Reproductive hazards of fire fighting. II. Chemical hazards.

Studies of the health of fire fighters have historically focused on non-malignant respiratory disease and cancer. More recently, concerns have surfaced about reproductive health effects in many areas of the workforce, including fire fighting. These concerns prompted this review of chemical exposures that may contribute to adverse reproductive health outcomes in male as well as female fire fighters. A review of the industrial hygiene literature was undertaken to identify agents commonly found in fire smoke. These agents were then examined for evidence of reproductive toxicity or mutagenicity/carcinogenicity. This profile of chemical agents and their reproductive toxicities permits a qualitative determination that fire fighters are exposed to potential reproductive toxicants as a part of their normal fire fighting duties. Considerations for mitigating these risks are also discussed.

Air Pollutants, Occupational↗

DuraPrep and the risk of fire during tracheostomy.

BACKGROUND: DuraPrep is a widely used, alcohol-based surgical prep solution. The risk of surgical fire associated with incomplete drying of this agent in the context of electrosurgical procedures has been described previously. To date, there have been no reports of fire during tracheostomy associated with a flammable prep agent before entering the airway. We describe an operating room fire occurring during awake tracheostomy associated with the use of DuraPrep. METHODS: A 62-year-old man with copious body hair underwent tracheostomy in the operating room. The neck was prepared with DuraPrep surgical solution, and after at least 3 minutes, the operative field was draped. Activation of electrocautery ignited a fire, and the patient was burned on his neck and shoulders. RESULTS: The fire was extinguished, and the patient recovered from both the tracheostomy and the burns. CONCLUSION: This case illustrates that DuraPrep should be avoided in the hirsute patient, because body hair interferes with drying of this solution and increases the risk of fire.

2-Propanol↗

Estimation and evaluation of exposures from a large sulfur fire in South Africa.

A massive fire at a sulfur stockpile in the Western Cape Province of South Africa in December 1995 is estimated to have released over 14,000 t of sulfur dioxide (SO(2)) over a 20-h period. High and persistent winds greatly reduced the effectiveness of fire-fighting activities and increased the severity of impacts. Nearby urban and agricultural areas were seriously affected. Thousands of people were evacuated from the nearby town of Macassar located 2.5-4 km downwind, and at least several deaths occurred. Agricultural impacts ranged over a broad area extending to 30 km from the fire site and included severe damage to plants and some animal deaths. This paper describes the chronology of the fire, the emergency responses, and the immediate impacts. SO(2) concentrations are estimated using dispersion modeling, and predictions are evaluated using available monitoring information. Sensitivity analyses are used to test unknown or uncertain model parameters. The SO(2) concentrations estimated in Macassar reached extremely dangerous levels, at times over the IDLH level (100 ppm). Predictions agree with the available but very limited monitoring data, as well as with the symptomology of Macassar residents and plant damage patterns. Procedures to deal with the limited information and variability in this fire and similar incidents are suggested. The fire is a tragic demonstration of shortcomings in hazardous material management and emergency response.

Adolescent↗

The New York City fire epidemic as a toxic phenomenon.

Reductions in the fire service in New York City from 1972 to 1976 appear to have caused a disproportionate increase in fire-fighter work load through several unexpected mechanisms of fire contagion. In turn, the work load increase has itself had a disproportionate physiologic impact: A classic dose-response relation has been observed between a composite measure of per capita structural fire work load and the percentage of the fire-fighting work force retiring under conditions of disability. After 1974, the increase in work load seems to have caused entry to the 'linear' portion of the dose-response curve. Implications of this synergism are explored for both New York City and other American urban areas now suffering 'fiscal crises' or planning fire service reductions.

Disability Evaluation↗

Genetic diversity impacts of forest fires, forest harvesting, and alternative reforestation practices in black spruce (Picea mariana).

