Thermoluminescence dosimetry of a thermal neutron field and comparison with Monte Carlo calculations.

The characteristics of thermoluminescence dosemeters (TLDs) regarding the determination of photon and neutron absorbed doses were investigated in a thermal neutron beam. Harshaw TLD-100 (LiF:Mg,Ti) and TLD-700 (7LiF:Mg,Ti) were compared with similar materials from Solid Dosimetric Detector and Method Laboratory (People's Republic of China). Harshaw TLD-700H (7LiF:Mg,Cu,P) and aluminium oxide (Al2O3:Mg,Y) from Hungary were also considered for photon dose measurement. The neutron sensitivity of the investigated materials was measured and found to be consistent with values reported by other authors. A comparison was made between the TL dose measurements and results obtained via conventional methods. An agreement within 20% was obtained, which demonstrates the ability of TLD for measuring neutron and photon doses in a mixed field, using careful calibration procedures and determining the neutron sensitivity for the usage conditions.

Aluminum Oxide↗

Energy response of LiF and Mg2SiO4 TLDs to 10-150 keV monoenergetic photons.

Energy response of LiF:Mg,Ti, LiF:Mg,Cu,P and Mg2SiO4:Tb thermoluminescence dosemeters (TLDs) was measured in the range 10-150 keV for monoenergetic photons at SPring-8 of an 8-GeV synchrotron radiation facility. The photon beam was monitored by a parallel-plate free-air ionisation chamber calibrated with an uncertainty of 3%. Owing to the small dimension of the beam, a rotating holder was designed in order to irradiate TLDs uniformly. The measured responses of LiF to energy were approximately in agreement with the calculated dose absorption dependence in the soft tissue. However, two types of LiF TLDs presented the different luminescent responses to the photon energy. The response of LiF:Mg,Ti had a smooth curve, and that of LiF:Mg,Cu,P presented a local maximum at 30 keV and a local minimum at 100 keV. The Mg2SiO4:Tb response was nearly bone equivalent. Linearity of dose responses was also confirmed up to 2 Gy on each TL material.

Dose-Response Relationship, Radiation↗

The dose-response of Harshaw TLD-700H.

Harshaw TLD-700H (7LiF:Mg,Cu,P) was previously characterised for low- to high-dose ranges from 1 microGy to 20 Gy. This paper describes the studies and results of dose-response and linearity at much higher doses. TLD-700H is a near perfect dosimetric material with near tissue equivalence, flat energy response, and the ability to measure beta, gamma and X rays. These new results extend the applicability of Harshaw TLD-700H into more dosimetric measurement environments. The simple glow curve structure provides insignificant fade, eliminating special oven preparation methods experienced by other materials. The work presented in this paper quantifies the performance of Harshaw TLD-700H in extended ranges.

Computer Simulation↗

Energy response of a two-dimensional sheet-type LiF:Mg,Cu,P TL dosemeter to photons.

A 2-D tissue-equivalent sheet-type dosemeter (NTL sheet) was developed using thermoluminescent material of LiF:Mg,Cu,P (NTL-250). The energy responses of the NTL sheet and NTL-250 powder were measured with 10-150 keV monoenergetic photons from synchrotron radiation at SPring-8. The sample was irradiated by a rotational method for the uniform irradiation with the narrow beam. Linearity of the NTL-250 was confirmed up to 2 Gy. Energy responses of the NTL sheet and NTL-250 powder were close to that of soft tissue. On the other hand, the BaSO(4) sheet, which has been used practically, showed the response that the sensitivity approximately 60 keV was 100 times higher than that for (60)Co gamma rays. Therefore the NTL sheet can be said to have excellent properties for dose measurements.

Copper↗

LiF:Mg,Cu,P glow curve shape dependence on heating rate.

The glow curve shape of LiF:Mg,Cu,P (MCP) material is studied in this research. The study is focused on the effects of the heating rate on the dosimetric peaks. Different configurations of dosemeters (chips, cards and powder) are studied. The shifting of the dominant dosimetric peak is observed and analysed. The curves are deconvoluted using the new Harshaw Glow Curve Analyser (GCA) program. Results of the study are presented, as well as possible explanations as to the observed effects.

