Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Anthropometry”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39Linked to original sources

Anthropometry and body composition in ethnic Japanese and Caucasian adolescent girls: considerations on ethnicity and menarche.

OBJECTIVE: This study aimed to compare the various anthropometric and body composition parameters based on the ethnicity and the absence or presence of menarche. DESIGN: A cross-sectional study with incomplete sampling, using the subject as the evaluation unit. SUBJECTS: The final sample of 550 subjects was composed of 122 Japanese and 179 Caucasian premenarcheal adolescents, and 72 Japanese and 177 Caucasian postmenarcheal adolescents. METHODS: The variables of body composition were measured through the following methods: bioelectrical impedance analysis, near-infrared interactance (NIR), Slaughter cutaneous skinfold equations and body mass index. Weight, height and sitting height were also evaluated. RESULTS: The Japanese pre- and postmenarcheal girls presented lower weight and height values when compared with the Caucasian girls. In general, the Japanese premenarcheal girls presented less fat and fat-free mass than the premenarcheal Caucasian girls. This fact was demonstrated through NIR results. Conversely, the Japanese postmenarcheal adolescents accumulated more fat than their Caucasian counterparts. However, significant differences were solely encountered in the values of cutaneous skinfold percent body fat. With regard to menarche, it was verified that, regardless of ethnicity, all the anthropometric and body composition variables reached higher values among postmenarcheal adolescents when compared with premenarcheal adolescents. CONCLUSION: Different results of weight and height between the ethnic groups may bring back the discussion concerning separate growth curves for different ethnic groups. The results of the body composition analysis indicated high adiposity levels among postmenarcheal adolescents.

Adipose Tissue↗

Anthropometry, bioelectrical impedance and dual-energy X-ray absorptiometry in the assessment of body composition in elderly Finnish women.

In this study, the bioelectrical impedance analysis (BIA), skinfold thickness measurement (STM) and dual-energy X-ray absorptiometry (DXA), as a reference method, were compared with each other in the assessment of body composition in elderly (62-72-year-old) Finnish women (n=93). BIA had better agreement with DXA in the assessment of fat free mass (FFM, R2=0.70, Sres=2.1) and fat mass (FM, R2=0.93, Sres=2.3) than the STM (FFM, R2=0.62, Sres=2.4; FM, R2=0.89,Sres=2.8). There was quite a large variation in the estimates when different BIA prediction equations were used. The equation developed in this study, FFM (kg)=-128.06 + 1.85 x BMI-0.63 x weight + 1.07 x height - 0.03 x resistance +10.0 x waist-hip ratio, yielded a small and unbiased error (0.5 +/- 1.6 kg), with a small residual standard deviation (R2=0.83, Sres=1.6). However, error associated with the estimate of FM was positively related to the degree of FM. BIA(Heitmann) equation yielded unbiased estimates of both FFM and FM (FFM, R2=0.77, Sres=1.8; FM, R2=0.95, Sres=1.9). Both the STM and BIA (manufacturer's equation) resulted in error which was statistically significant and positively correlated with FFM and FM. These results indicate that BIA prediction equations, chosen with care, can improve the performance of equations based upon anthropometric measurements alone in the assessment of body composition in elderly women.

Absorptiometry, Photon↗

Auricular anthropometry of Hong Kong Chinese babies.

OBJECTIVES: To provide a database of the auricular measurements of Chinese infants born in Hong Kong. DESIGN: Prospective cross-sectional study. SETTING AND SAMPLE POPULATION: A total of 2384 healthy singleton, born consecutively at the Prince of Wales Hospital and the Union Hospital from October 1998 to September 2000, were included in the study. The range of gestation was 33-42 weeks. MEASUREMENTS AND RESULTS: Measurements included ear width (EW), ear length (EL) and ear position (EP). The data show generally higher values for males in the parameters measured. When compared with previously published data for Caucasian and Jordanian term babies, Chinese babies have shorter EL. The ears were within normal position in nearly all our infants. CONCLUSION: The human ear appears to grow in a remarkably constant fashion. This study establishes the first set of gestational age-specific standard of the ear parameters for Chinese new-borns, potentially enabling early syndromal diagnosis. There are significant inter-racial differences in these ear parameters.

