Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CYCLOPLEGICS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39Linked to original sources

Topography-guided laser in situ keratomileusis (TOPOLINK) to correct irregular astigmatism after previous refractive surgery.

PURPOSE: To assess whether topography-driven laser in situ keratomileusis (LASIK) can correct induced corneal irregular astigmatism. METHODS: A prospective non-comparative case series of 41 eyes (38 patients) with irregular astigmatism following corneal refractive surgery, included two groups: Group 1 (26 eyes) with a defined topographic pattern and Group 2 (15 eyes) with no pattern. Ablation was performed using the Technolas 217C excimer laser with a software ablation program (TOPOLINK) based on corneal topography. Uncorrected and best spectacle-corrected visual acuity, manifest and cycloplegic refraction, corneal topography, superficial corneal surface quality, and image distortion were measured. RESULTS: At 6 months follow-up in Group 1 eyes (defined topographic pattern) mean preoperative BSCVA improved from 0.16 +/- 0.11 LogMAR (0.4 to 0) to 0.09 +/- 0.10 LogMAR (0.2 to 0) (P = .001) (safety index of 1.1). In Group 2 eyes (no pattern), mean preoperative BSCVA was 0.18 +/- 0.11 LogMAR (0.4 to 0), similar to the postoperative BSCVA of 0.17 +/- 0.10 LogMAR (0.3 to 0) (safety index of 0.98). Mean postoperative UCVA was > or = 0.3 LogMAR in 25 eyes (96.2%) in Group 1 (efficacy index of 0.8) and 7 eyes (46.6%) in Group 2 (efficacy index of 0.5). Both superficial corneal surface quality and image distortion significantly improved in Group 1; there were no significant changes in Group 2. We reoperated nine eyes (21.9%). CONCLUSIONS: Topographic-assisted LASIK was helpful in selected cases where irregular astigmatism showed a pattern. It was ineffective in undefined irregular astigmatism. Partial correction of the irregularity and regression of the obtained effect was common.

Adult↗

Wavefront-guided treatment for previous laser in situ keratomileusis and photorefractive keratectomy: case reports.

PURPOSE: To describe the off-label use of the Alcon LADARVision System for CustomCornea (LADARWave and LADARVision4000) in two patients, one for retreatment after laser in situ keratomileusis (LASIK) and one for retreatment after photorefractive keratectomy (PRK). METHODS AND RESULTS: Both patients were unhappy with the quality of their vision after initial refractive surgery. The first patient initially had LASIK to correct -4.75 D of myopia in each eye, and then had retreatment with CustomCornea. Before retreatment, manifest refraction was OD 0.50 -0.50 x 180 degrees (20/25 uncorrected) and OS -0.50 -0.75 x 180 degrees (20/40 uncorrected). Two months after retreatment with CustomCornea, his uncorrected visual acuity OD was 20/15, and 1 month after retreatment in his left eye, uncorrected visual acuity was 20/15. The second patient had PRK OD, with a postoperative uncorrected visual acuity of 20/25 and cycloplegic refraction of +1.00 -0.75 x 84 degrees. After CustomCornea retreatment, his 3.5-month postoperative uncorrected visual acuity was 20/15 and manifest refraction was +0.50 -0.50 x 180 degrees. CONCLUSION: The Alcon LADARVision System for CustomCornea was used effectively to retreat both a myopic LASIK and myopic PRK patient, primarily for subjective quality of night vision complaints.

Adult↗

Diode laser thermal keratoplasty to correct hyperopia.

