Stress analysis of interbody fusion--finite element modelling of intervertebral implant and vertebral body.

OBJECTIVE: To investigate stresses in cage type interbody fusion systems during compressive loading.Design. The study uses finite element methods to investigate predicted stresses. Previously published experimental material properties are used as inputs to the numerical simulation. BACKGROUND: Interbody spinal fusion procedures using cage style intervertebral implants often cause subsidence failure of the vertebral endplate, resulting in potential pain and mechanical instability of the fusion system. METHODS: Finite element models were developed to simulate compressive load transfer between interbody implants and adjacent vertebral body. The vertebral body was modelled using separate finite element mesh regions for cancellous core and cortical shell, with the meshes tied together at the core/shell interface. Coulomb friction was implemented to model the contact between implants and vertebral endplate.Results. Simulation results predicted endplate stresses of approximately 12 times the nominal contact pressure due to differing deformation stiffnesses of the implant and endplate structures. Reduction of the cancellous core elastic modulus to simulate severely osteoporotic bone resulted in endplate stresses up to three times higher than the values for an intact cancellous core. CONCLUSIONS: In this study, finite element analysis was used to investigate the stresses in interbody fusion systems. Published vertebral loads corresponding to certain activities were shown to generate endplate stresses which approach and exceed the failure stress for cortical bone. Endplate stresses are strongly dependent on the modulus of the underlying cancellous core. RELEVANCE: Endplate subsidence failure can potentially occur at the corners of existing cage-type interbody implants under physiological compressive loads. Matching material properties between cortical endplate and implant does not guarantee optimal contact conditions, and overall bending stiffness should be assessed.

Compressive Strength↗

A penetration-based finite element method for hyperelastic 3D biphasic tissues in contact: Part 1--Derivation of contact boundary conditions.

In this study, we extend the penetration method, previously introduced to simulate contact of linear hydrated tissues in an efficient manner with the finite element method, to problems of nonlinear biphasic tissues in contact. This paper presents the derivation of contact boundary conditions for a biphasic tissue with hyperelastic solid phase using experimental kinematics data. Validation of the method for calculating these boundary conditions is demonstrated using a canonical biphasic contact problem. The method is then demonstrated on a shoulder joint model with contacting humerus and glenoid tissues. In both the canonical and shoulder examples, the resulting boundary conditions are found to satisfy the kinetic continuity requirements of biphasic contact. These boundary conditions represent input to a three-dimensional nonlinear biphasic finite element analysis; details of that finite element analysis will be presented in a manuscript to follow.

Anisotropy↗

Shear versus micro-shear bond strength test: a finite element stress analysis.

OBJECTIVES: This study aimed at comparing the stress distribution in shear and micro-shear test set-ups using finite element analysis, and suggesting some parameter standardization that might have important influence on the results. METHODS: Two-dimensional plane strain finite element analysis was performed using MSCPatran and MSCMarc softwares. Model configurations were based on published experimental shear and micro-shear test set-ups and material properties were assumed to be isotropic, homogeneous and linear-elastic. Typical values of elastic modulus and Poisson's ratios were assigned to composite, dentin and adhesive. Loading conditions considered a single-node concentrated load at different distances from the dentin-adhesive interface, and proportional geometry (1:5 scale, but fixed adhesive layer thickness in 50microm) with similar calculated nominal strength. The maximum tensile and shear stresses, and stress distribution along dentin-adhesive interfacial nodes were analyzed. RESULTS: Stress distribution was always non-uniform and greatly differed between shear and micro-shear models. A pronounced stress concentration was observed at the interfacial edges due to the geometric change: stress values farther exceeded the nominal strength and tensile stresses were much higher than shear stresses. For micro-shear test, the relatively thicker adhesive layer and use of low modulus composites may lead to relevant stress intensification. An appropriate loading distance was established for each test (1mm for shear and 0.1mm for micro-shear) in which stress concentration would be minimal, and should be standardized for experimental assays. SIGNIFICANCE: The elastic modulus of bonded composites, relative adhesive layer thickness and load application distance are important parameters to be standardized, once they influence stress concentration.

Composite Resins↗

A comparison of three-dimensional finite element stress analysis with in vitro strain gauge measurements on dental implants.

