Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Elbow Prosthesis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39Linked to original sources

Utilization of upper limb joint replacements during 1972-90: the Mayo Clinic experience.

Increasing application of expensive medical technologies, including joint replacement, is of concern in the current economic climate. Successful upper limb joint replacements (ULJRs) are being performed, but few detailed data about their utilization are available. To explore the resource implications of such surgery, the utilization of total shoulder replacement (TSR), total elbow replacement (TER) and total wrist replacement (TWR) were examined from the time these procedures first became available at the Mayo Clinic up to 1990. The age- and sex-adjusted utilization rate for TSR among Olmsted County, Minnesota, residents was 1.8 per 100,000 person-years (p-y), 0.8 per 100,000 p-y for TER and 1.1 per 100,000 p-y for TWR. Overall utilization of primary ULJR among Olmsted County residents during the 19-year study period was 3.8 per 100,000 p-y. The commonest indication for TSR was osteoarthritis (46 per cent) and for TER and TWR was rheumatoid arthritis (50 and 81 per cent respectively). There was no consistent trend in the utilization of these procedures among Olmsted County residents, but the number of referral patients receiving a ULJR at the Mayo Clinic increased steadily during the study period. The Mayo Clinic experience suggests an increasing demand for ULJR, particularly TSR and TER. With continued advances in, and diffusion of, the technology this demand may increase further.

Adult↗

Comparison of two types of ulnar component in type-5 Kudo total elbow arthroplasty in patients with rheumatoid arthritis: a long-term follow-up.

The purpose of this study was to assess the long-term results (more than ten years) of two types of cemented ulnar component with type-5 Kudo total elbow arthroplasty in a consecutive series of 56 patients (60 elbows) with rheumatoid arthritis, and to compare the results in elbows above and below a Larsen grade IV. There was no radiolucency around the humeral component. Patients in whom a metal-backed ulnar component and a porous-coated stem were used had better clinical results and significantly less progression of radiolucent line formation around the ulnar component. They also had a significantly better long-term survival than patients with an all-polyethylene ulnar component. The clinical results of arthroplasty using all-polyethylene ulnar components were inferior, regardless of the degree of joint destruction. We conclude that the type-5 Kudo total elbow arthroplasty with cementless fixation of the porous-coated humeral component and cemented fixation of a metal-backed ulnar component is acceptable and well-tolerated by rheumatoid patients.

Adult↗

Metallic radial head arthroplasty improves valgus stability of the elbow.

The stabilizing influence of radial head arthroplasty was studied in eight medial collateral ligament deficient anatomic specimen elbows. An elbow testing apparatus, which used computer controlled pneumatic actuators to apply tendon loading, was used to simulate active elbow flexion. The motion pathways of the elbow were measured using an electromagnetic tracking device, with the forearm in supination and pronation. As a measure of stability, the maximum varus to valgus laxity over the range of elbow flexion was determined from the difference between varus and valgus gravity loaded motion pathways. After transection of the medial collateral ligament, the radial head was excised and replaced with either a silicone or one of three metallic radial head prostheses. Medial collateral ligament transection caused a significant increase in the maximum varus to valgus laxity to 18.0 degrees +/- 3.2 degrees. After radial head excision, this laxity increased to 35.6 degrees +/- 10.3 degrees. The silicone implant conferred no increase in elbow stability, with a maximum varus to valgus laxity of 32.5 degrees +/- 15.5 degrees. All three metallic implants improved the valgus stability of the medial collateral ligament deficient elbow, providing stability similar to the intact radial head. The use of silicone arthroplasty to replace the radial head in the medial collateral ligament deficient elbow must be questioned. Metallic radial head arthroplasty provides improved valgus stability, approaching that of an intact radial head.

Aged↗

Salvage of non-union of supracondylar fracture of the humerus by total elbow arthroplasty.

Fourteen patients in whom open reduction and internal fixation could not be achieved satisfactorily had a total elbow arthroplasty for non-union of a supracondylar humeral fracture. All patients had an established non-union, and ten had had from one to four previous attempts at internal fixation. The average age at the time of operation was sixty-five years. The average duration of follow-up was five years, with a minimum of two years. The average preoperative elbow score was 17 points, with both pain and functional disability present. The average postoperative score was 84 points; there were eight good or excellent results and three failures. The latter three patients had an additional operation: one each for dislocation, loosening of the humeral component, and deep infection. Salvage of supracondylar non-union by means of a total elbow arthroplasty is a technically demanding procedure. Strict indications for selection of patients must be followed. A semiconstrained implant is recommended, with preservation of the epicondyles and their muscular attachments in order to achieve balance of the soft tissues.

