Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “diagnostic performance”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38Linked to original sources

Digital examination and transperineal ultrasonographic measurement of cervical length to assess risk of preterm delivery.

OBJECTIVE: To compare the diagnostic performance of cervical length measurement determined with transperineal ultrasonography and digital assessment of the cervix for the prediction of preterm delivery in patients with preterm labor. METHOD: 90 patients admitted to the hospital with the diagnosis of preterm labor and intact membrane underwent cervical length measurement by transperineal ultrasonography along with digital examination for cervical dilatation and effacement. The main outcome measure was delivery before 37 weeks' gestation. RESULTS: 32 patients (35.5%) delivered preterm. Receiver operative characteristic curve analysis revealed that cervical canal length < or = 28 mm measured by transperineal sonography had the highest diagnostic performance with a sensitivity of 78.1% and specificity of 82.7%. The sensitivity and specificity of digital examination were found to be 65.5%, 72.4% and 62.5%, 68.9% for the cervical dilatation > 2 cm and effacement > or = 40%, respectively. CONCLUSION: Transperineal ultrasonographic examination for cervical length is more accurate than digital examination for prediction of preterm delivery in patients presenting with preterm labor. Transperineal ultrasonographic examination of cervix is invaluable in the prediction of preterm delivery where transvaginal transducers are lacking or skilled staff are unavailable.

Adult↗

Detection of simulated interstitial lung disease and catheters with selenium, storage phosphor, and film-based radiography.

PURPOSE: To evaluate the diagnostic performance of storage phosphor and digital selenium radiography (DSR) with asymmetric and symmetric screen-film systems at different speeds in the detection of simulated interstitial lung disease and catheters. MATERIALS AND METHODS: Patterns of simulated interstitial lung disease and catheters were superimposed over an anthropomorphic chest phantom. Hard-copy images were generated at DSR (200-, 400-, and 600-speed), storage phosphor radiography (200- and 400-speed), and asymmetric (400-speed) and symmetric (200- and 400-speed) screen-film imaging. Surface doses were measured, and receiver operating characteristic analyses were performed. RESULTS: No statistically significant differences were found between the detector systems with the same speeds for each interstitial pattern. Significantly poorer results were found at 600-speed DSR than at 200-speed DSR. Detection of catheters and nodules over high-attenuation areas was significantly worse with the symmetric screen-film system than with the other detectors. The surface dose with the DSR system, without a grid, was about 50% less than that of the other detector systems, with grids, at the same speed. CONCLUSION: No significant difference was found in the diagnostic performance at DSR, storage phosphor radiography, and film-based radiography for simulated interstitial lung disease at corresponding speeds; there was a reduction in the surface dose of about 50% with the 400-speed DSR system.

Catheterization↗

Reagent strip testing is not sensitive for the screening of asymptomatic bacteriuria in pregnant women.

The objective of the study was to assess the diagnostic performance of the reagent strip in screening for asymptomatic bacteriuria in pregnant women using urine culture as a gold standard. This study comprised 204 asymptomatic pregnant women who attended their first antenatal care at Srinagarind Hospital, Khon Kaen University from April 1, 1999 to June 30, 1999. Women with symptoms of urinary tract infection, antibiotic treatment within the previous 7 days, pregnancy-induced hypertension, bleeding per vagina and history of urinary tract diseases were excluded. Urine specimens were collected by clean catched midstream urine technique for urinalysis, reagent strip test and urine culture. Diagnostic performance of reagent strip in terms of sensitivity, specificity, positive and negative predictive value was analyzed. Urine reagent strip test had a sensitivity of 13.9 per cent, a specificity of 95.6 per cent, a positive predictive value of 46.1 per cent, a negative predictive value of 80.6 per cent in detecting asymptomatic bacteriuria in pregnant women.

Adult↗

Contemporary use of complexed PSA and calculated percent free PSA for early detection of prostate cancer: impact of changing disease demographics.

