Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Torque”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38Linked to original sources

The relationships among peak torque, mean power output, mechanomyography, and electromyography in men and women during maximal, eccentric isokinetic muscle actions.

The purpose of the present investigation was to examine the velocity-related patterns of peak torque (PT), mean power output (MP), mechanomyographic (MMG) amplitude, and electromyographic (EMG) amplitude of the vastus lateralis (VL) muscle in men and women during maximal, eccentric isokinetic muscle actions of the leg extensors. Eight women [mean (SD)] [aged 23 (3) years] and seven men [aged 23 (2) years] volunteered for this investigation. Their PT was measured on a calibrated dynamometer at randomly ordered velocities of 30, 90, and 150 degrees x s(-1). A piezoelectric MMG recording sensor was placed between bipolar surface EMG electrodes (Ag-AgCl) over the VL muscle. Their MP was determined using the dynamometer software. The results indicated no sex-related differences (P > 0.05) for the patterns of PT, MP, MMG amplitude, or EMG amplitude across velocity. The normalized values for MP and MMG amplitude increased (P<0.05) from 30 to 150 degrees x s(-1) (30 degrees x s(-1) <90 degrees x s(-1) < 150 degrees x s(-1)), while PT and EMG amplitudes remained unchanged across velocity. The results indicated close associations between the velocity-related patterns of MP and MMG amplitudes as well as PT and EMG amplitudes. Thus, MMG amplitude reflected the velocity-related changes in muscle power output, but not torque production, while EMG amplitude reflected torque production, but not muscle power output. During maximal, eccentric isokinetic muscle actions, EMG and MMG signals provided unique information regarding the electrical and mechanical aspects of muscle strength and power.

Adult↗

EMG activity and voluntary activation during knee-extensor concentric torque generation.

This study was designed to re-examine and compare the neural drive of the knee extensors during isokinetic concentric muscular actions by means of the twitch interpolation technique (activation level, AL) and surface electromyographic (EMG) recordings (root mean square, RMS). Torque, AL and RMS amplitudes of three knee extensors and one knee flexor were measured in nine subjects during maximal and sub-maximal voluntary contractions, performed under concentric (60 degrees.s(-1) and 120 degrees.s(-1); Con60 and Con120, respectively) and isometric (Iso) conditions. Mean (SD) maximal voluntary torque was significantly lower ( P<0.01) during concentric contractions [Con60: 208.6 (26.8) Nm and Con120: 184.7 (26.4) Nm] compared with isometric contractions [327.4 (52.0) Nm]. A significantly lower AL ( P<0.05) was recorded during Con60 [80.9 (8.8)%] compared with Iso [87.9 (5.1)%] and Con120 [88.2 (6.6)%] maximal contractions. Simultaneously, a lower knee extensor average RMS amplitudes (av.RMS) was measured during Con60 maximal contractions compared with Iso and Con120 maximal contractions. The antagonist biceps femoris RMS values were not different between maximal Iso, Con60 and Con120 contractions. During sub-maximal voluntary contractions, the RMS/torque relationships were similar whatever the muscle considered (vastus lateralis, vastus medialis or rectus femoris) and the AL/av.RMS relationships did not reveal any noticeable differences between each contractile condition. The results of the present study indicate that av.RMS and AL describe similarly the neural drive during maximal and sub-maximal efforts and indicate that during maximal voluntary efforts, neural drive is dependent upon concentric angular velocity (up to 120 degrees.s(-1)). Thus, our results suggest that when applying different contractile conditions, the torque output is regulated via complex interactions between intrinsic muscular properties and the neural drive.

Adult↗

Reliability and validity of the Biodex system 3 pro isokinetic dynamometer velocity, torque and position measurements.

This study quantitatively assessed the mechanical reliability and validity of position, torque and velocity measurements of the Biodex System 3 isokinetic dynamometer. Trial-to-trial and day-to-day reliability were assessed during three trials on two separate days. To assess instrument validity, measurement of each variable using the Biodex System 3 dynamometer was compared to a criterion measure of position, torque and velocity. Position was assessed at 5 degrees increments across the available range of motion of the dynamometer. Torque measures were assessed isometrically by hanging six different calibrated weights from the lever arm. Velocity was assessed (30 degrees/s to 500 degrees/s) across a 70 degrees arc of motion by manually accelerating the weighted lever arm. With the exception of a systematic decrease in velocity at speeds of 300 degrees/s and higher, the Biodex System 3 performed with acceptable mechanical reliability and validity on all variables tested.