Benchmarks were established for genetic diversity inherent in natural mature populations, and genetic diversity impacts of forest fires, clearcut harvesting and alternative natural and artificial silvicultural regeneration practices were determined in black spruce (Picea mariana). Allozymes of 32 loci were used to determine and compare genetic diversity and genetic relationships of adjacent or nearby four stand types: post-fire natural mature (FNM), post-fire natural young (FNR), post-harvest natural young (HNR) and post-harvest plantation (PLT), of black spruce at each of the four study sites located in two ecoregions in Manitoba: Ecoregion 90-Lac Seul Upland (Eastern) and Ecoregion 158 - Mid-Boreal Lowland (Northern). Both allelic- and genotypic-based genetic diversity parameters, as well as latent genetic potential, were determined. Black spruce populations showed typical moderate to high levels of allozyme genetic diversity. The mean genetic diversity parameters over the 16 black spruce populations sampled were as follows: percent loci polymorphic - 67%, mean number of alleles per locus - 2.52, effective number of alleles per locus - 1.70, observed heterozygosity - 0.222, expected heterozygosity - 0.308, mean number of observed genotypes per locus - 3.65, mean number of expected genotypes per locus - 5.03, genotype additivity (observed) - 116.8, genotype additivity (expected) - 161, genotype multiplicity (observed) - 6.16 x 10(15), genotype multiplicity (expected) - 2.06 x 10(19) and latent genetic potential - 26.12. The four stand types (FNM, FNR, HNR and PLT) had comparable and statistically similar genetic diversity levels at each of the four study sites as well as overall. No significant differences in black spruce genetic diversity levels were observed between the two ecoregions in Manitoba, as well as between the post-fire and post-harvest regenerated stands. No particular order of genetic relatedness among the four stand types was observed. Black spruce populations showed some sort of site-related differentiation in their genetic constitution. Allelic heterogeneity and genetic distances among populations within stand types and among four stand types suggest that the genetic diversity was maintained at the landscape level in black spruce. The results of our study demonstrate that forest fires and currently used clearcut harvesting, and alternative natural and artificial silvicultural regeneration practices, do not adversely affect genetic diversity in black spruce, and that the genetic diversity effects of clearcut harvesting are not significantly different from those due to forest fires in black spruce.

Alleles↗

Savanna fires increase rates and distances of seed dispersal by ants.

Myrmecochory (seed dispersal by ants) is a prominent dispersal mechanism in many environments, and can play a key role in local vegetation dynamics. Here we investigate its interaction with another key process in vegetation dynamics-fire. We examine ant dispersal of seeds immediately before and after experimental burning in an Australian tropical savanna, one of the world's most fire-prone ecosystems. Specifically, our study addressed the effects of burning on: (1) the composition of ants removing seeds, (2) number of seed removals, and (3) distance of seed dispersal. Fire led to higher rates of seed removal post-fire when compared with unburnt habitat, and markedly altered dispersal distance, with mean dispersal distance increasing more than twofold (from 1.6 to 3.8 m), and many distance dispersal events greater than the pre-fire maximum (7.55 m) being recorded. These changes were due primarily to longer foraging ranges of species of Iridomyrmex, most likely in response to the simplification of their foraging landscape. The significance of enhanced seed-removal rates and distance dispersal for seedling establishment is unclear because the benefits to plants in having their seeds dispersed by ants in northern Australia are poorly known. However, an enhanced removal rate would enhance any benefit of reduced predation by rodents. Similarly, the broader range of dispersal distances would appear to benefit plants in terms of reduced parent-offspring conflict and sibling competition, and the location of favourable seedling microsites. Given the high frequency of fire in Australian tropical savannas, enhanced benefits of seed dispersal by ants would apply for much of the year.

Animals↗

Pezizalean mycorrhizas and sporocarps in ponderosa pine (Pinus ponderosa) after prescribed fires in eastern Oregon, USA.

Post-fire Pezizales fruit commonly in many forest types after fire. The objectives of this study were to determine which Pezizales appeared as sporocarps after a prescribed fire in the Blue Mountains of eastern Oregon, and whether species of Pezizales formed mycorrhizas on ponderosa pine, whether or not they were detected from sporocarps. Forty-two sporocarp collections in five genera (Anthracobia, Morchella, Peziza, Scutellinia, Tricharina) of post-fire Pezizales produced ten restriction fragment length polymorphism (RFLP) types. We found no root tips colonized by species of post-fire Pezizales fruiting at our site. However, 15% (6/39) of the RFLP types obtained from mycorrhizal roots within 32 soil cores were ascomycetes. Phylogenetic analyses of the 18S nuclear ribosomal DNA gene indicated that four of the six RFLP types clustered with two genera of the Pezizales, Wilcoxina and Geopora. Subsequent analyses indicated that two of these mycobionts were probably Wilcoxina rehmii, one Geopora cooperi, and one Geopora sp. The identities of two types were not successfully determined with PCR-based methods. Results contribute knowledge about the above- and below-ground ascomycete community in a ponderosa pine forest after a low intensity fire.