OBJECTIVES: To assess the diagnostic performance of complexed prostate-specific antigen (cPSA), total PSA (tPSA), and calculated free/total PSA (f/t PSA) ratios in the differentiation of benign disease from prostate cancer (CaP) using a contemporary patient cohort. METHODS: The cPSA, tPSA, and calculated fPSA values were determined using the Bayer Immuno-1 system. To validate our calculated f/t PSA ratio, we also retrospectively measured fPSA using the Abbott AxSYM immunoassay system in archival pretreatment sera obtained between 1990 and 1997 from 362 men with clinically and biopsy-confirmed benign prostatic hyperplasia (n = 179) or CaP (n = 183). The diagnostic utility of tPSA, cPSA, and the calculated f/t PSA ratio was assessed using a contemporary test population consisting of sera prospectively collected between June 1999 and June 2000 from 3006 men who had recently undergone a systematic biopsy by urologists in clinical practices throughout the United States. This contemporary patient sample had biopsy diagnoses of either no evidence of malignancy (n = 1857) or CaP (n = 1149). All serum samples had tPSA values between 2.0 and 20.0 ng/mL. RESULTS: The measured versus calculated f/t PSA ratios had a Pearson's correlation coefficient of 0.9130 in the retrospectively studied population of 362 men. The areas under the receiver operating characteristic curves (ROC-AUCs) for the measured and calculated f/t PSA ratios were indistinguishable (69.6% versus 69.2%, respectively). In the contemporary population (n = 3006), the ROC-AUC for tPSA, cPSA, and the calculated f/t PSA ratio was 52.2%, 53.9%, and 58.4%, respectively. We also compared the diagnostic performance using published cutoffs for tPSA (greater than 4.0 ng/mL), cPSA (greater than 3.8 ng/mL), and the f/t PSA ratio (greater than 15% and greater than 25%) in tPSA reflex ranges of 2 to 20 ng/mL and 2 to 10 ng/mL. We found that both cPSA and the f/t PSA ratio (greater than 25% cutoff) outperformed tPSA and yielded similar results in terms of biopsies spared and cancers missed. CONCLUSIONS: The calculated f/t PSA ratio and cPSA perform equally well in terms of the improvement of specificity in the discrimination of benign disease and CaP. The f/t PSA ratio and cPSA provide clinical benefits over the use of tPSA alone, such as an increased sparing of unnecessary biopsies performed with a manageable degree of risk of delayed cancer detection.

Area Under Curve↗

Depiction of pelvic fractures using 3D volumetric holography: comparison of plain X-ray and CT.

OBJECTIVE: The goal of this study was to demonstrate the feasibility and test the diagnostic performance of a new technology, 3D volumetric holography, for imaging pelvic fractures. The management of pelvic fractures may be complex, and advanced imaging studies such as CT are frequently indicated. Multiplanar CT reformations and 3D renderings provide clinically useful and complementary display of the directly acquired CT data. With the recent availability of volumetric multiple exposure holograms, produced from serial image data, it is now possible to produce true 3D images of the pelvis. In the hologram, one may view the CT data in 3D or as individual planar slices constituting the whole 3D pelvis. The diagnostic performance of the volumetric multiple exposure holograms was tested against routine radiography, CT, and 3D volumetric CT reconstructions. MATERIALS AND METHODS: Routine radiography and CT were performed in 15 patients with suspected pelvic fractures. Volumetric multiple exposure holograms and 3D volumetric CT reconstructions were created from the CT data. Axial and multiplanar reformation CT images were used as the standard for fracture, diastasis, and intraarticular fragment detection. RESULTS: Radiograms detected 39 of 50 of the fractures and diastases and no intraarticular fragments. The 3D CT reconstructions and the holograms viewed as 3D objects alone missed two small fractures of the anterior column and one hip with intraarticular bone fragments. When the volumetric multiple exposure holograms were viewed as a 3D object and as individual planar slices constituting the whole, their results were the same as the standard. CONCLUSION: Volumetric multiple exposure holograms were as sensitive and specific as axial CT and multiplanar reformations in detecting fracture pathology. By containing and making available, from one image, both planar and 3D information, volumetric multiple exposure holograms detected subtle anatomical features that were hidden by overlapping structures in the radiographs and the 3D CT images.

Fractures, Bone↗

Multicenter evaluation of enhanced chemiluminescence labeled-antibody immunoassay (Amerlite-MAB) for free thyroxine.