Adult↗

[Endoprosthetic surgery of the elbow].

Artificial joint replacement has found a firm place in orthopaedic surgery since its first introduction in the late 1960s. While the initial fixed bearing implants tended to progress to early loosening, the development of so-called "sloppy joints" has seen a major advance in the survival and success rate of this arthroplasty. The surgical approach and technique have also been modified in such a way as to allow a complete ventral release of a flexion contracture, while at the same time preserving the integrity of the extensor mechanism. In this way, the improvement of the biomechanics of the implant combined with diligent surgical technique have enhanced this procedure dramatically. Between 1978 and 1999, 305 GSB 3-type prosthesis were implanted, with the underlying pathologies being rheumatoid arthritis (77%), posttraumatic arthritis (21%) and degenerative arthritis (2%). The range of motion could be significantly improved from the pre-operative state for extension as well as flexion. This was even more obvious in the rheumatoid than in the posttraumatic situation. The survival rate for this type of implant was 90% at 10 years, with the implants after rheumatoid surgery faring somewhat better than those of the posttraumatics. Alternative treatment options, such as resection arthroplasty, distraction arthroplasty, or arthrodesis, are nowadays employed only in rare cases where a previous infection, personal preference or an inability by the patient to co-operate in a rehabilitation program have to be considered. The overall functional results of these types of treatments seem to be inferior to that of elbow arthroplasty. Therefore, this procedure is recommended not only for advanced degenerative and rheumatoid pathologies, but also in cases of posttraumatic arthrosis.

Arthritis↗

Combined subclavian artery and brachial plexus injuries from blunt upper-extremity trauma.

Four cases of blunt upper extremity trauma producing subclavian artery and brachial plexus injuries are presented. In each case the patient was hemodynamically stable and arteriography demonstrated the subclavian lesion. Arterial reconstruction was successfully accomplished in three cases, but no use of the injured limb was regained by any patient. Early arterial repair may still be indicated to allow later above-elbow amputation for the purpose of functional rehabilitation.

Adult↗

Capitellocondylar total elbow arthroplasty.

Sixty-nine non-constrained capitellocondylar metal-to-plastic total elbow-replacement prostheses were implanted in sixty-four patients with rheumatoid arthritis. These patients were followed for an average of 3.5 years. Postoperative flexion and pronation were significantly improved, but no significant increase in postoperative extension or supination could be demonstrated. Based on a rating system evaluating pain and function, there were 87 per cent good or excellent results. The complication rate based on the total number of prostheses implanted was 39 per cent. Eight patients required revision of the arthroplasty: four for dislocation of the prosthesis, two for sepsis, one for loosening, and one for a fracture. Eight other asymptomatic patients showed minimum radiolucent lines adjacent to the ulnar component. No patient demonstrated radiolucent lines adjacent to the humeral component.

Adolescent↗

Clinical application study of externally powered upper-limb prosthetics systems: the VA elbow, the VA hand, and the VA/NU myoelectric hand systems.

The results have been presented of a 2-year survey designed to determine whether external power systems offer a significant contribution to the needs of the upper-limb amputee or whether they represent novelties duplicating the functions of conventional mechanical components. The following conclusions have been drawn: 1. External power does offer advantages to the arm amputee. Myoelectric control, especially combined with a self-suspending socket, offers an otherwise normal partial forearm amputee better function without the necessity of a harness. External power, especially for the short partial or total arm amputee and others with limited excursion, brings increased function with less effort. For these patients the advantages of such components as the electric elbow outweigh the recent disadvantages. 2. The components evaluated in this Study are not without limitations. Maintenance requirements of the VA Elbow were excessive. The VA Elbow should not be prescribed for patients who do heavy work with their prostheses because the flexspline may break. Regarding such concerns as lack of sensory feedback, noise, weight, and flexion/extension speed, the advantages of each unit must be weighed against the disadvantages with preference to the individual amputee. 3. The endoskeletal forearm with soft cover is an advantage because of its lightness and cosmesis. 4. Because of the many malfunctions attributed to prosthetist errors, the need is evident for thorough specialized education in the field of external power. A few centralized fabrication facilities may be desirable as opposed to fabrication by many facilities with limited experience. Modular components that are interchangeable and field repairable would be desirable. The systems should be fitted, installed and repaired only by trained prosthetists who have successfully completed a course in externally powered upper-limb prostheses. All members of the Clinic Team should be thoroughly educated in external power as it is related to prosthetics. 5. Many malfunctions were due to patient misuse. Patients, too, after careful selection must be given thorough training in the care and use of externally powered components, including the limitations and capabilities of these devices. 6. Finally, and most important, the Clinic Team must be recognized as the focal point for the selection of patients and prescription of devices. Each patient must be carefully screened for information such as occupation, motivation, prosthesis use (as opposed to wear), ability to learn and follow through with instructions (charging batteries, etc.), and most importantly, the benefits that external power can offer.

