Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Flow Injection Analysis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39Linked to original sources

Liquid chromatographic methods for the isolation and identification of new pectenotoxin-2 analogues from marine phytoplankton and shellfish.

Two acidic analogues of the polyether marine toxin, pectenotoxin-2 (PTX-2), responsible for diarrhetic shellfish poisoning (DSP), have been isolated from the toxic marine phytoplankton (Dinophysis acuta), collected in Irish waters. Liquid chromatography with fluorimetric detection (LC-FLD) analyses of the extracts of bulk phytoplankton samples, following derivatisation with 9-anthryldiazomethane (ADAM) or 1-bromoacetylpyrene (BAP), showed a complex toxin profile with peaks corresponding to okadaic acid (OA) and its isomers, dinophysistoxin-2 (DTX-2) and DTX-2C, as well as other unidentified lipophilic acids. LC-UV analysis showed the presence of a diene moiety in these new compounds and two acids have been isolated. LC coupled with mass spectrometry (MS) and tandem mass spectrometry (LC-MS-MS) were used to gain structural information. Through flow injection analysis (FIA)-MS, both in positive and negative ion modes, the molecular weight of 876 for both compounds was determined. Collision Induced Dissociation (CID) from each parent ion, as performed both in positive and negative ion mode, produced mass spectra which were very similar to those obtained for authentic PTX-2 (mw 858). These new compounds have been confirmed to be pectenotoxin-2 seco acids (PTX-2SAs) and they are closely related to PTX-2 except that they contain an open chain carboxylic acid rather than a lactone ring. Toxic mussels also contained these pectenotoxin-2 analogues.

Chromatography, Liquid↗

Systematic examination of the signal area precision of a single quadrupole enhanced low mass option (ELMO) MSQ [corrected] mass spectrometer.

To examine the precision of the signal area response of an enhanced low mass option (ELMO) MSQmass spectrometer, operated in the negative electrospray ionization (ESI) mode, extended tests were performed, using flow injection analysis mass spectrometry (FIA-MS). Analytes were nitrate, nitrite, malonic acid, and D,L-mandelic acid. Composition and concentration of injected samples, application of an ASRS anion suppressor and of the cone wash unit, methanol addition to the FIA flow medium, and the voltage bias of the hexapole transfer lens were test variables. Individual test cycles comprised up to 90 injections, processed within 20 h. With a few exceptions the signal response tended to decline over time leading to a loss of more than 80% of the initial signal area in extreme cases. A hexapole radio-frequency (RF) voltage bias of -0.3 V led to an overall low detector response and to high losses of sensitivity over time. Other correlations between the insufficient signal reproducibility and FIA-MS operating conditions could not be established. The test scheme gave hints how to localize the cause of the mass spectrometer malfunction. The repetition of the test scheme after remedying the detected electronic default demonstrated that relative standard deviations less than 5% can be achieved for a sequence of 30 injections if methanol is added to the FIA flow medium and if a suppressor is used. Based on these findings a recommendation is formulated to supplement current test schemes for instrument performance verification by a detector response precision criterion.

Journal Article↗

Electrochemistry and detection of some organic and biological molecules at conducting poly(3-methylthiophene) electrodes.

Electrodes modified by the electrodeposition of poly(3-methylthiophene) were used as chemical sensors for some organic and biological molecules of industrial and medicinal interest. The electrochemical behaviors of ferri/ferrocyanide, catechol, ascorbic acid, hydroquinone, dopamine epinephrine, acetaminophen, p-aminophenol and NADH were examined by cyclic voltammetry. The results showed that the proposed modified surface catalyzes the oxidation of these compounds. Differential pulse and square wave techniques were used for the analysis of binary mixture of ascorbic acid with catechol, NADH, dopamine and p-aminophenol. Voltammetric peak resolution was also demonstrated for a ternary mixture of ascorbic acid, catechol and p-aminophenol. Polymer coated electrode was also used in an amperometric detector for flow injection analysis of most of the aforementioned compounds. The responses of the polymer electrode were 4-10 times larger as compared to those of platinum. The modified electrode displayed excellent response stability for successive injections and detection limits were 10 ppb for catechol, dopamine, epinephrine, NADH and p-aminophenol, 1 ppb for acetaminophen and 100 ppb for ascorbic acid. Voltammetric peak positions were affected by the nature of the electrolyte and its pH. Also, film thicknesses were shown to be a factor affecting both the current magnitudes and oxidation peak potential of NADH.