Asian People↗

[Influence of sports on development of 10 and 11-year-old boys. I. Body composition, anthropometry and creatinine excretion].

We compared body composition (measured by total-body water determination), skinfolds, body circumferences and diameters and the muscle arm area of 10 to 11-year-old boys (n = 21) at the beginning and the end of a 9-months training period (track-and field athletics) with data obtained in 12 control subjects of corresponding ages. Urinary creatinine excretion was measured as a parameter of muscle mass at the end of the training period. Boys engaged in training gained (mean: + 2,6 kg) significantly less (p less than 0,05) weight than controls (mean: + 3,9 kg). Fat-free mass (FFM) as percentage of weight significantly increased in boys engaged in training (mean: + 1,8%; p less than 0,005) at the expense of fat whereas in controls (mean: + 0,6%; p: n.s.) there was no significant change. Decreasing skinfold thickness in boys engaged in training indicated reduction of subcutaneous fat. In controls, subcutaneous fat increased at the trunk and decreased at the periphery. Regression analysis indicated that changes of triceps skinfold thickness did not reflect changes in body fat content (r = 0.30; p: n.s.). A significant relation was established between changes of the subcapular skinfold thickness (r = 0,46; p less than 0,005) and of the sum of 5 skinfolds on the one hand (r = 0,51; p less than 0,005) and the changes of body fat content on the other hand. High standard deviations from the regression lines, however, indicated that accurate prediction of changes in body fat content was not possible in an individual subject.(ABSTRACT TRUNCATED AT 250 WORDS)

Arm↗

Body composition of lactating women determined by anthropometry and deuterium dilution.

1. Body fat, fat-free mass and total body water of ten lactating women were estimated from deuterium-dilution spaces and from skinfold thickness measurements. Deuterium-dilution spaces were calculated from the 6 h (equilibration) and zero-time (extrapolation) deuterium enrichments in saliva, urine, human milk and breath water vapour samples. 2. The deuterium spaces obtained by equilibration were statistically larger than those obtained by extrapolation. Isotope dilution spaces derived from deuterium enrichments in saliva, breath water vapour and human milk did not differ with the exception of the 6 h equilibration value of milk, which was greater than that estimated from saliva. Deuterium-dilution spaces estimated from urine were consistently smaller than those derived from the other biological fluids. 3. No significant differences in body fat, fat-free mass and total body water were observed between anthropometric measurements and deuterium-dilution methods, except for extrapolated values derived from deuterium enrichments in urine.

Adult↗

Comparison of body composition assessments by bioelectrical impedance and by anthropometry in premenopausal Chinese women.

Fat-free mass (FFM) was estimated in forty-seven premenopausal Chinese women, aged 18-43 years, from anthropometric data (skinfolds, body mass index (weight/height2; BMI)) or bioelectrical impedance, using several prediction formulas for body composition from the literature, and values compared with the mean of these three individual methods used as a frame of reference. In thirty-six women these values could be compared with FFM calculated from total body water (TBW) determined by D2O dilution. The prediction formulas used were developed from studies on Caucasian adults and their validity will have to be shown in populations with different ethnic backgrounds. The mean difference between FFM predicted from BMI and the frame of reference was 0.1 kg (95% confidence interval (CI) -0.1, 0.4), from bioelectrical impedance it was 0.5 kg (95% CI 0.3, 0.7), and from skinfolds it was -0.6 kg (95% CI -0.9, -0.4). The mean difference between FFM calculated from TBW and the frame of reference was higher (2.2 kg, 95% CI 1.2, 3.3). The results of the present study indicate that the three methods may be valid for predicting body composition in adult Chinese females, but further research is needed on development and cross-validation of prediction equations for body composition for Chinese.

Adolescent↗

Anthropometry at the time of diagnosis in Danish children with inflammatory bowel disease.

UNLABELLED: All patients below 15 y of age living in the eastern part of Denmark with a diagnosis of inflammatory bowel disease (IBD) during the period 1998-2000 were identified (n=94) and anthropometrical data at the time of diagnosis were evaluated. CONCLUSION: The height-for-age and the BMI-for-age, as evaluated by z-scores, of children with ulcerative colitis (UC) did not differ from those of normal Danish children, but Crohn's disease (CD) children had significantly lower height and BMI values, both when compared to normal children and children with UC. In contrast to UC, CD is frequently complicated by malnutrition and growth retardation at the time of diagnosis.