Ascomycota↗

Impact-induced car fires--a comprehensive investigation.

Impact-induced car fires still attract much attention, in spite of a reduction in the rate of their occurrence in recent years. This investigation addresses several issues concerning car fire rates as a function of model year and calendar year, and the sensitivity of these rates to car impact type, impact severity, and car size. Car fuel leak occurrence rates are examined in parallel. The resolution of these issues is based on a comprehensive examination of the voluminous car accident records complied for research purposes by the National Highway Traffic Safety Administration in the past ten years. The findings show a fire rate reduction, as model years progress from the early 1970s to the mid-1980s. A significant part of this reduction takes place across model year 1976, consistent with expectations based on Federal Motor Vehicle Safety Standard No. 301 (FMVSS 301), concerning car fuel system integrity, that became essentially effective in model year 1976. However, substantial reductions of fire rates and fuel leak occurrence rates are evident as model years progress well beyond 1976. Fire and fuel-leak rates are very sensitive to impact type and impact severity; however, rate reductions are evident irrespective of impact type and impact severity. Contrary to a widely entertained notion, fire and fuel-leak rates are found to be rather insensitive to car size.

Accidents, Traffic↗

Burning radionuclide question: what happens to iodine, cesium and chlorine in biomass fires?

Fires can mobilize radionuclides from contaminated biomass through suspension of gases and particles in the atmosphere or solubilization and enrichment of the ash. Field and laboratory burns were conducted to determine the fate of I, Cs and Cl in biomass fires. Straw, wood, peat, dulse (seaweed) and radish plants were combusted with temperatures varying from 160 to 1000 degrees C, representing the normal range of field fire temperatures. Loss to the atmosphere increased with fire temperature and during a typical field fire, 80-90% of the I and Cl, and 40-70% of the Cs was lost to the atmosphere. The remainder was left behind in the ash and was soluble. Typically, the ash was enriched in I by a factor of two to three, with higher enrichments of Cs and lower enrichments of Cl, when compared to the initial fuel concentration during field burns. Most of the I was lost to the atmosphere as a gas. If the elements were radioactive isotopes, such as 129I, 137Cs and 36Cl, fires could cause an increased radiological dose to people through inhalation, exposure to ash, or ingestion of plants because of increased uptake of ash leachate.

Air Pollutants, Radioactive↗

Child fatalities in Scottish house fires 1980-1990: a case of child neglect?

This paper considers 168 child (< 17 years) fatalities killed in house fires in Scotland. Data were obtained from the records retained by the procurators fiscal, as part of a survey into all Scottish fire fatalities during the period 1980 to 1990. Although these fires were generally perceived as being tragic "accidents," we conclude that they were largely a direct result of the activities of adults in the home. We analyze this in terms of contemporaneous supervision and the child-care environment. The role of alcohol in domestic fires is particularly important. Behavioral patterns of parents and caregivers are seen to be placing children in a very high risk category and fatality rate could be significantly reduced if behavior was modified to reduce the risk. Whether these considerations imply "neglect" is partly a question of definition. It is important to recognize that the fire safety message could usefully be integrated within a more general child care or family welfare scheme. Front line professionals in these fields are ideally placed to convey this message and to make a contribution towards reducing the risk of children being killed or injured in fire.

Adolescent↗

Effects of exposure to single or multiple combinations of the predominant toxic gases and low oxygen atmospheres produced in fires.

The toxicity of single and multiple fire gases is studied to determine whether the toxic effects of the combustion products from materials can be explained by the toxicological interactions (as indicated by lethality) of the primary fire gases or if minor, more obscure gases need to be considered. LC50 values for Fischer-344 rats have been calculated for the individual gases, carbon monoxide (CO), hydrogen cyanide (HCN), or decreased oxygen (O2), for 30-min exposures plus relevant postexposure periods using the NBS Toxicity Test Method. Combination experiments with CO and HCN indicate that they act in an additive manner. Synergistic effects have been found when the animals are exposed to certain combinations of CO and carbon dioxide (CO2). Five percent CO2 raised the threshold for deaths due to hypoxia and decreased the LC50 of HCN. Decreasing the O2 concentration in the presence of various mixtures of the other major fire gases increased the toxicity even further. A comparison of the concentrations of the major combustion products generated from a number of polymeric materials at their LC50 (30-min exposure plus 14-day postexposure) values with the combined pure gas results indicates that, in most cases, the observed toxicity may be explained by the toxicological interactions of the examined primary toxic fire gases. These results provide necessary information for the computer model currently being developed at the Center for Fire Research to predict the toxic hazard that people will experience under various fire scenarios.