PURPOSE: We investigated long-term efficacy, predictability, stability, and safety of diode laser thermal keratoplasty (DTK) to correct hyperopia. METHODS: DTK was performed on 24 eyes (18 patients). Eight eyes with high hyperopia (mean +4.75 +/- 0.63 D; range +3.50 to +5.50 D) received 12 pairs of coagulation spots at 6-mm and 7-mm treatment zone diameters; eight eyes with low hyperopia (mean +2.25 +/- 0.40 D; range +1.50 to +2.75 D) received eight coagulation spots at 8 mm, and eight eyes with low hyperopia (mean +1.50 +/- 0.46 D; range +1.25 to +2.25 D) were treated to induce mild myopia (-1.50 D) in the non-dominant eye for monovision using eight pairs of spots at 7 and 8-mm diameters. Minimum follow-up was 18 months. RESULTS: Mean decrease in cycloplegic refraction at 18 months was 5.00 +/- 0.38 D in the high hyperopia group, 1.75 +/- 0.19 D in the low hyperopia group, and 3.25 +/- 0.27 D in the presbyopia group. Mean increase in uncorrected visual acuity (UCVA) at 18 months was 8.125 +/- 2.1 Snellen lines in the high hyperopia group, 6.625 +/- 0.744 lines for low hyperopia; decrease of 1.00 +/- 1.85 line occurred in the presbyopia group. Near UCVA in the presbyopia group improved by 3.875 +/- 0.83 Jaeger lines. Best spectacle-corrected visual acuity (BSCVA) was restored by 3 months in all eyes. CONCLUSION: DTK was an effective and fairly safe procedure, with reasonable predictability and stability. Nomograms for laser energy level, treatment zone diameter, and number of spots need improvement.

Adult↗

Videokeratography in conductive keratoplasty.

PURPOSE: We used EyeSys videokeratography to evaluate corneal shape changes induced by conductive keratoplasty, a procedure that utilizes radio frequency energy to alter corneal shape to correct hyperopia. METHODS: Follow-up data were available for 19 eyes (out of 24 eyes of 13 patients). Preoperative spherical hyperopia ranged from +0.75 to +3.25 D with astigmatism <0.75 D. Manifest refractive spherical equivalent refraction (MRSE), uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), topographical parameter predicted corneal acuity (PCA), corneal uniformity index (CU Index), regular astigmatism, total astigmatism, average simulated keratometry (Avg Sim K), effective refractive power, and asphericity were measured preoperatively and at 6 and 12 months postoperatively. RESULTS: Twelve months postoperatively, mean PCA, CU Index, and BSCVA were maintained at preoperative levels. Mean UCVA (LogMAR) improved from 0.53+/-0.21 to 0.10+/-0.19 (P<.05) with a mean MRSE change from +1.62+/-0.76 D to -0.06+/-0.84 D (P<.05) from preoperative to 12 months postoperative. Mean asphericity increased +0.044+/-0.24 D (P>.05), mean Avg Sim K increased 1.88+/-0.72 D (P<.05), mean effective refractive power increased 1.71+/-0.79 D (P<.05), mean cylinder (cycloplegic refraction) increased 0.19+/-0.36 D (P<.05), mean regular astigmatism increased 0.25+/-0.49 D (P>.05), and mean irregular astigmatism decreased 0.01+/-0.13 D (P>.05) from preoperative to 12 months after conductive keratoplasty. CONCLUSIONS: Avg Sim K and effective refractive power changes support the refractive results; 12-month postoperative maintenance of BSCVA, PCA, and CU Index suggest the procedure is safe. Conductive keratoplasty induced a slight regular astigmatism in some eyes, which decreased with time. The increase in mean corneal asphericity indicated possible induction of central and peripheral cornea changes.

Adult↗

Correction of myopia of 7 to 24 diopters with the Artisan phakic intraocular lens: two-year follow-up.

PURPOSE: To evaluate the safety and efficacy of the iris claw phakic intraocular lens (Artisan; Ophtec BV, Groningen, The Netherlands) in patients with high myopia. METHODS: Between May 1999 and July 2001, 93 Artisan phakic intraocular lenses (IOLs) were implanted in 60 patients affected by high myopia. All patients underwent 24-month follow-up. The power of the lenses ranged from -7.5 to -22.0 diopters (D). Patients were divided into two groups: group 1 (68 eyes), myopia -6.75 to -15.50 D (SE), and group 2 (25 eyes), myopia -16.0 to -23.0 D (SE). Pre- and postoperative patient evaluation included manifest and cycloplegic refractions, uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), endothelial cell count, intraocular pressure, complication rate, safety, and efficacy. RESULTS: At 4 months, 83.8% (57/68) (group 1, myopia -6.75 to -15.50 D) and 68% (17/25) (group 2, myopia -16.0 to -23.0 D) of eyes achieved UCVA of > or =20/40. The BSCVA remained the same or improved in 100% of eyes. After 4 months, 69.1% (47/68) of eyes in group 1 and 52% (13/25) of eyes in group 2 were within +/-1.00 D of the desired refraction; the mean refraction was stable between 4 and 24 months. Of the intraoperative complications, 69.2% were observed in the first 25 lenses implanted; postoperative complications included iris atrophy in 11.8% (11/93), lens decentration in 5.4% (5/93), and night glare in 6.4% (6/93) of eyes. No IOLs were removed. Mean endothelial cell loss was 2.8% at 4 months, 3.9% at 12 months, and 5.4% at 24 months. CONCLUSIONS: Our results regarding implantation of the Artisan phakic IOL confirm that these lenses are safe and effective for the correction of high myopia, with a stable refractive outcome but with a higher than normal rate of endothelial cell loss during 2-year follow-up.

