Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Flow Injection Analysis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38Linked to original sources

Gold electrodes from recordable CDs

Gold electrodes are widely used in electrochemistry and electroanalytical chemistry. The notable performance when used in stripping analysis of many ionic species and the extraordinary affinity of thio compounds for its surface make these electrodes very suitable for many applications. This paper reports a simple and novel way to construct gold electrodes (CDtrodes) using recordable CDs as the gold source. The nanometer thickness of the gold layer of recordable disks (50-100 nm) favors the construction of band nanoelectrodes with areas as small as 10(-6) cm2. The plane surface can be easily used for the construction of conventional-sized gold electrodes for batch or flow injection analysis or even to obtain electrodes as large as 100 cm2. The low price of commercial recordable CDs allows a "one way use". The evaluation and applicability of these electrodes in the form of nanoelectrodes, in batch and associated with flow cells, are illustrated in this paper.

Journal Article↗

Determination of inorganic ions using microfluidic devices.

The separation and detection of inorganic ions on microfluidic devices has received little attention since the 'lab-on-a-chip' concept has revolutionised the field of electrokinetically driven analysis. This review presents a summary and discussion of the published literature on inorganic analysis using microfluidic devices and includes sections on electromigration separation methods, namely isotachophoresis (ITP), capillary electrophoresis (CE), and hyphenated ITP-CE, together with a brief account of flow injection analysis. The review concludes with the authors' perspective on future directions for inorganic analysis on microfluidic devices.

Chemistry Techniques, Analytical↗

Development of an FIA system with amperometric detection for determination of bentazone in estuarine waters.

On the basis of its electrochemical behaviour a new flow-injection analysis (FIA) method with amperometric detection has been developed for quantification of the herbicide bentazone (BTZ) in estuarine waters. Standard solutions and samples (200 microL) were injected into a water carrier stream and both pH and ionic strength were automatically adjusted inside the manifold. Optimization of critical FIA conditions indicated that the best analytical results were obtained at an oxidation potential of 1.10 V, pH 4.5, and an overall flow-rate of 2.4 mL min(-1). Analysis of real samples was performed by means of calibration curves over the concentration range 2.5x10(-6) to 5.0x10(-5) mol L(-1), and results were compared with those obtained by use of an independent method (HPLC). The accuracy of the amperometric determinations was ascertained; errors relative to the comparison method were below 4% and sampling rates were approximately 100 samples h(-1). The repeatability of the proposed method was calculated by assessing the relative standard deviation (%) of ten consecutive determinations of one sample; the value obtained was 2.1%.

Benzothiadiazines↗

Metalloprotein separation and analysis by directly coupled size exclusion high-performance liquid chromatography inductively coupled plasma mass spectroscopy.

The feasibility of using directly coupled size exclusion high-performance liquid chromatography inductively coupled plasma mass spectroscopy (HPLC/ICP-MS) for the separation and subsequent elemental analysis of metalloproteins in biological samples has been studied. Data, on up to eight elements, was acquired simultaneously and the reconstructed elemental profiles from the chromatographed samples were quantified by flow injection analysis. Absolute and relative detection limits, reproducibility, operational dynamic range, and linearity of response were initially evaluated by analyzing standards of metallothionein protein of known elemental composition for Cd, Zn, and Cu. There was evidence of displacement of Zn from the protein during chromatography and the substitution of Cu sequestered from the mobile phase. Cd associated with the protein was fully recovered during chromatography. Memory effects, due to protein adsorption to the glassware in the torch box, were minimal and there was no degradation of the resolution of the chromatographed peak during extended transport through the HPLC/ICP-MS interface. The versatility of the technique has been demonstrated by the quantitative multi-element analysis of cytosolic metal-binding proteins separated from the polychaete worm Neanthes arenaceodentata. Fidelity of analysis has been demonstrated by two independent procedures: first, by comparing the elemental profiles obtained by directly aspirating the HPLC eluant into the ICP-MS to those obtained by collecting fractions and quantifying the metal content of the proteins in the conventional analytical mode; second, by comparing the stable isotopic profiles for 114Cd obtained by simultaneous ICP-MS analysis with radiometric profiles of 109Cd obtained by counting radioactivity associated with collected fractions.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

A rotating ball inlet for on-line MALDI mass spectrometry.

