensitivity to stimulus length effects, were strongly related to differences in the degree of hemispheric lateralization in 2 cortical regions.

Adult↗

Relation between pronunciation and recognition of printed words in deep and shallow orthographies.

The processes responsible for recognition and pronunciation of printed words were studied by means of lexical decision and naming experiments. Two languages were examined: English, which has a complex and deep correspondence between spelling and speech, and Serbo-Croatian, in which the correspondence is simple and direct. It was hypothesized that reliance on articulatory coding (instead of on mediation by the internal lexicon) would be greater for Serbo-Croatian because its shallow orthography would allow more efficient use of spelling-to-speech correspondences. Each target stimulus was preceded by a word that was either related or unrelated semantically. Semantic priming of target words facilitated performance in both lexical decision and naming for English, results suggesting an influence of the internal lexicon on both processes. In contrast, semantic priming facilitated only lexical decision for Serbo-Croatian, which suggests that naming, at least in that language, is not strongly influenced by the internal lexicon. Further, in Serbo-Croatian, lexical decision and naming latencies were correlated when both tasks were not semantically primed and were uncorrelated when either or both tasks received semantic priming. This suggested that articulatory coding is used in lexical decision, at least under conditions in which contextual semantic facilitation is absent. In contrast, in English, lexical decision and naming were correlated uniformly whether semantic facilitation was present or not, which, when considered with the effect of semantic facilitation on naming, suggested a stronger influence of the internal lexicon on both recognition and pronunciation.

Form Perception↗

The topography of amphetamine and scopolamine-induced hyperactivity: toward an activity print.

The increased locomotor activity induced by systemic injections of d-amphetamine or scopolamine in rats was studied in Digiscan Animal Activity Monitors. This multifactorial analysis of locomotion demonstrated that activity measures of horizontal (ambulatory), vertical (rearing), stereotypic, and rotational behaviors differed depending on dose and drug. The topographies of these activity variables may be unique for the dopaminergic and cholinergic systems underlying hyperactivity. These results are a first step toward a needed increase in the sophistication of behavioral pharmacological techniques, allowing for the development of specific activity prints for different classes of psychoactive agents.

Animals↗

Letter position information and printed word perception: the relative-position priming constraint.

Six experiments apply the masked priming paradigm to investigate how letter position information is computed during printed word perception. Primes formed by a subset of the target's letters facilitated target recognition as long as the relative position of letters was respected across prime and target (e.g., "arict" vs. "acirt" as primes for the target "apricot"). Priming effects were not influenced by whether or not absolute, length-dependent position was respected (e.g., "a-ric-t" vs. "arict"/"ar-i-ct"). Position of overlap of relative-position primes (e.g., apric-apricot; ricot-apricot; arict-apricot) was found to have little influence on the size of priming effects, particularly in conditions (i.e., 33 ms prime durations) where there was no evidence for phonological priming. The results constrain possible schemes for letter position coding.

Attention↗

Organic materials for printed electronics.

Organic materials can offer a low-cost alternative for printed electronics and flexible displays. However, research in these systems must exploit the differences - via molecular-level control of functionality - compared with inorganic electronics if they are to become commercially viable.

Journal Article↗

Screen-printed amperometric biosensors for the rapid measurement of L- and D-amino acids.

Screen-printed three-electrode amperometric sensors incorporating L- and/or D-amino acid oxidase for the general purpose measurement of L- or D-amino acids is described. The working electrode incorporates rhodinized carbon, to facilitate hydrogen peroxide oxidation at a decreased operating potential, and immobilized enzyme. The devices responded to all 20 common L-amino acids and all of the D-amino acids examined, the exceptions being L- and D-proline. Linear response profiles were observed for L-leucine, L-glycine and L-phenylalanine with limits of detection of 0.47, 0.15 and 0.20 mM respectively. The devices were reproducible and exhibited stability over a 56 d test period. The biosensor compares favourably with a standard photometric amino acid test and was used to monitor milk ageing effects. The assay is cheap, simple to perform and rapid, requiring only buffer-electrolyte and a small sample volume.

Amino Acids↗

Novel, reagentless, amperometric biosensor for uric acid based on a chemically modified screen-printed carbon electrode coated with cellulose acetate and uricase.