Computer Simulation↗

Time-resolved spectroscopy of LiF:Mg,Cu,P.

Time-resolved spectroscopy measurements of LiF:Mg,Cu,P luminescence are presented to obtain a better understanding of the emission characteristics of this material. The intensities and decay of the emission bands were studied as a function of annealing temperature and ionising radiation (gamma) dose. Two peaks in the emission were observed at 367 and 466 nm when excited by the 266 nm laser radiation. The luminescence spectrum under band-to-band X-ray excitation shows a dominant emission approximately 390-400 nm, which resembles the reported thermoluminescence emission and is clearly different from the spectrum obtained using the 266 nm pulsed laser excitation. Annealing of the material to 300 degrees C increases the intensity of the 367 and 466 nm emission bands by an order of magnitude as well as changes the relative intensity of the bands. Additional emission bands, which are not evident in the thermoluminescence emission spectra, are seen at longer wavelengths that also increase with dose. Possible explanations for the observed emission spectra are discussed in this paper.

Computer Simulation↗

Comparison of two extremity dosemeters based on LiF:Mg,Cu,P thin detectors for mixed beta-gamma fields.

Two types of thin LiF:Mg,Cu,P detectors, GR-200F and MCP-Ns, have been characterised for use in the design of an extremity dosemeter for mixed beta-photon radiation fields. Both detectors consist of an extremely thin layer of sensitive material with effective thicknesses of 5 and 8 mg cm(-2), respectively, held in a 5 mg cm(-2) PVC ring holder. Dosimetric performance was analysed according to the ISO 12794 standard and compared with 240 mg cm(-2) TLD-100 measurements. In particular, the energy response was obtained for ISO narrow X-ray spectra, (137)Cs, (60)Co, (204)Tl and (90)Sr/(90)Y. From these measurements a mean calibration factor was calculated to estimate H(p)(0.07). Subsequently, the performance of the dosemeters was checked for a set of 10 different mixed photon and beta-photon fields. The study shows that the proposed dosemeters can estimate H(p)(0.07) in a wide range of mixed beta-photon fields with a maximum deviation from the given dose of 30% and an overall uncertainty of the order of 25% (k = 1). However, the results also highlight a large variability among the different thin detectors and, thus, the standard TLD-100 material is recommended whenever the workplace does not include low-energy beta radiation.

Beta Particles↗

Theoretical and experimental investigation of the f(D)max-(S/S0)max anomaly in LiF:Mg,Ti.

Previous investigations in the framework of the Unified Interaction Model (UNIM) have demonstrated the difficulty in theoretically predicting both f(D)max and [S(Ds)/S(0)]max with the same set of UNIM parameters. This anomaly is re-investigated and an alternative explanation, based on experimental measurements combined with UNIM analysis, is given. This explanation is based on the assumption that N(LC), the total number of available luminescent centres is changed by the sensitisation dose or anneal or both. Allowing N(LC) to increase as the sensitisation dose is increased, a good fit to both f(D) and S(Ds)/S0 is obtained.

Artifacts↗

Optical excitation of LiF:Mg,Ti following alpha and beta irradiation.

It is demonstrated experimentally that optical excitation of irradiated LiF:Mg,Ti (TLD-100) by 4 eV photons has the same effect for both alpha particle (high-ionisation density) irradiation and photon/electron irradiation. In both cases, peak 5a converts to peak 4 causing peak 4 to increase following the bleach. Such an observation is consistent with the major premise of track structure theory that radiation effects following heavy changed particle (HCP)/neutron irradiation are due exclusively to the interaction of the secondary electrons created by the HCP slowing down.

Alpha Particles↗

Thermoluminescence emission spectra for the LiF:Mg,Cu,Na,Si thermoluminescent materials with various concentrations of the dopants (3-D measurement).

