Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Cadmium Compounds”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39Linked to original sources

Recognition of hypermethylated triplet repeats in vitro by cationic nanoparticles.

Genomic DNA contains many higher-order structural deviations from the Watson-Crick global average. The massive expansion and hypermethylation of the duplex triplet repeat (CCG)(n)(CGG)(n) has characteristic higher-order structures that are associated with the fragile X syndrome. We have used luminescent mineral nanoparticles of protein-sized cadmium sulfide in optical assays to detect anomalous DNA structures. The photoluminescence of these particles is sensitive to the presence and nature of adsorbates. We previously found that our nanoparticles bind the fragile X repeat well but do not bind to normal double-helical DNA. In this study, we have determined that these particles are also able to detect the hypermethylated forms of these triplet repeats. Therefore, these nanoparticles may form the basis for future optical assays of higher-order DNA structures, especially those associated with human disease.

Base Sequence↗

Thin CdTe detector in diagnostic x-ray spectroscopy.

A CdTe Schottky diode detector of 1 mm thickness was employed in diagnostic x-ray spectroscopy. The detector response to monoenergetic photons was investigated with gamma rays from the calibration sources (241Am and 133Ba). As spectral distortion due to carrier trapping, known as tailing, was small in gamma-ray spectra, the effects of carrier trapping were not taken into account in the calculation of response functions. The distortion due to the transmission of primary x rays and the escape of secondary x rays (K-fluorescent x rays and Compton-scattered x rays) from the crystal was included in the calculated response functions. X-ray spectra corrected using the response functions were in good agreement with the reference spectra obtained with a high-purity germanium detector. The results indicated that correction for the distortion due to carrier trapping is not necessary when using a thin CdTe detector in diagnostic x-ray spectroscopy.

Cadmium Compounds↗

SemiSPECT: a small-animal single-photon emission computed tomography (SPECT) imager based on eight cadmium zinc telluride (CZT) detector arrays.

The first full single-photon emission computed tomography (SPECT) imager to exploit eight compact high-intrinsic-resolution cadmium zinc telluride (CZT) detectors, called SemiSPECT, has been completed. Each detector consists of a CZT crystal and a customized application-specific integrated circuit (ASIC). The CZT crystal is a 2.7 cm x 2.7 cm x -0.2 cm slab with a continuous top electrode and a bottom electrode patterned into a 64 x 64 pixel array by photolithography. The ASIC is attached to the bottom of the CZT crystal by indium-bump bonding. A bias voltage of -180 V is applied to the continuous electrode. The eight detectors are arranged in an octagonal lead-shielded ring. Each pinhole in the eight-pinhole aperture placed at the center of the ring is matched to each individual detector array. An object is imaged onto each detector through a pinhole, and each detector is operated independently with list-mode acquisition. The imaging subject can be rotated about a vertical axis to obtain additional angular projections. The performance of SemiSPECT was characterized using 99mTc. When a 0.5 mm diameter pinhole is used, the spatial resolution on each axis is about 1.4 mm as estimated by the Fourier crosstalk matrix, which provides an algorithm-independent average resolution over the field of view. The energy resolution achieved by summing neighboring pixel signals in a 3 x 3 window is about 10% full-width-at-half-maximum of the photopeak. The overall system sensitivity is about 0.5 x 10(-4) with the energy window of +/-10% from the photopeak. Line-phantom images are presented to visualize the spatial resolution provided by SemiSPECT, and images of bone, myocardium, and human tumor xenografts in mice demonstrate the feasibility of preclinical small-animal studies with SemiSPECT.

Animals↗

An analytic model for the response of a CZT detector in diagnostic energy dispersive x-ray spectroscopy.

A CdZnTe detector (CZTD) can be very useful for measuring diagnostic x-ray spectra. The semiconductor detector does, however, exhibit poor hole transport properties and fluorescence generation upon atomic de-excitations. This article describes an analytic model to characterize these two phenomena that occur when a CZTD is exposed to diagnostic x rays. The analytical detector response functions compare well with those obtained via Monte Carlo calculations. The response functions were applied to 50, 80, and 110 kV x-ray spectra. Two 50 kV spectra were measured; one with no filtration and the other with 1.35 mm Al filtration. The unfiltered spectrum was numerically filtered with 1.35 mm of Al in order to see whether the recovered spectrum resembled the filtered spectrum actually measured. A deviation curve was obtained by subtracting one curve from the other on an energy bin by bin basis. The deviation pattern fluctuated around the zero line when corrections were applied to both spectra. Significant deviations from zero towards the lower energies were observed when the uncorrected spectra were used. Beside visual observations, the exposure obtained using the numerically attenuated unfiltered beam was compared to the exposure calculated with the actual filtered beam. The percent differences were 0.8% when corrections were applied and 25% for no corrections. The model can be used to correct diagnostic x-ray spectra measured with a CdZnTe detector.

