Temperature mapping of magnetic resonance-guided laser interstitial thermal therapy (LITT) in lymphangiomas of the head and neck.

BACKGROUND AND OBJECTIVE: Lymphangiomas of the tongue and neck are uncommon benign congenital lymphatic tumors. These vascular lesions are difficult to treat, frequently recur, and can cause patients significant morbidity. Treatment may also be complicated by adjacent vital anatomic structures. Magnetic resonance (MR)-controlled laser-induced interstitial thermotherapy (LITT) has been proven to be a noninvasive safe treatment. Real-time monitoring of tissue temperature with thermosensitive sequences allows controlled coagulation necrosis. STUDY DESIGN/MATERIALS AND METHODS: LITT was performed in a lymphangioma specimen ex vivo. In four patients (eight procedures) with lymphangiomas of the tongue and neck, MR-guided LITT was performed with a percutaneous approach in a multiapplicator technique. The laser system consisted of a titanium catheter and a protective catheter. The dome of the fiber end had a diameter of 1.4 mm with an active length of 20 mm. Temperature sensitive sequences were used in a 0.5 T open-configured MR scanner with the proton frequency shift technique to map the spatial and temporal distribution of Nd:YAG laser effects (7 Watts, 30 pulses per second, 10 minutes/location). Postoperative MR follow-up was performed at 1 week and at 3 months. In three patients, partial resection of the tumor was performed 6 months after LITT. RESULTS: In three patients, MR clearly showed a diminished tumor volume. All four patients reported subjective amelioration and in three patients former functional problems, such as speech and swallowing were improved. MR thermometry allowed accurate demarcation of changes by heat and distinction of affected tumor volume (3.0 cm +/- 0.3 cm). The histology of the patients 6 months after LITT showed laser-induced fibrosis of former lymphatic tissue. CONCLUSION: The results suggest that LITT can be performed safely with tissue preserving of vital structures and can be effective in the treatment of deep tumors, such as lymphangiomas. However, given the nature of the lesion, the potential for recurrence exists no matter what modality is chosen.

Adult↗

Hyperthermia in the treatment of cancer. Perspectives on its promise and its problems.

The potential for the use of hyperthermia in the treatment of cancer is based on a strong and compelling biologic rationale. In the laboratory it has been shown in quantitative assays both in vitro and in vivo that (1) hyperthermia is cytotoxic to tumor cells as a function of time at temperatures above 42 degrees C; (2) cytotoxicity is relatively high for radioresistant S-phase cells and for cells that are nutritionally deprived and acidotic, conditions one might expect in regions of tumors containing large numbers of radioresistant hypoxic cells; and (3) heat is a radiosensitizer and a chemosensitizer. Clinical study is hampered by less than optimal physical heating methods and the need for invasive thermometry. Ultrasonic and electromagnetic approaches each have limitations and advantages. In spite of technical limitations, efficacy has been shown for superficial tumor sites treated by local hyperthermia and Phase I studies are underway investigating the more complicated problem of deep regional hyperthermia. Although whole body hyperthermia has the attractive capability of treating metastatic as well as more localized cancer, it is toxic therapy and its role in treatment remains undefined. Research advances in equipment design and treatment optimization are needed; however, there are studies underway utilizing existing methods and rationale which should further clarify the potential clinical usefulness of regional hyperthermia in combined modality approaches to cancer therapy.

Animals↗

Hyperthermia alone in the treatment of recurrences of malignant tumors. Experience with 60 lesions.

Localized hyperthermia alone has been used for the treatment of cancer recurrences in which previous conventional therapies have failed. Since 1983 and 1988, 57 patients with 60 lesions have been heated by means of a microwave and radiofrequency system. Treatment protocol provided 45 minutes of heating at the intratumor temperature of at least 42 degrees C, twice a week, for a total number of six, eight, or ten heating sessions. Invasive intratumor thermometry was performed for all lesions. Complete response (CR) was obtained in ten cases (16.6%) and partial response (PR) in 14 (23.4%). Higher rates of CR were observed in the chest wall (38.5%) compared with the head and neck area (11.4%), trunk (10%), and limbs (none). Adenocarcinoma was the most responsive histologic type (40%). Squamous cells carcinoma had 7.7% CR. The only case of undifferentiated carcinoma showed CR; there were none on five sarcomas. Long-term local control (24 months) was approximately 7%. The multivariate analysis showed the statistical significance of the histologic variety (adenocarcinoma versus others, P less than 0.0001). Side effects and complications of the treatment were minimal.