The thermoluminescence (TL) emission spectra from LiF TL materials, called KLT-300 (LiF:Mg,Cu,Na,Si) with various dopant concentrations are measured and analysed. These KLT-300 materials were developed by the Korea Atomic Energy Research Institute (KAERI) to achieve an enhancement of the thermal stability in TL readings. Six types of samples are prepared with different dopant concentrations in the following ranges; Mg (0-0.20 mol%), Cu (0-0.05 mol%), Na and Si (0-0.9 mol%). The spectra measurements are carried out for the six types of samples using a TL emission spectra measurement device. The spectra measurement device consists of a monochromator, photomultiplier tube and temperature control unit to thermally stimulate the samples. The measured data shows the light emission during heating of the sample as a function of temperature and wavelength (three-dimensional TL spectra). The spectra were analysed using a method of deconvolution based on gaussian curve. The wavelength of a main peak of the emission spectra changes depending on the existence of the Cu dopant, while intensity of the spectra rapidly changes with the Cu dopant concentrations. The 385 nm emission is mainly observed in all the spectra from the samples with the Cu dopant, but in those from the samples without the Cu dopant a very weak 401 nm emission is mainly observed. However, any change in the wavelength at a main peak of the TL emission spectra from the sample materials with Na and Si dopants is not observed but that in the intensity at a peak of the spectra is observed.

Combinatorial Chemistry Techniques↗

Search for ionisation density effects in the radiation absorption stage in LiF:Mg,Ti.

Optical absorption (OA) dose-response of LiF:Mg,Ti (TLD-100) is studied as a function of electron energy (ionisation density) and irradiation dose. Contrary to the situation in thermoluminescence dose-response where the supralinearity is strongly energy-dependent, no dependence of the OA dose filling constants on energy is observed. This result is interpreted as indicating a lack of competitive process in the radiation absorption stage. The lack of an energy dependence of the dose filling constant also suggests that the charge carrier migration distances are sufficiently large to smear out the differences in the non-uniform distribution of ionisation events created by the impinging gamma/electron radiation of various energies.

Computer Simulation↗

Properties of the 4.45 eV optical absorption band in LiF:Mg,Ti.

The optical absorption (OA) and thermoluminescence (TL) of dosimetric LiF:Mg,Ti (TLD-100) as well as nominally pure LiF single crystal have been studied as a function of irradiation dose, thermal and optical bleaching in order to investigate the role of the 4.45 eV OA band in low temperature TL. Computerised deconvolution was used to resolve the absorption spectrum into individual gaussian bands and the TL glow curve into glow peaks. Although the 4.45 eV OA band shows thermal decay characteristics similar to the 4.0 eV band its dose filling constant and optical bleaching properties suggest that it cannot be associated with the TL of composite peaks 4 or 5. Its presence in optical grade single crystal LiF further suggests that it is an intrinsic defect or possibly associated with chance impurities other than Mg, Ti.

Computer Simulation↗

Measurements of the optical density and the thermoluminescent response of LiF:Mg,Ti exposed to high doses of 60Co gamma rays.

The absorption spectra and glow curves of LiF:Mg,Ti exposed to high doses of 60Co gamma rays as well as the optical density curves and thermoluminescent (TL) response as a function of dose were measured. Absorption peaks around 442 nm (2.8 eV), 307 nm (4.0 eV) and 248 nm (5.0 eV) were observed. The optical density is a linear function of dose up to 2500 Gy and then sublinear for the 5.0 eV band, and for the 4.0 eV band it is sublinear with a filling constant of 2.1 x 10(-4) and 6.2 x 10(-4) Gy(-1). The dose response of the 2.8 eV band is linear from 2500 Gy to 10 kGy with a slope of 1.0 x 10(-5) Gy(-1). Once the absorption spectra were obtained, the glow curves and the TL response were obtained. In the dose range, 290-10,000 Gy, the TL response of peaks 5 and 7 was supralinear-sublinear.

Cobalt Radioisotopes↗

Low temperature radioluminescence of LiF:Mg,Cu,P.

Low temperature radioluminescence spectra of LiF, variously co-doped with Mg, Cu and P, show highly unusual temperature dependencies which resemble thermoluminescence data. The signals include intense peaks and a relatively weak continuous background. One peak occurs below 30 K, together with a major peak near 125 K. The signals are highly sensitive to the dopants and slightly sensitive to X-ray dose rate. The role of donor acceptor pairs and the perturbations from intrinsic defects formed by ionisation can be used to describe all the observations. The 290 nm emission band is linked to H center annealing.