The rotating ball inlet (ROBIN) is presented in a new design for on-line matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS). This method uses a capillary to deliver a matrix and analyte solution to the surface of a rotating ball upon which MALDI is carried out. The ball is in contact with a polymer gasket surrounding the capillary. Sample adhering to the surface of the ball is dragged past the gasket into the vacuum of the mass spectrometer where it is irradiated by a pulsed UV laser, and the resulting ions are mass-separated in a linear time-of-flight mass spectrometer. The mechanical sample introduction prevents clogging of the vacuum interface by matrix crystals or frozen solvent. Preliminary results from flow injection analysis (FIA) suggest that the new interface does not introduce a significant peak-tailing or memory effect. The system is capable of 20-30 h of continuous operation with a flow rate of 2 microL/min before cleaning of the ball is needed. With the prototype inlet, concentration detection limits are at the low micromolar level.

Animals↗

[A novel light-emitting diode-induced fluorescence detector for micro-scale flow analysis system].

A compact light-emitting diode-induced fluorescence detector based on collinear scheme is described. The detector was assembled by all-solid-state optical-electronic components and easily coupled with micro-scale flow analysis system by on-column detection mode. Fluorescein isothiocyanate (FITC) and FITC-labeled amino acids were used as test analytes to evaluate the detector performance by capillary electrophoresis and flow injection analysis techniques. The concentration limit of detection was 10(-8) mol x L(-1) for FITC-labeled phenylalanine at a signal-to-noise ratio (S/N) of 3 (on-column, 0.05 mm i.d.). The system exhibited a good linear response in the range of 1 x 10(-7) -2 x 10(-5) mol x L(-1) (r2 = 0.999). The relative standard deviation (RSD) of 6 repetitive injections on peak heights is less than 3%.

English Abstract↗

ESI-MS/MS analysis of underivatised amino acids: a new tool for the diagnosis of inherited disorders of amino acid metabolism. Fragmentation study of 79 molecules of biological interest in positive and negative ionisation mode.

The diagnosis of inherited disorders of amino acids (AA) metabolism is usually performed on automated analysers by ion-exchange chromatography and quantification after ninhydrin derivatisation of about 50 different AA. A single run liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for these molecules can be an alternative to this time-consuming technique. The first step of this development is the infusion study of the fragmentation of 79 molecules of biological interest in electrospray ionisation tandem mass spectrometry (ESI-MS/MS), in positive and in negative ionisation mode. Among them, three molecules can be detected only in negative ionisation mode, 38 only in positive mode and 38 in the two modes. All the most abundant fragmentations are presented, with optimisation of the MS/MS parameters. The positive ionisation mode was retained for the simultaneous analysis of 76 molecules. One sensitive and/or specific transition is proposed for the monitoring of each molecule. Improvement in sensitivity of detection was obtained with the use of an acidic mobile phase. Flow injection analysis studies led us to highlight a number of interferences-due to isobaric molecules, to in-source collision-induced dissociation, or to natural isotopic distribution of the elements-which are listed. For a reliable quantification method, these molecules have to be separated by LC before analysis in the tandem mass spectrometer. Ion-pairing reversed-phase liquid chromatography (RPLC) using perfluorinated carboxylic acids as ion-pairing agents has already been found suitable for analysis of AA in MS/MS positive ionisation mode and is under development.

Amino Acid Metabolism, Inborn Errors↗

Amperometric detection in TMB/HRP-based assays.