PURPOSE: The purpose of this study was to evaluate the compatibility of three-dimensional finite element stress analysis and in vitro strain gauge analysis in the measurement of strains on a dental implant. MATERIALS AND METHODS: Two vertically placed implants embedded in a poly(methyl methacrylate) model were used. Strain gauges were bonded to the cervical parts of the implants, and seven cement-retained fixed partial dentures were fabricated. A three-dimensional model of the strain gauge analysis model was constructed, and an additional model in which human bone simulation was provided was also constructed. A static vertical load of 50 N was applied at certain locations to simulate centrally positioned axial and laterally positioned axial loading for strain gauge analysis and three-dimensional finite element stress analysis. RESULTS: Statistically significant increases in strain levels were recorded between loading types in the strain gauge analysis (P < .05). Strains obtained from strain gauge analysis were higher than for three-dimensional finite element stress analysis. There was a remarkable difference between the two finite element models under the conditions of laterally positioned axial loading. CONCLUSION: There are differences regarding the quantification of strains between strain gauge analysis and three-dimensional finite element stress analysis. However, there is a mutual agreement and compatibility between three-dimensional finite element stress analysis and in vitro strain gauge analysis on the determination of the quality of induced strains under applied load.

Analysis of Variance↗

Finite element thermal analysis of bone cement for joint replacements.

A finite element technique was developed to investigate the thermal behavior of bone cement in joint replacement procedures. Thermal tests were designed and performed to provide the parameters in a kinetic model of bone cement exothermic polymerization. The kinetic model was then coupled with an energy balance equation using a finite element formulation to predict the temperature history and polymerization development in the bone-cement-prosthesis system. Based on the temperature history, the possibility of the thermal bone necrosis was then evaluated. As a demonstration, the effect of cement mantle thickness on the thermal behavior of the system was investigated. The temperature profiles in the bone-cement-prosthesis system have shown that the thicker the cement, the higher the peak temperature in the bone. In the 7 mm thick cement case, a peak temperature of over 55 degrees C was predicted. These high temperatures occurred in a small region near the bone/cement interface. No damage was predicted in the 3 mm and 5 mm cement mantle thickness cases. Although thermal damage was predicted in the bone for the 7 mm mantle thickness case, the amount of thermal necrosis predicted was minimal. If more cement is used in the surgical procedure, more heat will be generated and the potential for thermal bone damage may rise. The systems should be carefully selected to reduce thermal tissue damage when more cement is used. The methodology developed in this paper provides a numerical tool for the quantitative simulation of the thermal behavior of bone-cement-prosthesis designs.

Animals↗

A novel ultrasound indentation system for measuring biomechanical properties of in vivo soft tissue.

Technologies for soft tissue analysis are advancing at a rapid place. For instance, elastography, which provides soft tissue strain images, is starting to be tried in clinical practice as a tool for diagnosing cancer. Soft tissue deformation modeling and analysis is also an active area of research that has application in surgery planning and treatment. Typically, quantitative soft tissue analysis uses nominal values of soft tissue biomechanical properties. However, in practice, soft tissue properties can vary significantly between individuals. Hence, for soft tissue methodologies to reach their full potential as patient-specific techniques, there is a need to develop ways to efficiently measure soft tissue mechanical properties in vivo. This paper describes a prototype real-time ultrasound (US) indentation test system developed to meet this need. The system is based on the integration of a force sensor and an optical tracking system with a commercial US machine integrated with a suite of analysis methodologies. In a study on a single-layer phantom, we used the system to compare various methods of estimating linear elastic properties (via a theoretical approximation, 2-D finite element analysis, 3-D finite element analysis and a standard material-testing method). In a second study on a three-layer gelatin phantom, we describe a new finite-element-based inverse solution for recovering the Young's moduli of each layer to show how the system can estimate properties of internal components of soft tissue. Finally, we show how the system can be used to derive a modified quasilinear viscoelastic (QVL) model on real breast tissue.

Biomechanical Phenomena↗

Methods to improve a periodontally involved terminal abutment of a cantilever fixed partial denture--a finite element stress analysis.

The two-dimensional plane stress finite element stress analysis was used to evaluate the stress of mandibular posterior cantilevers for compromised periodontal involved distal terminal abutments. Some commonly practiced methods to alleviate the stress from mastication of the cantilever FPDs were also evaluated. From the analysis the following was concluded: (1) The most distal terminal abutment of a cantilever FPD generally experienced a high stress concentration. (2) The cantilever FPDs require at least two abutments. Optimum stress reduction occurred with a splinting of three abutments. To increase the number of abutments to more than three, would not result in a proportional and meaningful reduction of stress in the periodontium. (3) To alter the bridge material with more rigid material or to have a longer marginal preparation of the terminal abutment are ineffective for better stress distribution.

Alveolar Process↗

Finite element stress analysis of the wrist joint without and with an endoprosthesis.

