Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ATMOSPHERIC PRESSURE”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39Linked to original sources

Investigation of the metabolism of ebrotidine in human urine by liquid chromatography-atmospheric pressure chemical ionization mass spectrometry.

Ebrotidine is a new H2-receptor antagonist that, in addition to its antisecretory activity, exhibits a remarkable ability for gastric mucosal protection and acts as a potent inhibitor of protease and lipase enzymes elaborated by Helicobacter pylori. To study the metabolism of ebrotidine in human urine, HPLC/MS with an atmospheric pressure chemical ionization (APCI) interface and simultaneous UV detection was conducted. HPLC/MS separation of the reference compounds was performed, and positive and negative APCI mass spectra were obtained. Compounds of low molecular weight (M(r) < 300) showed predominantly the quasi-molecular ion. Intermediate size compounds (300 < M(r) < 400) gave a different type of spectra, depending on the ion mode: the positive mass spectra showed only the protonated molecular ion, whereas in the negative mass spectra many fragments appeared in addition to the deprotonated molecular ion. For molecules with a higher molecular weight (M(r) > 400), high fragmentation was observed. LC/MS with an APCI interface in positive and negative modes allowed the identification of ebrotidine, 4-bromobenzenesulfonamide, and four S-oxidized metabolites in human urine.

Benzenesulfonates↗

Molecular species of sphingomyelin: determination by high-performance liquid chromatography/mass spectrometry with electrospray and high-performance liquid chromatography/tandem mass spectrometry with atmospheric pressure chemical ionization.

In a sphingomyelin-enriched sample of polar lipids from bovine milk, molecular species of intact sphingomyelin were separated by normal-phase high-performance liquid chromatography and detected by mass spectrometry (MS) for structural information. First, by using electrospray with positive ionization (ESI), protonated molecules ([M + H]+) were detected. Second, in atmospheric pressure chemical ionisation (APCI+), in-source fragmentation of sphingomyelin ions led to the formation of ceramide ions. With the ceramide ions as precursors, ions representative of both the long-chain base (LCB) parts and the fatty acid (FA) parts were detected in APCI-MS/MS via collision-induced decomposition (CID). Using this procedure, it was possible to determine the sphingomyelin molecular masses using ESI+ and then their respective LCB-FA combinations(s) using APCI+(-)MS/MS. At least 36 protonated molecules of intact sphingomyelin were detected in the bovine milk sample. The combinations found covered a range of molecular masses from 673 to 815 Da. The 12 most common protonated molecules (constituting approximately 90% of the total ion current in ESI) were composed of at least 25 different LCB-FA combinations. Saturated and unsaturated LCBs and FAs were detected in addition to hydroxy fatty acids. The most common LCBs were 16:1, 17:1, 18:1 and 19:1, whereas the most common FAs were 16:0, 22:0, 23:0 and 24:0. LCB-FA combinations of sphingomyelin from bovine brian, bovine erythrocytes and chicken egg yolk are also presented.

Animals↗

Quantitative analysis of mutagenic heterocyclic aromatic amines in cooked meat using liquid chromatography-atmospheric pressure chemical ionisation tandem mass spectrometry.

Five mutagenic heterocyclic aromatic amines (HAAs) were quantified from meat extracts, and grilled and pan fried bacon samples using stable isotopically labeled internal standards. These compounds were isolated from the matrices by a tandem solid-phase extraction procedure, followed by separation on reversed-phase liquid chromatography (HPLC) and quantified by atmospheric pressure chemical ionization tandem mass spectrometry (APCIMS-MS). Tandem mass spectrometry (MS-MS) acquisition was done in selected reaction monitoring (SRM) mode to provide a high degree of sensitivity and selectivity for accurate quantification of HAAs. The detection and quantification limits of these HAAs approached 0.015 and 0.045 microg/kg (part-per-billion), respectively, with only 4 g of meat. The HAA levels ranged widely from 0.045 to 45.500 microg/kg, and 2-amino-3,8-dimethylimidazo[4,5-f]quinoxaline (MeIQx) was the predominant HAA found in these samples. The amount of HAAs formed was highly dependent upon the type of meat and method of preparation. An intralaboratory comparison of the extraction procedure showed that estimates of these HAAs obtained by three different individuals at HAA levels below 2 microg/kg were within 5% with coefficients of variation below 19%, indicating the robustness of the analytical method. Moreover, because all of these HAAs from this class of molecules undergo facile cleavage at the N-methylimidazole moiety under collision-induced dissociation (CID) conditions, MS-MS analysis in the constant neutral loss mode of [M+H]+-15 enabled the identification of two other HAAs, 2-amino-3-methylimidazo[4,5-f]quinoxaline (IQx) and 2-amino-1,7,9-trimethylimidazo[4,5-g]quinoxaline (7,9-DiMeIgQx), which have rarely been reported in cooked meats.