Acetaminophen↗

Use of a copper electrode in alkaline medium as an amperometric sensor for sulphite in a flow-through configuration.

A flow injection analysis (FIA) method has been developed for the determination of sulphite in beverages. The method is based on the amperometric detection (0.60 V vs Ag/AgCl (sat. NaCl)) of the analyte at a copper surface in an alkaline medium (1 M NaOH solution) with a manifold that incorporates flow extraction of sulphite as SO2 through a PTFE membrane. Under optimal experimental conditions the peak current response increases linearly with sulphite concentration over the range from 1.0 to 5.0 mM. The repeatability of the electrode response in the FIA configuration was evaluated as 4% ( n =20), the limit of detection of the method was 0.04 mM (S/N =3) and the analytical frequency was 50 h(-1). Since ethanol is also electroactive and permeates through the PTFE membrane, a strategy involving in a first step measurements of only ethanol by manipulating the pH of the donor stream was employed for wine samples. Then, both ethanol and sulphite were measured at the copper electrode at 0.40 V vs Ag/AgCl (sat. NaCl) and the sulphite concentration was determined by difference. Results for 3 different beverage samples (alcoholic and non-alcoholic) showed excellent agreement with the ones obtained by using a recommended procedure for sulphite analysis.

Copper↗

Validation of liquid chromatography-electrospray ionization ion trap mass spectrometry method for the determination of mesocarb in human plasma and urine.

Mesocarb metabolism in humans is the target of this investigation. A high-performance liquid chromatographic (LC) method with electrospray ionization (ESI)-ion trap mass spectrometric (MS) detection ion trap "SL" for the simultaneous determination of mesocarb and its metabolites in plasma and urine is developed and validated. Ten metabolites and the parent drug are detected in human urine, and only four in human plasma, after the administration of a single oral dose of 10 mg of mesocarb (Sydnocarb, two 5-mg tablets). Seven of this metabolites have been found for the first time. The confirmation of the results and identification of all the metabolites except amphetamine is performed by LC-MS, LC-MS-MS, and LC-MS3. In the case of doping analysis, the reliable detection time for mesocarb (long-life dihydroxymesocarb metabolites of mesocarb) is approximately 10-11 days after the administration of the drug, which is a significant increase over the existing data. The detection of amphetamine in plasma and urine is made using simple flow-injection analysis without a chromatographic separation. The addition-calibration method is used with plasma and urine. The mean recoveries from plasma are 49.2% and 57.4% for mesocarb concentrations of 33.0 and 66.0 ng/mL, respectively, whereas the recoveries from human urine are 76.9% and 81.4% for concentrations of 1 and 2 ng/mL, respectively. Calibration curves (using an internal standard method) are linear (r2>0.9969) for concentrations 0.6 to 67 ng/mL and from 0.05 to 5 ng/mL in plasma and urine, respectively. Both intra- and interassay precision of plasma control samples at 3, 40, and 55 ng/mL are lower than 6.2%, and the concentrations do not deviate for more than -3.4% to 7.3% from their nominal values. In urine, intra- and interassay precision of control samples at 0.08, 1.5, and 3.0 ng/mL is lower than 14.1%, with concentrations not deviating for more than -11.3% to 13.7% from their nominal values. The plasma disappearance curve of the parent drug is obtained. The major pharmacokinetic parameters are calculated.

Adult↗

Atmospheric pressure electrospray ionization mass spectra of glucose and 2-fluorodeoxyglucose for quantitative analysis of 2-fluorodeoxyglucose by high-performance liquid chromatography.

