Scatter reduction in mammography with air gap.

Scatter reduction by air gaps in mammography was investigated. We have experimentally demonstrated that, independently of the imaging geometry, scatter in air-gap mammography can be well described by a virtual source of scatter (VSS) model. This model postulates that scatter radiation originates from a virtual point source of scatter placed on the central axis between the x-ray source and the exit surface of a patient at distance delta and utilizes only two parameters: delta and (S/P)0. The (S/P)0 parameter represents scatter-to-primary ratio without an air gap and delta is the distance from the exit surface of a patient to the virtual source of scatter. We have experimentally determined the analytical form of the two independent parameters of the VSS model; delta exhibits a linear increase proportional to the radiation field size, does not depend on patient thickness, and is in the 10-30 cm range, while (S/P)0 increases with the field size as a power function and is in the 0.4-1.3 range. In the framework of the VSS model the selectivity, the contrast improvement factor, and the signal-to-noise improvement factor were employed to evaluate performance of air-gap mammography systems. We have demonstrated that selectivity of an air gap rapidly deteriorates at some well-defined critical value of scatter fraction that has profound consequences on air-gap performance. Assuming fixed patient exposure, the results shows that, if a contrast limited detection system (such as film/screen mammography) is used, an air gap system can outperform a grid system only if a very large source-to-patient (SPD) distance is utilized, which might be possible with new laser-based x-ray sources. For the noise limited detection systems (such as digital mammography) even a small SPD (70 cm) and a small air-gap (20 cm) system will outperform a grid system.

Air↗

Computer analysis of mammography phantom images (CAMPI): an application to the measurement of microcalcification image quality of directly acquired digital images.

The purpose of this investigation was to apply the recently developed CAMPI (computer analysis of mammography phantom images) method to a Fischer Mammotest Stereotactic Digital Biopsy machine. Another aim was to further elucidate the nature of the empirically introduced CAMPI measures. Images of an American College of Radiology (ACR) accreditation phantom centered on the largest two speck groups were obtained on this machine under a variety of x-ray conditions. An additional measure, alternative SNR (ASNR) is introduced which is complementary to the SNR measure. Analyses of the Mammotest images revealed that the mAs and kVp dependencies of the CAMPI measures could be understood from basic imaging physics principles. It is shown that: (1) the measures reflect the expected linearity of the digital detector and Poisson photon statistics; (2) under automatic exposure control (AEC) conditions the signal (SIG) measure is proportional to subject contrast; and (3) under AEC conditions the noise (NOI) measure is proportional to the square root of the average absorbed photon energy. Correspondence with basic imaging physics principles shows that the measures are significantly free of artifacts. Precision of the CAMPI measures exceeds that of human observers by orders of magnitude. CAMPI measures are expected to be more relevant to clinical mammography than Fourier metrics as the measurements are done on objects of arbitrary shape and size that were designed by the manufacturer to resemble various detection tasks in mammography. It is concluded that CAMPI can perform objective and highly precise evaluations of phantom image quality in mammography. It could be used as a sophisticated quality control tool, as a replacement for the current ACR/MQSA phantom evaluation program, and to evaluate the rapidly evolving digital mammography technology.

Biophysical Phenomena↗

Neglected aspects of false positive findings of mammography in breast cancer screening: analysis of false positive cases from the Stockholm trial.

OBJECTIVES: To examine the implications of false positive results of mammography in terms of the time lag from screening and complete mammography to the point when women with false positive results are declared free of cancer; the extra examinations, biopsies, and check ups required; and the cost of these extra procedures. DESIGN: Review of women with false positive results from the Stockholm mammography screening trial. SETTING: Department of Oncology, South Hospital, Stockholm. SUBJECTS: 352 and 150 women with false positive results of mammography from the first and second screening rounds of the Stockholm trial. MAIN OUTCOME MEASURES: Extra examinations and investigations required and the cost of these procedures. RESULTS: The 352 women from the first screening round made 1112 visits to the physician and had 397 fine needle aspiration biopsies, 187 mammograms, and 90 surgical biopsies before being declared free of cancer. After six months 64% of the women (219/342) were declared cancer free. The 150 women in the second round made 427 visits to the physician and had 145 fine needle aspiration biopsies, 70 mammograms, and 28 surgical biopsies, and after six months 73% (107/147) were declared cancer free. The follow up costs of the false positive screening results were Kr2.54m (250,000 pounds) in the first round and Kr0.85m (84,000 pounds) in the second round. Women under 50 accounted for about 41% of these costs. CONCLUSIONS: The examinations and investigation carried out after false positive mammography --especially in women under 50--and the cost of these procedures are a neglected but substantial problem.

