Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “PRESBYOPIA”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38Linked to original sources

Will visual discomfort among visual display unit (VDU) users change in development when moving from single vision lenses to specially designed VDU progressive lenses?

PURPOSE: Three types of progressive additions lenses (PAL) specially designed for VDU-work and one single vision lens were compared in a prospective field study. The aim was to investigate if these progressive lenses created a difference in the development of visual discomfort compared to single vision lenses when working on an optimized VDU-workstation. METHODS: The study had a prospective, parallel group design, with four groups of VDU-workers. Approximately 40 subjects in each group, selected after careful task analysis with special attention towards the visual angles and distances to the work tasks. The groups were followed over one year. A questionnaire concerning visual conditions, working conditions, discomfort in different body areas, the status of the subjects' optometric corrections, psychological factors both at work and at home, amount, frequency and duration of VDU-work etc. was filled in before the intervention, after six months and after one year. No other contact was made with the subjects. The VDU-lenses included were Interview (Essilor), Gradal RD (Zeiss) and Technica (American Optical). Pain intensity and duration were assessed on a 100 mm Visual Analogue Scale (VAS) before the intervention, and six and twelve months after the intervention. All subjects were given a complete optometric examination. RESULTS: Only small changes in the development of headache and visual discomfort were registered. However, the subjective evaluation of area of clear vision and overall satisfaction was significantly improved for the Interview and Gradal RD lens (p < 0.05). There were no significant changes for Technica and single vision lenses. CONCLUSION: Lens designs that cover viewing distances from near and out to approximately 2 meters work well compared to lens designs trying to cover greater range of clear vision. When tasks analysis shows that single vision correction may be used, this is still an acceptable solution.

Computer Terminals↗

Correlation analysis of the optics of progressive addition lenses.

PURPOSE: To investigate the relations between selected key optical parameters and the sizes of the clear viewing areas of progressive addition lenses (PALs). METHODS: The optics of 28 PALs (plano with +2.00 D add) currently on the market were measured with a Rotlex Class Plus lens analyzer. Horizontal cross sections were analyzed in 1 mm vertical steps with respect to the fitting cross. Distance, intermediate, and near viewing zone widths and areas were calculated from the measurements. The maximum amount of unwanted astigmatism, minimum zone width (0.50 DC limit), and maximum power rate in the corridor were also recorded for each lens. Correlation coefficients were determined for all relations. RESULTS: Each of the three viewing zone areas had a significant negative relation with the other (r of -0.4 to -0.8), indicating design tradeoff. Maximum power rate was significantly related to minimum zone width (r = -0.695), which was significantly related to maximum astigmatism (r = -0.616), but there was not a significant relation between maximum power rate and maximum astigmatism. Higher power rates and narrower minimum zones were significantly related to smaller intermediate and larger near zones (r = 0.4 to 0.9). Maximum astigmatism was related to distance zone width (r = 0.42) and to intermediate zone size (r = -0.4 to -0.56), but not significantly related to near viewing zone. Power rate and astigmatism each vary relatively uniformly across each lens. CONCLUSIONS: The fundamental relation appears to be between power rate and zone width, each of which is highly related to sizes of the intermediate and near viewing zones. The maximum amount of astigmatism is related to zone width, but not to maximum power rate. The amount of astigmatism is unrelated to the size of the near zone. The pattern of correlations between the optical and viewing zone parameters help identify the underlying optical relations of PALs.

Eyeglasses↗

Progressive powered lenses: the Minkwitz theorem.