Adult↗

Topography-guided treatment of irregular astigmatism with the wavelight excimer laser.

PURPOSE: To evaluate the feasibility, safety, and predictability of correcting high irregular astigmatism in symptomatic eyes with the use of topography-guided photoablation. METHODS: In a prospective, non-comparative case series, 16 consecutive symptomatic eyes of 11 patients with small hyperopic and myopic excimer laser optical zones, decentered and irregular ablation after corneal graft, and corneal scars were operated. Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest and cycloplegic refraction, and corneal topography, with asphericity and regularity, were analyzed. LASIK (n = 10) and photorefractive keratectomy (n = 6) were performed using the ALLEGRETTO WAVE excimer laser and T-CAT software (Topography-guided Customized Ablation Treatment; WaveLight Laser Technologie AG, Erlangen, Germany). RESULTS: In the LASIK group, UCVA improved from 0.81 +/- 0.68 IogMAR (20/130) (range: 0.2 to 2.0) to 0.29 +/- 0.21 logMAR (20/39) (range: 0.1 to 0.7) at 6 months. In the PRK group, mean UCVA improved from 0.89 +/- 0.87 IogMAR (20/157) (range: 0.1 to 2.0) to 0.42 +/- 0.35 logMAR (20/53) (range: 0.1 to 1.0) at 6 months. Best spectacle-corrected visual acuity did not change significantly in either group. One PRK patient lost one line of BSCVA. Refractive cylinder for the LASIK group improved from -2.53 +/- 1.71 diopters (D) (range: -0.75 to -5.75 D) to -1.28 +/- 0.99 D (range: 0 to -2.50 D) at 6 months. Refractive cylinder in the PRK group improved from -2.21 +/- 2.11 D (range: -0.25 to -5.50 D) to -1.10 +/- 0.42 D (range: -0.50 to -1.50 D). Index of surface irregularity showed a decrease from 60 +/- 12 (range: 46 to 89) to 50 +/- 9 (range: 32 to 63) at 6 months in the LASIK group whereas no significant change was noted in the PRK group. Subjective symptoms, such as glare, halos, ghost images, starbursts, and monocular diplopia, were not present postoperatively. CONCLUSIONS: Topography-guided LASIK and PRK resulted in a significant reduction of refractive cylinder and increase of UCVA, without a significant loss of BSCVA.

Adolescent↗

Hyperopic LASIK retreatments with the Technolas laser.

PURPOSE: To evaluate the safety, efficacy, and predictability of hyperopic LASIK retreatments. METHODS: This retrospective, consecutive, non-comparative, observational study included 85 eyes that underwent hyperopic LASIK retreatment with 1-year follow-up. Complete ophthalmic examination included distance uncorrected (UCVA) and best spectacle-corrected visual acuity (BSCVA), cycloplegic refraction, and pachymetry. Patients were divided into two groups according to the preoperative spherical equivalent refraction: group 1, < or = +3.9 diopters (D) and group 2, > or = +4.0 D. RESULTS: The UCVA improved from 0.31 +/- 0.2 to 0.7 +/- 0.2 in group 1 and from 0.2 +/- 0.2 to 0.6 +/- 0.2 in group 2 following retreatment. Mean spherical equivalent refraction improved from +2.8 +/- 0.85 to +0.2 +/- 0.9 in group 1 and from +5.3 +/- 0.9 to +0.3 +/- 1.3 in group 2 after retreatment. In group 1, 32 (72.7%) of 44 eyes had BSCVA > or = 20/25, and in group 2, 24 (58.5%) of 41 eyes had BSCVA > or = 20/25. After primary hyperopic LASIK, 25 (56.8%) of 44 eyes in group 1 and 19 (46.3%) of 41 eyes in group 2 maintained BSCVA or gained > or = 1 lines postoperatively in contrast to 21 (47.7%) of 44 eyes in group 1 and 22 (53.9%) of 41 eyes in group 2 after retreatment. In group 1, 11 (25%) of 44 eyes lost > or = 2 lines of BSCVA after initial hyperopic LASIK compared to 14 (31.8%) of 44 eyes after retreatment. In group 2, 10 (24.4%) of 41 eyes lost > or = 2 lines of BSCVA after initial hyperopic LASIK compared to 12 (29.2%) of 41 eyes after retreatment. After hyperopic LASIK retreatment, 31 (70.5%) of 44 eyes in group 1 and 19 (46.4%) of 41 eyes in group 2 were within +/- 0.5 D of emmetropia. Safety was 0.9 in both groups and efficacy was 0.8 and 0.7 in groups 1 and 2, respectively. Complications included epithelial ingrowth of 1 to 3 mm (30%) and flap edge melting (2%). CONCLUSIONS: Hyperopic LASIK retreatment improved the refractive results of initial hyperopic LASIK surgery with 20% to 30% of eyes gaining > or = 1 lines of BSCVA. The loss of BSCVA was greater after primary hyperopic LASIK than after retreatment.