3,3',5,5'-Tetramethylbenzidine (TMB) is the most commonly used chromogen for horseradish peroxidase (HRP) and so its performance as an electrochemical substrate was evaluated. Measurements of HRP activity in solution were carried out by using an amperometric detector coupled to a flow injection analysis (FIA) system. The enzymatic product was easily detected at a potential of +0.1 V (vs. Ag-pseudoreference electrode) at a bare screen-printed electrode placed in a homemade electrochemical flow cell. A high flow rate (4.3 mL min(-1)) of 0.5 M H2SO4 was used to obtain repeatable signals and a short analysis time. The detection limit achieved after 15 min of incubation was 2x10(-14) M of HRP. The applicability of the amperometric detector to ELISAs was demonstrated by using a commercially available kit for the quantification of interleukin-6 (IL-6) without modifying the kit manufacturer's protocol or the reagents for this test.

Benzidines↗

Development of electrochemical methods for determination of tramadol--analytical application to pharmaceutical dosage forms.

A square-wave voltammetric (SWV) method and a flow injection analysis system with amperometric detection were developed for the determination of tramadol hydrochloride. The SWV method enables the determination of tramadol over the concentration range of 15-75 microM with a detection limit of 2.2 microM. Tramadol could be determined in concentrations between 9 and 50 microM at a sampling rate of 90 h(-1), with a detection limit of 1.7 microM using the flow injection system. The electrochemical methods developed were successfully applied to the determination of tramadol in pharmaceutical dosage forms, without any pre-treatment of the samples. Recovery trials were performed to assess the accuracy of the results; the values were between 97 and 102% for both methods.

Dosage Forms↗

An overview of analytical applications of time of flight-mass spectrometric (TOF-MS) analyzers and an inductively coupled plasma-TOF-MS technique.

A brief overview of the applications of time-of-flight mass spectrometry (TOF-MS) for analytical purposes is presented. The performance of TOF-MS combined with an inductively coupled plasma (ICP) ion source is discussed in detail. The advantages of TOF-MS detectors over the quadrupole mass filters for multi-elemental analysis of fast transient signals are discussed. The applications of ICP-TOF-MS for the detection of signals from laser ablation, electrothermal vaporization, gas and liquid chromatography, capillary electrophoresis and flow-injection analysis are reviewed.

Journal Article↗

Automated simultaneous monitoring of nitrate and nitrite in surface water by sequential injection analysis.

A fully automated procedure based on Sequential Injection Analysis (SIA) methodology for simultaneous monitoring of nitrate and nitrite in surface water samples is described. Nitrite was determined directly using the Griess diazo-coupling reaction and the formed azo dye was measured at 540 nm in the flow cell of the fibre-optic spectrophotometer. Nitrate zone was passed through a reducing mini-column containing copperised-cadmium. After the reduction of nitrate into nitrite the sample was aspirated by flow reversal to the holding coil, treated with the reagent and finally passed through the flow cell. The calibration curve was linear over the range 0.05-1.00 mg N l(-1) of nitrite and 0.50-50.00 mg N l(-1) of nitrate; correlation coefficients were 0.9993 and 0.9988 for nitrite and nitrate, respectively. Detection limits were 0.015 and 0.10 mg N l(-1) for nitrite and nitrate, respectively. The relative standard deviation (RSD) values (n = 3) were 1.10% and 1.32% for nitrite and nitrate, respectively. The total time of one measuring cycle was 250 s, thus the sample throughput was about 14 h(-1). Nitrate and nitrite were determined in the real samples of surface water, and the results have been compared with those obtained by two other flow methods; flow injection analysis based on the same reactions and isotachophoretic determination used in a routine environmental control laboratory.

Automation↗

The combination of liquid chromatography/tandem mass spectrometry and chip-based infusion for improved screening and characterization of drug metabolites.