Humans↗

Effect of local blood circulation and absolute torque on muscle endurance at two different knee-joint angles in humans.

The effects of the local blood circulation and absolute torque on muscle endurance at different knee-joint angles were determined. The rate of muscle deoxygenation (using near-infrared spectroscopy), and the rate of muscle fatigue (using the slope of integrated electromyography, iEMG) were evaluated concurrently. Nine healthy subjects performed submaximal (50% maximal voluntary contraction. MVC) static knee extension at 50 degrees (extended position, EXT) and 90 degrees (flexed position, FLEX) joint angles until the target torque could no longer be maintained: that time was measured as the endurance time. They exercised with the circulation occluded (OCCL), and without (FREE) to study the possible effects of the local circulation. Although MVC torque was independent of joint angle [mean (SD) FLEX 250.6 (51.7) Nm and EXT 246.5 (46.6) N x m], significantly shorter (P<0.01) endurance time in FLEX [FREE 71.1 (10) s and OCCL 63.1 (8.8) s] than at EXT [FREE 115.3 (30) s and OCCL 106.7 (29.1) s] were obtained in both circulatory conditions. The iEMG-time slope was significantly greater in FLEX at the proximal and distal portion (P<0.05) in both circulatory conditions. Muscle deoxygenation rate in OCCL was significantly greater (P<0.05) at FLEX [20.8 (8.0)%] than EXT [10.9 (4.0)%]. The results would suggest that different knee-joint angle affects muscle endurance even if the local circulation is controlled. Circulatory disturbance would further reduce muscle endurance in EXT, but not in FLEX. Because of the greater muscle internal force in FLEX, local blood flow might be already limited even with a free circulation. The greater muscle deoxygenation and muscle fatigability would be related to the shorter muscle endurance in FLEX.

Adult↗

Influence of lever arm and stabilization on measures of hip abduction and adduction torque obtained by hand-held dynamometry.

OBJECTIVE: To examine the reliability of clinical techniques for testing hip abductor and adductor muscle performance. DESIGN: Repeated measures. SETTING: Academic laboratory. PARTICIPANTS: A sample of 21 healthy subjects (12 men, 9 women) between 22 and 31 years of age. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Reliability of repeated measures was estimated by calculating intraclass correlation coefficients. Torque production capability was calculated by multiplying force output obtained with a hand-held dynamometer by the length of the resistance lever arm. RESULTS: The reliability of abduction testing was greatest in the long-lever condition. Adduction test reliability was greatest in the long-lever condition with bench stabilization. The maximal hip abduction torque tested in the long-lever position was significantly greater (t(20)=9.21, P<.001) than that in the short-lever position. The maximal hip adduction torque occurred using a long lever for resistance application and a bench to stabilize the nontest leg (F(1,20)=15.64, P=.001). CONCLUSIONS: Muscle performance testing of hip abductors and adductors with a hand-held dynamometer can be performed with good to excellent intratester and intertester reliability. Hip abduction testing is best performed with a long lever. Hip adduction is best performed with a long lever and a bench to stabilize the nontest extremity.

Adult↗

Effects of eccentric training on torque-angular velocity-power characteristics of elbow flexor muscles in older women.