Algorithms↗

High-resolution digital x-ray detector utilizing a discrete array of CdWO4 scintillators and a self-scanned photodiode array.

A high-resolution x-ray detector array for x-ray imaging is described. It consists of a discrete array of CdWO4 scintillators and a Reticon 1024S photodiode array with a fiber-optic faceplate. The scintillator elements measure 0.099 X 3 X 4 mm and are bonded together with aluminum foil separators to minimize light crossover. Detective quantum efficiency (DQE) of individual detector channels was 0.38. Systematic variations between channels were substantial. With only a simple correction for between channel variations, DQE for the entire array was 0.04. Evaluation of the edge response function of the array showed that resolution is similar to a detector whose line spread function is Gaussian with a standard deviation of 0.172 mm.

Cadmium↗

Comparison of NaI(T1), CdTe, and HgI2 surgical probes: effect of scatter compensation on probe performance.

Spatial variation in the background source distribution makes tumor detection difficult for single-detector probes. Using a single energy window that brackets the photopeak helps discriminate against background events dominated by Compton scattering. Another approach is to use the information provided by an additional window in the Compton region. The performances of NaI(T1), CdTe, and HgI2 surgical probes have been compared under realistic simulations of a tumor-staging procedure using optimal single-sided energy windows and a two-window scatter-subtraction technique. Results showed that despite the differences in energy resolution of the detectors, the performances of the probes in a variable background were similar when optimal single energy windows were used. When the background variations were large, using information provided by a second window improved probe performance.

Cadmium↗

Comparison of NaI(Tl), CdTe, and HgI2 surgical probes: physical characterization.

The physical properties of three surgical probes containing different radiation detectors are compared: a NaI(Tl) scintillator with a flexible, fiber-optic light guide, and two semiconductor detectors that operate at room temperature, CdTe and HgI2. Also compared are spectra, energy resolutions, and counting efficiencies measured at a variety of gamma-ray energies between 30 and 1000 keV. The energy resolution of the NaI probe is substantially poorer than that of either semiconductor probe due in part to light losses in coupling the scintillator to the fiber optics. The semiconductor probes have complex spectral response due to charge-carrier trapping and K x-ray escape, and not all photoelectric interactions in these detectors contribute to the useful part of the photopeak. Above 120 keV the counting efficiency for the NaI probe is an order of magnitude higher than for the CdTe and HgI2 probes. Both energy resolution and counting efficiency are slightly better for the HgI2 probe than for the CdTe probe.

Cadmium↗

Digital radiology using active matrix readout of amorphous selenium: radiation hardness of cadmium selenide thin film transistors.

A flat-panel x-ray imaging detector using active matrix readout of amorphous selenium (a-Se) is being investigated for digital radiography and fluoroscopy. The active matrix consists of a two-dimensional array of thin film transistors (TFTs). Radiation penetrating through the a-Se layer will interact with the TFTs and it is important to ensure that radiation induced changes will not affect the operation of the x-ray imaging detector. The methodology of the present work is to investigate the effects of radiation on the characteristic curves of the TFTs using individual TFT samples made with cadmium selenide (CdSe) semiconductor. Four characteristic parameters, i.e., threshold voltage, subthreshold swing, field effect mobility, and leakage current, were examined. This choice of parameters was based on the well established radiation damage mechanisms for crystalline silicon metal-oxide-semiconductor field-effect transistors (MOSFETs), which have a similar principle of operation as CdSe TFTs. It was found that radiation had no measurable effect on the leakage current and the field effect mobility. However, radiation shifted the threshold voltage and increased the subthreshold swing. But even the estimated lifetime dose (50 Gy) of a diagnostic radiation detector will not affect the normal operation of an active matrix x-ray detector made with CdSe TFTs. The mechanisms of the effects of radiation will be discussed and compared with those for MOSFETs and hydrogenated amorphous silicon (a-Si:H) TFTs.

Cadmium Compounds↗

Signal formation and decay in CdTe x-ray detectors under intense irradiation.