Adult↗

Hyperopic LASIK with Esiris/Schwind technology.

PURPOSE: To investigate the refractive and visual outcomes of hyperopic LASIK using Esiris/Schwind technology. METHODS: This retrospective non-comparative observational study included 106 eyes (65 patients) operated with the Esiris/Schwind laser for hyperopia. Eyes were divided into two groups: group 1, < or = +3.99 diopters (D) and group 2, > or = +4.0 D (up to +7.0 D). Visual outcome for distance and near uncorrected (UCVA) and best spectacle-corrected visual acuities (BSCVA) (decimal values), cycloplegic refraction, keratometry (K), pachymetry, and complications were evaluated. RESULTS: In group 1, mean UCVA was 0.4 +/- 0.1 preoperatively and 0.8 +/- 0.2 6 months postoperatively. Mean BSCVA was 0.9 +/- 0.1 preoperatively and 0.9 +/- 0.1 6 months postoperatively. Safety index was 1.1 and efficacy index was 0.97. Mean spherical equivalent refraction was +2.33 +/- 0.9 D preoperatively and +0.3 +/- 0.3 D 6 months postoperatively. Mean K reading was 43.7 +/- 1.1 D preoperatively and 45.0 +/- 1.6 D 6 months postoperatively. In group 2, mean UCVA was 0.3 +/- 0.1 preoperatively and 0.8 +/- 0.2 6 months postoperatively. Mean BSCVA was 0.9 +/- 0.1 preoperatively and 0.9 +/- 0.1 6 months postoperatively. Safety index was 0.98 and efficacy index was 0.92. Mean spherical equivalent refraction was +5.1 +/- 0.9 D preoperatively and +0.4 +/- 0.5 D 6 months postoperatively. Mean K reading was 43.1 +/- 1.6 D preoperatively and 46.0 +/- 1.4 D 6 months postoperatively. Forty-six (90.2%) of 51 eyes in group 1 and 47 (85.5%) of 55 eyes in group 2 were within +/- 0.5 D of emmetropia. At 6-month follow-up, 40 (78%) of 51 eyes in group 1 had UCVA of 20/20 compared to 41 (75%) of 51 eyes in group 2. One (2%) of 51 eyes in group 1 and 4 (7.3%) of 55 eyes in group 2 lost < or = 2 lines of BSCVA. No eye lost >2 lines of BSCVA. CONCLUSIONS: Hyperopic LASIK with Esiris/Schwind technology is effective and safe in the correction of hyperopia up to + 7.0 D. Although a slight statistical significance was found for low hyperopia, visual and refractive results obtained in high hyperopia were encouraging.

Adult↗

Wavefront analyzers induce instrument myopia.

