Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “TOOTH, ARTIFICIAL”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38Linked to original sources

Combination fixed and removable prostheses using a CoCr alloy: a clinical report.

It is now possible to provide combination fixed/removable prosthetic restorations using only 1 dental alloy, such as CoCr, a nonprecious alloy. This alloy offers clinical performance and demonstrated corrosion resistance. This clinical report demonstrates use of a single CoCr alloy for metal-ceramic fixed partial dentures in conjunction with a mandibular removable partial denture.

Adult↗

Tissue healing under provisional restorations with ovate pontics: a pilot human histological study.

STATEMENT OF PROBLEM: Ovate pontics mimic the natural tooth contour and provide an esthetic result however, few studies have evaluated the histological changes in underlying tissues. PURPOSE: The purpose of this pilot study was to histologically evaluate the healing of gingival tissues in contact with provisional ovate pontics after 2 weeks. MATERIAL AND METHODS: Three patients requiring fixed partial dentures participated in this study. The provisional restorations consisted of a fixed partial denture having 2 ovate pontics: one in acrylic resin (Jet), with an ovate shell made of low-fusing ceramic (Duceram LFC); the other made completely of the same acrylic resin (control). After 2 weeks, biopsies of the gingival tissues beneath the pontics were retrieved for histological examination, and immunohistochemistry for evaluation of the vascular endothelial growth factor (VEGF) was performed. Data were analyzed using descriptive statistics. RESULTS: Clinically, all of the ovate pontic-prepared sites showed partial healing. Histologically, the thickness of the entire mucosa was similar in both specimens; however, in some regions, the epithelium presented ulcerations that were generally deeper and more frequent in control sites than in test sites. Immunohistochemical results showed that tissues beneath LFC pontics seemed to be less inflamed since they demonstrated a lower expression of VEGF (10.7 +/- .8) compared to those beneath acrylic resin ovate pontics (33.9 +/- 2.5). CONCLUSION: This pilot study demonstrated that the placement of provisional LFC ovate pontics may be advantageous for the reparative processes of the underlying tissues.

Acrylic Resins↗

Fabrication of a duplicate denture using visible light-polymerized resin as an interim denture base.

This article describes a technique for producing a duplicate denture using a visible light-polymerized (VLP) denture base for support prior to processing. A 2-part mold of the original denture was made, and then a sheet of VLP resin was reduced to a thickness of 0.5 mm and adapted to the fitting surface of the mold to create a denture base. The base was polymerized and the remaining features, such as the teeth and polished surfaces of the denture, were reproduced in wax. This technique may be helpful when performing subsequent clinical and laboratory procedures.

Acrylic Resins↗

Structure and in vitro cytocompatibility of the gastropod shell of Helix pomatia.

Distinguishing features of biological constructions are high stability and adaptation to their environment. Beside biocompatibility, nontoxicity and degradability these characteristics are demanded for new biomaterials in the field of tissue engineering. This study investigated the chemical composition, the organization and the in vitro osteoconductive potential of the terrestrial gastropod shell (Helix pomatia) on CAL72 and human osteoblast-like cells. Chemical composition of the biomaterial was examined by X-ray diffraction (XRD) and scanning electron microscopy (SEM) was performed to analyze the architecture of the snail shell and the morphology of the seeded cells. A double staining procedure (FDA/PI) and a proliferation test (EZ4U) assessed the viability of the cells. Microscopical images showed the multilayered architecture of the aragonite shell with hexagonal crystals on the inner side. The cells spread well on the biomaterial and the highest proliferation rate could be measured with CAL72 cells on the inner shell surface. The osteoconductive effects of this natural biomaterial could encourage further experiments in the field of tissue engineering.

Animals↗

A reliable method for securing anterior denture teeth in denture bases.

STATEMENT OF PROBLEM: Bond failures continue to occur between resin denture teeth and the denture base. PURPOSE: This qualitative study examined a denture tooth modification to determine whether the joint produced between the denture tooth and the denture base resin was stronger than the materials from which it was composed. MATERIAL AND METHODS: Modified and unmodified resin denture teeth were processed to a denture base and stressed until fracture occurred. The fragments were saved, labeled, examined, and evaluated. RESULTS: The unmodified resin denture teeth, which were displaced from the denture, exhibited no evidence of a bond to the denture base. The modified resin denture teeth fractured before separation could occur. CONCLUSION: Within the limitations of this study, the cingulum ledge lock modification produced a mechanical union of the resin denture teeth tested to the denture base material tested that was stronger than the materials from which the lock was composed.

Acrylic Resins↗

Effect of laboratory procedures and thermocycling on the shear bond strength of resin-metal bonding systems.