Copper↗

On neutron-gamma mixed field dosimetry with LiF:Mg,Ti at radiation protection dose levels.

The possibility of using the specific responses of the high temperature Peaks 6 and 7 and Peaks 4 and 5 to different LET radiations was mentioned in the past mainly for very high doses. The applicability of the two regions method for thermal neutrons--gamma ray mixed field dosimetry was investigated by analysing the response of LiF:Mg,Ti dosemeters irradiated to different ratios of thermal neutrons and gamma rays at radiation protection dose levels encountered in routine work conditions, up to approximately 50 mSv. The Region of Interest method was used to define the areas of the Peaks 4 + 5 and 6 + 7. We found that a simple algorithm can be used to determine with good accuracy the separate contributions of neutron and gamma doses.

Computer Simulation↗

Response of LiF:Mg,Ti to low energy carbon and oxygen ions.

The extended track interaction model (ETIM) has been formulated to explain the TL-fluence response for peak 5 to heavy ions using radial dose distributions produced by the ions in LiF and their luminescent centre occupation probability distributions. In this work, an experimental study of the TLD-100 fluence response to carbon and oxygen ions and its interpretation in terms of a Monte Carlo simulation of ETIM applied to peak 5 are presented. Irradiations were performed with 7.34 and 10.3 MeV 12C and 8.34 MeV 16O ions in the fluence interval between 2 x 10(7) and 2 x 10(11) cm(-2). Individual glow curve responses show the expected increase of supralinearity as the peak temperature increases. Data for peak 5 show a weak dependence with energy. These latter results are difficult to understand when one considers the differences in the expected radial occupancies for different ion energies.

Carbon Radioisotopes↗

The application of LiF:Mg,Cu,P to large scale personnel dosimetry: current status and future directions.

LiF:Mg,Cu,P is starting to replace LiF:Mg,Ti in a variety of personnel dosimetry applications. LiF:Mg,Cu,P has superior characteristics as compared to LiF:Mg,Ti including, higher sensitivity, improved energy response for photons, lack of supralinearity and insignificant fading. The use of LiF:Mg,Cu,P in large scale dosimetry programs is of particular interest due to the extreme sensitivity of this material to the maximum readout temperature, and the variety of different dosimetry aspects and details that must be considered for a successful implementation in routine dosimetry. Here we discuss and explain the various aspects of large scale LiF:Mg,Cu,P based dosimetry programs including the properties of the TL material, new generation of TLD readers, calibration methodologies, a new generation of dose calculation algorithms based on the use of artificial neural networks and the overall uncertainty of the dose measurement. The United States Navy (USN) will be the first US dosimetry processor who will use this new material for routine applications. Until June 2002, the Navy used two types of thermoluminescent materials for personnel dosimetry, CaF2:Mn and LiF:Mg,Ti. A program to upgrade the system and to implement LiF:Mg,Cu,P, started in the mid 1990s and was recently concluded. In 2002, the new system replaced the LiF:Mg,Ti and is scheduled to start replacing the CaF2:Mn system in 2006. A pilot study to determine the dosimetric performance of the new LiF:Mg,Cu,P based dosimetry system was recently completed, and the results show the new system to be as good or better than the current system in all areas tested. As a result, LiF:Mg,Cu,P is scheduled to become the primary personnel dosimeter for the entire US Navy in 2006.

Copper↗

Determination of LiF:Mg,Ti and LiF:Mg,Cu,P TL efficiency for X-rays and their application to Monte Carlo simulations of dosemeter response.

The simulation of response of a new passive area dosemeter for measuring ambient dose equivalent H*(10) for photons has been performed using the Monte Carlo code MCNP and experimentally determined responses of LiF:Mg,Ti and LiF:Mg,Cu,P thermoluminescent (TL) detectors for hard-filtered X-ray spectra from 20 to 300 keV and for 137Cs and 60Co gamma radiation. Relative TL efficiency for both types of detectors, determined in experiments with bare detectors and similar Monte Carlo simulations, compared favourably with prediction of microdosimetric models for proposed microdosimetric target sizes in the range of 20-40 nm. The concluding verification experiment showed small deviations between measured and simulated dosemeter energy response values in the range of a few percent.

Algorithms↗