Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “DUST”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38Linked to original sources

[Exposure status of East and West German households with house dust mites and fungi].

The interrelation between biological pollution of indoor spaces and health disorders, allergic symptoms and health issues in general is well known. Besides animal epithelia, the exposure to house dust mites and mould fungi is considered a serious risk factor. In the scope of a comparative study involving school beginners in East and West Germany (launched in 1991), dust was vacuumed from a total of 218 mattresses of children's beds and checked for their content of house dust mites and mould fungi. This investigation aimed at assessing the degree of exposure, to determine regional differences, if any, and to uncover the correlation between exposure and symptoms. Dust mite infestation was highest in the small town of Borken in Westphalia (in 86% of the specimens > 2 micrograms mite allergens/g of dust) and lowest in Magdeburg in Saxony-Anhalt (55.3%). Total concentrations of mould fungi varied from 1.4 x 10(3) CFU/g of dust and 300 x 10(3) CFU/g of dust with a geometric mean of 26.5 x 10(3) CFU/g of dust. A total of 41 different genera/species were identified. Most frequent were the following genera: Penicillium, Eurotium, Aspergillus, Alternaria, Epicoccum and Cladosporium. The importance of individual factors influencing was confirmed. Humidity decreases the higher the flat is situated in a building. This partly explains the differences in concentrations between Borken where children live mainly on the ground floor, and the other cities with taller buildings. Spores of mould fungi were discovered more frequently in mattresses from humid flats. An association between biological indoor space factors and some allergological parameters seemed obvious, however, due to the small size of the test group most of them were not significant.

Air Pollution, Indoor↗

House dust mite and cockroach exposure are strong risk factors for positive allergy skin test responses in the Childhood Asthma Management Program.

BACKGROUND: Children with asthma have a high prevalence of environmental allergies, especially to indoor allergens. The relationships of exposure to indoor allergens (dust mites, cat, dog, cockroach, and molds) and other host factors to allergy sensitization have not been evaluated simultaneously in a large cohort. OBJECTIVES: We studied 1041 children aged 5 to 12 years with mild-to-moderate asthma to determine risk factors associated with having positive allergy skin test responses to indoor allergens. Also, we described, compared, and contrasted 6 allergens in the home environments of these children from 8 North American cities. METHODS: Data were used from baseline visits of the Childhood Asthma Management Program. Patients' sensitivities to house dust mites (Dermatophagoides farinae and Dermatophagoides pteronyssinus), cats, dogs, cockroaches, and molds were examined for relationships to demographic variables, home dust allergen exposures, number of other positive allergy skin test responses, total serum IgE levels, and smoking in the home. RESULTS: San Diego (78.5%) and Toronto (59.3%) had the topmost percentages of homes with moderate-to-high house dust mite levels. Boston (21.5%), St Louis (16.3%), and Baltimore (13.4%) had the highest percentages of homes with detectable levels of cockroach allergen. For house dust mites, the higher the level of allergen exposure, the more likely patients were to have positive allergy skin test responses, with relative odds of 9.0 (95% confidence interval, 5.4-15.1) for those exposed to high mite levels (>10.0 microg/g dust) relative to those unexposed. Even exposure to low levels of mite allergen (0.020-2.0 microg/g) was found to be a significant risk factor for sensitization. For cockroach allergen, those with detectable home exposure were more likely to have positive skin test responses (relative odds, 2.2; 95% confidence interval, 1.3-3.8) than those with undetectable exposure. In contrast, levels of exposure to cat, dog, and mold allergens were not related to sensitization rates. For cat allergen, this may reflect lower rates of cat ownership among highly sensitized subjects. Furthermore, the number of allergy skin test responses that were positive, excluding the test for the outcome of interest for each model, and total serum IgE levels were strong independent predictors of sensitization. CONCLUSIONS: Levels of exposure determined by house dust analysis are important determinants of sensitization for dust mite and cockroach allergen. This relationship was not demonstrable for cat, dog, or mold allergens, possibly because of confounding factors. For all allergens studied, the degree of atopy, determined by the total number of positive skin test responses or by total serum IgE levels, is an important contributing risk factor for sensitization.

Air Pollution, Indoor↗

Evaluation and field calibration of the Miniram PDM-3 aerosol monitor for measuring respirable and total coal dust.