Amperometry in stirred solution has been used for the systematic evaluation of modified screen-printed carbon electrodes (SPCEs) with a view to developing a reagentless biosensor for uric acid. The developed system consists of a base cobalt phthalocyanine (CoPC) electrode tailored to the electrocatalytic oxidation of H2O2 by means of a cellulose acetate (CA)-uricase bilayer. Uricase was immobilized by drop-coating the enzyme onto the CA membrane covering the CoPC-SPCE. The device exploits the near-universal H2O2-generating propensity of oxidases, the permselectivity of the CA film towards H2O2 and the electrocatalytic oxidation of this product at the CoPC-SPCE. The electrochemical oxidation of the resulting Co+ species was used as the analytical signal, facilitating the application of a greatly reduced operating potential when compared with that required for direct oxidation of H2O2 at unmodified electrodes. The time required to achieve 95% of the steady-state current (t95i(ss)) was 44 s [relative standard deviation = 7.5% (n = 10)]. Amperometric calibrations were linear over the range from 13 x 10(-6) to 1 x 10(-3) mol dm-3, with the former representing the limit of detection. The CA membrane extended the linear range of the biosensor by over two orders of magnitude, when apparent Michaelis-Menten constants (Km') of immobilized and free enzymes are compared. This suggests that the process is diffusion-controlled and not governed by the kinetics of the enzyme. The precision of electrode fabrication was determined by cyclic voltammetry to be 4.9% (n = 6).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Effect of pre-treatment on the surface and electrochemical properties of screen-printed carbon paste electrodes.

The effect of various electrochemical pre-treatment methods on the surface and electrochemical properties of screen-printed carbon paste electrodes (SPCE) prepared with three different commercial products was examined. It was observed that a positively charged redox couple, e.g., hexaammineruthenium(III), exhibited quasi-reversible behavior at the untreated SPCE. However, the cyclic voltammograms (CVs) of the SPCE prepared with general-purpose carbon inks did not exhibit clear redox peaks to other representative redox couples [e.g., hexacyanoferrate(III), hexachloroiridate(IV), dopamine, and hydroquinone] without activation. Electrochemical pre-treatment methods were sought in four different aqueous solutions, i.e., sulfuric acid, potassium chloride, sodium hydrogencarbonate, and sodium carbonate, applying various activation potentials. It was found that the pre-treatment procedure in saturated Na2CO3 solution at 1.2 V provides a mild and effective condition for activating the SPCE. By measuring the water contact angles at the SPCE surfaces and recording their SEM images, it was confirmed that the electrochemical pre-treatment effectively removes the organic binders from the surface carbon particles. A prolonged period of activation (> 5 min) or the use of high potentials (> 1.2 V) increased the capacitance of the electrode over 20 microF cm(-2). The pre-treated SPCE behaved like a random array microelectrode, exhibiting a sigmoidal-shaped CV at a slow scan rate. The short pre-anodization method in Na2CO3 solution was generally applicable to most SPCE prepared with general-purpose carbon inks.

Journal Article↗

An assay for the enzyme N-acetyl-beta-D-glucosaminidase (NAGase) based on electrochemical detection using screen-printed carbon electrodes (SPCEs).

An electrochemical assay for the enzyme N-acetyl-beta-D-glucosaminidase (NAGase) is described, using bare screen-printed carbon electrodes (SPCEs). The enzyme substrate, 1-naphthyl-N-acetyl-beta-D-glucosaminide, was added to the NAGase-containing sample under hydrodynamic conditions and was hydrolysed to 1-naphthol, which was monitored amperometrically at an Eapp of +650 mV versus SCE. A pH study revealed the apparent Vmax for the assay to occur at pH 4.5. corresponding to an apparent substrate Km of 0.28 mM. In order to be compatible with the analysis of biological fluids, a final operating pH of 5.4 was selected, and, using a data recording time of 100 s post-substrate addition, the assay gave a linear response (r2 = 0.988) over the range 3.1 to 108 mU ml(-1) NAGase (RSD = 15.4%). This assay has the potential to monitor NAGase levels in a number of application areas.

Acetylglucosaminidase↗

Towards the development of molecularly imprinted polymer based screen-printed sensors for metabolites of PAHs.