PURPOSE: The Minkwitz theorem, which can be proven to apply to the immediate surface surrounding a line of umbilics, states that astigmatism perpendicular to the line changes twice as quickly as the rate of change of power along the line. Our objective is to test how the Minkwitz theorem applies to the design of progressive addition lenses (PALs). METHOD: Our primary investigation of the astigmatism/power rate relationship used Hoya Tact lenses because they have a relatively large central region with horizontal spherical equivalent power contours and vertical astigmatism power contours. Other PALs were used for subsequent analysis. Lenses were measured with a Rotlex Class Plus lens analyzer. RESULTS: Zone widths in the central region of the Tact lenses exceeded those predicted by the Minkwitz theorem. Above and below this region, zone widths were narrower than predicted. When averaged along the entire corridor, zone widths approximated the Minkwitz theorem. For other PALs, the measured zone widths exceed Minkwitz theorem in the top (distance) and middle (intermediate) corridor but fell short in the lower (near) corridor. Likewise, on average along the entire corridor, they approximate the Minkwitz theorem. CONCLUSIONS: Although the Minkwitz theorem must apply exactly to the immediate locale of an umbilic, deviations from Minkwitz can occur within 2 mm of the corridor. Several factors enable enough local deviation from the Minkwitz theorem to "steer" the astigmatism and affect its magnitude in the peripheral portions of a lens. Although the Minkwitz relationship may be altered in some regions of the corridor, there is a global component to the Minkwitz prediction that applies to PALs. On a global level, the gains and losses of astigmatism along the corridor with respect to the Minkwitz prediction have strong tendency to cancel one another. In the end, it appears the unwanted astigmatism associated with a given power change along a given distance can be redistributed but probably not reduced.

Astigmatism↗

Investigation of the performance of the Menifocal Z gas-permeable bifocal contact lens during continuous wear.

PURPOSE: The Menifocal Z is an alternating vision, concentric, bifocal gas-permeable (GP) contact lens; center distance is connected to near periphery by a smooth transition zone. The lens is produced using tisilfocon A (Menicon Z material), which is approved for up to 30 days of continuous wear (CW). The aim of this study was to evaluate the clinical performance of the Menifocal Z when worn for up to 30 days of CW for 6 months. METHODS: Thirty-five existing GP lens wearers were enrolled in the study. Subjects were fitted with Menifocal Z lenses and follow-up visits were conducted after 2 weeks of daily wear and 1 day, 1 week, 6 weeks, 3 and 6 months of CW. A range of objective and subjective clinical performance measures were assessed, including distance and near visual acuity, the physiological response to CW, and subjective evaluation of vision and comfort. RESULTS: Twenty-seven subjects (77%) completed the study and eight (23%) discontinued: five (14%) as a result of lens-related problems (four vision, one comfort) and three (9%) as a result of non-lens related reasons. Average CW time achieved by the subjects was 22 +/- 2 days. Mean binocular logarithm of the minimum angle of resolution (logMAR) acuities at 6 months were: high contrast distance 0.03 (20/20-), low contrast distance 0.63 (20/80-), and high contrast near 0.26 (20/25, N4). Adverse responses and lens binding were minimal, and there were no significant increases in corneal staining, corneal vascularization, or superior palpebral conjunctival papillae over time (p > 0.05). Problems with night vision (distance and near) with the lenses were the most common difficulties reported by the subjects. CONCLUSIONS: The Menifocal Z appears to be a promising option for presbyopic vision correction, providing successful correction of distance and near vision in a group of experienced GP lens wearers. The hyper Dk tisilfocon A (Menicon Z) material allowed for safe wear of the lenses on a CW basis.

Adult↗

Visual performance of subjects wearing presbyopic contact lenses.