Adult↗

Prosthetic heart valves: evaluation of magnetic field interactions, heating, and artifacts at 1.5 T.

The purpose of this study was to use ex vivo testing techniques to determine the magnetic resonance imaging (MRI) safety aspects for 32 different heart valve prostheses that had not been evaluated previously in association with the 1.5-T MR environment. Ex vivo testing was performed using previously described techniques for the evaluation of magnetic field interactions (deflection angle and torque), heating [gel-filled phantom and fluoroptic thermometry; 15 minutes of MRI at a specific absorption rate (SAR) of 1.1 W/kg], and artifacts (using gradient echo and T1-weighted spin-echo pulse sequences). Thirteen heart valve prostheses displayed interactions with the magnetic field. However, these magnetic field interactions were considered relatively minor. Heating was < or =0.8 degrees C for these implants. Artifacts varied from mild to severe depending on the amount and type of metal used to make the particular heart valve prosthesis. For these 32 different heart valve prostheses, the relative lack of substantial magnetic field interactions and negligible heating indicate that MR procedures may be conducted safely in individuals with these implants using MR systems with static magnetic fields of 1.5 T or less.

Artifacts↗

Magnetic resonance temperature imaging for guidance of thermotherapy.

Continuous thermometry during a hyperthermic procedure may help to correct for local differences in heat conduction and energy absorption, and thus allow optimization of the thermal therapy. Noninvasive, three-dimensional mapping of temperature changes is feasible with magnetic resonance (MR) and may be based on the relaxation time T(1), the diffusion coefficient (D), or proton resonance frequency (PRF) of tissue water. The use of temperature-sensitive contrast agents and proton spectroscopic imaging can provide absolute temperature measurements. The principles and performance of these methods are reviewed in this paper. The excellent linearity and near-independence with respect to tissue type, together with good temperature sensitivity, make PRF-based temperature MRI the preferred choice for many applications at mid to high field strength (>/= 1 T). The PRF methods employ radiofrequency spoiled gradient-echo imaging methods. A standard deviation of less than 1 degrees C, for a temporal resolution below 1 second and a spatial resolution of about 2 mm, is feasible for a single slice for immobile tissues. Corrections should be made for temperature-induced susceptibility effects in the PRF method. If spin-echo methods are preferred, for example when field homogeneity is poor due to small ferromagnetic parts in the needle, the D- and T(1)-based methods may give better results. The sensitivity of the D method is higher that that of the T(1) methods provided that motion artifacts are avoided and the trace of D is evaluated. Fat suppression is necessary for most tissues when T(1), D, or PRF methods are employed. The latter three methods require excellent registration to correct for displacements between scans.

Animals↗

Joule heating in packed capillaries used in capillary electrochromatography.

Effective heat dissipation is critical for reproducible and efficient separations in electrically driven separation systems. Flow rate, retention kinetics, and analyte diffusion rates are some of the characteristics that are affected by variation in the temperature of the mobile phase inside the column. In this study, we examine the issue of Joule heating in packed capillary columns used in capillary electrochromatography (CEC). As almost all commonly used CEC packings are poor thermal conductors, it is assumed that the packing particles do not conduct heat and heat transfer is solely through the mobile phase flowing through the system. The electrical conductivity of various mobile phases was measured at different temperatures by a conductivity meter and the temperature coefficient for each mobile phase was calculated. This was followed by measurement of the electrical current at several applied voltages to calculate the conductivity of the solution within the column as a function of the applied voltage. An overall increase in the conductivity is attributed to Joule heating within the column, while a constant conductivity means good heat dissipation. A plot of conductivity versus applied voltage was used as the indicator of poor heat dissipation. Using theories that have been proposed earlier for modeling of Joule heating effects in capillary electrophoresis (CE), we estimated the temperature within CEC columns. Under mobile and stationary phase conditions typically used in CEC, heat dissipation was found to be not always efficient. Elevated temperatures within the columns in excess of 23 degrees C above ambient temperature were calculated for packed columns, and about 35 degrees C for an open column, under a given set of conditions. The results agree with recently published experimental findings with nuclear magnetic resonance (NMR) thermometry, and Raman spectroscopic measurements.

Buffers↗

Active microwave tomographic imaging of isolated, perfused animal organs.