Adult↗

Two view mammography at incident screens: cost effectiveness analysis of policy options.

OBJECTIVE: To determine the cost effectiveness of two view mammography at incident screens. DESIGN: Incremental cost effectiveness analyses recognising differences in current reading policy, based on effectiveness data from an observational study. SETTING: Breast screening programmes in England and Wales. MAIN OUTCOME MEASURES: Health service costs, cancers detected, incremental cost effectiveness ratios per cancer detected, whole time equivalent staff. RESULTS: For programmes currently using one view with some form of double reading, the incremental cost effectiveness ratio of two view mammography at incident screens ranged between 6589 pounds and 6716 pounds, depending on the reading policy. For programmes currently using one view with single reading, two policy options were found to be more efficient than two view single reading: one view with double reading (arbitration; incremental cost effectiveness ratio of 210 pounds) and two view double reading (arbitration). If programmes using one view with single reading changed to double reading (arbitration) and then subsequently to two views double reading (arbitration), additional cancers could be detected with an incremental cost effectiveness ratio of 7983. The implementation cost of two view mammography at incident screens in programmes in England and Wales would be 2.9 million pounds and would require 13.4 whole time equivalent radiologists. CONCLUSIONS: The cost effectiveness of two view mammography at incident screens depends on the film reading policy. A policy of two view mammography at incident screens in England and Wales would be efficient only if programmes using single reading moved to double reading. Given limited resources, priority should be given to introducing double reading in the subset of programmes currently using single reading as this requires fewer additional radiologists and is more cost effective.

Breast Neoplasms↗

US women's attitudes to false positive mammography results and detection of ductal carcinoma in situ: cross sectional survey.

OBJECTIVE: To determine women's attitudes to and knowledge of both false positive mammography results and the detection of ductal carcinoma in situ after screening mammography. DESIGN: Cross sectional survey. SETTING: United States. PARTICIPANTS: 479 women aged 18-97 years who did not report a history of breast cancer. MAIN OUTCOME MEASURES: Attitudes to and knowledge of false positive results and the detection of ductal carcinoma in situ after screening mammography. RESULTS: Women were aware that false positive results do occur. Their median estimate of the false positive rate for 10 years of annual screening was 20% (25th percentile estimate, 10%; 75th percentile estimate, 45%). The women were highly tolerant of false positives: 63% thought that 500 or more false positives per life saved was reasonable and 37% would tolerate 10 000 or more. Women who had had a false positive result (n=76) expressed the same high tolerance: 39% would tolerate 10 000 or more false positives. 62% of women did not want to take false positive results into account when deciding about screening. Only 8% of women thought that mammography could harm a woman without breast cancer, and 94% doubted the possibility of non-progressive breast cancers. Few had heard about ductal carcinoma in situ, a cancer that may not progress, but when informed, 60% of women wanted to take into account the possibility of it being detected when deciding about screening. CONCLUSIONS: Women are aware of false positives and seem to view them as an acceptable consequence of screening mammography. In contrast, most women are unaware that screening can detect cancers that may never progress but feel that such information would be relevant. Education should perhaps focus less on false positives and more on the less familiar outcome of detection of ductal carcinoma in situ.

Adult↗

US women's attitudes to false-positive mammography results and detection of ductal carcinoma in situ: cross-sectional survey.

OBJECTIVE: To determine women's attitudes and knowledge of both false-positive mammography results and the detection of ductal carcinoma in situ after screening mammography. DESIGN: Cross-sectional survey. SETTING: United States. PARTICIPANTS: A total of 479 women aged 18 to 97 years who did not report a history of breast cancer. Main outcome measures Attitudes and knowledge about false-positive results and the detection of ductal carcinoma in situ after screening mammography. RESULTS: Women were aware that false-positive results do occur. Their median estimate of the false-positive rate for 10 years of annual screening was 20% (25th percentile estimate, 10%; 75th percentile estimate, 45%). The women were highly tolerant of false-positive results: 63% thought that 500 or more false-positives per life saved was reasonable, and 37% would tolerate a rate of 10,000 or more. Women who had had a false-positive result (n = 76) expressed the same high tolerance: 30 (39%) would tolerate 10,000 or more false-positives. In all, 62% of women did not want to take false-positive results into account when deciding about screening. Only 8% of women thought that mammography could harm a woman without breast cancer, and 94% doubted the possibility of nonprogressive breast cancers. Few had heard of ductal carcinoma in situ, a cancer that may not progress, but when informed, 60% of women wanted to take into account the possibility of it being detected when deciding about screening. CONCLUSIONS: Women are aware of false-positive results and seem to view them as an acceptable consequence of screening mammography. In contrast, most women are unaware that screening can detect cancers that may never progress but think that such information would be relevant. Education should perhaps focus less on false-positive results and more on the less-familiar outcome of the detection of ductal carcinoma in situ.