PURPOSE: To assess the accuracy of three wavefront analyzers versus a validated binocular open-view autorefractor in determining refractive error in non-cycloplegic eyes. METHODS: Eighty eyes were examined using the SRW-5000 open-view infrared autorefractor and, in randomized sequence, three wavefront analyzers: 1) OPD-Scan (NIDEK, Gamagori, Japan), 2) WASCA (Zeiss/Meditec, Jena, Germany), and 3) Allegretto (WaveLight Laser Technologies AG, Erlangen, Germany). Subjects were healthy adults (19 men and 21 women; mean age: 20.8 +/- 2.5 years). Refractive errors ranged from +1.5 to -9.75 diopters (D) (mean: +1.83 +/- 2.74 D) with up to 1.75 D cylinder (mean: 0.58 +/- 0.53 D). Three readings were collected per instrument by one examiner without anticholinergic agents. Refraction values were decomposed into vector components for analysis, resulting in mean spherical equivalent refraction (M) and J0 and J45 being vectors of cylindrical power at 0 degrees and 45 degrees, respectively. RESULTS: Positive correlation was observed between wavefront analyzers and the SRW-5000 for spherical equivalent refraction (OPD-Scan, r=0.959, P<.001; WASCA, r=0.981, P<.001; Allegretto, r=0.942, P<.001). Mean differences and limits of agreement showed more negative spherical equivalent refraction with wavefront analyzers (OPD-Scan, 0.406 +/- 0.768 D [range: 0.235 to 0.580 D] [P<.001]; WASCA, 0.511 +/- 0.550 D [range: 0.390 to 0.634 D] [P<.001]; and Allegretto, 0.434 +/- 0.904 D [range: 0.233 to 0.635 D] [P<.001]). A second analysis eliminating outliers showed the same trend but lower differences: OPD-Scan (n=75), 0.24 +/- 0.41 D (range: 0.15 to 0.34 D) (P<.001); WASCA (n=78), 0.46 +/- 0.47 D (range: 0.36 to 0.57 D) (P<.001); and Allegretto (n=77), 0.30 +/- 0.62 D (range: 0.16 to 0.44 D) (P<.001). No statistically significant differences were noted for J0 and J45. CONCLUSIONS: Wavefront analyzer refraction resulted in 0.30 D more myopia compared to SRW-5000 refraction in eyes without cycloplegia. This is the result of the accommodation excess attributable to instrument myopia. For the relatively low degrees of astigmatism in this study (<2.0 D), good agreement was noted between wavefront analyzers and the SRW-5000.

Adult↗

Refractive errors among students of a postprimary institution in a rural community in south-eastern Nigeria.

OBJECTIVE: To determine the prevalence and types of refractive errors seen among students of Girls' Secondary School, Akegbe Ugwu in Nkanu West Local Government area of Enugu State, Nigeria. METHODS: A questionnaire documented the students' personal data, their chief complaints and past ocular history. This was followed by unaided visual acuity assessment then assessment with pinhole, anterior segment examination, fundoscopy, non-cycloplegic objective and subjective refraction in those found to have an unaided visual acuity of less than 6/9 in either eye and improved vision with pinhole. RESULTS: A total of 355 students aged 12 -21 years was tested. Out of these, 9 (2.53%) had uncorrected vision worse than 6/9 in either or both eyes. Uncorrected refractive error accounted for the reduced vision in 7 cases 5 of which were myopia. CONCLUSION: There is a prevalence of refractive error of 1.97 % among students of this rural girls' secondary school in South-Eastern Nigeria. The low prevalence of myopia (1.4%) found agrees with the report that, though the most common refractive cause of visual impairment globally, it is relatively rarer in Africans.

Adolescent↗

[Binocular vision following refractive surgery in hyperopic patients].

PURPOSE: To evaluate the changes in binocular vision and ocular motility in hyperopic patients undergoing refractive surgery. METHODS: Prospective study of 31 consecutive patients who underwent bilateral refractive surgery for hyperopia between May 1999 and February 2002. The examination included best-corrected visual acuity, cycloplegic refraction, ocular motility, fusion at distance, stereopsis and fusional amplitudes, before and at one month, 3 months, 6 months, one year after surgery and annually thereafter. RESULTS: After refractive surgery, there were changes in visual acuity, residual hyperopic refractive errors, and anisometropic changes that influenced the oculomotor status. The most frequent sensory modifications were suppression at distance, with much less change in stereopsis. From the point of view of ocular motility, we found a significant tendency to esotropia in strabismic patients (p=0.003). In non-strabismic patients, we also found sensorimotor modifications, but of less intensity and with fewer consequences than in strabismic patients. Sensorial and/or motor decompensation appeared in 25% of strabismic patients, and asthenopia symptoms developed in 28.7% in the same group. CONCLUSIONS: Slight binocular modifications with no symptomatic consequences were found in patients with normal binocular vision. However ocular motility was modified towards esotropia in strabismic patients, binocular decompensation appeared in 25%, and 28.7% of them suffered from asthenopia.