The finite element analysis method was used to obtain the lateral deformation profile and values of the von Mises stress in the cortical and cancellous regions of the various bones in models of a selected space in the coronal plane of a human wrist joint, without and with a prosthesis. The prosthesis was the metacarpal component of the Trispherical design of the total wrist joint arthroplasty. The models included all the bones, the associated network of ligaments, and the intervening soft muscle tissue. Each type of model was completely constrained along its entire proximal surface and subjected to either a static point force (in the axial compressive or anteroposterior tensile direction) acting at the center of the distal tip of the third metacarpal cortical bone. For the models containing the prosthesis, a parametric study was conducted involving the method of anchorage of the prosthesis to the contiguous bones and the material of fabrication of the prosthesis. It was found that: (1) the axial force produces lower stresses in the bones compared with the anteroposterior one; (2) no clear-cut case can be advanced, from the stress viewpoint, for press-fitting the prosthesis to the contiguous bones rather than using bone cement for such anchorage; and (3) any alloy with modulus of elasticity in the 79 to 196 GPa range and Poisson's ratio of about 0.3 may be used to fabricate the prosthesis. The approximations used and the associated limitations of the work are fully discussed, as are the design implications and clinical significance of the results.

Humans↗

Finite element-based cephalometric analysis.

The finite element method has proven to be a useful tool for morphometric analysis in craniofacial biology. However, few attempts have been made to adapt this method for routine use by clinicians. The CEFEA program incorporates the advanced features of the finite element method but bypasses the detailed understanding of the engineering and mathematics previously required to interpret results. The program uses the color graphics display of common personal computers to show size change, shape change, and angle of maximum change. These are pictured as colored triangles of clinically relevant regions between pre- and mid- or posttreatment lateral headfilms. The program is designed to have features of interest in both clinical practice and research.

Cephalometry↗

Evaluation of a synthetic bone defect test model to aid in the selection of materials for use in vertebral body compression fracture repair.

A synthetic test model was developed to assist in screening injectable cements with a focus on mechanical strength for vertebral body compression fracture repair. The two-part defect model consisted of a polyurethane foam cube to simulate trabecular bone and a defect to which various injectable cements could be introduced. In addition, a finite element analysis model was developed and the results were compared to laboratory testing. Agreement was found between the finite element analysis and test results. Once the finite element analysis model was validated with experimental data, an additional finite element analysis was conducted to study various parameters affecting mechanical performance such as simulated bone and cement stiffness. Finite element analysis models were also created using orthotropic bone properties typical of healthy trabecular bone and were compared to various foam stiffnesses. The foam model was a good in vitro representation of actual trabecular bone found in vertebral bodies and is a valid model to evaluate the mechanical strength of injectable cements for percutaneous vertebral body fracture repair.

Bone Cements↗

Finite element stress analysis of a new design of synthetic leaflet heart valve.

This paper presents a parametric finite element analysis of the stresses in the leaflets of a new design of polyurethane heart valve in the closed position. The alpharabola geometry of the valve has previously been reported by Leat and Fisher (1) and has been shown to demonstrate good opening characteristics. The effects of variations in leaflet offset parameter, g, length, h, and local thickening have been determined for a valve where the frame is assumed rigid. A spherical leaflet geometry has also been analysed for comparative purposes. Results have shown that the alpharabola leaflet geometry can reduce the maximum principal tensile stress to 60 per cent of that for a spherical valve of the same mesh density.

Biocompatible Materials↗

Finite element contact analysis of the hip joint.

The hip joint plays an important role in the musculoskeletal system; however, current knowledge of the mechanics of the hip joint, especially with regard to the distribution of stress, remains limited. In experimental research, difficulties arise during reproduction of physiological conditions of daily activities and practicable measurement of locations inside the hip joint without violating the physiological environment. On the other hand, numerical approaches, such as finite element analysis, have become useful tools in the field of biomechanics. In finite element contact analysis of the hip joint, due to discretization of contact surfaces, computational instability might occur when the contact nodes move near the edges of the contact elements. In this study, to overcome this problem, a contact smoothing approach was introduced by applying Gregory patches. Contact analysis of the hip joint was then performed for three representative daily activities; i.e., walking, rising up from a chair and knee bending. The effectiveness of the adopted smoothing approach was verified by comparing the results with those obtained experimentally. The distribution and history of contact stress, which have heretofore been scarcely reported, were also obtained and the implications associated with osteoarthritis were discussed.

Algorithms↗

Micromechanical analysis of dentin/adhesive interface by the finite element method.