Adolescent↗

Surveys on mammography frequency in Geneva.

Two surveys were conducted in Geneva, in 1991 and 1995, to assess the coverage of mammography before the introduction of a breast cancer screening programme. Women who attended for mammographies did so at their own request, or were referred by doctors (more by gynaecologists than general practitioners). In 1995, the total female population was around 200,000, of which the target population for screening (age group 50 to 69) was 46,000 persons. The total number of mammographies observed increased by 23%, with a higher increase for "routine" mammographies (+35%). However, these figures hide certain trends, with a high proportion of educated women performing regular breast investigations. The two year coverage rate for mammography among the 50 to 69 age group is estimated at 38%, which means that about 20,000 women within this target population in Geneva still escape screening.

Adolescent↗

Analysis of cancers missed at screening mammography.

Analysis of 320 cancers found in a screened population between August 1985 and May 1990 revealed 77 cancers that were "missed" at screening mammography. The missed lesions consisted of cancers incorrectly diagnosed after mammography (false-negative results) but visible in retrospect (n = 19); cancers correctly diagnosed after mammography but visible in retrospect on an earlier mammogram (n = 47); and cancers that went undetected by the first of two readers (n = 11). Missed lesions were categorized according to type of miss, reason for the miss, breast density, lesion features, and lesion location. The missed lesion were compared with 121 cancers that were correctly diagnosed at screening mammography. The missed cancers occurred in women with denser breasts (P = .046), were less likely to demonstrate malignant microcalcifications, and were more likely to demonstrate a developing opacity as an indication of cancer (P = .005). An understanding of the characteristics of missed lesions may be a valuable aid in increasing the sensitivity of screening mammography.

Breast Neoplasms↗

Quality-oriented mass mammography screening.

PURPOSE: To demonstrate the ability of a mass mammography screening program to provide consistently high-quality mammography screening, while at the same time sustain a large volume of patients to keep the cost of mammography low. MATERIALS AND METHODS: A public-funded, mass mammography screening program, begun in 1988, is currently being conducted in five Canadian provinces. For the Screening Mammography Program of British Columbia, complete follow-up data are available for the first 57 months of operation. During that time, the program expanded from one center with five radiologist screeners to 14 centers with 30 radiologist screeners. There were 201,937 examinations performed on 128,325 women, 35% of whom were younger than 50 years. RESULTS: There were 802 cancers detected at an overall rate of 6.2 per 1,000 women (2.8 per 1,000 in women younger than 50 years and 8.1 per 1,000 in women older than 50 years). In the women younger than 50 years, 90 (72%) of the cancers were stage 0 or stage I, and the axillary lymph nodes were involved in 14 (11%). In the women 50 years or older, 496 (73%) of the cancers were stage 0 or stage 1, and the axillary lymph nodes were involved in 97 (14%). CONCLUSION: If quality is carefully controlled, the results of a mass screening program can be either maintained or improved. For both age groups, the prognostic characteristics are similar.

Breast Neoplasms↗

Development of a community mammography registry: experience in the breast screening program project.

PURPOSE: To assess the formation, implementation, and operation of a community mammography registry, which is a consolidated database for all mammography and breast biopsy reports within a community. MATERIALS AND METHODS: A registry was created in Lee County, Fla. Mammography interpretation data were provided by 13 facilities and 38 radiologists organized in several private practice groups. RESULTS: The registry contains data on 87,926 mammograms and 3,234 breast biopsies performed between June 1991 and May 1994. The registry calculates individual and group mammography interpretation accuracy measures, such as sensitivity, specificity, positive predictive value, false-positive and false-negative rates, and clinical outcome measures such as sizes and stages of malignant lesions detected. CONCLUSION: The registry allows community radiologists and mammography practices to compare their outcomes with those of their local peers and to published data and encourages focused interventions for quality improvement based on objective experience.

Adult↗

Locally advanced breast carcinoma: accuracy of mammography versus clinical examination in the prediction of residual disease after chemotherapy.