Adolescent↗

Amputation rehabilitation and prosthetic restoration. From surgery to community reintegration.

PURPOSE: The purpose of this review is to summarize the literature related to the advances that have taken place in the management and rehabilitation care of limb amputation. RESULTS: Prostheses for the lower and upper limb amputee have changed greatly over the past several years, with advances in components, socket fabrication and fitting techniques, suspension systems and sources of power and electronic controls. Higher levels of limb amputation can now be fitted with functional prostheses, which allow more patients to achieve independent life styles. This is of particular importance for the multi-limb amputee. The rehabilitation of more traditional lower limb levels of amputation have also greatly benefited from the technological advances including energy storing feet, electronic control hydraulic knees, ankle rotators and shock absorbers to mention a few. For the upper limb amputee, myoelectric and proportional controlled terminal devices and elbow joints are now used routinely in some rehabilitation facilities. Experimental prosthetic fitting techniques and devices such as the use of osseo-implantation for suspension of the prosthesis, tension control hands or electromagnetic fluids for knee movement control will also be briefly discussed in this paper. CONCLUSION: It is possible to conclude from this review that many advances have occurred that have greatly impacted the functional outcomes of patients with limb amputation.

Adaptation, Physiological↗

A two-input sliding-mode controller for a planar arm actuated by four pneumatic muscle groups.

Multiple-input sliding-mode techniques are applied to a planar arm actuated by four groups of pneumatic muscle (PM) actuators in opposing pair configuration. The control objective is end-effector tracking of a desired path in Cartesian space. The inputs to the system are commanded input pressure differentials for the two opposing PM groups. An existing model for the muscle is incorporated into the arm equations of motion to arrive at a two-input, two-output nonlinear model of the planar arm that is affine in the input and, therefore, suitable for sliding-mode techniques. Relationships between static input pressures are derived for suitable arm behavior in the absence of a control signal. Simulation studies are reported.

Arm↗

Impaction grafting in revision total elbow arthroplasty.

BACKGROUND: Revision total elbow arthroplasty is often undertaken in patients who have severe osteolysis of both the distal part of the humerus and the proximal part of the ulna. To deal with such bone loss, we have adopted the practice of impaction grafting, which has become a well-established technique in the proximal part of the femur. METHODS: We retrospectively reviewed the results of twelve patients who had undergone revision total elbow arthroplasty with impaction grafting between 1993 and 1997. There were eight women and four men with a mean age of fifty-seven years. All patients were followed for at least two years (range, twenty-five to 113 months), with an average duration of follow-up of seventy-two months. Seven of the patients had an initial diagnosis of rheumatoid arthritis, and five had posttraumatic arthritis. Impaction grafting was undertaken during the initial revision in three of the patients, whereas the remaining nine patients had undergone at least one prior revision without impaction grafting. Four patients had impaction grafting on the ulnar side alone, six had it on the humeral side alone, and two underwent impaction grafting of both the humerus and the ulna. Six allograft struts were placed to span structural defects in five patients. RESULTS: At the time of the latest follow-up, eight of the elbow prostheses were intact after the index impaction grafting procedure. Two elbows had been revised because of loosening, and another had been revised because of a fracture of the ulnar component. A fourth patient had undergone a resection arthroplasty because of infection. The eight remaining patients demonstrated marked radiographic improvement in bone quality in the region of the impaction graft without clinical symptoms of loosening. At the time of the last follow-up, after an additional revision in three elbows, there were five excellent, four good, and three fair results. CONCLUSIONS: Impaction grafting is a reliable technique for treating osteolysis in patients undergoing revision total elbow arthroplasty; however, complications can occur, and a high percentage of patients need additional surgery.

Arthritis, Rheumatoid↗