2-Fluoro-2-deoxy-D-glucose (FDG) labeled by fluorine-18 is the most widely used radiopharmaceutical for positron emission tomography (PET). For high-performance liquid chromatography (HPLC)/MS assay and quality control, the mass spectra of FDG and glucose (Glc) in organic + water solutions were studied by flow injection analysis (FIA) and in a chromatographic eluate. In acetonitrile (MeCN) + 0.025% ammonium formate (NH(4)HCO(2)) solvent (80 : 20), electrospray ionisation (ESI) of glucose-FDG provides M.NH(4)(+) and 2M.Na(+) (M = Glc or FDG) as the most intense positive ions. Formation of the latter ions and also of M.MeCN.Na(+) and 2MeCN. Na(+) is typical of the presence of NaCl in the ESI inlet. The positive ions include heavier ions corresponding to the impurities separated by HPLC and also to the cross-ring fragmentation of complexes (2FDG. aMeCNX)L, where a = 0 or 1, L is either Na(+) or NH(4)(+) and X is a fragmented pyranose or anhydropyranose residue. The second most abundant Glc negative ion is m/z = 359 which was interpreted as (2GlcH(+))(). The negative-ion spectrum of FDG has dominating lines due to FDG.HCO(2)() ions at m/z 227 and also (2FDGH(+))() at m/z 363. The m/z 363 signal is suppressed in the presence of NaCl at a molar ratio of 4 : 1 to NH(4)HCO(2), while the ions at m/z 217 and 219, i.e. FDG.Cl(), become three times more intense than FDG.HCO(2)(). The latter ion appears to be most suitable as an analytical signal for chemical analysis of FDG at m/z 226 and 227. Limits of FDG quantitation (LOQ) of 19 ng and 21 ng were found for the 200(+) and 227() ion signals, respectively, and are wholly adequate for verification of total FDG content in radiopharmaceuticals.

Atmospheric Pressure↗

Chemical polymerization of m-phenylenediamine, in the presence of glucose oxidase, produces an enzyme-retaining electrooxidisable polymer used to produce a biosensor for amperometric detection of glucose from brain dialysate.

A new procedure involving chemical polymerization of a monomer of m-phenylenediamine (m-ppd) containing glucose oxidase (GOx) and subsequent electro-synthesis of the functional GOx containing polymer onto platinum needle electrodes (PTNE) was used for the amperometric analysis of glucose concentration in brain dialysates. Monomer solutions of o-phenylenediamine (o-ppd) and m-ppd were polymerized by low concentrations of glutaraldehyde (GA) and precipitated from solution. The 1,3 position of the amines on the benzene was amenable to stable polymerization by GA but polymerization of o-ppd (1,2 position) by GA was unstable and degraded. Polymerization of m-ppd appears to proceed by dehydration synthesis. GA induced polymerization of m-ppd polymer in the presence of GOx produced a polymer with strongly bound, functional GOx. This GOx-m-ppd polymer formed a stable matrix that was effectively employed in flow injection analysis (FIA) of glucose. If maintained under O(2) free atmosphere after chemical polymerization, the GOx-m-ppd polymer retained the ability to be electropolymerized. PTNE coated with GOx-m-ppd polymer by repeated dip/amperometry produced stable, sensitive amperometric glucose sensors with good interference exclusion properties and long shelf life. Scanning EM demonstrated that amperometry modified the structure of the GOx-m-ppd on the PTNE surface. GOx-m-ppd PTNE glucose sensors and bare PTNE were placed in a radial flow cell and FIA was employed for the simultaneous measurement of glucose and ascorbic acid, respectively, from dialysates of brain tissue.

Biosensing Techniques↗

Use of a bioreactor consisting of sequentially aligned L-glutamate dehydrogenase and L-glutamate oxidase for the determination of ammonia by chemiluminescence.

A chemiluminometric method for the automated flow injection analysis of ammonia is described. The essence of the invention is the use of a bioreactor consisting of both immobilized L-glutamate dehydrogenase (GLDH) and L-glutamate oxidase (GLXD), which are sequentially aligned in this order in a minicolumn measuring 2.0 X 20 mm. The unidirectional constant flow of liquid through the column reactor minimizes the reversed diffusion of the solutes so that the following sequence of reactions is ensured. Thus, ammonia to be determined is first transformed by GLDH into L-glutamate, which then produces hydrogen peroxide by GLXD. Hydrogen peroxide in the effluent from the column is then determined by its chemiluminescence upon admixing with luminol and potassium ferricyanide. The present method gives linearity of the standard curve for ammonia up to 1.0 mM. It is at least 100 times more sensitive than the conventional method for ammonia assay using ultraviolet absorption measurement.

Amino Acid Oxidoreductases↗

Enantioselective analysis of methadone in saliva by liquid chromatography-mass spectrometry.