PURPOSE: The purpose of this study is to assess the visual performance of subjects wearing gas-permeable (GP) multifocal contact lenses, soft bifocal contact lenses, GP monovision lenses and spectacles. METHODS: The study included 32 subjects between the ages of 42 and 65 years wearing GP monovision, the Acuvue Bifocal (Vistakon), the Essentials GP Multifocal (Blanchard), and progressive addition lenses (PAL; spectacles group). There were eight subjects in each of these groups who were already wearing these modalities. Binocular low (18%) and high (95%) contrast acuities were recorded using the Bailey-Lovie chart; binocular contrast sensitivity from 1.5 to 18 cycles per degree (cpd) measured with the Vistech VCTS 6500 system, and monocular glare sensitivity at three luminance settings (400, 100, and 12 foot lamberts) was measured using the brightness acuity tester (BAT). Binocular near visual task performance (a modified version of letter counting method used in previous presbyopic studies) was also assessed. RESULTS: For the contact lens-wearing groups, subjects wearing GP multifocals provided the best binocular high and low contrast acuity followed by soft bifocal wearers. There was relative parity between the binocular high and low contrast acuity with PAL and GP multifocal wearers. Monovision acuity, measured binocularly, was determined to be lower than the other three groups with this difference being most significant with high contrast acuity. Among contact lens-wearing groups, it was observed that GP multifocal lens wearers experienced the lowest amount of monocular disability glare followed by soft bifocal wearers and monovision wearers. Subjects wearing soft bifocal lenses and monovision demonstrated slightly reduced binocular contrast sensitivity at all spatial frequencies. In the contact lens groups, GP multifocal lens wearers had the highest binocular contrast sensitivity at all spatial frequencies, on parity with PAL wearers, except at the highest spatial frequency (18 cpd) at which PAL wearers had better vision. Error scores for the binocular near visual task performance between the four groups revealed subjects with GP multifocal lenses and PAL wearers to have the least errors, followed by monovision users and then soft bifocal wearers with the most errors. CONCLUSION: Subjects wearing GP multifocals, soft bifocals, monovision, and PAL spectacles have good binocular contrast sensitivity, satisfactory binocular low and high contrast acuity, and increased sensitivity to glare. Presbyopic subjects requiring the use of contact lenses under dim light levels could benefit from GP multifocal lenses. Contrast and glare sensitivity evaluations provide significant information regarding the visual performance of the presbyopic contact lenses and should be included in regular presbyopic contact lens fitting.

Adult↗

Four different types of client attitudes towards purchasing spectacles in optometric practice.

BACKGROUND: Unmet expectations are a major cause of client dissatisfaction, yet very little is known about the expectations and health values that clients in optometry practice hold about having an eye examination and purchasing spectacles. This study identified different attitudes and behaviours held by presbyope clients in optometric practices. METHOD: A total of 158 presbyope clients, recruited from 14 practices, completed a questionnaire which was developed from the theory of planned behaviour. The questionnaire examined attitudes towards spectacles and visiting the optician, motivation to visit the optician, perceptions of barriers to attending the opticians, information requirements, and preferences for shared decision-making. Responses were analysed using principal components analysis. RESULTS AND CONCLUSIONS: Four factors were identified, which were labelled style, vision, avoiding and seeking. Style is concerned with the importance of appearing fashionable or stylish, and desiring approval from others. Vision relates to clients' attitudes towards obtaining clear vision and to maintaining healthy eyesight. Avoiding describes the perceived difficulties associated with visiting the optician and purchasing new spectacles. Seeking corresponds to the desire for information on the technical details of lenses. Practitioners could use these characteristics to tailor information to meet the needs and address the expectations of individual clients. This may make the information provided more personally relevant, and could enhance client satisfaction.

Adult↗

Binocular vision, age and symptoms.

Changes with age in heterophoria, associated heterophoria, fixation disparity and stereopsis for near vision were investigated in a sample of 187 subjects (age range from 10 to 65 years) divided into six age groups. With increasing age, heterophoria, associated heterophoria and fixation disparity increased in the exo-direction. No change in stereopsis was found. A comparison with visual symptoms for near vision indicated a relationship between symptoms and the magnitude of fixation disparity and associated heterophoria for all age groups, but no relationship was found between the presence of symptoms and heterophoria measurement. No relationship between the presence of symptoms and the central slope of the forced vergence fixation disparity curve was found. These findings suggested that neither the measurement of heterophoria nor the forced vergence disparity curve are appropriate tests in the assessment of binocular vision anomalies. However, fixation disparity and associated heterophoria are related to binocular problems for near vision in all age groups.

Adolescent↗

Criteria for decompensation in binocular vision.