An approach has been developed for drug metabolism studies of non-radiolabeled compounds using on-line liquid chromatography/tandem mass spectrometry (LC/MS/MS) combined with chip-based infusion following fraction collection. The potential of this approach, which improves the data quality compared with only LC/MS analysis, has been investigated for the analysis of in vitro metabolites of tolcapone and talinolol, two compounds with well-characterized metabolism. The information-dependent LC/MS/MS analysis enables the characterization of the major metabolites while the chip-based infusion is used to obtain good product ion spectra for lower level metabolites, to generate complementary MS information on potential metabolites detected in the LC/MS trace, or to screen for unexpected metabolites. Fractions from the chromatographic analysis are collected in 20 second steps, into a 96-well plate. The fractions of interest can be re-analyzed with chip-based infusion on a variety of mass spectrometers including triple quadrupole linear ion trap (QqLIT or Q TRAP) and QqTOF systems. Acquiring data for several minutes using multi-channel acquisition (MCA), or signal averaging while infusing the fractions at approximately 200 nL/min, permits about a 50 times gain in sensitivity (signal-to-noise) in MS/MS mode. A 5-10 microL sample fraction can be infused for more than 30 min allowing the time to perform various MS experiments such as MS(n), precursor ion or neutral loss scans and accurate mass measurement, all in either positive or negative mode. Through fraction collection and infusion, a significant gain in data quality is obtained along with a time-saving benefit, because the original sample needs neither to be re-analyzed by re-injection nor to be pre-concentrated. Therefore, a novel hydroxylated talinolol metabolite could be characterized with only one injection.

Animals↗

Development of an on-line coupling of liquid-liquid extraction, normal-phase liquid chromatography and high-resolution gas chromatography producing an analytical marker for the prediction of mutagenicity and carcinogenicity of bitumen and bitumen fumes.

A fast and fully automated system for the determination of polycyclic aromatic compounds (PACs) is described. The system has been developed to produce an analytical 'marker', correlating chemical characteristics (including PAC analysis) with mutagenicity and carcinogenicity. The products of interest are bitumen fumes, bitumen and other (heavy or even residual) oil products, regardless of their boiling range. Dimethyl sulphoxide (DMSO) extractables obtained from a flow-injection analysis (FIA) system are introduced on-line in a normal-phase liquid chromatographic (NPLC) system. Here, the PACs are separated from the DMSO and possible co-extracted heavy residual species. The final step incorporates on-line gas chromatographic analysis of the three-to-six-ring PAC fraction, followed by flame-ionisation detection for quantification. It was demonstrated that data obtained from samples in the distillate lubrication-oil range correlate well with data obtained from the manual DMSO-extraction method standardised by the Institute of Petroleum as IP346.

Carcinogenicity Tests↗

FTICR-mass spectrometry for high-resolution analysis in combinatorial chemistry.

The diversity of compound collections required for finding lead structures in pharmaceutical research can be provided by means of combinatorial organic chemistry. The resultant enormous number of single compounds but also of compound mixtures represents a challenge for the analyst. With the introduction of Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS or FT-MS), a new and, as yet, not widespread mass spectrometric technique (a means of analysis of such compound libraries with a very high mass resolution) high mass accuracy and high sensitivity has become available. Moreover, in combination with electrospray ionization (ESI), not only high-throughput measurements via flow-injection analysis (FIA) but also coupling with separation techniques such as high-performance liquid chromatography (HPLC) or capillary electrophoresis (CE) is possible. Structural verification by way of decomposing ions (MS(n); n > or = 2) using a variety of different dissociation techniques can be performed by FTICR-MS. This is the first review specifically covering applications of FTICR-MS in the field of combinatorial chemistry.

Automation↗

Analysis of major caprine milk proteins by reverse-phase high-performance liquid chromatography and electrospray ionization-mass spectrometry.

Major proteins from caprine milk were separated by preparative gel permeation and cation-exchange fast protein liquid chromatography and were characterized by flow injection analysis by electrospray ionization mass spectrometry. In addition, proteins from whole skim milk and whole casein were analyzed by coupling reverse-phase HPLC and electrospray ionization mass spectrometry by two different chromatographic methods. These methods successfully resolved the major caprine milk proteins and main casein variants. The experimental molecular masses of major milk proteins and variants were: 19,302 for kappa-CN 2P; 25,599 for alphas2-CN A-11P; 25,514 for alphas2-CN B-10P; 23,370 for alphas1-CN A-8P; 23,345 for alphas1-CN B-8P; 23,264 for alphas1-CN E-8P; 18,817 for alphas1-CN F-3P; 23,835 for beta-CN 6P; 18,181 for beta-LG; 14,180 for alpha-LA and 66,318 for serum albumin.