Saliva was tested and evaluated as a biological matrix for methadone (Mtd) monitoring. Conventional method using a narrow bore C18 column, and an enantioselective method using a narrow bore alpha1-acid glycoprotein column, were developed using liquid chromatography coupled with a mass spectromeric (MS) detector. After optimisation of MS conditions by flow injection analysis, selected ion monitoring detection was used to enhance sensitivity. The total Mtd concentration and the enantiomeric ratio in saliva were validated using an experimental design. The methods were applied to samples provided by heroin addicts undergoing a Mtd treatment. Results on total Mtd determination showed a very poor correlation between saliva and serum, whereas the enantiomeric ratios of Mtd gave a very good one.

Chromatography, Liquid↗

Design and use of electrochemical sensors in enantioselective high throughput screening of drugs. A minireview.

The importance of reliable detection systems for enantiomeric assays increases with the necessity of high throughput screening analysis of raw materials for the pharmaceutical industry. The utilization of electrochemical sensors in enantioselective analysis is an accurate and precise alternative to chromatographic techniques. The reliability of the response characteristics as well as of the analytical information obtained by using electrochemical sensors is strictly correlated with the design of the sensors. The designs evaluated for sensors have been based on PVC, imprinting polymers and carbon paste matrices. Among these, carbon paste sensors have been the most reliable and have been utilized for the construction of potentiometric, enantioselective membrane electrodes as well as for amperometric biosensors, and immunosensors. There are two ways to use the electrochemical sensors in enantioselective screening analysis: selective binding and catalyst selectivity. A molecule with a special chemical architecture is required for selective binding: a lock for a key. The high reliability of analytical information obtained using these sensors has made possible the automation of potentiometric and amperometric techniques by integration of enantioselective sensors as detectors in flow injection analysis and sequential injection analysis techniques.

Animals↗

Analysis by surface enhanced Raman spectroscopy on silver hydrosols and silver coated filter papers.

Surface enhanced Raman spectrometry (SERS) is an analytical technique with a sensitivity comparable to that of conventional molecular absorption or fluorescence spectroscopy, with the additional major advantage of selectivity inherent in vibrational spectroscopies. The analytical application of flowing silver hydrosols is described. Under the controlled experimental conditions of flow injection analysis, it was possible to detect as low as 30 ng of p-aminobenzoic acid. The linear range was two orders of magnitude (1-100 microg ml(-1)) with a signal reproducibility of 3.2%. Silver coated filter paper is another SERS active substrate that is simple to prepare and handle. The SERS spectra of several nitrogen-containing molecules were obtained on these substrates. The effects of laser power and paper hydration are described. The relative advantages of both substrates are compared.

Journal Article↗

Electrocatalytic cyclization of dithiothreitol on a chemically modified electrode by analogy with protein action.

Electrocatalytic oxidative cyclization of dithiothreitol (DTT(SH)2) to a disulfide product was demonstrated on a Nafion/lead-ruthenium oxide pyrochlore chemically modified electrode (NPyCME). The process at the NPyCME with DTT(SH)2 is similar to the behaviour of protein in a disulfide linkage, which can be demonstrated by product analysis using HPLC coupled with UV spectroscopy. A possible electrocatalytic mechanism for DTT(SH)2 oxidation to dihydroxydithiane [i.e. cyclized DTT(S-S)] on the NPyCME was proposed in terms of Py-Ru(IV)/Py-Ru(VI) redox active sites. This physical aspect was further utilized for high precision analytical assays using flow injection analysis (FIA), with a linearity up to 50 microM and a detection limit (S/N = 3) of 28 nM (8.64 pg) in a 20 microL sample loop. This is the most sensitive method ever reported for DTT(SH)2 detection assays. The interference from dissolved oxygen, disulfide and glucose is almost negligible. The present method offers an easy route for extension to redox-related protein studies.

Journal Article↗

Correlation of 32P-postlabelling-detection of DNA adducts in mouse skin in vivo with the polycyclic aromatic compound content and mutagenicity in Salmonella typhimurium of a range of oil products.