PURPOSE: To determine the mammographic features of locally advanced breast carcinoma treated with neoadjuvant chemotherapy and to evaluate the accuracy of mammography in the prediction of residual carcinoma. MATERIALS AND METHODS: Of 90 women treated with hormonally synchronized cytotoxic therapy before mastectomy or lumpectomy for advanced breast carcinoma, 56 were selected because they had undergone mammography before and after neo-adjuvant therapy. Mammographic and clinical opinion on the presence of residual disease was compared with histologic results. RESULTS: Fifty-four (96%) of 56 women had a complete (n = 34 [61%]) or partial (n = 20 [36%]) clinical response. Thirteen (23%) of 56 women had no residual tumor. Sensitivity of mammography in the prediction of residual carcinoma was greater than that of clinical examination (79% vs 49%), but specificity was lower (77% vs 92%). In 24 women with inflammatory carcinoma, sensitivity of mammography was 78% while that of clinical examination was 39%; specificity was equal (83%). CONCLUSION: Mammography was more sensitive than clinical examination in the prediction of residual carcinoma; it was not accurate enough to obviate surgical biopsy.

Antineoplastic Agents↗

Mobile mammography: results of a national survey.

PURPOSE: to learn about mobile mammography in the United States. MATERIALS AND METHODS: A survey of 82 questions was designed, pilot tested, and sent to mobile mammography facilities. The questions addressed many aspects of mobile programs, including administrative, financial, equipment, personnel, film processing, quality assurance, and communication of results. RESULTS: Of the 367 facilities that were mailed surveys, 159 facilities completed the survey, and 30 (19%) of those had discontinued their mobile programs. Seventy-six of 158 (48%) mobile facilities had performed mobile mammography for 1-5 years, and 69 of 158 (44%) had performed mobile mammography for more than 5 years. Seventy-two of 156 (46%) facilities were hospital-owned, and 25 of 156 (16%) were radiologist-owned. One hundred seven of 159 (67%) mobile facilities performed screening only. One hundred fourteen of 152 (75%) facilities charged +80.00 or less for screening. Mobile facilities averaged 20 examinations per day and served diverse populations. Sixty-seven of 159 (42%) facilities accepted self-referred women. Thirty-one percent of the facilities performed on-board processing. Only 71 of 149 (47%) facilities were financially profitable or breaking even, but 112 of 154 (73%) facilities would undertake a mobile project again. CONCLUSION: Mobile programs provide an opportunity to increase access to screening mammography, but they face many obstacles.

Data Collection↗

The diagnostic efficacy of mammography and palpation in early detection of breast cancer.

The diagnostic efficacy of mammography and physical examination, separately and considered together, are evaluated in 912 cases of breast cancer detected at the Center for Social Diseases of the Florence District, where there is a mass-screening program (110 cases) and a diagnostic service for self-referred women (810 cases). The overall sensitivity of the 2 methods increases with age; the trends of diagnostic efficacies of mammography and palpation according to age are similar, except in the 40-44 year age group, in which physical examination has a lower percentage of false-negative cases. In the screening group, there is a greater proportion of nonpalpable cancers and mammography has a larger diagnostic efficacy except in the 40-44 year age group. These results agree with the better sensitivity of mammography in smaller lesion (TI) and with the larger proportion of noninterpretable mammographies in younger women, because of the density of mammalian glands.

Adult↗

Mammography-related beliefs of older women. A survey of an HMO population.

Although breast cancer risk increases with age, most studies show that mammography use decreases. A 15-minute telephone survey of 548 women health maintenance organization (HMO) members aged 65 to 74 who had not obtained a mammogram within the past year was undertaken to identify sociodemographic factors as well as knowledge, belief, and attitudinal characteristics associated with mammography history. Women who had never had a mammogram were less likely to have received a physician's recommendation and more likely to express negative attitudes about mammography, such as having a mammogram means "looking for trouble" and "makes me nervous." In addition, they expressed doubts about their need to have a mammogram and reported that "other problems" prevented them from having a mammogram. These results suggest that women who have never had a mammogram may require more intensive interventions to encourage them to obtain mammograms. In addition to receiving a mammography recommendation from their physicians, they might benefit from individual or small group educational sessions where negative attitudes about mammography could be explored and modified.

Attitude to Health↗

The adequacy of measurement of short and long-term consequences of false-positive screening mammography.