The purpose of this study was to investigate the potential of eccentric training to improve elbow flexor muscle power in elderly subjects. Fourteen older female volunteers (age range 60-78 years) were randomly assigned into either a training group (TG) or a control group (CG). For the TG, the 21-session 7-week eccentric training program consisted of 5x6 eccentric muscle actions at 60-100% of concentric three maximal repetitions. Before and after training, maximal elbow flexions were performed against increasing inertia. Maximal isokinetic elbow flexions at four angular velocities (eccentric actions, -60 degrees s(-1), -30 degrees rads(-1); concentric actions, 30, 60 degrees s(-1)) and maximal isometric actions were also performed. Maximal power (Pmax) and an index of maximal shortening velocity (VImax)were determined. For all action conditions, the myoelectric activities of the biceps and the triceps brachii muscles were recorded and quantified as a root mean square (RMS) value. In the TG, maximal torque developed under isometric, isokinetic and inertial conditions increased significantly after training (ranging from 11 to 19%). Pmax and VImax also increased significantly (31.3 and 25.9%, respectively). These parameters remained unchanged in the CG. The RMS activity of the biceps and triceps muscles was not affected by eccentric training for all action conditions excepting the eccentric condition at -30 degrees s(-1) where the RMS activity of the biceps increased significantly. The gains in maximal torque, Pmax and VImax observed after training would result more from intramuscular modifications than from changes in muscular activity, except for eccentric condition at -30 degrees s(-1) where the torque gains could also be partly explained by a reduction in inhibition of the motor unit pool.

Aged↗

Surface electromyography and peak torque of repetitive maximum isokinetic plantar flexions in relation to aspects of muscle morphology.

This study investigates the relationships between surface electromyography (EMG [Mean frequency of the power spectrum (MNF)]) and peak torque variables obtained during 100 maximum concentric plantar flexions with the right limb at 60 degrees s(-1) and different muscle morphological variables. Surface EMG was recorded from the right gastrocnemius lateralis and muscle biopsies were taken from the same site as the EMG electrodes were positioned. Muscle fibre area and fibre type composition were determined on serial muscle cross sections using both histochemistry (myofibrillar adenosine triphosphatase) and immunohistochemistry (monoclonal antibodies against specific myosin heavy chain isoforms). Forty-three female and nine male students participated in the study. Gastrocnemius lateralis contained predominantly type I fibres (50%) and type IIA fibres (40%) in both sexes and large individual differences were found. Principal component analysis (PCA) was used for the intercorrelation analyses, and projection to latent structures (PLS) was used for the multivariate regression analysis. MNF correlated positively with different fibre areas and with the proportion of type I fibres. Fibre areas and sex were the most important factors in the regression of maximum peak torque. High proportion of type I fibres and sex were the most important regressors of peak torque endurance normalised for lean body mass. More studies are needed to understand the complex interrelationships between intrinsic muscle properties and the frequency content of the surface EMG before theoretical models can be formulated that incorporate both fibre areas and fibre type proportions.

Adult↗

Male torque strength in simulated oil rig tasks: the effects of grease-smeared gloves and handle length, diameter and orientation.

This paper examines the effects of two glove conditions and selected handle and task characteristics on tightening (clockwise) torques on cylindrical handles in simulated oil rig tasks. Ten males exerted MVC torques with the right hand on nine handles with different length-diameter combinations (3.8, 7.6, and 12.7 cm in length with 3.8, 6.7, and 8.4 cm in diameter) with dry and grease-smeared gloves in two orientations. The results showed a 50% reduction of torque when using grease-smeared glove compared to dry glove; a 15% increase with the long handle compared to the short one; a 25% increase with the medium diameter handle compared to the small one; and a 12% increase with the horizontally oriented handle compared with the vertical one. There were important interaction effects also.

Adult↗

Viscoelastic dynamics of actin filaments coupled to rotary F-ATPase: curvature as an indicator of the torque.

ATP synthase (F-ATPase) operates as an electrochemical-to-mechanical-to-chemical energy transducer with an astounding 360 degrees rotary motion of subunits epsilongammac(10-14) (rotor) against delta(alphabeta)(3)ab(2) (stator). The enzyme's torque as a function of the angular reaction coordinate in relation to ATP-synthesis/hydrolysis, internal elasticity, and external load has remained an important issue. Fluorescent actin filaments of micrometer length have been used to detect the rotation as driven by ATP hydrolysis. We evaluated the viscoelastic dynamics of actin filaments under the influence of enzyme-generated torque, stochastic Langevin force, and viscous drag. Modeling with realistic parameters revealed the dominance of the lowest normal mode. Because of its slow relaxation (approximately 100 ms), power strokes of the enzyme were expected to appear strongly damped in recordings of the angular velocity of the filament. This article describes the theoretical background for the alternative use of the filament as a spring balance. The enzyme's angular torque profile under load can be gauged by measuring the average curvature and the stochastic fluctuations of actin filaments. Pertinent experiments were analyzed in the companion paper.