Adolescent↗

Naturally occurring vitreous chamber-based myopia in the Labrador retriever.

PURPOSE: To investigate whether myopia is present in a breed of domestic dog, the Labrador retriever, and how the ocular components are related to refractive error in this breed. METHODS: Cycloplegic refractive error was measured in 75 Labrador retrievers by retinoscopy. Corneal and crystalline lens radii of curvature were measured in the right eyes of 57 of these dogs using a video-based keratophakometer, with axial ocular dimensions measured using A-scan ultrasonography. RESULTS: Of the 75 dogs tested, 11 (14.7%) were myopic by at least -0.50 D in one eye, and 6 (8.0%) were myopic in both eyes (full range of refractive errors, +3.50 D to -5.00 D). Of the 57 dogs with ocular component measurements, seven (12.3%) were myopic by at least -0.50 D in the right eye. There was a significant negative correlation between refractive error and vitreous chamber depth (Spearman r = -0.42; P < 0.001). Myopic eyes had an elongated vitreous chamber depth (10.87+/-0.34 mm for myopic dogs, 10.02+/-0.40 mm for nonmyopic dogs; P < 0.0001, Kruskal-Wallis test). There was also a significant quadratic association between lens thickness and vitreous chamber depth (P < 0.005; R2 = 0. 11), indicating that thinner lenses occurred at both shorter and longer vitreous chamber depths. CONCLUSIONS: Myopia in the Labrador retriever is analogous to human myopia in that it is caused by an elongated vitreous chamber. Thinner crystalline lenses found at longer vitreous chamber depths may be analogous to lens thinning documented in human ocular development. The Labrador retriever warrants investigation as a potential model of myopia that is naturally occurring rather than experimentally induced.

Animals↗

Persistent hyperplastic primary vitreous with myopia: a case study.

BACKGROUND: Persistent hyperplastic primary vitreous (PHPV) is a congenital disorder that manifests a range of ocular anomalies, including leukocoria, microphthalmia, cataract, and a retrolental fibrovascular membrane. In general, the prognosis for visual acuity with PHPV has been poor. A recent report on six patients who have myopia associated with PHPV showed that these patients were not microphthalmic, did not manifest leukocoria, and showed a mean visual acuity at final followup of 20/160. CASE REPORT: The case of a 3-year-old boy with myopic PHPV of the left eye is presented. Full-time wear of the cycloplegic refraction, combined with patching of the non-amblyopic eye, resulted in an improvement in visual acuity. RESULTS: PHPV with myopia may constitute a distinct subtype of PHPV. Patients with myopic PHPV tend to seek treatment later than patients with anterior or posterior PHPV as a result of the lack of microphthalmia and leukocoria. These individuals do not show the long-term complications, such as secondary glaucoma and intraocular hemorrhages, associated with PHPV. CONCLUSION: The acuity improvement in this case of myopic PHPV suggests that a more conservative approach to its surgical management may be appropriate while pursuing refractive correction and amblyopia therapy to attain the best acuity possible.

Child, Preschool↗

A study of aniseikonia and Knapp's law using a projection space eikonometer.

PURPOSE: Knapp's Law, which states that anisometropias due to varying abnormal axial lengths between eyes would not result in inequality in relative retinal image size, provided the correcting spectacle lens was placed at the far point of the eye, has been shown to fall short in clinical practice in several studies using "direct comparison eikonometry". To test these findings using space eikonometry and to further elucidate this Law's clinical applicability, the following study was conducted. METHODS: Thirteen patients with suspected axial anisometropia of at least 4 Diopters were identified, selected and examined. Cycloplegic refraction, A-scan ultrasonic ocular biometry and Essilor Projection Space Eikonometry were performed. RESULTS: Ten of the thirteen patients had their anisometropia due primarily to ocular axial length differences. Of these ten, seven (70%) had detectable levels of aniseikonia and 3 (30%) demonstrated no aniseikonia. The other three patients whose aniso-metropia was due to combined axial and refractive components, all had aniseikonia. CONCLUSION: As a geometric optics theory, Knapp's Law stands on its own merits. However, in clinical practice, reduction in retinal element density in high myopia limits its applicability. Such patients often do have significant aniseikonia which can produce ocular referable complaints and/or interfere with binocular vision.