Amines↗

Measurement and stability of FTY720 in human whole blood by high-performance liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry.

We report here a validated method for the quantification of a new immunosuppressant drug FTY720, using HPLC-tandem mass spectrometry. Whole blood samples (500 microl) were subjected to liquid-liquid extraction, in the presence of an internal standard (Y-32919). Mass spectrometric detection was by selected reaction monitoring with an atmospheric pressure chemical ionization source in positive ionization mode (FTY720: m/z 308.3-->255.3). The assay was linear from 0.2 to 25 microg/l (r(2)>0.997, n=5). The inter- and intra-day analytical recovery and imprecision for quality control samples (0.5, 7 and 15 microg/l) were 95.8-103.2 and <5.5%, respectively. At the lower limit of quantification (0.2 microg/l) the inter- and intra-day analytical recovery was 99.0-102.8% with imprecision of <7.6% (n=5). The assay had a mean relative recovery of 100.5+/-5.8% (n=15). Extracted samples were stable for 16 h. FTY720 quality control samples were stable at room temperature for 16 h, at 4 degrees C for at least 8 days and when taken through at least three freeze-thaw cycles. In conclusion, the method described displays analytical performance characteristics that are suitable for pharmacokinetic studies in humans.

Chromatography, High Pressure Liquid↗

Etodolac in equine urine and serum: determination by high-performance liquid chromatography with ultraviolet detection, confirmation, and metabolite identification by atmospheric pressure ionization mass spectrometry.

A high-performance liquid chromatographic method was used for the detection of etodolac in equine serum and urine. The method consisted of a one-step liquid-liquid extraction, separation on a reversed-phase (RP-18) column and detection using an ultraviolet detector. Additional confirmation methods included a HPLC coupled with an atmospheric pressure chemical ionization mass spectrometer (APCI-MS). Free (unbound) etodolac and its conjugates were present in the samples. Concentrations of the drug in the serum and urine samples collected from four standardbred mares after a single oral administration of Ultradol were determined. Maximum etodolac concentrations of 712, 716, 568, and 767 microg/mL in urine and 4.1, 3.6, 3.1, and 2.2 microg/mL in serum were observed. The peak concentrations of the drug were detected 2-10 h (urine) and 40 min-6 h (serum) after administration to four horses. The maximum detection time was 79 h in urine and 48 h in serum after the drug administration. The drug-elimination profiles for both urine and serum are presented and discussed. Method ruggedness and precision and stability studies of etodolac in serum and urine are presented. Three major metabolites were detected in the urine by liquid chromatography-APCI-MS. All three metabolites were identified as monohydroxylated etodolac.

Animals↗

Determination of nicarbazin in eggs by liquid chromatography-atmospheric pressure chemical ionization mass spectrometry.

A method was developed to determine in eggs 2 components [4,6-dimethyl-2-hydroxypyrimidine and 1,3-bis(4-nitrophenyl)urea] of the anticoccidial drug nicarbazin, used to treat poultry. Samples were extracted with acetonitrile, and the extracts were washed with hexane and evaporated to dryness before analysis by liquid chromatography/mass spectrometry with atmospheric pressure chemical ionization. By switching from positive to negative ion monitoring and using gradient elution, both components were measured within one run. The limit of quantitation of the assay was 10 ng/g for each component. The results of a preliminary feeding trial in which chickens were fed contamination levels of the drug are also reported.

Chromatography, Liquid↗

Oxygen transfer to slurries treated in a rotating drum operated at atmospheric pressure.

The objective of this work was to determine (1) the effect of rotational speed (N) and lifters on the oxygen transfer coefficient (k (L)) of a mineral solution and (2) the effect of solids concentration of a slurry soil-mineral solution on k (L), at a fixed value N (0.25 s(-1)); in both cases the treatment was carried out in an aerated rotating drum reactor (RDR) operated at atmospheric pressure. First, the k (L) for the mineral solution was in the range 6.38 x 10(-4)-7.69 x 10(-4) m s(-1), which was of the same order of magnitude as those calculated for closed rotating drums supplied with air flow. In general, k (L) of RDR implemented with lifters was superior or equal to that of RDR without lifters. For RDR implemented with lifters, k (L) increased with N in the range 6.65 x 10(-4)-10.51 x 10(-4) m s(-1), whereas k (L) of RDR without lifters first increased with N up to N = 0.102 s(-1), and decreased beyond this point. Second, regarding soil slurry experiments, an abrupt fall of k (L) (ca. 50%) at low values of the solid concentration (C (v)) and an asymptotic pattern at high C (v) were observed at N = 0.25 s(-1). These results suggest that mass transfer phenomena were commanded by the slurry properties and a semi-empirical equation of the form Sh = f(Re, Sc) seems to corroborate this finding.