The in vivo genotoxic activities in mouse skin of the dimethyl sulphoxide (DMSO) extracts of a range of oil products [residual aromatic extract; untreated heavy paraffinic distillate aromatic extract; mildly refined light naphthenic base oil; bitumen (vacuum residue); high viscosity index base oil obtained by catalytic hydrogenation] were evaluated by 32P-postlabelling DNA analysis. The results of quantitative 32P-postlabelling analyses of epidermal DNA from mice treated with the DMSO extracts showed linear relationships with the total polycyclic aromatic compound (PAC) contents, determined by the Institute of Petroleum method IP 346 and also the 3-6 ring PAC contents, measured by on-line liquid-liquid extraction using flow injection analysis. The 32P-postlabelling data also showed a linear relationship with the mutagenicity indices of these oil products determined in S. typhimurium TA98 using the modified Ames Salmonella microsome test. The in vivo genotoxicity of the DMSO extracts from the oil products was low, judged by 32P-postlabelling analysis of DNA adducts measured in epidermal DNA of treated mouse skin, and ranging from 2 to 723 attomole/microg DNA per mg oil product. The in vivo 32P-postlabelling data from this study are consistent with these materials expressing low genotoxicity in mouse skin in vivo. The DMSO extraction procedure coupled with 32P-postlabelling DNA analysis is useful for ranking the relative genotoxic potency in vivo of a wide range of oil products. In general the trend observed is similar to rankings based on physicochemical measurements of total PAC contents or 3 6 ring PAC contents of the oil products.

Animals↗

High throughput quantification of cholesterol and cholesteryl ester by electrospray ionization tandem mass spectrometry (ESI-MS/MS).

Analysis of free cholesterol (FC) is not well suited for electrospray ionization (ESI); however, cholesteryl ester (CE) form ammonium adducts in positive ion mode and generate a fragment ion of m/z 369 upon collision-induced fragmentation. In order to allow parallel analysis of FC and CE using ESI tandem mass spectrometry (ESI-MS/MS), we developed an acetyl chloride derivatization method to convert FC to cholesteryl acetate (CE 2:0). Derivatization conditions were chosen to provide a quantitative conversion of FC to CE 2:0 without transesterification of naturally occurring CE species. FC and CE were analyzed by direct flow injection analysis using a fragment of m/z 369 in a combination of selected reaction monitoring (SRM) and precursor ion scan for FC and CE, respectively. Quantification was achieved using deuterated D(7)-FC and CE 17:0/CE 22:0 as internal standards as well as calibration lines generated by addition of FC and naturally occurring CE species to the respective sample matrix. The developed assay showed a precision and detection limit sufficient for routine analysis. A run time of 1.3 min and automated data analysis allow high throughput analysis. Loading of human skin fibroblast and monocyte derived macrophages with stable isotope labeled FC showed a potential application of this method in metabolism studies. Together with existing mass spectrometry methodologies for lipid analysis, the present methodology will provide a useful tool for clinical and biochemical studies and expands the lipid spectrum that can be analyzed from one lipid sample on a single instrumental platform.

Cholesterol↗

Indirect flow-injection spectrophotometric determination of meloxicam, tenoxicam and piroxicam in pharmaceutical formulations.

A simple and sensitive indirect spectrophotometric method for the assay of meloxicam (MX), tenoxicam (TX) and piroxicam (PX) in pure and in pharmaceutical formulations by flow injection analysis (FIA) has been proposed. The method is based on the oxidation of these drugs by a known excess of N-bromosuccinimide (NBS) in an acidic medium, followed by a reaction of excess oxidant with chloranilic acid (CAA) to bleach its purple color. The absorbance values increased linearly with increasing concentrations of the drugs. Variables, such as the acidity, reagent concentrations, flow rate of reagents and other FI parameters were optimized to produce the most sensitive and reproducible results. The system obeyed Beer's low over concentration ranges of 10 - 160, 20 - 200 and 10 - 160 microg/ml for MX, TX and PX, respectively. The common excipients and additives did not interfere with their determinations. The method was successfully applied to the determinations of MX, TX and PX in various pharmaceutical preparations. The results obtained by the proposed method were found to be in good agreement with those found by the official HPLC methods.

Benzoquinones↗

Atmospheric pressure chemical ionization and atmospheric pressure photoionization for simultaneous mass spectrometric analysis of microbial respiratory ubiquinones and menaquinones.