The technical and diagnostic performance of the Amerlite-MAB enhanced luminescence assay for free thyroxine (FT4) was assessed in a multicenter evaluation trial. The euthyroid central 95% reference range for FT4 (1393 subjects) was 11.5-27.7 pmol/L (by cumulative frequency plot with two-tailed 2.5% cutoffs). Results (y) agreed with those of similar radioactive method (Amerlex-MAB FT4) (x): y = 1.06 x + 0.54, Sylx = 335.5, n = 235). Mean within-assay precision (CV) in six centers was 5.7% at 6 pmol/L and 2.6% at 51 pmol/L FT4; between-assay precision (CV) was 7.2% and 3.6%, respectively. Diagnostic performance was assessed in all patient groups usually encountered, including those with nonthyroidal illness and extreme binding-protein anomalies. In elderly euthyroid subjects, the proportion of above-normal FT4 values exceeded that in younger age-groups. These increases often accompanied normal estimates of thyrotropin and, in some cases, might have arisen by interference from medication that is taken more often by the elderly.

Adolescent↗

Classification of heart rate variability in patients with mild hypertension.

The diagnostic performance of two pattern classification methods to detect hypertension was evaluated in a population of 29 mildly hypertensive and 20 normal subjects. The heart rate variability (HRV) signal of each subject was recorded during rest and isometric handgrip exercise. Feature vectors composed of up to 6 features from both the time and frequency domain representation of the HRV signal were constructed and applied to a Bayes' likelihood classifier and a voting k-nearest neighbours classifier. Each subject was classified as hypertensive or normal, and the classification compared to the clinical diagnosis for each subject. The diagnostic performance of each classifier/feature vector combination was evaluated using the leave-one-out method. The best performance of 90% correct classifications was achieved using a nearest neighbour classifier, a Euclidean distance metric and 3 features. The Bayes' classifier achieved a best performance of 84% correct classification. The work shows promise for the detection of the autonomic disturbance which precedes and accompanies the hypertensive state.

Analysis of Variance↗

Two- and three-dimensional imaging modalities for the detection of caries. A comparison between film, digital radiography and tuned aperture computed tomography (TACT).

OBJECTIVES: To compare the diagnostic performance provided by two- (film and digital radiography) and three-dimensional imaging modalities (TACT slices and TACT pseudoholograms) in the detection of primary caries. METHODS: Forty-two extracted human posterior teeth were mounted and imaged with conventional film and direct digital radiography. Free-hand positioning of a dental X-ray source was used for all exposures. From the digital images, iteratively restored TACT slices and TACT pseudoholograms were generated. Film images were viewed on a viewbox. Digital format images were viewed on a high-resolution monitor. Eight observers used a five-point scale to score the presence or absence of occlusal and proximal caries using the four image modalities. Observers' assessments were compared with the histological examination of tooth sections. Possible differences in ROC curve areas among image modalities, observers, and surfaces were assessed by ANOVA. Intra- and interobserver reliability as indicated by intraclass correlation was also calculated. RESULTS: There were no statistically significant differences between the diagnostic performances of film, digital radiography, TACT slices and TACT pseudoholograms in the detection of caries (P = 0.310). Intraclass correlation indicated the highest concordance both within and between observers when film was used for the evaluation. CONCLUSIONS: Under the experimental conditions of this study, three-dimensional TACT images did not improve caries detection over film or digital radiography. Further research should investigate the effects of imaging variables on TACT's diagnostic efficacy.

Analysis of Variance↗

The value of fetal fibronectin in cervical and vaginal secretions and of ultrasonographic examination of the uterine cervix in predicting premature delivery for patients with preterm labor and intact membranes.

OBJECTIVE: We compared the diagnostic performances of fetal fibronectin assay of cervical and vaginal secretions and of transvaginal ultrasonographic evaluation of the uterine cervix in the prediction of preterm delivery of patients presenting with preterm labor and intact membranes. STUDY DESIGN: One hundred eight patients admitted to the hospital for preterm labor and with intact membranes underwent assay of fibronectin in the cervical and vaginal secretions and transvaginal ultrasonographic evaluation of the uterine cervix. The ultrasonographic parameters evaluated were cervical length, presence of funneling, and cervical index ([Funnel length + 1]/Cervical length). Outcome measures were occurrence of preterm delivery, defined as birth before the thirty-seventh week of gestation, and the admission-to-delivery interval. RESULTS: Forty-seven patients (43.5%) were delivered preterm. Receiver characteristic curve analysis showed that a level of fetal fibronectin in cervical secretions > or = 60 ng/ml had the highest diagnostic performance in predicting preterm delivery (sensitivity 80.9%, specificity 83.6%). Multiple stepwise logistic regression analysis indicated that the cervical index significantly improved the prediction of preterm delivery achieved by the fetal fibronectin assay. In patients with cervical secretion fibronectin levels > or = 60 ng/ml, survival analysis showed a shorter admission-to-delivery interval in the presence of an abnormal cervical index (p < or = 0.001). CONCLUSIONS: The assay of fetal fibronectin in cervical secretions is more accurate than ultrasonographic evaluation of the uterine cervix in the prediction of preterm delivery. Combined use of the fetal fibronectin assay and the cervical index improves the diagnostic efficiency and allows prediction of the admission-to-delivery interval, identifying a subgroup of patients who may require aggressive treatment.