Atmosphere↗

Dual parallel electrospray ionization and atmospheric pressure chemical ionization mass spectrometry (MS), MS/MS and MS/MS/MS for the analysis of triacylglycerols and triacylglycerol oxidation products.

Two mass spectrometers, in parallel, were employed simultaneously for analysis of triacylglycerols in canola oil, for analysis of triolein oxidation products, and for analysis of triacylglycerol positional isomers separated using reversed-phase high-performance liquid chromatography. A triple quadrupole mass spectrometer was interfaced via an atmospheric pressure chemical ionization (APCI) interface to two reversed-phase liquid chromatographic columns in series. An ion trap mass spectrometer was coupled to the same two columns using an electrospray ionization (ESI) interface, with ammonium formate added as electrolyte. Electrospray ionization mass spectrometry (ESI-MS) under these conditions produced abundant ammonium adduct ions from triacylglycerols, which were then fragmented to produce MS/MS spectra and then fragmented further to produce MS/MS/MS spectra. ESI-MS/MS of the ammoniated adduct ions gave product ion mass spectra which were similar to mass spectra obtained by APCI-MS. ESI-MS/MS produced diacylglycerol fragment ions, and additional fragmentation (MS/MS/MS) produced [RCO](+) (acylium) ions, [RCOO+58](+) ions, and other related ions which allowed assignment of individual acyl chain identities. APCI-MS of triacylglycerol oxidation products produced spectra like those reported previously using APCI-MS. APCI-MS/MS produced ions related to individual fatty acid chains. ESI-MS of triacylglycerol oxidation products produced abundant ammonium adduct ions, even for those molecules which previously produced little or no intact molecular ions under APCI-MS conditions. Fragmentation (MS/MS) of the [M+NH(4)](+) ions produced results similar to those obtained by APCI-MS. Further fragmentation (MS/MS/MS) of the diacylglycerol fragments of oxidation products provided information on the oxidized individual fatty acyl chains. ESI-MS and APCI-MS were found to be complementary techniques, which together contributed to a better understanding of the identities of the products formed by oxidation of triacylglycerols.

Chromatography, High Pressure Liquid↗

Analysis of malachite green and metabolites in fish using liquid chromatography atmospheric pressure chemical ionization mass spectrometry.

Malachite green (MG), a traditional agent used in aquaculture, is structurally related to other carcinogenic triphenylmethane dyes. Although MG is not approved for use in aquaculture, its low cost and high efficacy make illicit use likely. We developed sensitive and specific methods for determination of MG and its principal metabolite, leucoMG (LMG), in edible fish tissues using isotope dilution liquid chromatography atmosphere pressure chemical ionization mass spectrometry. MG and LMG concentrations were measured in filets from catfish treated with MG under putative use conditions (ca. 250 and 1000 ppb, respectively) and from commercial trout samples (0-3 and 0-96 ppb, respectively). Concentrations of LMG in edible fish tissues always exceeded those of MG. A rapid cone voltage switching acquisition procedure was used to simultaneously produce molecular ions for quantification and diagnostic fragment ions for confirmation of MG and metabolites. The accurate and precise agreement between diagnostic ion intensity ratios produced by LMG in authentic standards and incurred fish samples was used to unambiguously confirm the presence of LMG in edible fish tissue. This suggested the validity of using LMG as a marker residue for regulatory determination of MG misuse. Additional metabolites derived from oxidative metabolism of MG or LMG (demethylation and N-oxygenation) were identified in catfish and trout filets, including a primary arylamine which is structurally related to known carcinogens. The ability to simultaneously quantify residues of MG and LMG, and to confirm the chemical structure of a marker residue by using LC/MS, suggests that this procedure may be useful in monitoring the food supply for the unauthorized use of MG in aquaculture.

Aniline Compounds↗

Gas chromatographic-atmospheric pressure active nitrogen method for organomercury speciation in environmental samples.

Methods are presented for the determination of methylmercury in fish, water, urine, and sediments, and diorganomercury compounds in water. Two significant differences from previous methods are the use of methylene chloride extracting solvent which permits sample extracts to be concentrated to volumes as low as 0.1 mL, and use of a gas chromatograph interfaced to an atmospheric pressure active nitrogen (APAN) afterflow detector. Such a detector is very sensitive and selective for Hg at picogram levels. Thus, limits of detection were significantly enhanced.