Adolescent↗

Posner-Schlossman syndrome: a case report.

BACKGROUND: Glaucomatocyclitic Crisis (AKA Posner-Schlossman syndrome) is a syndrome that affects patients between the ages of 20 and 50 years. It is characterized by a mild recurrent anterior uveitis associated with an out-of-proportion intraocular pressure spike in the same eye. The cause is unclear, but many theories exist. Some researchers have tried to connect it with primary open-angle glaucoma. CASE REPORT: A review of the record of a 41-year-old Hispanic woman with Posner-Schlossman syndrome is discussed. She sought treatment on multiple occasions with symptoms of mild pain, photophobia, and a blurry left eye. Examination revealed mild anterior chamber reaction and an intraocular pressure (IOP) spike in the same eye. She was treated with topical anti-inflammatory and pressure-lowering agents. Each individual flare-up was treated successfully, but the patient began to show equivocal signs of primary open-angle glaucoma (PDAG). She is currently treated prophylactically for POAG with a beta-blocker. No etiologic factor was identified in this patient. The differential diagnosis is straight-forward and the treatment is general uveitic therapy--minus cycloplegics--combined with an IOP-lowering drop. CONCLUSION: This is an interesting and relatively rare uveitic condition. The list of differential diagnoses is long, as is the theorized etiologies; however, clinically the condition is relatively quickly identifiable by the presence (and absence) of signs and symptoms.

Adrenergic beta-Antagonists↗

Childhood blindness and visual loss: an assessment at two institutions including a "new" cause.

PURPOSE: This study was initiated to investigate the causes of childhood blindness and visual impairment in the United States. We also sought a particular etiology--congenital lymphocytic choriomeningitis virus (LCMV)--which has been considered exceedingly rare, in a fixed target population of children, the severely mentally retarded. METHODS: We undertook a library-based study of the world literature to shed light on the causes of childhood blindness internationally and to put our data in context. We prospectively examined all consented children (159) at 2 institutions in the United States to determine their ocular status and the etiology of any visual loss present. One of the institutions is a school for the visually impaired (hereafter referred to as Location V), in which most of the students have normal mentation. The other is a home for severely mentally retarded, nonambulatory children (hereafter referred to as Location M). This institution was selected specifically to provide a sample of visual loss associated with severe retardation because the handful of cases of LCMV in the literature have been associated with severe central nervous system insults. Histories were obtained from records on site, and all children received a complete cyclopleged ophthalmic examination at their institution performed by the author. Patients at Location M with chorioretinal scars consistent with intrauterine infection (a possible sign of LCMV) had separate consents for blood drawing. Sera was obtained and sent for standard TORCHS titers, toxoplasmosis titers (Jack S. Remington, MD, Palo Alto, Calif), and ELISA testing for LCMV (Centers for Disease Control and Prevention, Atlanta, Ga). RESULTS: The diagnoses at Location V were varied and included retinopathy of prematurity (19.4%), optic atrophy (19.4%), retinitis pigmentosa (14.5%), optic nerve hypoplasia (12.9%), cataracts (8.1%), foveal hypoplasia (8.1%), persistent hyperplastic primary vitreous (4.8%), and microphthalmos (3.2%). The most common diagnosis at Location M was bilateral optic atrophy, which was found in 65% of the patients examined who had visual loss. Of these, the insults were most often congenital (42.6%), with birth trauma, prematurity, and genetics each responsible for about 15% of the optic atrophy. The second most common diagnosis was cortical visual impairment (24%), followed by chorioretinal scars (5%), which are strongly suggestive of intrauterine infection. Of 95 patients examined at Location M, 4 had chorioretinal scars. Two of these had dramatically elevated titers for LCMV, as did one of their mothers. One of the other 2 children died before serum could be drawn, and the fourth had negative titers for both TORCHS and LCMV. CONCLUSIONS: At both locations studied, visual loss was most often due to congenital insults, whether genetic or simply prenatal. The visual loss at Location V was twice as likely as that at Location M to be caused by a genetic disorder. The genetic disorders at Location V were more often isolated eye diseases, while those among the severely retarded at Location M were more generalized genetic disorders. Our study identified optic atrophy as a common diagnosis among the severely mentally retarded with vision loss, a finding that is supported by previous studies in other countries. In our population of severely retarded children, the target etiology of lymphocytic choriomeningitis virus was responsible for half the visual loss secondary to chorioretinitis from intrauterine infection. This is more common than would be predicted by the few cases previously described in the literature, and strongly suggests that LCMV may be a more common cause of visual loss than previously appreciated. We believe that serology for LCMV should be part of the workup for congenital chorioretinitis, especially if the TORCHS titers are negative, and that perhaps the mnemonic should be revised to "TORCHS + L." Childhood blindness and visual impairment are tragic and co