STATEMENT OF PROBLEM: During fabrication or repair of removable partial dentures, resin-to-metal or resin-to-denture tooth bonds may be stressed by laboratory procedures. PURPOSE: The purpose of this in vitro study was to evaluate the effect of steam cleaning, boiling, ultrasonic cleaning (laboratory procedures), and thermocycling on shear bond strength of resin bonds to metal and denture teeth. MATERIAL AND METHODS: Resin-metal bonding systems and their specific veneer resins (Rocatec, Sinfony; Rocatec, Visio-Gem, HLC-BOND, Zeta LC and Ducera experimental veneer resin) were tested on a Co-Cr alloy (Wirobond C). The veneer resins were bonded to resin denture teeth. The experimental groups (n=7) were subjected to the following conditions: 24-hour storage of the specimens in air (group I, control group), storage in air and treated with simulated laboratory procedures (2 minutes steam cleaning, 15 minutes ultrasonic cleaning at room temperature, 1 hour boiling in water, group II), storage in air with thermocycling (5000 cycles, 5 degrees to 55 degrees C, group III), storage in air with laboratory procedures followed by thermocycling (group IV), and storage in air with thermocycling followed by laboratory procedures (group V). Shear strength tests (MPa) were performed with a universal testing machine until fracture. After shear bond testing, the failure mode of the resin-metal and resin-denture tooth bonds was assessed. Statistical analysis of the results was carried out with one-way analysis of variance and Bonferroni-Dunn's multiple comparisons post hoc analysis for test groups (alpha=0.05). RESULTS: Except for Ducera/denture tooth specimens (groups III to V: 8.7 +/- 3.4-9.1 +/- 1.7; 10.8 +/- 1.9 MPa control group), the Wirobond C and denture tooth specimens (groups III, IV and V: 1.4 +/- 0.9-11.9 +/- 2.3 MPa), showed significantly lower shear bond strengths than the corresponding control groups (7.5 +/- 2.9-21.0 +/- 3.4 MPa, P<.05). The shear bond strengths of group II of Sinfony/Wirobond C (11.6 +/- 3.3 MPa, P<.0001), Visio-Gem/Wirobond C (7.4 +/- 1.9 MPa, P<0.0001), Ducera/Wirobond C (11.8 +/- 2.9 MPa, P<.0001) and of Zeta/denture tooth (3.9 +/- 1.6 MPa, P=.0005) were significantly decreased by steam, boiling, and ultrasonic procedures compared with the corresponding control groups (21.0 +/- 3.4 MPa; 14.7 +/- 4.0 MPa; 19.1 +/- 2.3 MPa; 7.5 +/- 2.9 MPa, respectively). No significant differences were noted among groups III, IV, and V. Co-Cr specimens subjected to the Rocatec system and bonded with Sinfony and HLC BOND/Zeta specimens showed cohesive failure. Adhesive failure was observed for the experimental veneer resin on the Co-Cr specimens and for all veneer resins on the denture teeth. CONCLUSION: Simulation of laboratory procedures and thermocycling caused a significant drop in shear bond strength of metal-resin and denture tooth-resin bonds for most of the tested veneer resins. Thermocycling before shear testing had the same effect on veneer resin bond strength as the simulated laboratory procedures.

Acrylic Resins↗

Tooth movement during processing of complete dentures and its relation to palatal form.

Tooth movement during processing of acrylic resin complete dentures was investigated in relation to palatal form. Eleven clinical casts were radiographed at four denture-processing stages. Seven points were located across each cast. Radiographs were digitized and the images obtained were processed and analyzed for precise measurement of tooth movement. A palatal form index was developed. With respect to a relationship between tooth movement and palatal form, certain trends were found with varying degree and direction, shedding light on the behavior of base material and the dimensional changes that occurred during processing.

Acrylic Resins↗

Comparison of screw loosening, rotation, and deflection among three implant designs.

A common problem associated with single tooth implant restorations is abutment screw loosening. Manufacturers of implants have attempted to overcome this problem by incorporating antirotational design characteristics into their systems. Micromovement and torque levels required to loosen abutment screws for straight and angled antirotational screw-retained abutment/implant combinations from three different manufacturers were examined in this in vitro investigation. A custom-built machine was used and each sample was subjected to compressive horizontal reciprocal movements over a 25-degree incline for a simulated 1-month period. Data were generated that showed movements of the crown/abutment complex during force application. The amount of torque necessary to loosen the abutment screws before and after testing was also recorded and compared for each system. The results indicated no significant differences (p < 0.05) among all the straight and angled abutments for the variables studied.

Analysis of Variance↗

Brånemark single tooth implants: a preliminary report of 76 implants.

Seventy-six Brånemark single-tooth implants were inserted over a 6-year period. Two implants (2.63%) were removed during the follow-up period. All other implants received esthetic and functional single tooth crowns placed on a single tooth abutment or a CeraOne abutment. The most common complication observed was abutment screw loosening, which occurred with 12 crowns. However, it was possible to clearly reduce the occurrence of screw loosening by applying a defined torque. Peri-implant parameters were investigated on 56 implants that were in place for more than 1 year. Acceptable implant function was demonstrated with preestablished clinical parameters and radiographs. Despite the submucosal edge of the crown, peri-implant mucositis was not a major problem. The favorable clinical and esthetic results found in the study encourage an increased application of implants for single tooth restorations.

Adolescent↗