The interfacial microstructure and spatial distribution of the modulus of elasticity have a profound effect on load transfer at the dentin/adhesive (d/a) interface. The microstructure is influenced by the varying degree of demineralization of intertubular and peritubular dentin during etching as well as the depth of adhesive penetration into the hybrid layer. These factors lead not only to a unique microstructure in the vicinity of the dentinal tubules, but also to a mechanically graded hybrid layer. This article investigates the micromechanical stress distribution at a d/a interface with the use of finite element analysis (FEA). Such analysis is now feasible given the newly measured moduli of elasticity at micro- and nanoscales. The results indicate that the morphological and micromechanical properties of the d/a interface affects the stress field such that the fracture/failure is likely to initiate in the stress-concentration zone of peritubular dentin next to the hybrid/exposed-collagen layer. The results suggest that devising a full-depth high modulus hybrid layer may considerably reduce the stress concentration zone and the magnitude of stress concentration in the peritubular dentin next to the hybrid/exposed-collagen layer.

Adhesives↗

A quantitative genetic analysis of localized morphology in mandibles of inbred mice using finite element scaling analysis.

We analyzed patterns of mandibular genetic and phenotypic morphological integration and the relationship of genealogy to interstrain molecular and morphological differences in ten inbred strains of mice. Positions of mandibular landmarks in two-dimensional space were used to construct a finite element mesh for each individual, then all individuals from the ten strains were compared to the average mandible from a standard strain (SEA/GnJ). Measures of size and shape associated with finite element scaling analysis were then used in a quantitative genetic analysis of mandibular variation. Significant genetic variation for mandibular size and shape was uncovered. Patterns of both genetic and phenotypic correlation for measures of landmark-specific sizes were consistent with models of morphological integration based on the developmental origin of parts of the mandible and on the effects of muscle attachment on mandibular morphology. Shape differences local to particular landmarks did not show these forms of morphological integration. Although interstrain distances based on local shape magnitudes were significantly correlated with genealogical relationship, distances based on local size differences were not. Even higher than the correlation of genealogy with distances based on local shape magnitude was the genealogical-molecular distance correlation. Patterns of morphometric mandibular variation corresponded to expected effects of epigenetic developmental processes. Also, when detailed shape differences were considered, morphology served as a rough guide to genealogy, although molecular distances showed a stronger relationship.

Animals↗

[Three-dimensional finite element stress analysis of different designs of shape in all-ceramic crowns].

OBJECTIVE: The purpose of this study was to examine the effect of different occlusal thickness on the stress distribution of all-ceramic crowns of the mandibular first molar. METHODS: Three-dimensional finite element analysis was made. RESULTS: It was found that under the simulated applied loads, the values of tensile and shear stress varied with the occlusal thickness, and much greater values of such stresses were noticed in the all-ceramic crowns 1.0 mm in occlusal thickness, compared with those in the crowns 1.5 mm and 2.0 mm in occlusal thickness. CONCLUSION: These results could serve as a theoretic foundation for the clinical application of all-ceramic crown, suggesting that the occlusal thickness of the crown should not be lower than 1.5 mm in order that the resistance of the all-ceramic crown against fracture might be strengthened.

Ceramics↗

[Three-dimensional finite element stress analysis on the periodontal tissue of maxillary canine].

A three-dimensional finite element model of the maxillary canine was developed including periodontal ligament, pulp and alveolar bone. And the stress distributions in the periodontal tissue were obtained under different orthodontic force. The specific aims were to make the model by means of the more advanced and accurate twin CT, to provide more accurate data for clinical use, and to build a more accurate model for the simulation of maxillary canine movement under orthodontic forces.

Cuspid↗

[Posterior glass fiber-reinforced composite resin-bonded fixed partial dentures: A 3-dimensional modeling and finite element numerical analysis].

The method of modeling and mesh generation about 3-unit tooth/restoration complex were established. The three-dimensional finite element models were subjected to four types of occlusal load applied to pontic element to evaluate 3 fiber framework designs and 3 cavities preparation configurations. By comparing the difference of stress distribution, following conclusions were obtained: the principal stress under buccal-lingual cusp load in traditional fiber framework pontic increased by 6.22% compared to that in pure composite resin pontic; optimized fiber framework obviously reduced stress level under any load; modified cavities exhibited better stress transfer and decreased share stress at adhesive interface than traditional cavities.

Composite Resins↗

Study of finite element modeling from CT images.

The use of finite element analysis is becoming more widespread with rapid advancements in computer technology. However, the field of dentistry is not enjoying the spillover benefits of the expanded use of this design simulation and analysis tool. Finite element modeling requires measurement of the object. However, as the living body is morphologically very complex, this requires a great deal of both time and skill using CAD applications, thus preventing its widespread adoption in the dental field. Although there have been reports of finite element modeling from CT images, these methods require skilled programmers for software development--which is another factor that prevents its widespread adoption in dentistry. Therefore, establishing a finite element modeling method that is both accurate and practical will be of great benefit in clinical dentistry. In the present study, a method using computer tomography and existing software was examined for finite element model construction based on computer tomography images. The results suggested that the method developed here is feasible and practical for clinical use.

Bite Force↗