Actin Cytoskeleton↗

Multijoint movement control: the importance of interactive torques.

The underlying mechanisms of the neural control of movement have long been explored, with a focus primarily on central control aspects and often overlooking the intrinsic mechanical properties of the motor system. To fully understand the control and regulation of movements, the biomechanical properties of the moving subject, specifically interactive torques, must be considered in the design, evaluation, and interpretation of empirical data. We first discuss the difficulty of extrapolating information from a wide variety of tasks due to their varying inherent task constraints. Examples are subsequently given where a biomechanical perspective provides a more informative interpretation of existing data. Finally, we focus on research examining the role of interactive torques with a discussion of how discoordinated movements may be explained by an inability to modulate interactive torques. Inclusion of biomechanical considerations in motor control research is a step toward incorporating multilevel methodologies and interpretations into the field, and providing a more comprehensive understanding of the neural control and regulation of movement.

Biomechanical Phenomena↗

Human elbow joint torque is linearly encoded in electromyographic signals from multiple muscles.

When the central nervous system (CNS) develops a muscular activation pattern to accomplish a particular isometric task, it clearly uses information concerning the external task requirements. These task requirements serve as inputs to neural transformations that output muscular activations. However, the nature of the inputs is not exactly known. Electromyographic (EMG) signals from eight muscles spanning the human elbow, as well as the total joint torque, were collected during a submaximal isometric flexion/extension task at a single joint angle. The EMG data, without any torque information, were subjected to principal components analysis. We found that 98% of EMG data variation could be described by two principal components the first resembled the joint torque and the second resembled the sum of the EMG signals from all eight muscles. The findings suggest that the CNS encodes these two quantities during isometric tasks.

Elbow Joint↗

Cortical bone remodeling/tooth movement ratio during maxillary incisor retraction with tip versus torque movements.

The validity of the postulate "bone traces tooth movement" was examined on 40 Angle Cl II cases. It was hypothesized that a 1:1 cortical bone remodeling/tooth movement ratio is preserved during maxillary incisor retraction. The sample was divided into retraction with tip (13 patients), retraction with torque (18 patients), and control (9 patients) groups. Two time point cephalograms were analyzed with two superimposition techniques, SN at S and a newly developed static tooth analysis, with the maxillary left central incisor serving as a reference object. In both retraction with tip and retraction with torque groups, the postulate bone traces tooth movement was not preserved and a bone remodeling/tooth movement ratio of 1:2 and 1:2.35 was obtained, respectively. In retraction with tip movement, the apical one third of the root tipped labially reducing the superior area of labial maxillaris by 19%. However, due to the compensating effect of the retraction movement, no apex approximation to the labial cortical plate occurred (eliminating the hazard of root resorption, dehiscence, or fenestration). In retraction with torque movement, the increase in both superior (28%) and inferior (65%) labial maxillaris areas was indicative for the hazard of root approximation to the palatal cortical bone. It is recommended to use the 1:2 bone remodeling/tooth movement ratio as a guideline to determine the biocompatible range of orthodontic tooth movements. Furthermore, a judicious interplay between the two modes of retraction can prevent major biologic impairments associated with the ratio and can extend the orthodontic range of treatment.

Bone Remodeling↗

[Anticipatory postural adjustments associated with arm flexion: interest of vertical torque].