Two groups of patients, one under 40 years of age and the other 40 years and over, were divided into subgroups according to whether they had symptoms associated with near vision. A method developed in 'signal detection theory' was used to determine whether a value could be found for heterophoria, or associated heterophoria, which would predict which patients had symptoms due to decompensated heterophoria in normal routine investigation. Receiver operator characteristic curves (ROC curves) were constructed to look for these cut-off values between patients with, and without, symptoms. No value for dissociated heterophoria was found that would discriminate between the symptomatic and asymptomatic patients. It is concluded that heterophoria measurement is not useful as a routine procedure. In the case of associated heterophoria, for the under 40 years age group, patients with a value of 1 prism dioptre or more are more likely to have symptoms than not, and one-third of patients with close work problems have a value of 2 prism dioptres or more. It was rare to find any asymptomatic patient with a value as high as this. In the 40 years and over age group those with an associated heterophoria of 2 prism dioptres or more are more likely to have symptoms than not. One-third of patients in the latter age group, with symptoms, have a value of 3 prism dioptres or more whilst it is rare to find an asymptomatic patient with a value as large as this.

Adult↗

Analysis of a progressive addition lens population.

Analysis of 98 progressive addition lens (PAL) wearers was undertaken using both mailed questionnaires and by assessing patient records. Statistical analysis was undertaken to investigate the nature and dependent variables of a PAL population. The PAL patients were from the Aston University undergraduate optometric clinic. Social survey techniques, such as the use of personalized mail, first-class stamps, and follow-up letters, were employed to produce a high return rate for the questionnaire. The number of returned questionnaires reached 89.9% of those originally sent which may be considered to be highly representative. The clinical survey showed the success rate for the undergraduate clinic to be either 85.7% or 80.6% depending upon the criterion for successful wear.

Adaptation, Psychological↗

Relation between injected volume and optical parameters in refilled isolated porcine lenses.

PURPOSE: This study was performed to elucidate the correlation between added lens refill material and enhanced lens power as well as the correlation between lens refilling volume and accommodative amplitude as determined by equatorial stretching of ex vivo refilled pigs' lenses. METHODS: Nine porcine lenses were refilled with increasing amounts of silicone oil. After each refill step, the lens power, the lens power change, and the lens thickness were measured both in the relaxed state and with a 3-mm larger ciliary body diameter. In addition, the spherical aberration of the refilled lenses was also quantified. RESULTS: Injection of 0.04 mL silicone material into the relaxed lens enhanced the lens power by 1 D. A 0.54-mm increase of the lens thickness in relaxed lenses added 1 D to the lens power. Increasing the lens refilling volume decreased the lens power changes measured at 3-mm ciliary body stretch. Spherical aberration was positive in the refilled lenses and increased with increasing lens refilling volume. CONCLUSION: The correlation found between the refilling volume and the lens power (0.04 mL D(-1)), as well as the correlation between the lens thickness and the lens power (0.54 mm D(-1)), might be important factors to be controlled in conjunction with surgery, as these also determine the lens power in the presence of this refill material. An increasing lens filling volume is associated with decreasing accommodative amplitude. The positive spherical aberration of refilled porcine lenses presents a sharp contrast to the negative aberration of natural pigs' lenses. Different lens contours and the transition from a gradient to a homogeneous refractive index might be responsible for this change in spherical aberration.

Accommodation, Ocular↗

Characteristics of pupil responses during far-to-near and near-to-far accommodation.

The static and dynamic aspects of the pupil response associated with various amplitudes of far-to-near (accommodation) and near-to-far (disaccommodation) focusing responses were evaluated in this study. Dynamic refractive and pupillary changes were measured simultaneously during focusing responses to targets at real distances in 12 young (23-26 years) emmetropic subjects. The targets were presented alternately at far (6 m) and at one of six near positions from 1 D (1 m) to 6 D (16.7 cm) in 1 D steps. The latency, magnitude and peak velocity of pupil changes associated with accommodation and disaccommodation responses were calculated. The latency of refractive changes was shorter than that of pupillary changes. In general, the pupil constricted with accommodation and started dilating while accommodation was still maintained, resulting in reduced pupil dilation with disaccommodation. The magnitude of the pupil response increased linearly with that of accommodation and disaccommodation. The amount of pupil change per dioptre of refractive change was invariant with various amplitudes of refractive change. The peak velocity of pupil constriction was greater than that of pupil dilation for corresponding amplitudes. The pupil response is more closely associated with accommodation than with disaccommodation.

Accommodation, Ocular↗