The relative transparency of biological materials to high-frequency electromagnetic waves has encouraged the development of new systems for imaging. This report describes experiments of microwave tomography conducted on a prototype. The object to be analyzed is submerged in water and is illuminated by a plane wave. The total electric field is analyzed by a microwave camera. The recorded data are then processed numerically in order to reconstruct the image that corresponds to the distribution of equivalent currents in a defined plane of a section. Experiments have been conducted on isolated kidneys with and without perfusion. The influence of the perfusing solution temperature has also been studied. These experiments show the potential of this system, especially through the correlation between microwave images and the biological structures. They also confirm previous results concerning spatial resolution and depth of exploration. Finally, the results demonstrate the influence of temperature and support the applicability of this imaging system in non-invasive thermometry, especially for clinical hyperthermia.

Animals↗

Comparative study of shortwave heating patterns in phantoms with polyethylene and silk partitions.

Specific absorption rate (SAR) and effective depths of heating patterns induced by a shortwave, pancake diathermy applicator in fat-muscle phantom are measured. Midplane partitions of polyethylene and silk screen with and without contact chemicals are used. Thermographically obtained SAR data show nearly the same value for silk-screen partitions with and without contact chemicals and slightly lower values with polyethylene partitions, provided that the partition midplanes are tightly pressed against each other. Thermometry data indicate that for low-power exposures the major error in thermographic measurements obtained after termination of heating is due to thermal diffusion and not evaporative cooling in the opened midplane of the phantom.

Diathermy↗

Assessment of Joule heating and its effects on electroosmotic flow and electrophoretic transport of solutes in microfluidic channels.

Joule heating is inevitable when an electric field is applied across a conducting medium. It would impose limitations on the performance of electrokinetic microfluidic devices. This article presents a 3-D mathematical model for Joule heating and its effects on the EOF and electrophoretic transport of solutes in microfluidic channels. The governing equations were numerically solved using the finite-volume method. Experiments were carried out to investigate the Joule heating associated phenomena and to verify the numerical models. A rhodamine B-based thermometry technique was employed to measure the solution temperature distributions in microfluidic channels. The microparticle image velocimetry technique was used to measure the velocity profiles of EOF under the influence of Joule heating. The numerical solutions were compared with experimental results, and reasonable agreement was found. It is found that with the presence of Joule heating, the EOF velocity deviates from its normal "plug-like" profile. The numerical simulations show that Joule heating not only accelerates the sample transport but also distorts the shape of the sample band.

Electrophoresis↗

Neurostimulation systems for deep brain stimulation: in vitro evaluation of magnetic resonance imaging-related heating at 1.5 tesla.

PURPOSE: To assess magnetic resonance imaging (MRI)-related heating for a neurostimulation system (Activa Tremor Control System, Medtronic, Minneapolis, MN) used for chronic deep brain stimulation (DBS). MATERIALS AND METHODS: Different configurations were evaluated for bilateral neurostimulators (Soletra Model 7426), extensions, and leads to assess worst-case and clinically relevant positioning scenarios. In vitro testing was performed using a 1.5-T/64-MHz MR system and a gel-filled phantom designed to approximate the head and upper torso of a human subject. MRI was conducted using the transmit/receive body and transmit/receive head radio frequency (RF) coils. Various levels of RF energy were applied with the transmit/receive body (whole-body averaged specific absorption rate (SAR); range, 0.98-3.90 W/kg) and transmit/receive head (whole-body averaged SAR; range, 0.07-0.24 W/kg) coils. A fluoroptic thermometry system was used to record temperatures at multiple locations before (1 minute) and during (15 minutes) MRI. RESULTS: Using the body RF coil, the highest temperature changes ranged from 2.5 degrees-25.3 degrees C. Using the head RF coil, the highest temperature changes ranged from 2.3 degrees-7.1 degrees C.Thus, these findings indicated that substantial heating occurs under certain conditions, while others produce relatively minor, physiologically inconsequential temperature increases. CONCLUSION: The temperature increases were dependent on the type of RF coil, level of SAR used, and how the lead wires were positioned. Notably, the use of clinically relevant positioning techniques for the neurostimulation system and low SARs commonly used for imaging the brain generated little heating. Based on this information, MR safety guidelines are provided. These observations are restricted to the tested neurostimulation system.

Brain↗

Magnetic resonance safety testing of a newly-developed fiber-optic cardiac pacing lead.