OBJECTIVE: To find a biomechanical parameter able to characterize postural adjustments in different movement conditions. METHODS: The arm-raising movement performed during the upright human position imposes a vertical torque (Tz) that can be measured by a force plate-form. This torque was studied in ten healthy young subjects with opto electronic system Vicon 370. The subjects stood on a force platform, performed shoulder flexion of their right arm, to grasp a handle in front of them, in five conditions : self-paced at 3 different velocities (slow, medium, maximal), triggered by an auditory signal, loaded (1 kg attached to the wrist), all at maximal velocity. In a sixth condition, the arm was passively displaced by an experimenter. RESULTS: Tz displayed a negative phase (counter-clock wise body rotation) in all conditions. A positive phase occurred prior to the negative one, and preceded movement onset only if the movement was voluntary. In the triggered condition, the positive phase of Tz was delayed (- 60 ms) compared to the self-paced condition at maximal velocity (- 155 ms). However Tz onset latency was modified neither by load nor velocity. Tz amplitude increased with increasing velocity, load and in a reaction time condition. CONCLUSIONS: The vertical torque Tz, especially its positive phase gives useful informations about the latency, duration and intensity of the postural preparation related to a voluntary movement, according to the movement parameters. Tz is therefore able to characterise postural adjustments in all conditions, even with low movement velocity.

Adaptation, Physiological↗

Resonance frequency and removal torque analysis of implants with turned and anodized surface oxides.

The present experimental study was designed to address two issues. The first was to investigate whether oxide properties of titanium implants influenced bone tissue responses after an in vivo implantation time of six weeks. If such a result was found, the second aim was to investigate which oxide properties are involved in such bone tissue responses. Screw-shaped implants with a wide range of oxide properties were prepared by electrochemical oxidation methods, where the oxide thickness varied in the range of 200 nm to 1000 nm. The surface morphology was prepared in two substantially different ways, i.e. barrier and porous oxide film structures. The micropore structure revealed pore sizes of 8 microm in diameter, with a range in opening area from 1.27 microm 2 to 2.1 microm 2. Porosity ranged from 12.7% to 24.4%. The crystal structures of the titanium oxide were amorphous, anatase and a mixture of anatase and rutile type. The chemical compositions consisted mainly of TiO2. Surface roughness ranged from 0.96 microm to 1.03 microm (Sa). Each group of test samples showed its own, defined status with respect to these various parameters. The oxide properties of turned commercially pure titanium implants were used in the control group, which was characterized by an oxide thickness of 17.4 +/- 6.2 nm, amorphous type in crystallinity, TiO2 in chemical composition, and a surface roughness of 0.83 microm (Sa). Bone tissue responses were evaluated by resonance frequency measurements and removal torque tests that were undertaken six weeks after implant insertion in rabbit tibia. Implants that had an oxide thickness of approximately 600, 800 and 1000 nm demonstrated significantly stronger bone responses in the evaluation of removal torque values than did implants that had an oxide thickness of approximately 17 and 200 nm (P < 0.05). However, there were no difference between implants with oxide thicknesses of 17 and 200 nm (P = 0.99). It was concluded that oxide properties of titanium implants, which include oxide thickness, micropore configurations and crystal structures, greatly influence the bone tissue response in the evaluation of removal torque values. However, it is not fully understood whether these oxide properties influence the bone tissue response separately or synergistically.

Animals↗

Correlation of insertion torques with bone mineral density from dental quantitative CT in the mandible.

OBJECTIVE: The aim of this study was to establish a correlation between bone mineral density measured preoperatively with dental computed tomography (CT), and insertion torque of screw-shaped dental implants. MATERIAL AND METHODS: In eight human mandibles obtained postmortem, bone mineral density (BMD) was measured with dental quantitative CT (DQCT) and correlated with insertion torque values at 45 implant sites during insertion of screw-shaped dental implants (Brånemark System MKIII, Nobel Biocare, AB, Göteborg, Sweden). RESULTS: A significant correlation (r=0.86, P<0.001) between BMD and torque values was observed, indicating that local BMD at a specific implant position is related to the supportive capacity of the jawbone. BMD exhibited no correlation with bone height or position. CONCLUSION: The noninvasive assessment of BMD using a DQCT scan employing a low-dose protocol may be used to estimate expected primary stability depending on BMD, implant type and preparation procedure. These data may therefore help the surgeon to select the optimum implant position, implant type and operation technique.

Absorptiometry, Photon↗

Friction and torque govern the relaxation of DNA supercoils by eukaryotic topoisomerase IB.