Air↗

Exposure of a liquefied gas container to an external fire.

In liquefied gas, bulk-storage facilities and plants, the separation distances between storage tanks and between a tank and a line of adjoining property that can be built are governed by local regulations and/or codes (e.g. National Fire Protection Association (NFPA) 58, 2004). Separation distance requirements have been in the NFPA 58 Code for over 60 years; however, no scientific foundations (either theoretical or experimental) are available for the specified distances. Even though the liquefied petroleum gas (LPG) industry has operated safely over the years, there is a question as to whether the code-specified distances provide sufficient safety to LPG-storage tanks, when they are exposed to large external fires. A radiation heat-transfer-based model is presented in this paper. The temporal variation of the vapor-wetted tank-wall temperature is calculated when exposed to thermal radiation from an external, non-impinging, large, 30.5 m (100 ft) diameter, highly radiative, hydrocarbon fuel (pool) fire located at a specified distance. Structural steel wall of a pressurized, liquefied gas container (such as the ASME LP-Gas tank) begins to lose its strength, when the wall temperature approaches a critical temperature, 810 K (1000 degrees F). LP-Gas tank walls reaching close to this temperature will be a cause for major concern because of increased potential for tank failure, which could result in catastrophic consequences. Results from the model for exposure of different size ASME (LP-Gas) containers to a hydrocarbon pool fire of 30.5 m (100 ft) in diameter, located with its base edge at the separation distances specified by NFPA 58 [NFPA 58, Liquefied Petroleum Gas Code, Table 6.3.1, 2004 ed., National Fire Protection Association, Quincy, MA, 2004] indicate that the vapor-wetted wall temperature of the containers never reach the critical temperature under common wind conditions (0, 5 and 10 m/s), with the flame tilting towards the tank. This indicates that the separation distances specified in the code are adequate for non-impingement type of fires. The model can be used to test the efficacy of other similar codes and regulations for other materials.

Environmental Exposure↗

Possible factors contributing to the postmortem lung weight in fire fatalities.

The aim of the present study was to examine the factors that contribute to the postmortem lung weight in acute fire fatalities (n=149) including those with lower (<60%) and higher (>60%) blood carboxyhemoglobin (COHb) levels (n=94 and 55, respectively). The control groups consisted of acute myocardial infarction/ischemia (AMI, n=99) and mechanical asphyxiation (n=85). For all cases (n=333), the lung and heart weights were independent of the postmortem time (4.5-72 h) and charring of the body. The combined weight of both lobes of the lung showed a significant gender difference (males>females, P<0.001), negative regression with respect to age (R=0.167, P<0.01) and positive regression with respect to heart weight (R=0.316, P<0.001). The gender difference was also significant for each cause of death even after being corrected using body height measurements. When the lung-heart weight ratio was estimated to diminish the influence of possible cardiogenic factors, the gender difference was insignificant for each cause of death among the non-elderly (<60 years of age). However, for elderly fire fatalities (>60 years of age), there was a gender difference (males>females) for the lower COHb group (P<0.05) and higher COHb group (P<0.001). A significant age-dependent difference (non-elderly>elderly) in the lung-heart weight ratio was observed for fire fatalities with a lower COHb and AMI among males and for fire fatalities with a higher COHb among females. Such gender- and/or age-dependent influences were not significant for fatal mechanical asphyxiation. These findings suggest that a person's heart weight may be a possible contributory factor to an increase in the lung weight in acute death, and that gender- and/or age-dependent susceptibilities may be additional factors that contribute to fire fatalities and AMI. In addition, elderly females appear to be most susceptible among fire casualties, and extreme cardiomegaly may also be a potential fatal risk factor.

Adolescent↗

Large-scale fires and time trends of PCDDS/DFs in sediments.

Drastic increases in PCDDs/DFs concentrations were identified in the uppermost layers of a sediment core sample taken from the coastal area of Kobe City. As large-scale fires caused by the Great Hanshin-Awaji earthquake were deemed to be a possible cause, we performed additional sampling of sediment cores and surface sediment samples, estimating the total amount of PCDDs/DFs released from fires and presuming the load to sediments by individual transport routes, such as air and water, using an air diffusion model to investigate the influence of fires. The total amount of PCDDs/DFs released from fires was estimated at 2000 g-total PCDDs/DFs, 22 g-TEQ. Increases in PCDDs/DFs generated in fires were principally transported through water rather than air. If 20% of the total PCDDs/DFs formed in fires had entered water, it would correspond to the entire increase of PCDDs/DFs concentration in sediment cores.