Adult↗

Investigating the effects of vasodilator drugs on the turbulent sound caused by femoral artery stenosis using short-term Fourier and wavelet transform methods.

In this study, the effects of vasodilator drugs on the turbulent sound generation mechanisms during femoral artery stenoses were investigated using the wavelet analysis of the turbulent sounds to characterize these sounds before and after the injection of vasodilator drugs. Results showed that the injection of drugs drastically improved the diagnostic performance of the turbulent sounds in detecting stenoses by increasing the signal-to-noise ratio of the sounds. Results also suggested that the sound above 250 Hz was drastically increased in response to the injection of the vasodilator drug for the partially occluded cases. The turbulence sounds caused by partially occluded femoral arteries are directly related to the slope of baseline of blood flow and to the velocity of the flow. For the 0% occlusion case, initially, sounds were produced with the injection of drugs. However, the sounds totally disappeared when the slope of average blood flow was zero. These results show that the diagnostic performance of diastolic heart sounds associated with occluded arteries can be improved by using vasodilator drugs, which increase the acoustic energy in the first and second wavelet bandwidths due to the turbulence. The short-term Fourier transform (STFT) method was also applied to the same data base. Results using the STFT showed somewhat similar power distributions in that the acoustical power above 250 Hz was increased after the injection of drugs for the occluded cases. However, the WT method provided better time-frequency resolution than the STFT method, showing details of the change in the frequency characteristics with respect to time after the injection of drug.

Animals↗

False-negative and false-positive errors in abdominal pain evaluation: failure to diagnose acute appendicitis and unnecessary surgery.

OBJECTIVES: To test the hypothesis that physician errors (failure to diagnose appendicitis at initial evaluation) correlate with adverse outcome. The authors also postulated that physician errors would correlate with delays in surgery, delays in surgery would correlate with adverse outcomes, and physician errors would occur on patients with atypical presentations. METHODS: This was a retrospective two-arm observational cohort study at 12 acute care hospitals: 1) consecutive patients who had an appendectomy for appendicitis and 2) consecutive emergency department abdominal pain patients. Outcome measures were adverse events (perforation, abscess) and physician diagnostic performance (false-positive decisions, false-negative decisions). RESULTS: The appendectomy arm of the study included 1, 026 patients with 110 (10.5%) false-positive decisions (range by hospital 4.7% to 19.5%). Of the 916 patients with appendicitis, 170 (18.6%) false-negative decisions were made (range by hospital 10.6% to 27.8%). Patients who had false-negative decisions had increased risks of perforation (r = 0.59, p = 0.058) and of abscess formation (r = 0.81, p = 0.002). For admitted patients, when the inhospital delay before surgery was >20 hours, the risk of perforation was increased [2.9 odds ratio (OR) 95% CI = 1.8 to 4.8]. The amount of delay from initial physician evaluation until surgery varied with physician diagnostic performance: 7.0 hours (95% CI = 6.7 to 7.4) if the initial physician made the diagnosis, 72.4 hours (95% CI = 51.2 to 93.7) if the initial office physician missed the diagnosis, and 63.1 hours (95% CI = 47.9 to 78.4) if the initial emergency physician missed the diagnosis. Patients whose diagnosis was initially missed by the physician had fewer signs and symptoms of appendicitis than patients whose diagnosis was made initially [appendicitis score 2.0 (95% CI = 1.6 to 2.3) vs 6.5 (95% CI = 6.4 to 6.7)]. Older patients (>41 years old) had more false-negative decisions and a higher risk of perforation or abscess (3.5 OR 95% CI = 2.4 to 5.1). False-positive decisions were made for patients who had signs and symptoms similar to those of appendicitis patients [appendicitis score 5.7 (95% CI = 5.2 to 6.1) vs 6.5 (95% CI = 6.4 to 6.7)]. Female patients had an increased risk of false-positive surgery (2.3 OR 95% CI = 1.5 to 3.4). The abdominal pain arm of the study included 1,118 consecutive patients submitted by eight hospitals, with 44 patients having appendicitis. Hospitals with observation units compared with hospitals without observation units had a higher "rule out appendicitis" evaluation rate [33.7% (95% CI = 27 to 38) vs 24.7% (95% CI = 23 to 27)] and a similar hospital admission rate (27.6% vs 24.7%, p = NS). There was a lower miss-diagnosis rate (15.1% vs 19.4%, p = NS power 0.02), lower perforation rate (19.0% vs 20.6%, p = NS power 0.05), and lower abscess rate (5.6% vs 6.9%, p = NS power 0.06), but these did not reach statistical significance. CONCLUSIONS: Errors in physician diagnostic decisions correlated with patient clinical findings, i.e., the missed diagnoses were on appendicitis patients with few clinical findings and unnecessary surgeries were on non-appendicitis patients with clinical findings similar to those of patients with appendicitis. Adverse events (perforation, abscess formation) correlated with physician false-negative decisions.