Animals↗

A flow injection-fluorometric method for the determination of ammonium in fresh and saline waters with a view to in situ analyses.

A version of the orthophthaldialdehyde-fluorescence ammonium determination for flow injection analysis (FIA) is presented here, with a view to its use for in situ, low-power consumption systems. Thus, the reaction temperature was limited to 30 degrees C and FIA was used in stop-flow mode (3 min stop). The calibration is linear up to 50 mumol l-1, but concentrations up to 100 mumol l-1 can be measured. Repeatability is around 1% in the range of 0.5-4 mumol l-1 and the detection limit is about 0.03 mumol l-1. Over the salinity range of 5-35 (seawater practical salinity scale) the salt effect is almost negligible (within +/- 2%); and below salinity of 5 it increases to a maximum of -9% in fresh water compared to seawater. Hydrogen carbonate, dissolved oxygen and turbidity (either suspended sediments or phytoplankton cells) have almost no adverse effect in a wide range of concentrations, covering most natural water conditions. Relative interference of primary amines is negligible and mercury (a common sample preservative) does not depress the signal up to 20 mg l-1 Hg II. Sulfide, that may be present in areas with anoxic waters, depresses the signal only slightly and linearly (-9% at 100 mumol l-1 S2-). The method appears to be convenient for the determination of ammonium in most coastal, estuarine and fresh waters. Sample throughput is 9 h-1. The performance of the method can be improved, either by increasing the reaction time (low throughput) or, if enough energy is available, by increasing the reaction temperature (non-stop-flow mode, high throughput). Combining FIA and fluorometry appears to be interesting for in situ determination (submersible devices) of dissolved compounds in environments with variable salinity and turbidity (especially coastal and estuarine waters).

Fluorometry↗

Determination of Co(II) by chemiluminescence after in situ electrochemical pre-separation on a flow-through mercury film electrode.

A novel method of electrochemical pre-separation of Co(II) before detection by chemiluminescence is reported together with the associated instrumentation. The Co(II) ions were selectively pre-separated on a mercury film electrode (MFE) by on-line reduction, then the accumulated metal was oxidised and selectively stripped back into the flowing solution as Co(II). These secondary ions were quantified as a result of their catalytic activity on the chemiluminescent reaction between luminol and hydrogen peroxide that was also induced on-line. The whole sequence was carried out in an automated flow-through system, in which the electrochemical pre-separation of metals was performed in either continuous flow or flow injection analysis (FIA) regimes. The scope of the method, both in terms of selectivity and sensitivity, has been demonstrated and the quantitative determination of Co(II) by the proposed method has been investigated. For a period of continuous flow pre-separation of 4 min, the calibration curve for Co(II) was linear up to a concentration of 100 micrograms l-1, the relative standard deviation was 4% at the 20 micrograms l-1 level and the limit of detection was 0.5 microgram l-1 (at the 3 sigma level). The method was applied to the determination of the cobalt content in a high purity iron sample.

Journal Article↗

Calorimetric analysis of cephalosporins using an immobilized TEM-1 beta-lactamase on Ni2+ chelating sepharose fast flow.

Two beta-lactamases, penicillinase type I from Bacillus cereus and TEM-1 beta-lactamase from Haemophilus ducreyi, were immobilized on a Chelating Sepharose Fast Flow column loaded with Ni2+ in an active form. Flow-injection analysis of beta-lactams was performed by using an enzyme column reactor fitted into the enzyme thermistor. With both enzymes it was possible to monitor both penicillins and cephalosporins. Moreover, Michaelis constants of the TEM-1 beta-lactamase were markedly increased upon immobilization for all substrates, especially carbenicillin, cephaloridine, and cefoperazone.

Anti-Bacterial Agents↗