Air Movements↗

Fire fatalities among New Mexico children.

STUDY OBJECTIVE: To explore the relationship between social conditions and fire mortality rates among children. DESIGN: Retrospective analysis of fire fatalities in children 0 to 14 years old in New Mexico. SETTING: State Office of the Medical Investigator. TYPE OF PARTICIPANTS: All 57 New Mexico children 0 to 14 years old who died from fire-related injuries from 1981 through 1991. INTERVENTIONS: Medical investigator and autopsy records were reviewed and abstracted. Demographic and housing figures were obtained from US Census reports. Data were analyzed by chi 2 or by Fisher's exact test, with Bonferroni correction for multiple comparisons. RESULTS: Two thirds of decedents were male (P = .0014), and three fourths were less than 5 years old (P < .0001). Children living in mobile homes had triple the mortality rate of those in houses or apartments, and children in homes without plumbing (substandard) had more than ten times the mortality rate of those in houses or apartments (P < .0001). Two thirds of the victims in substandard homes were Native American (P < .0001). Errors or negligence of adults occurred in more than half of the deaths. Eighty-two percent of decedents died at the scene; only 11% reached a burn center. CONCLUSION: Substandard homes are associated with an increased fire mortality rate among children. Strategies to prevent childhood fire fatalities should address housing conditions and adult safety practices. Enhanced prehospital or burn unit care is unlikely to greatly affect childhood fire mortality rates.

Accidents, Home↗

Teaching developmentally disabled persons how to react to fires.

Four elements of fire reaction are delineated: investigating, reporting, suppressing, and evacuating areas in which fires are present. Important issues in the acquisition, maintenance, and generalization of fire reaction skills for developmentally disabled persons are identified and reviewed. Learning-based treatment strategies and fire safety literature relevant to the authors' concerns are reviewed. The authors suggest that behavioral research on training should be congruent with fire safety experts' recommendations on fire reaction skills.

Accident Prevention↗

A study of the behaviour of a protected vessel containing LPG during pool fire engulfment.

Theoretical and experimental investigations of various methods for protection against fires of vessels containing liquefied petroleum gases (LPG) (safety relief valves, intumescent fire retardant coatings, thermal isolation) have been carried out. A simple mathematical model has been proposed, which describes dependences of various parameters on time. These parameters are temperature, pressure and mass of LPG, temperatures of the vessel's walls and thermal protection layer. The case of total fire engulfment of the vessel with LPG was considered. Experiments have been executed, which were aimed on the investigation of the behaviour of vessels with LPG (50 l), equipped with protective devices during total fire engulfment. It was found out that the safety valve prevented an explosion of the vessels without any other protective measures. The presence of the intumescent fire retardant coating caused a significant delay in operation of the safety valve. A rather good agreement between the theoretical and experimental data was obtained. It has been revealed that the considered methods for protection of LPG vessels are promising in regard to prevention of explosions in these vessels at the fire engulfment.

Accidents, Occupational↗

Flame burn admissions and fire fatalities in Scotland with particular reference to the Strathclyde (Glasgow) region, and their prevention.

Scotland has the highest rate of fire fatalities in the UK. Nearly 50% of the population and fire deaths in Scotland are in the Strathclyde region. The data from the burns unit at Glasgow Royal Infirmary were studied to find the number of admissions due to flame burns and see how it compared with the fire deaths. During 1981-1993, amongst 2771 admissions to the burns unit, 1181 (43%) were due to flame burns and out of these flame burn victims, 69% were adults, 16% elderly and 15% children. The distribution of cases according to the total body surface area (TBSA) involvement was 866 (73%) with 1-15%, 165 (14%) with 16-30%, and 150 (13%) with > or =31% TBSA burns. The annual number of flame burn admissions declined during 1981-1993. In the Glasgow region 50% of the domestic fires leading to non-fatal burns or to death were started by misuse of smoking materials. Chip pan fires were responsible for 8% of admissions to the burns unit. The annual number of fire fatalities when reviewed for a longer period 1973-1995 also showed a decreasing trend. Further educational and legislative measures to prevent flame burns are discussed.

Adolescent↗