Adolescent↗

Studies of intrastromal corneal ring segments for the correction of low to moderate myopic refractive errors.

PURPOSE: Intrastromal corneal ring segments (ICRS) were investigated for safety and reliability in the correction of low to moderate myopic refractive errors. METHODS: Initially, 74 patients with spherical equivalent refractive errors between -1.00 and -4.25 diopters (D) received the ICRS in 1 eye. After 6 months, 51 of these patients received the ICRS in the contralateral eye. The total number of eyes investigated was 125. The outcome measures were uncorrected and best-corrected visual acuity, predictability and stability of the refraction, refractive astigmatism, contrast sensitivity, and endothelial cell morphology. RESULTS: The 89 eyes with 12-month follow-up showed significant improvement with uncorrected visual acuities of 20/16 or better in 37%, 20/20 or better in 62%, and 20/40 or better in 97%. Cycloplegic refraction spherical equivalents showed that 68% of the eyes were within +/- 0.50 D and 90% within +/- 1.00 D of the intended correction. Refractive stability was present by 3 months after the surgery. Only 1 patients had a loss greater than 2 lines or 10 letters of best spectacle-corrected visual acuity, but the patient's acuity was 20/20. Refractive cylinder, contrast sensitivity, and endothelial cell morphology were not adversely affected. The ICRS was removed from the eyes of 6 patients. Three removals were prompted by glare and double images occurring at night; 3 were for nonmedical reasons. All patients returned to within +/- 1.00 D of their preoperative refractive spherical equivalent, and no patients lost more than 1 line of best corrected visual acuity by 3 months after ICRS removal. CONCLUSION: The ICRS safely and reliably corrects myopic refractive errors between -1.00 and -4.50 D.

Adult↗

Peripheral refraction and ocular shape in children.

PURPOSE: To evaluate the relation between ocular shape and refractive error in children. METHODS: Ocular shape was assessed by measuring relative peripheral refractive error (the difference between the spherical equivalent cycloplegic autorefraction 30 degrees in the nasal visual field and in primary gaze) for the right eye of 822 children aged 5 to 14 years participating in the Orinda Longitudinal Study of Myopia in 1995. Axial ocular dimensions were measured by A-scan ultrasonography, crystalline lens radii of curvature by videophakometry, and corneal power by videokeratography. RESULTS: Myopic children had greater relative hyperopia in the periphery (+0.80 +/- 1.29 D), indicating a prolate ocular shape (longer axial length than equatorial diameter), compared with relative peripheral myopia and an oblate shape (broader equatorial diameter than axial length) for emmetropes (-0.41 +/- 0.75 D) and hyperopes (-1.09 +/- 1.02 D). Relative peripheral hyperopia was associated with myopic ocular component characteristics: deeper anterior and vitreous chambers, flatter crystalline lenses that were smaller in volume, and steeper corneas. Lens thickness had a more complex association. Relative peripheral hyperopia was associated with thinner lenses between refractive error groups but changed in sign to become associated with thicker lenses when analyzed within each refractive error group. Receiver operator characteristics analysis of the ocular components indicated that vitreous chamber depth was the most important ocular component for characterizing the myopic eye, but that peripheral refraction made a significant independent contribution. CONCLUSIONS: The eyes of myopic children were both elongated and distorted into a prolate shape. Thinner crystalline lenses were associated with more hyperopic relative peripheral refractions across refractive error groups, but failure of the lens to thin may account for the association between thicker lenses and more hyperopic relative peripheral refractions within a given refractive group. Increased ciliary-choroidal tension is proposed as a potential cause of ocular distortion in myopic eyes.

Adolescent↗