An atmospheric pressure photoionization (APPI) source and an atmospheric pressure chemical ionization (APCI) source were compared for the selective detection of microbial respiratory ubiquinone and menaquinone isoprenologues using tandem mass spectrometry. Ionization source- and compound mass-dependent parameters were optimized individually for both sources, using the available quinone standards. Detection levels for the two ion sources were determined with ubiquinone-6 (UQ6) and menaquinone-4 (MK4, vitamin K2) standards using flow injection analysis and selected reaction monitoring (SRM). With APPI the calculated lower limit of detection (LLOD) was 1.7 fmol microl(-1) for UQ6 and 2.2 fmol microl(-1) for MK4 at a signal-to-noise ratio of 3. These LLODs were at least three times lower than with APCI. The selectivity of detection afforded by SRM detection reduced complex mixture analysis to 3 min per sample by eliminating the need for chromatographic separations. The detection method was successfully applied to quinone quantification in a variety of environmental samples and cell cultures. Adequate amounts of respiratory quinones can be extracted and quantified from samples containing as low as 2 x 10(7) cells.

Atmospheric Pressure↗

Sensitive characterization of microbial ubiquinones from biofilms by electrospray/mass spectrometry.

Utilizing high-performance liquid chromatography/electrospray/tandem mass spectrometric analysis of the neutral lipid extract of microbial cells and biofilm communities, respiratory ubiquinone (UQ) (1-methyl-2-isoprenyl-3,4-dimethoxyparabenzoquinone) isoprenologues can be separated isocratically in minutes and assayed with a limit of quantification (LOQ) of 9 p.p.b. (11.1 fmol UQ9 microL(-1)). This corresponds to about 1.29 x 10(7) cells of Pseudomonas putida. Highest sensitivity is achieved using flow-injection analysis with multiple reaction monitoring wherein ammoniated molecular ions of specific isoprenologues pass through quadrupole one, are collisionally dissociated in quadrupole two and identified from the product ion fragment at m/z 197.1 in quadrupole three. This assay has a repeatability of between 6% and 10% over three orders of magnitude (r2 = 0.996). Quinone profiling based on dominant isoprenologue patterns provides taxonomic insights. Detection of prominent UQ isoprenologues indicates presence of microeukaryotes and alpha Proteobacteria with UQ10, obligatory aerobic Gram-negative bacteria with UQ4-14, facultative Gram-negative (and some gamma Proteobacteria growing in microniches with oxygen or to a much lesser extent nitrate as a terminal electron acceptor with UQ8, and other gamma Proteobacteria with UQ9. High sensitivity is essential as the phospholipid fatty acid (PLFA) to UQ molar ratios are 130 or greater. Previous studies have established that recovery of sediment communities with high PLFA/UQ ratios corresponded to areas of aerobic metabolism, an important consideration in bioremediation or nuclide mobilization.

Biofilms↗

Simultaneous determination of dysprosium and iron in urine by capillary zone electrophoresis coupled to cloud point extraction.

Automated preconcentration strategies are needed when analyzing metals in real samples by capillary electrophoresis (CE) with UV detection. The on-line incorporation of cloud point extraction (CPE) to flow injection analysis (FIA) associated with CE for simultaneously determining dysprosium and iron at ppb levels in urine is presented and evaluated for the first time. The preconcentration step is mediated by micelles of the non-ionic surfactant polyethyleneglycol-mono-p-nonylphenylether (PONPE 7.5) with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol. The micellar system containing the complex was loaded into the FIA manifold at a flow rate of 8 mlmin(-1), and the surfactant rich-phase was retained in a microcolumn packed with cotton, at pH 9.2. The surfactant-rich phase was eluted with 50 microl acetonitrile directly into the CE sample vial, allowing to reach an enrichment factor of 200-fold for a 10 ml sample urine. The type and composition of the background electrolytes (BGE) were investigated with respect to separation selectivity, reproducibility and stability. A BGE of 20mM sodium tetraborate buffer containing 13% acetonitrile, pH 9.0 was found to be optimal for the separation of metal chelates. Detection was performed at 585 nm. An enhancement factor of 200 was obtained for the preconcentration of 10 ml of sample solution. The detection limits for the preconcentration of 10 ml of urine were 0.20 microgl(-1) for Dy, and. 0.48 microgl(-1) for Fe. The calibration graphs using the preconcentration system were linear with a correlation coefficient of 0.9989 (Dy) and 0.9976 (Fe) at levels near the detection limits up to at least 500 microgl(-1). The method was successfully applied to the determination of dysprosium and iron in urine for monitoring the elimination of dysprosium-based pharmaceuticals.

Dysprosium↗