Adolescent↗

Body composition in adults with cerebral palsy by dual-energy X-ray absorptiometry, bioelectrical impedance analysis, and skinfold anthropometry compared with the 18O isotope-dilution technique.

The aim of this study was to determine in adults with cerebral palsy the accuracy and practicality of standard methods used to estimate body composition. The sample consisted of 20 adults (13 men and 7 women) aged 20-55 y with various degrees of cerebral palsy. Percentage body fat was estimated from skinfold thickness, bioelectrical impedance analysis (BIA), and dual-energy X-ray absorptiometry (DXA), and compared with the reference measure of percentage body fat from total body water by 18O dilution. Values derived from use of BIA and skinfold thickness, estimated by using the Jackson-Pollock equation, were significantly different from those derived with use of 18O dilution (P < 0.001 and P < 0.001, respectively). There was no significant difference between percentage body fat measured with DXA and that measured with 18O. There was favorable agreement between DXA and 18O (mean difference: 0.06 +/- 9.6%), but not between skinfold thickness (mean difference: 6.33 +/- 12.3%) or BIA (mean difference: -6.55 +/- 13.6%) and 18O. Although DXA was the best measure for predicting percentage body fat in the sample, its high cost prohibits its use as a practical method. The best-fitting regression equation specific for this sample by using anthropometric measures to predict percentage body fat was as follows: 8.76 - (7.34 x sex) + (0.32 x weight) + (0.38 x biceps skinfold) (R2 = 0.84, P < 0.001, SEE = 4.85). This equation needs to be cross-validated in an independent sample of adults with cerebral palsy.

Absorptiometry, Photon↗

Soft tissue facial anthropometry in Down syndrome subjects.

The three-dimensional coordinates of 50 selected soft tissue facial landmarks were digitized on 28 white Italian subjects with Down syndrome (17 male and 11 female subjects aged 12 to 45 years) and 429 healthy controls of comparable ages by an electromechanical instrument. From the landmarks, 16 facial dimensions were calculated. Data were compared with those collected in healthy individuals by computing z-scores. Overall, most variables were smaller in subjects with Down syndrome than in their normal controls selected for sex, age, and ethnicity (negative z-scores), even if not all of them reached statistical significance. Independently of sex, subjects with Down syndrome had faces that were significantly (P <0.05, paired Student t test) narrower (skull base and mandible), less deep (upper, middle, and lower face), and shorter (face and nose height) than the faces of normal subjects. Additionally, ear width and length were significantly reduced on both sides of the face. Only facial height was significantly different between sexes (P = 0.023, unpaired Student t test), with a female z-score that was more than two times the relevant male value. The present investigation represents the first detailed quantitative analysis of the facial soft tissue characteristics of Italian white subjects with Down syndrome.

Adolescent↗

Three-dimensional facial anthropometry using a laser surface scanner: validation of the technique.

Three-dimensional measurement and characterization of facial surface anatomy are fundamental to the objective analysis of facial deformity. However, existing clinical tools are inadequate. Recent innovations in laser scanning technology provide a potentially useful technique for accurate three-dimensional documentation of the face. The purpose of this study is to evaluate the reliability of interactive anthropometric landmark localization based on digitized three-dimensional facial images and to identify sources of error associated with the technique. Three-dimensional surface data were acquired using a commercially available laser scanning device (Cyberware 3030RGB digitizer), and all subsequent anthropometric analyses were performed interactively on the computer monitor. Four experimental conditions were studied, with 10 observations for each condition. A stable anthropomorphic model with prelabeled anatomic landmarks was scanned repeatedly under varying conditions of head inclination and position within the scanning gantry to determine the effect of these variables on the reliability of the technique. The scanning protocol was then repeated with the labels removed to evaluate the reliability of interactive localization of anthropometric landmarks on a digitized three-dimensional image. Optimal results were obtained with the head positioned in the center of the scanning gantry and with the Frankfort plane elevated 10 degrees from the horizontal. Under these circumstances, all 22 labeled landmarks were visualized and the variance in landmark localization was less than 0.6 mm in the x (horizontal), y (vertical), and z (depth) dimensions. Varying head position or inclination caused significant degradation of the digitized image. The variance of interactive landmark localization was analyzed in three dimensions. The reliability and the spatial orientation of variability were determined for each anthropometric point. These findings have direct implications for the clinical adaptation of this diagnostic tool for quantitative evaluation of facial surface anatomy.