This paper describes the fabrication of a sensor for 1-hydroxypyrene (1-OHP) based on a screen-printed carbon electrode (SPCE) modified with a molecularly imprinted polymer (MIP); 1-OHP was chosen as a model metabolite of polyaromatic hydrocarbons (PAHs). It was shown that 1-OHP could be readily oxidised at a plain SPCE and the electrochemical mechanism was found to involve an ECE (electron transfer-chemical reaction-electron transfer) process. The MIP for 1-OHP was prepared using only divinylbenzene (DVB) and styrene as monomers and the binding was only based on hydrophobic interactions. Batch binding studies revealed that optimum uptake of 1-OHP by the MIP occurred from solutions containing 35% water in methanol. Selectivity of the binding sites in the MIP was examined by performing uptake studies in the same solution containing either phenol or 1-naphthol; the specific binding of 1-OHP was twenty times greater than the former and five times greater than the latter. Preliminary calibration studies were performed with the MIP-SPCE using a two-step approach; accumulation was carried out in 35% water in methanol followed by measurement in 50% methanol-0.025 mol dm(-3) phosphate buffer pH 12. This two-step non-competitive affinity assay gave encouraging results and indicated potential for use in pollution studies.

Journal Article↗

Low-flow active and passive sampling of VOCs using thermal desorption tubes: theory and application at an offset printing facility.

While air sampling techniques using adsorbent-based collection, thermal desorption and chromatographic analysis have found a niche in ambient air sampling, occupational applications have been more limited. This paper evaluates the use of thermal desorption techniques for low flow active and passive sampling configurations which allow conveniently long duration sampling in occupational settings and other high concentration environments. The use of an orifice enables flows as low as 0.5 ml min(-1) and sampling periods up to several days without significant biases. A model is used to predict sampling rates of a passive sampler encompassing an orifice, a void space, glass wool, and the adsorbent. Laboratory and field tests conducted at a commercial offset printing facility, which contained a variety of volatile organic compounds (primarily aromatic but also a few chlorinated and terpene compounds at levels from 1 to 67,000 microg m(-3)), are used to evaluate the approach. Tenax GR and Carbosieve SIII, both singly and together, were employed as adsorbents. Side-by-side tests comparing high flow, low flow and passive samplers show excellent agreement and high linearity (r = 0.95) for concentrations spanning nearly five orders of magnitude. Active samplers were tested at flows as low as 0.5 ml min(-1), compared to typical flows up to 40 ml min(-1). Passive samplers demonstrated a linear range and agreement with predictions for adsorbate loadings from approximately 1 ng to nearly 10 microg. Using a chemical mass balance receptor model, concentrations in the facility were apportioned to solvents, inks and other indoor and outdoor sources. Overall, the use of low flow active and passive sampling approaches employing thermal desorption techniques provides good performance and tremendous flexibility that facilitates use in many applications, including workplace settings.

Adsorption↗

Analysis of erythromycin and tylosin in bovine muscle using disposable screen printed electrodes.

A disposable electrochemical enzyme-linked immunosorbent assay (ELISA) for the detection of two macrolides (erythromycin and tylosin) in bovine muscle was developed using a screen printed electrode (SPE) system as a differential pulse voltammetry (DPV) transducer with mouse anti-erythromycin (and anti-tylosin) monoclonal antibodies (MAb) serving as molecular recognition elements. The immunochemical system makes use of the competition assay principle, and employs an erythromycin (or tylosin)-BSA conjugate as coating molecule. After competition between free and coated analyte for the antibodies, the activity of the alkaline phosphatase labelled antiglobulins was measured electrochemically using 1-naphthylphosphate as substrate. Using standard solutions of erythromycin and tylosin, the detection limit of the assay was 0.2 ng mL(-1) determined to be for erythromycin and 2.0 ng mL(-1) for tylosin, while the sensitivity (25% inhibition concentration) was 1.0 ng mL(-1) for erythromycin and 3.0 ng mL(-1) for tylosin. The suitability of the assay for quantification of erythromycin and tylosin in bovine muscle was also studied. Spiked and real samples were analysed using the immunosensor system developed here. The ELISA showed precision values (relative standard deviation, RSD%) ranging from 4 to 9% for erythromycin and from 8 to 15% for tylosin; the accuracy (relative error, RE%) ranged from -11 to 6% and from -4 to 12% for erythromycin and tylosin, respectively. Results obtained on real samples were confirmed by micro-liquid chromatography coupled on line with tandem mass spectrometry (micro-LC-MS-MS), using an atmospheric pressure ionisation (API) source and an ionspray (IS) interface. The latter provides unequivocal identification and quantification of the analytes at the level of interest.

Animals↗