Animals↗

Analysis of erythromycin by liquid chromatography/mass spectrometry using involatile mobile phases with a novel atmospheric pressure ionization source.

A critical limitation of electrospray ionization (ESI) liquid chromatography/mass spectrometry (LC/MS) sources is the susceptibility to blockage of interface orifices due to the deposition of involatile components from the sample and/or mobile phase. These components, including salts, buffers, and ion-pairing agents, can be essential to the performance of the chosen analytical method. We report here the performance enhancements provided by a novel atmospheric pressure ionization (API) source in the analysis of erythromycin A (ERY) using mobile phases that contain involatile components. The enhanced robustness of the new source is derived from the use of a continuous flow of aqueous solvent at the sampling cone orifice that maintains unobstructed ion transmission. The ESI mass spectral responses measured for ERY, using an LC separation that incorporates 10 mM sodium phosphate with and without 10 mM octane sulfonate, were monitored by repeated injections over 13-15 h total analysis time. Minimal effects on ESI mass spectral responses (integrated peak area) or chromatographic performance (peak shape, retention time) were observed during these studies. In the absence of the aqueous cleaning flow, complete loss of mass spectral responses and total blocking of the sampling cone was observed in less than 30 min. Responses for ERY spiked into chicken and beef liver, and catfish muscle at or below the regulatory level of interest (100 ppb), were quantified by internal standard calibration using this procedure. These results demonstrate the ability of a novel API-MS ion source to perform analyses that require the use of involatile mobile phase additives.

Animals↗

Determination of carbonyls using liquid chromatography-mass spectrometry with atmospheric pressure chemical ionization.

A liquid chromatographic method for the determination of aldehydes and ketones based on mass spectrometric detection is described. Recently developed modular derivatizing agents are employed for analysis. These hydrazine reagents, e.g. 4-dimethylamino-6-(4-methoxy-1-naphthyl)-1,3,5-triazine-2-hydrazine (DMNTH), react with the carbonyl compounds with the formation of the respective hydrazones, which are separated by HPLC-MS with atmospheric pressure chemical ionization in the positive mode. Electrospray ionization may also be used for analysis. Particular focus is directed on various calibration approaches, including external calibration with standard solutions and internal calibration with a hydrazone standard of cyclobutanone, an aldehyde not likely to occur in real samples. A second approach for internal calibration is based on the 13C2-labelled acetaldehyde hydrazone standard. Different calibration approaches may then be used for the analysis of real samples. Limits of detection range from 2 x 10(-8) to 5 x 10(-8) mol L-1 for a series of hydrazones, including hydrazones of saturated aldehydes with alkyl chain lengths from 1 to 7 carbon atoms, and hydrazones of selected unsaturated and aromatic aldehydes as well as ketone hydrazones.

Air Pollution, Indoor↗

Rapid analysis of stilbenes and derivatives from downy mildew-infected grapevine leaves by liquid chromatography-atmospheric pressure photoionisation mass spectrometry.

Resveratrol, trans-epsilon-viniferin and trans-delta-viniferin are the major stilbenes induced in downy mildew infected grapevine leaves. In addition, nine minor polyphenolic compounds, described as stilbenes derivatives, have been separated and detected among known stilbenes after a methanolic microextraction of small pieces (1-2 mg) from infected grapevine leaves with a rapid, qualitative and optimized HPLC method coupled to mass spectrometry using atmospheric pressure photoionisation (APPI-MS(n)). The characterization of unknown stilbenic derivatives as six resveratrol dimers, two dimethylated resveratrol dimers and a resveratrol trimer are reported. Therefore, structures have been proposed for the dimethylated resveratrol dimers. Use of an easy sample treatment and the LC-APPI-MS(n) method results in spectral data of these minor naturally occurring viniferin analogues.

Chromatography, Liquid↗

Identification of illudins in Omphalotus nidiformis and Omphalotus olivascens var. indigo by column liquid chromatography-atmospheric pressure chemical ionization tandem mass spectrometry.

Reversed-phase liquid chromatography was used to separate toxins in mushrooms of the genus Omphalotus. Crude ethyl acetate extracts of cultures were injected directly onto a 150 x 2 mm I.D. column packed with 3 microns octadecylsilica and eluted with a gradient of acetonitrile in 0.1% aqueous acetic acid at a flow-rate of 200 microliters/min. Monitoring of the column effluate by atmospheric pressure ionization tandem mass spectrometry allowed the identification of the toxins. The fungal toxins illudin M and illudin S were detected and identified for the first time in cultures of the Australian Omphalotus nidiformis and the North American Omphalotus olivascens var. indigo (Boletales, Basidiomycetes) and confirmed the valuable taxonomic character of illudins for the genus Omphalotus.

Agaricales↗