Cephalometry↗

Ghrelin in preterm and term newborns: relation to anthropometry, leptin and insulin.

AIMS: This study aimed to investigate (i) the plasma ghrelin concentration at birth, (ii) the relationship of ghrelin with metabolic hormones, including leptin and insulin, and (iii) its association with anthropometric parameters, in appropriately grown preterm (23-36 weeks gestation) and term (37-42 weeks gestation) newborns. PATIENTS AND METHODS: Blood samples for hormonal assay were obtained from preterm (n = 81) and term newborns (n = 40) within the first 2 h of life and before milk feeding or energy intake. The relationship between plasma ghrelin and other metabolic hormones or anthropometric parameters was evaluated. RESULTS: Plasma ghrelin was detectable in all studied infants and the concentrations did not differ significantly between term and preterm infants [median (interquartile range): 1.21 (0.86-1.48) nmol/l vs. 1.04 (0.71-1.51) nmol/l, P = 0.52, respectively]. There was no overall significant correlation between plasma ghrelin and gestational age, anthropometric parameters and leptin or insulin. However, when term and preterm infants were analysed independently, plasma ghrelin was inversely correlated with birth weight (r = -0.31, P = 0.05) and body length (r = -0.33, P = 0.04) in the term infant group. CONCLUSIONS: Our findings suggested that plasma ghrelin concentrations were relatively constant at birth, between 23 and 42 weeks gestation, and ghrelin secretion did not appear to undergo gestational age-related variations. An inverse relationship between plasma ghrelin and anthropometric indices in term infants raised the possibility that ghrelin might adopt its physiological role in regulating growth and metabolism at a late stage of gestation (> or = 37 weeks gestation). This phenomenon could be beneficial to term newborns by stimulating their appetite and maintaining an adequate blood sugar level at the most critical period when nutrients from mothers are abruptly terminated after birth.

Birth Weight↗

Long-distance running alters bone anthropometry, elemental composition and mineral density of young dogs.

Ten young beagle dogs were run on a treadmill for 1 year, the last 15 weeks 40 km/day. Thereafter bone anthropometric variables, elemental composition, mineral density (BMD) and serum markers of bone metabolism were analyzed and compared with matched-paired control dogs. More osteophytes developed, weight-bearing bones grew larger and BMD of axial skeleton was reduced in the trained group. Zinc and sodium accumulated in bones of the runners. Zinc correlated negatively with BMD. Serum osteocalcin and C-terminal propeptide of type I procollagen did not correlate with the observed differences in BMD. This experiment implies that intensive endurance training in adolescence may reduce the peak bone mass and alter the structural properties of bone.

Animals↗

Potassium per kilogram fat-free mass and total body potassium: predictions from sex, age, and anthropometry.

Total body potassium (TBK) is located mainly intracellularly and constitutes an index of fat-free mass (FFM). The aim was to examine whether TBK and the TBK-to-FFM ratio (TBK/FFM) can be estimated from sex, age, weight, and height. A primary study group (164 males, 205 females) and a validation group (161 and 206), aged 37-61 yr, were randomly selected from the general population. TBK was determined by whole body counting, and FFM was obtained by dual-energy X-ray absorptiometry (DEXA; FFM(DEXA)). The primary study group was used to construct sex-specific equations predicting TBK and TBK/FFM from age, weight, and height. The equations were used to estimate TBK and TBK/FFM in the validation group. The estimates were compared with measured values. TBK in different age ranges was predicted, with errors ranging from 5.0 to 6.8%; errors for TBK/FFM ranged from 2.7 to 4.8%, respectively. By adding FFM(DEXA) as a fourth predictor, the error of the TBK prediction decreased by approximately two percentage units. In conclusion, TBK and TBK/FFM can be meaningfully estimated from sex, age, weight, and height.

Absorptiometry, Photon↗