PURPOSE: To assess magnetic resonance (MR) safety for a newly developed, fiber-optic cardiac pacing lead. MATERIALS AND METHODS: MR safety was assessed for the fiber-optic cardiac pacing lead by evaluating magnetic field interactions and heating. Translational attraction and torque were evaluated using a 1.5-Tesla MR system and previously described, standardized techniques. MR imaging-related heating was assessed using a 1.5-Tesla MR system and a transmit/receive, body radiofrequency (RF) coil with the fiber-optic lead positioned to simulate an in vivo condition in a saline-filled phantom. The phantom had dimensions similar to a human subject's torso and head. A fluoroptic thermometry system was used to record temperatures on and near the electrodes of the fiber-optic pacing lead at five-second intervals immediately before and during 20 minutes of MR imaging performed at a whole-body-averaged specific absorption rate (SAR) of 1.5 W/kg. Temperatures were also recorded from a reference site during this experiment. RESULTS: Magnetic field interactions for the fiber-optic lead were minimal (deflection angle, 23 degrees; torque, +2). The highest temperature change recorded for the fiber-optic cardiac pacing lead and reference site was +0.8 degrees C. CONCLUSION: The minor magnetic field interactions and relative lack of heating for the fiber-optic pacing lead indicate that it should be safe for patients with this device to undergo MR imaging procedures using MR systems operating at 1.5-T or less and at a whole-body-averaged SARs up to 1.5 W/kg.

Electrodes↗

8.0-Tesla human MR system: temperature changes associated with radiofrequency-induced heating of a head phantom.

PURPOSE: To investigate if the heat induced in biological tissues by typical radio frequency (RF) energy associated with an 8.0-Tesla magnetic resonance (MR) system causes excessive temperature changes. MATERIALS AND METHODS: Fluoroptic thermometry was used to measure temperatures in multiple positions in a head phantom made of ground turkey breast. A series of experiments were conducted with measurements obtained at RF power levels ranging from a specific absorption rate (SAR) of up to 4.0 W/kg for 10 minutes. RESULTS: The highest temperature increases were up to 0.7 degrees C. An inhomogeneous heating pattern was observed. In general, the deep regions within the phantom registered higher temperature increases compared to the peripheral sites. CONCLUSION: The expectation of an inhomogeneous RF distribution in ultra high field systems (> 4 T) was confirmed. At a frequency of 340 MHz and in-tissue RF wave length of about 10 cm, the RF inhomogeneity was measured to create higher temperatures in deeper regions of a human head phantom compared to peripheral tissues. Our results agree with the computational electromagnetic calculations for such frequencies. Importantly, these experiments indicated that there were no regions of heating that exceeded the current FDA guidelines.

Head↗

MRI monitoring of the thermal ablation of tissue: effects of long exposure times.

MRI-derived thermometry based on the temperature-dependence of the proton resonant frequency (PRF) is extremely sensitive to changes in tissue unrelated to temperature changes, including tissue swelling. This study investigated the maximum amount of time that this phase-subtraction-based method can be used to accurately monitor temperature changes in vivo. Long-duration focused ultrasound sonications were delivered in rabbit thigh muscle with a phased-array transducer, and the time that tissue swelling began was monitored. Tissue swelling began to occur at about one minute. The temperature correlated well with an implanted thermocouple up to this time. After this time, severe artifacts in the phase-difference maps were observed. The thermal dose model predicted the extent of tissue damage well for subsequent one minute sonications. These results will have implications for MRI guidance of thermal therapies with long exposure times.

Animals↗

Laser-induced interstitial thermotherapy of liver metastases in an interventional 0.5 Tesla MRI system: technique and first clinical experiences.

Laser-induced interstitial thermotherapy (LITT) surveyed by magnetic resonance imaging (MRI) has been shown to be effective in various applications. The laser treatment of colorectal liver metastases usually requires a separate device (e.g., ultrasound or CT) to position the laser applicator. In this study, we used an interventional 0.5 T MRI system, allowing both the navigation to the target tissue and on-line thermometry. Laser irradiation was performed using a near-infrared laser source combined with a cooled laser light guide. We treated 20 patients exhibiting a total of 58 colorectal liver metastases. Clinically relevant complications did not occur. No residual tumor was observed after laser irradiation in all metastases with a diameter below 2 cm. Metastases with a mean diameter between 2 and 3 cm demonstrated total necrosis in 71%, while in larger tumors this proportion decreased to 46% (diameter, 3-4 cm) and 30% (diameter, >4 cm), respectively. We conclude that LITT, guided by the employed interventional MRI system, is feasible and safe. The results suggest a more aggressive treatment, especially for larger metastases. J. Magn. Reson. Imaging 2001;13:729-737.