The response of Cd(Zn)Te Schottky and resistive detectors to intense x-rays is investigated in a commercial computed tomography (CT) system to assess their potential for medical diagnostics. To describe their signal height, responsivity, signal-to-noise ratio (SNR), and detective quantum efficiency the devices are modeled as solid-state ionization chambers with spatially varying electric field and charge collection efficiency. The thicknesses and pixel areas of the discrete detector elements are 0.5-2 mm and a few mm2, respectively. The incident spectrum extends from 26 to 120 keV and comprises 10(10) quanta/s cm2. It photogenerates a carrier concentration in the semiconductor that is two to three orders of magnitude above the intrinsic concentration, but remains to a similar extent below the charge densities on the device electrodes. Stable linear operation is achieved with the Schottky-type devices under high bias. Their behavior can be modeled well if negatively charged near-midgap bulk defects with a concentration of 10(11)-10(13) cm-3 are assumed. The bulk defects explain the amount and time constant (about 100 ms) of the detrapping current measured after x-ray pulses (afterglow). To avoid screening by the trapped space charge the bias voltage should exceed 100(V) x [detector thickness/mm]2. Dark currents are of the order of the generation-recombination current, i.e., 300 pA/mm3 detector volume. With proper device design the signal height approaches the theoretical maximum of 0.2 A/W. This high responsivity, however, is not exploited in CT since the SNR is determined here by the incident quantum noise. As a consequence of the detrapping current, the response speed does not meet CT requirements. A medium-term effort for crystal growth appears necessary to achieve the required reduction of the trap density by an order of magnitude. Scintillation based detectors are, therefore, still preferred in fast operating medical diagnostic systems.

Cadmium Compounds↗

Molecular rulers for scaling down nanostructures.

A method of constructing <30-nanometer structures in close proximity with precise spacings is presented that uses the step-by-step application of organic molecules and metal ions as size-controlled resists on predetermined patterns, such as those formed by electron-beam lithography. The organic molecules serve as a ruler for scaling down a larger "parent" structure. After metal deposition and lift-off of the organic multilayer resist, an isolated smaller structure remains on the surface. This approach is used to form thin parallel wires (15 to 70 nanometers in width and 1 micrometer long) of controlled thickness and spacing. The structures obtained were imaged with field emission scanning electron microscopy. A variety of nanostructures could be scaled down, including structures with hollow patterns.

Journal Article↗

Linearly polarized emission from colloidal semiconductor quantum rods.

Colloidal quantum rods of cadmium selenide (CdSe) exhibit linearly polarized emission. Empirical pseudopotential calculations predict that slightly elongated CdSe nanocrystals have polarized emission along the long axis, unlike spherical dots, which emit plane-polarized light. Single-molecule luminescence spectroscopy measurements on CdSe quantum rods with an aspect ratio between 1 and 30 confirm a sharp transition from nonpolarized to purely linearly polarized emission at an aspect ratio of 2. Linearly polarized luminescent chromophores are highly desirable in a variety of applications.

Cadmium Compounds↗

Water-soluble quantum dots for multiphoton fluorescence imaging in vivo.

The use of semiconductor nanocrystals (quantum dots) as fluorescent labels for multiphoton microscopy enables multicolor imaging in demanding biological environments such as living tissue. We characterized water-soluble cadmium selenide-zinc sulfide quantum dots for multiphoton imaging in live animals. These fluorescent probes have two-photon action cross sections as high as 47,000 Goeppert-Mayer units, by far the largest of any label used in multiphoton microscopy. We visualized quantum dots dynamically through the skin of living mice, in capillaries hundreds of micrometers deep. We found no evidence of blinking (fluorescence intermittency) in solution on nanosecond to millisecond time scales.

Adipose Tissue↗

Virus-based toolkit for the directed synthesis of magnetic and semiconducting nanowires.

We report a virus-based scaffold for the synthesis of single-crystal ZnS, CdS, and freestanding chemically ordered CoPt and FePt nanowires, with the means of modifying substrate specificity through standard biological methods. Peptides (selected through an evolutionary screening process) that exhibit control of composition, size, and phase during nanoparticle nucleation have been expressed on the highly ordered filamentous capsid of the M13 bacteriophage. The incorporation of specific, nucleating peptides into the generic scaffold of the M13 coat structure provides a viable template for the directed synthesis of semiconducting and magnetic materials. Removal of the viral template by means of annealing promoted oriented aggregation-based crystal growth, forming individual crystalline nanowires. The unique ability to interchange substrate-specific peptides into the linear self-assembled filamentous construct of the M13 virus introduces a material tunability that has not been seen in previous synthetic routes. Therefore, this system provides a genetic toolkit for growing and organizing nanowires from semiconducting and magnetic materials.