Abdominal Pain↗

Anatomy of a meta-analysis: a critical review of "exercise echocardiography or exercise SPECT imaging? A meta-analysis of diagnostic test performance".

BACKGROUND: Accurate diagnosis of coronary heart disease has the potential to contribute substantially to cost-effective delivery of health services. Recent work by Fleischmann et al (JAMA 1998;280:913-20) represents an effort to summarize the accuracy of exercise echocardiography and exercise single photon emission computed tomography (SPECT). METHODS AND RESULTS: A critique of the previous work was constructed, obtaining the 44 articles used. These articles were reviewed and summarized with established techniques for meta-analysis. The studies summarized by Fleischmann et al were found to be significantly heterogeneous (echocardiography and SPECT, both P<.001). In the SPECT cohort, combination of different radioisotopes and reading techniques, and inclusion of reports using experimental techniques, were sources of heterogeneity. In the echocardiography cohort, experimental techniques and an individual series were identified. When the sample was stratified for sources of heterogeneity, it was found that there was no significant difference in diagnostic accuracy between the echocardiography and SPECT techniques used in current clinical practice. Meta-regression with summary receiver operating characteristic curve techniques, after adjustment of the model for multicolinearity and outliers, revealed that there were no significant differences between SPECT as used in current clinical practice and echocardiography. CONCLUSION: The report by Fleischmann et al contains serious flaws that limit its validity and generalizability.

Echocardiography↗

Fully automatic diagnostic system for early- and late-onset mild Alzheimer's disease using FDG PET and 3D-SSP.

PURPOSE: The purpose of this study was to design a fully automatic computer-assisted diagnostic system for early- and late-onset mild Alzheimer's disease (AD). METHODS: Glucose metabolic images were obtained from mild AD patients and normal controls using positron emission tomography (PET) and( 18)F-fluorodeoxyglucose (FDG). Two groups of 20 mild AD patients with different ages of onset were examined. A fully automatic diagnostic system using the statistical brain mapping method was established from the early-onset (EO) and late-onset (LO) groups, with mean ages of 59.1 and 70.9 years and mean MMSE scores of 23.3 and 22.8, respectively. Aged-matched normal subjects were used as controls. We compared the diagnostic performance of visual inspection of conventional axial FDG PET images by experts and beginners with that of our fully automatic diagnostic system in another 15 EO and 15 LO AD patients (mean age 58.4 and 71.7, mean MMSE 23.6 and 23.1, respectively) and 30 age-matched normal controls. A receiver operating characteristic (ROC) analysis was performed to compare data. RESULTS: The diagnostic performance of the automatic diagnostic system was comparable with that of visual inspection by experts. The area under the ROC curve for the automatic diagnostic system was 0.967 for EO AD patients and 0.878 for LO AD patients. The mean area under the ROC curve for visual inspection by experts was 0.863 and 0.881 for the EO and LO AD patients, respectively. The mean area under the ROC curve for visual inspection by beginners was 0.828 and 0.717, respectively. CONCLUSION: The fully automatic diagnostic system for EO and LO AD was able to perform at a similar diagnostic level to visual inspection of conventional axial images by experts.

