Plastic balloons for high altitude research.
Explore the source record for details and available documents.
SEARCH · Search PubMed
Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
We have flown two new charged particle detectors in five recent Shuttle flights. In this paper we report on the dose rate, equivalent dose rate, and radiation quality factor for trapped protons and cosmic radiation separately. A comparison of the integral linear energy transfer (LET) spectra with recent transport code calculations show significant disagreement. Using the calculated dose rate from the omni-directional AP8MAX model with IGRF reference magnetic field epoch 1970, and observed dose rate as a function of (averaged over all geographic latitude) and longitude, we have determined the westward drift of the South Atlantic anomaly. We have also studied the east-west effect, and observed a 'second' radiation belt. A comparison of the galactic cosmic radiation lineal energy transfer spectra with model calculations shows disagreement comparable to those of the trapped protons.
Two new charged particle detectors have been flown in five recent Shuttle flights. The tissue-equivalent proportional counter measures the lineal energy spectrum of space radiation in the 0.26-300 keV micrometer-1 range. The charged particle spectrometer is a double dE/dx x E and dE/dx x Chrenekov detector system which provides a measurement of the differential energy spectrum of protons from 13 to 350 MeV and dose rate in silicon. In this paper the dose rate, equivalent dose rate, and radiation, quality factor for trapped protons and cosmic radiation are reported on separately. A comparison of the integral LET spectra with recent transport code calculations shows significant disagreement. Using the calculated dose rate from the omnidirectional AP8MAX model with IGRF reference magnetic field epoch 1970, and observed dose rate as a function of geographic latitude and longitude, the westward drift of the south Atlantic anomaly has been determined. The east-west effect has also been studied and a 'second' radiation belt observed. A comparison of the galactic cosmic radiation (GCR) lineal energy transfer spectra with model calculations shows disagreement comparable with those of the trapped protons.
The number of human beings likely to spend time in space will increase as time goes on. While exposures vary according to missions, orbits, shielding, etc., an average space radiation fluence (ignoring solar flares, radiation belts and anomalous regions in space) in locations close to earth is about 10 rad/year with a quality factor of about 5.5. The potential effects of exposure to these fluences include both non-stochastic effects and stochastic effects (cancer and genetic damage). Non-stochastic effects, damage to the lens of the eye, bone marrow or gonads, can be avoided by keeping radiation limits below threshold values. Stochastic effects imply risk at all levels. The magnitude of these risks has been discussed in a number of reports by the UNSCEAR Committee and the BEIR Committee in the USA during 1970-1980. The uncertainties associated with these risks and information which has become available since the last BEIR report is discussed. In considering reasonable limits for exposure in space, acceptable levels for stochastic risks must be based on appropriate comparisons. In view of the limited term of duty of most space workers, a lifetime limit may be appropriate. This lifetime limit might be comparable in terms of risks with limits for radiation workers on the ground but received at a higher annual rate for a shorter time. These and other approaches are expected to be considered by an NCRP Committee currently examining the problem of space radiation hazards.
A simplified system for measuring time-resolved photoluminescence (PL) induced by UV laser pulses (lambda = 337 nm) is designed by a combination of a commercial PL reader and a digital oscilloscope. Using this system, PL emissions after pulsed UV excitation from a chip of sapphire (Al2O3) are successfully measured with intervals of 10 ns. It is thus expected that this system will be conveniently used for searching new PL materials that would be more suitable for space radiation dosimetry.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Measurements during solar particle events with dosemeters flying permanently on-board Concorde are used to develop a semi-empirical model, called SiGLE. The model is intended to calculate, for a given flight plan, the dose equivalent received during a solar particle event observed with ground-based neutron monitors. It is successfully in operation in the SIEVERT computerised system intended to improve monitoring of radiation dose received by aircrews, in application to a European Directive. The semi-empirical model is applied to evaluate, for most exposed routes, the radiation doses corresponding to the GLEs observed since 1942 with ion chambers or neutron monitors. The results for the largest GLEs observed in the past are discussed in terms of radiation risk, and guidelines are suggested concerning possible alerts to the aeroplanes in case of events of exceptional magnitude.