OBJECTIVES: The aim of this study is to review quantitative studies on women's experiences of consequences of false-positive screening mammography to assess the adequacy of the most frequently used instruments for measuring short-term and long-term psychological consequences. METHODS: Relevant papers reporting quantitative studies on consequences of false-positive screening mammography were identified using MEDLINE, CINAHL, EMBASE and PsycInfo databases. Articles citing development and psychometric properties of the most frequently used measures were also retrieved. Finally, the review focused on studies that had used at least one of the most frequently used measures. RESULTS: Twenty-three relevant studies were identified. The most commonly used measures were the General Health Questionnaire (GHQ), the Hospital Anxiety and Depression Scale (HADS), the Psychological Consequences Questionnaire (PCQ) and the State-Trait Anxiety Inventory (STAI). One or more of these was used in 17 of the 23 studies. CONCLUSIONS: The GHQ, the HADS and the STAI have problems with language, content relevance, and content coverage in studies of false-positive screening mammography. These instruments should not be used to measure psychological consequences of any kind of cancer screening. The PCQ is an adequate questionnaire for measuring short-term consequences, and the PCQ is preferable to other measures because of its higher sensitivity. However, there is little evidence that the PCQ is able to adequately detect all long-term consequences of screening mammography. Given the inadequacy of the measurement instruments used, any current conclusions about the long-term consequences of false-positive results of screening mammography must remain tentative.

Anxiety↗

A comparison of two view and one view mammography in the detection of small invasive cancers: results from the National Health Service breast screening programme.

OBJECTIVE: To examine the effect of using two view mammography in comparison with one view mammography in the detection of small (< 15 mm) invasive cancers. SETTING: Screening programme data from National Health Service breast screening programme (NHSBSP). METHODS: Data were collated from all screening programmes in the United Kingdom on standard "Korner" returns (KC62 forms) for the screening year 1 April 1994 to 31 March 1995. The comparison of invasive cancer detection rates by programmes using one and two view mammography with indirectly age standardised invasive cancer detection rates. RESULTS: Programmes using two views for women attending their prevalent screen (first screen) in the NHSBSP detected 3% more non-invasive/microinvasive cancers, 7% more large invasive cancers (> or = 15 mm), and 42% more small invasive cancers (< 15 mm) than programmes using one view mammography. CONCLUSIONS: The success of the screening programme depends largely on the ability of individual programmes to detect small invasive cancers. The results suggest that the benefit of using two view mammography is largely in the increased detection of these cancers.

Breast Neoplasms↗

Use of two view mammography compared with one view in the detection of small invasive cancers: further results from the National Health Service breast screening programme.

OBJECTIVE: To examine further the effect of using two view mammography in comparison with one view mammography in the detection of small (< 15 mm) invasive cancers for programmes in the National Health Service breast screening programme (NHSBSP). The study is in two parts: first the effect on the small invasive cancer detection rate for programmes that changed from using one view to two views for first (prevalent) screens, and secondly the effect on the small invasive cancer detection rate for programmes that used two views for subsequent (incident) screens compared with programmes that used one view. SETTING: Screening programme data from the NHSBSP. METHODS: Data were collated from all screening programmes in the United Kingdom on standard "Korner" returns (KC62 forms) for the screening years 1 April 1994 to 31 March 1995 and 1 April 1995 to 31 March 1996. The comparison between one and two view mammography was made using indirectly age standardised invasive cancer detection rates. RESULTS: For prevalent (first) screens, programmes changing from one view mammography in 1994/95 to two views in 1995/96 reported a 45% (95% confidence interval (CI) 25% to 68%) increase in the detection of invasive cancers of < 15 mm. In comparison, programmes that were already using two views in 1994/95 showed no change in 1995/96. For incident (subsequent) screens the small number of programmes that have opted to use two views reported 25% (95% CI 1% to 55%) more invasive cancers of < 15mm than programmes using one view in 1995/96, and 42% (95% CI 11% to 81%) more in 1994/95. CONCLUSIONS--These results confirm the benefit of using two view mammography in the detection of small invasive cancers, and provide evidence that this effect is seen in subsequent screens as well as the first screen.

Adult↗

Factors associated with mammography utilization among Jordanian women.

This descriptive study aims at assessing beliefs and identifying factors that contributed to the utilization of mammography among a group of Jordanian women. Champion's Revised Health Belief Model Scales (HBMS) is the conceptual framework of this study. It was translated and adopted as the self-administered questionnaire utilized for the purpose of this study. The convenience sample was drawn from the women who had a mammography at a private radiology screening and diagnostic clinic in Amman over a 3-month period. Bivariate and multivariate analyses of the study variables were conducted. The results unveiled women's older age, hearing or reading about mammography, and receiving information about breast tumors from friends as factors predicting current mammography practice. Variables predictive of past mammography practice were related to the women's family or personal history of breast tumors and information about breast tumors from the media, in addition to information about mammograms from family members.

Adolescent↗