Age of Onset↗

Dose optimization of contrast-enhanced carotid MR angiography.

The purpose of this work was to compare the diagnostic performance of a single-contrast or a double-contrast dose of carotid contrast-enhanced MR angiography (MRA). One-hundred nineteen patients (mean age 65+/-14.4 years) underwent carotid contrast-enhanced MRA with a standardized protocol (repetition time/echo 3.73 ms/1.38 ms, flip-angle 25 degrees, acquisition-time 19 s, voxel size 1.2 x 1.2 x 0.9 mm3) on a 1.5-T scanner (Sonata, Siemens-Medical-Systems) using a neck phased-array coil. Contrast agent was administered intravenously at a rate of 3.0 ml/s, either as a single dose (n=57; 0.1 mmol/kg body weight) or as a double dose (n=62; 0.2 mmol/kg body weight) of meglumine gadoterate (0.5 M/l), followed by 30 ml saline. Qualitative image analysis was performed on maximum intensity projections using a five-point scale. Signal intensities were measured at three different vascular levels on both sides to assess the contrast-to-noise ratios (CNRs). Image quality was rated as good or excellent in all cases. A double dose did not influence the efficacy of carotid enhancement (CNR single dose 69.12+/-19.8; CNR double dose 70.01+/-20.7; p = 0.81) compared with a single dose. In both dose groups the mean CNRs were inversely related to bodyweight, despite adjusted contrast volumes (p=0.0005). Double-dose contrast-enhanced carotid MRA is not superior to single-dose MRA, as overall diagnostic performance and quantitative contrast enhancement are equal. Being more cost-efficient, a single-dose administration of contrast agent is recommended for MRA of the carotid arteries.

Adult↗

The influence of viewing conditions on radiological diagnosis of periapical inflammation.

OBJECTIVES: To determine the effect of viewing conditions upon diagnosis of early periapical inflammatory pathosis on intra-oral radiographs, and to examine the effect of observer experience upon diagnostic performance in this task. METHODS: 50 observers examined 18 periapical radiographs using three different viewing conditions (room lighting; viewing box; viewing box with x2 magnification and masking). Their diagnoses were compared with an 'expert' diagnosis provided by repeated viewings of the films by two dental radiologists. Sensitivities and specificities were determined. RESULTS: When 'ideal' viewing conditions were used, optimal sensitivity (78%) and specificity (78%) were obtained. Use of a viewing box was associated with significantly higher specificity than the use of room lighting (P = 0.0016). Use of masking and x2 magnification was associated with significantly higher sensitivity than a viewing box alone (P = 0.004). There were few significant differences in diagnostic performance between observers, but qualified dental staff had significantly higher specificities than 4th year (P = 0.01) and 5th year (P = 0.01) students when a viewing box was used alone. CONCLUSIONS: This study on early periapical inflammatory pathosis gives support to guidelines which recommend the use of a viewing box, x2 magnification and masking for interpreting intra-oral radiographs. It also suggests that observer experience may influence interpretation of early periapical pathosis.

Clinical Competence↗

Pulmonary embolism: comparison of cut-film and digital pulmonary angiography.

PURPOSE: To compare "cut-film" (film hard-copy) angiography (CFA) with digital pulmonary angiography in the detection of pulmonary embolism (PE). MATERIALS AND METHODS: Thirty-six adult patients (39 lungs) underwent selective digital pulmonary angiography for suspected PE. Imaging was repeated in one selected projection by using cut film. The standard was consensus interpretation of both CFA and digital angiographic images and clinical course. Three vascular radiologists subsequently reviewed the digital and cut-film images in a blinded fashion and ranked the likelihood of the presence of PE on a five-point scale. The two modalities were compared by means of receiver operating characteristic (ROC) analysis. Image quality (i.e., sharpness, opacification of subsegmental vessels, and exposure) was judged on a three-point scale. The highest-order pulmonary artery branch seen on each study was recorded. RESULTS: ROC curve analyses for all three operators showed similar diagnostic performance for digital pulmonary angiography and CFA, with one operator showing better performance with digital subtraction angiography than with CFA (P = .04). Compared with the final diagnosis, single-plane digital pulmonary angiography had higher sensitivity for the detection of PE than had CFA. The specificity was 100% for both modalities. The mean score in patients with findings positive for PE was higher in the digital pulmonary angiography group than in the CFA group (P < .005). There was no difference in the mean score in patients who did not have a PE. There also was no difference in the smallest detectable subsegmental branch (P = .87) or in the average estimate of image quality. CONCLUSION: Selective digital pulmonary angiography and CFA offer similar diagnostic performance and image quality. Digital pulmonary angiography is a reasonable alternative to CFA in the diagnosis of PE.