Aged↗

Metallic neurosurgical implants: evaluation of magnetic field interactions, heating, and artifacts at 1.5-Tesla.

The purpose of this study was to use ex vivo testing to determine the magnetic resonance imaging (MRI) safety aspects for seven different metallic neurosurgical implants in association with the 1.5-T MR environment. Ex vivo testing was performed using previously-described techniques for the evaluation of magnetic field interactions (deflection angle and torque), heating (gel-filled phantom and fluoroptic thermometry; 15 minutes of MRI at a specific absorption rate [SAR] of 1.4 W/kg), and artifacts (using T1-weighted, spin-echo and gradient-echo pulse sequences). None of the metallic implants displayed interactions with the magnetic field. The highest temperature change was +0.6 degrees C for the representative implant that was evaluated. Artifacts were relatively minor. The lack of magnetic field interactions and negligible heating indicate that MR procedures may be conducted safely in patients with these neurosurgical implants using MR systems with static magnetic fields of 1.5-T or less. Furthermore, these implants may be considered for use in interventional MR procedures insofar as the MR safe qualities and relatively small artifacts would likely be desirable for such procedures.

Artifacts↗

Preliminary clinical experience with laser-induced interstitial thermotherapy in patients with hepatocellular carcinoma.

The purpose of this preliminary study was to evaluate whether laser-induced interstitial thermotherapy (LITT) may be used for palliative treatment of localized hepatocellular carcinomas (HCC). We applied LITT to two patients suffering from unresectable localized hepatocellular carcinomas of different sizes (2.5 and 4 cm). LITT was performed with an Nd:YAG laser (1,064 nm) at 5 W laser power (15-20 minutes). Thermometry during LITT was performed by MRI using a temperature-sensitive T1-weighted fast low-angle shot (FLASH) sequence. Follow-up for local tumor control was performed by MRI and ultrasound. LITT was well tolerated and no adverse events occurred during or after LITT; no secondary liver lesions were seen in the follow-up (11 or 12 months, respectively). Only minimal tumor growth was observed in the larger HCC (from 4 to 5 cm), whereas the smaller HCC remained unchanged in size during 11 months of follow-up. We conclude that LITT might be an effective minimally invasive palliative treatment option for patients with small unresectable HCC.

Aged↗

Single-shot diffusion-weighted RARE sequence: application for temperature monitoring during hyperthermia session.

A diffusion-sensitive single-shot RARE (rapid acquisition with relaxation enhancement) sequence was implemented on a 2T whole-body MRI system. The sequence was optimized for diffusion-based MR thermometry, both on a conventional whole-body gradient system and on a high-performance gradient insert. The use of spin-echo versus stimulated-echo diffusion weighting is discussed as a function of gradient performance. Diffusion-based temperature mapping was used to observe the effect of the geometry of the antenna used for radiofrequency (RF) hyperthermia on the temperature distribution. Temperature changes of +/-.5 degrees C in gel and +/-2 degrees C in a muscle sample in vitro could be detected within 16 seconds (gel) or 1 minute (muscle) at a spatial resolution of 2 x 2 x 8 mm. Temperature changes in vivo were also observed on human muscle cooled with ice with comparable sensitivity for the measured apparent diffusion coefficient (ADC) values.

Animals↗

Evaluation of specific absorption rate as a dosimeter of MRI-related implant heating.

PURPOSE: To compare the magnetic resonance imaging (MRI)-related heating per unit of whole body averaged specific absorption rate (SAR) of a conductive implant exposed to two different 1.5-Tesla/64 MHz MR systems. MATERIALS AND METHODS: Temperature changes at the electrode contacts of a deep brain stimulation lead were measured using fluoroptic thermometry. The leads were placed in a typical surgical implant configuration within a gel-filled phantom of the human head and torso. MRI was performed using two different transmit/receive body coils on two different generation 1.5-Tesla MR systems from the same manufacturer. Temperature changes were normalized to whole body averaged SAR values and compared between the two scanners. RESULTS: Depending on the landmark location, the normalized temperature change for the implant was significantly higher on one MR system compared to the other (P < 0.001). CONCLUSION: The findings revealed marked differences across two MR systems in the level of radiofrequency (RF)-induced temperature changes per unit of whole body SAR for a conductive implant. Thus, these data suggest that using SAR to guide MR safety recommendations for neurostimulation systems or other similar implants across different MR systems is unreliable and, therefore, potentially dangerous. Better, more universal, measures are required in order to ensure patient safety.

Body Temperature↗