Alloys↗

The roles of the subunits in the function of the calcium channel.

Dihydropyridine-sensitive voltage-dependent L-type calcium channels are critical to excitation-secretion and excitation-contraction coupling. The channel molecule is a complex of the main, pore-forming subunit alpha 1 and four additional subunits: alpha 2, delta, beta, and gamma (alpha 2 and delta are encoded by a single messenger RNA). The alpha 1 subunit messenger RNA alone directs expression of functional calcium channels in Xenopus oocytes, and coexpression of the alpha 2/delta and beta subunits enhances the amplitude of the current. The alpha 2, delta, and gamma subunits also have pronounced effects on its macroscopic characteristics, such as kinetics, voltage dependence of activation and inactivation, and enhancement by a dihydropyridine agonist. In some cases, specific modulatory functions can be assigned to individual subunits, whereas in other cases the different subunits appear to act in concert to modulate the properties of the channel.

3-Pyridinecarboxylic acid, 1,4-dihydro-2,6-dimethy↗

Semiconductor nanocrystals as fluorescent biological labels.

Semiconductor nanocrystals were prepared for use as fluorescent probes in biological staining and diagnostics. Compared with conventional fluorophores, the nanocrystals have a narrow, tunable, symmetric emission spectrum and are photochemically stable. The advantages of the broad, continuous excitation spectrum were demonstrated in a dual-emission, single-excitation labeling experiment on mouse fibroblasts. These nanocrystal probes are thus complementary and in some cases may be superior to existing fluorophores.

3T3 Cells↗

Quantum dot bioconjugates for ultrasensitive nonisotopic detection.

Highly luminescent semiconductor quantum dots (zinc sulfide-capped cadmium selenide) have been covalently coupled to biomolecules for use in ultrasensitive biological detection. In comparison with organic dyes such as rhodamine, this class of luminescent labels is 20 times as bright, 100 times as stable against photobleaching, and one-third as wide in spectral linewidth. These nanometer-sized conjugates are water-soluble and biocompatible. Quantum dots that were labeled with the protein transferrin underwent receptor-mediated endocytosis in cultured HeLa cells, and those dots that were labeled with immunomolecules recognized specific antibodies or antigens.

Cadmium Compounds↗

Quantum-dot-based cell motility assay.

Because of their favorable physical and photochemical properties, colloidal CdSe/ZnS-semiconductor nanocrystals (commonly known as quantum dots) have enormous potential for use in biological imaging. In this report, we present an assay that uses quantum dots as markers to quantify cell motility. Cells that are seeded onto a homogeneous layer of quantum dots engulf and absorb the nanocrystals and, as a consequence, leave behind a fluorescence-free trail. By subsequently determining the ratio of cell area to fluorescence-free track area, we show that it is possible to differentiate between invasive and noninvasive cancer cells. Because this assay uses simple fluorescence detection, requires no significant data processing, and can be used in live-cell studies, it has the potential to be a powerful new tool for discriminating between invasive and noninvasive cancer cell lines or for studying cell signaling events involved in migration.

Adenocarcinoma↗

Metabolic engineering of an aerobic sulfate reduction pathway and its application to precipitation of cadmium on the cell surface.

The conversion of sulfate to an excess of free sulfide requires stringent reductive conditions. Dissimilatory sulfate reduction is used in nature by sulfate-reducing bacteria for respiration and results in the conversion of sulfate to sulfide. However, this dissimilatory sulfate reduction pathway is inhibited by oxygen and is thus limited to anaerobic environments. As an alternative, we have metabolically engineered a novel aerobic sulfate reduction pathway for the secretion of sulfides. The assimilatory sulfate reduction pathway was redirected to overproduce cysteine, and excess cysteine was converted to sulfide by cysteine desulfhydrase. As a potential application for this pathway, a bacterium was engineered with this pathway and was used to aerobically precipitate cadmium as cadmium sulfide, which was deposited on the cell surface. To maximize sulfide production and cadmium precipitation, the production of cysteine desulfhydrase was modulated to achieve an optimal balance between the production and degradation of cysteine.

Aerobiosis↗