Adult↗

Comparison between two methods in the determination of circulating chromogranin A in neuroendocrine tumors (NETs): results of a prospective multicenter observational study.

Several methods for analyzing CgA using either monoclonal or polyclonal antibodies have been developed, which differ in their diagnostic performance. The present paper describes the results of a prospective multicenter study aimed at comparing the clinical value of the two most widely used commercially available CgA assay kits in patients affected by neuroendocrine tumors (NETs). Two hundred sixty-one patients from 40 different centers and 99 healthy subjects were evaluated. CgA levels were measured with two different methods, a two-step immunoradiometric assay (IRMA) and an enzyme-linked immunosorbent assay (ELISA). CgA was measured centrally by two reference laboratories, one of which used IRMA and the other ELISA, and it was measured by the participating institutions with the method routinely used by each of them. The major findings of the present study were: (i) the two assays for the determination of CgA present good diagnostic performance; (ii) both assays are robust and guarantee comparable results when applied in different settings (central vs local laboratory); (iii) the negative/positive cutoff points (87 ng/mL for IRMA and 21.3 U/L for ELISA) were established according to standardized criteria; (iv) the results obtained with the two assays in basal clinical samples of patients affected by NETs show an apparently satisfactory correlation (rs = 0.843, p < 0.0001). However, a possibly clinically meaningful 36% discordance rate was found. These findings support the hypothesis that the two CgA kits might provide partially different information.

Adult↗

Quantitative rest technetium-99m tetrofosmin imaging in predicting functional recovery after revascularization: comparison with rest-redistribution thallium-201.

OBJECTIVES: This study was undertaken to 1) compare the regional myocardial tracer distributions between rest technetium (Tc)-99m tetrofosmin and rest-redistribution thallium (Tl)-201 images in patients with coronary artery disease and left ventricular dysfunction; and 2) assess the comparative values of these agents for predicting functional recovery after revascularization. BACKGROUND: Tc-99m tetrofosmin is a new myocardial perfusion imaging agent, but its role for detecting viable myocardium is still unclear. METHODS: Thirty-six patients with coronary artery disease and left ventricular dysfunction underwent rest Tc-99m tetrofosmin, rest-redistribution Tl-201 and gated blood pool scintigraphy. In 21 patients with successful revascularization confirmed by follow-up angiography, gated blood pool scintigraphy was repeated after revascularization. Optimal threshold cutoffs to separate reversible from irreversible dysfunction were determined by receive operating characteristic analysis. RESULTS: Regional Tc-99m tetrofosimin activity highly correlated with redistribution Tl-201 activity (r = 0.93). The diagnostic performance for predicting functional recovery, as measured by the area under the receiver operating characteristic curves, measured 0.66 +/- 0.07 (mean +/- SD) for Tc-99m tetrofosmin and 0.67 +/- 0.07 for Tl-201 (p = 0.60, 96.7% power to detect difference in area of 0.10). The optimal threshold cutoffs for viability were considered to be 50% of peak activity for Tc-99m tetrofosmin and 55% of peak activity for Tl-201. The positive and negative predictive values for reversible dysfunction were, respectively, 69% and 82% for Tc-99m tetrofosmin and 69% (p = 0.99 vs. Tc-99m tetrofosmin) and 71% (p = 0.66 vs. Tc-99m tetrofosmin) by Tl-201. CONCLUSIONS: The diagnostic performance of quantitative rest Tc-99m tetrofosmin imaging in predicting functional recovery after revascularization is comparable to that of rest-redistribution Tl-201.

Aged↗