Topoisomerases relieve the torsional strain in DNA that is built up during replication and transcription. They are vital for cell proliferation and are a target for poisoning by anti-cancer drugs. Type IB topoisomerase (TopIB) forms a protein clamp around the DNA duplex and creates a transient nick that permits removal of supercoils. Using real-time single-molecule observation, we show that TopIB releases supercoils by a swivel mechanism that involves friction between the rotating DNA and the enzyme cavity: that is, the DNA does not freely rotate. Unlike a nicking enzyme, TopIB does not release all the supercoils at once, but it typically does so in multiple steps. The number of supercoils removed per step follows an exponential distribution. The enzyme is found to be torque-sensitive, as the mean number of supercoils per step increases with the torque stored in the DNA. We propose a model for topoisomerization in which the torque drives the DNA rotation over a rugged periodic energy landscape in which the topoisomerase has a small but quantifiable probability to religate the DNA once per turn.

DNA Topoisomerases, Type I↗

Influence of rotational speed, torque and operator's proficiency on ProFile failures.

AIM: The purpose of this study was to evaluate the influence of rotational speed, torque, and operator experience with a specific Ni-Ti rotary instrumentation technique on the incidence of locking, deformation and separation of instruments. METHODOLOGY: ProFile Ni-Ti rotary instruments (PRI) sizes 40-15 with a 6% taper were used in a crown-down technique. In one group of canals (n = 300) speeds of 150, 250 and 350 rpm (subgroups 1, 2 and 3) were used. Each one of the subgroups included 100 canals. In a second group (n = 300) torque was set at 20, 30 and 55 Ncm (subgroups 4, 5 and 6). In the third group (n = 300) three operators with varying experience (subgroups 7, 8 and 9) were also compared. Each subgroup included the use of 10 sets of PRI and 100 canals of extracted human molars. Each set of PRI was used in up to 10 canals and then sterilized before each case. NaOCl 2.5% was used as an irrigant. The number of locked, deformed, and separated instruments for the different groups, and within each part of the study was analysed statistically for significance with chi-squared tests. RESULTS: In group 1 only one instrument was deformed in the 150-rpm group and no instruments separated or locked. In the 250-rpm group instrument separation did not occur, however, a high incidence of locking, deformation and separation was noted in the 350-rpm group. In general, instrument sizes 30-15 locked, deformed and separated. Chi-squared statistics showed a significant difference between the 150 and 350 rpm groups but no difference between the 150 and 250 rpm groups with regard to instrument separation. Overall, there was a trend toward a higher incidence of instrument deformation and separation in smaller instruments. Locking and separation occurred during the final passage of the instruments, in the last (tenth) canal in each subgroup. In the second group, neither separation nor deformation and locking occurred during the use of the ProFile instruments, at 150 rpm, and at the different torque values. In the third group, chi-squared analysis demonstrated that significantly more instruments separated with the least experienced operator. Instrument locking, deformation, and separation did not occur with the most experienced operator. CONCLUSIONS: Preclinical training in the use of the PRI technique with crown-down at 150 rpm were crucial in avoiding instrument separation and reducing the incidence of instrument locking and deformation.

Chi-Square Distribution↗

Failure of ProFile instruments used with high and low torque motors.

AIM: The purpose of this study was to evaluate the failure incidence of ProFile nickel-titanium rotary instruments when used in conjunction with different motors and a specific instrumentation technique. METHODOLOGY: ProFile Ni-Ti rotary instruments (PRI) with 0.06 taper were used in a crown-down technique. In groups 1, 2 and 3, an air, a high torque and a low torque motor were used, respectively. Each group included 30 canals in extracted human molars. One set of PRI sizes 40-15 was used for each canal; they were sterilized before each case. A 2.5% NaOCl solution was used as an irrigant. The number of deformed and separated instruments was recorded for the various experimental groups. RESULTS: Instrument separation did not occur in any of the three groups. One and two instruments were deformed when using the air and high torque motors, respectively. CONCLUSIONS: The results indicated no difference between the three motors with respect to the incidence of instrument failure. The results suggest that the use of PRI in a crown-down manner with air control motors was safe.

Dental High-Speed Equipment↗