The MIE Miniram PDM-3 is a real-time aerosol dust monitor designed to measure dust based on Mie scattering. It has an optional in-line filter that, when attached to a constant flow air sampling pump, allows a gravimetric air sample to be collected from the same air stream that passes through the Miniram sensing chamber. This study compared real-time Miniram digital respirable and total dust readings with concentrations from an in-line 5 microns polyvinyl chloride filter connected to a constant flow pump and with results from traditional respirable and total dust samples. Area samples were collected at three coal-fired power generating facilities over a 2-month period. Traditional respirable dust concentrations ranged from 0.04 to 10.8 mg/m3. In the monitored range of concentrations the Miniram respirable concentrations and the in-line respirable dust concentrations were not significantly different (p > or = 0.05), nor were the Miniram in-line filter concentrations and the side-by-side respirable dust concentrations significantly different (p > or = 0.05). However, the Miniram respirable concentrations and the traditional respirable concentrations were significantly different (p = 0.02). The Statistical Analysis System (SAS) procedure CALIS, which meets the statistical requirements for developing calibration lines for two variables each measured with error, is used to develop field calibration curves for the comparisons between direct-reading instrument concentrations and concentrations from traditional National Institute for Occupational Safety and Health methods for total and respirable dust.

Aerosols↗

Ochratoxin A and citrinin loads in stored wheat grains: impact of grain dust and possible prediction using ergosterol measurement.

Crop storage should be carried out under hygienic conditions to ensure safe products, but sometimes grain dust which has settled from previous storage may be left over and incorporated to the following stored grains. This paper describes the results obtained using a lab model developed in order to assess the impact of grain dust incorporation for its direct contribution as a contaminant but also as an inoculum in stored wheat. Settled grain dust (4 samples) released from Belgian grain storages were collected and analysed by HPLC for ergosterol, ochratoxin A (OTA) and citrinin (CIT) content. For OTA and for ergosterol, there was a high degree of variability in concentrations found in the dust samples (from 17.3-318 ng g(-1) and from 39-823 microg g(-1), respectively) whilst for CIT, the range was less significant (from 137-344 ng g(-1)). Incorporation of grain dust into wheat storage contributed to an increase in the concentrations of mycotoxins in the stored grain. Dust acts as a contaminant and as an inoculum. According to these two ways, patterns of mycotoxin generation vary with the nature of the mycotoxin, the mycotoxigenic potential of dust and the water activity of the wheat. OTA and CIT showed a very versatile image when considering the amounts of toxins produced under the selected experimental conditions. The development of a robust tool to forecast the mycotoxigenicity of dust was based on the determination of ergosterol content as a general marker of fungal biomass. Present results suggest that this predictive tool would only be valid for predicting the contamination level of CIT and OTA at reasonable moisture content (14-20%). The potential risk of having highly contaminated batches from stock to stock may thus occur and this paper discusses possible pathways leading to OTA and CIT contamination either under wet or dry storage conditions. We therefore, recommend taking precautionary measures not only by controlling and maintaining moisture at a reasonable level during storage of the raw materials but also by paying more attention to the cleaning of the stores before loading in the new harvests.

Anti-Bacterial Agents↗

Assessing the occupational risk of dust particles in the Kenyan tanning industry using rapid image processing and microscopy techniques.

The purpose of this study was to investigate the occupational hazards within the tanning industry caused by contaminated dust. A qualitative assessment of the risk of human exposure to dust was made throughout a commercial Kenyan tannery. Using this information, high-risk points in the processing line were identified and dust sampling regimes developed. An optical set-up using microscopy and digital imaging techniques was used to determine dust particle numbers and size distributions. The results showed that chemical handling was the most hazardous (12 mg m(-3)). A Monte Carlo method was used to estimate the concentration of the dust in the air throughout the tannery during an 8 h working day. This showed that the high-risk area of the tannery was associated with mean concentrations of dust greater than the UK Statutory Instrument 2002 No. 2677. stipulated limits (exceeding 10 mg m(-3) (Inhalable dust limits) and 4 mg m(-3) (Respirable dust limits). This therefore has implications in terms of provision of personal protective equipment (PPE) to the tannery workers for the mitigation of occupational risk.

Dust↗

Laboratory evaluation of pressure differential-based respirable dust detector tube.

Assessment of exposure to occupational dusts is a first step in reducing exposures to harmful dust concentrations. A new type of respirable dust sampler was developed and compared side-by-side to personal gravimetric samplers in the laboratory. The new sampler correlates filter back pressure with mass accumulation to provide mid-shift- and end-of-shift determinations of cumulative exposure. The sampler uses a small low flow rate pump to draw dust through a small detector tube that contains a porous urethane foam respirable classification section and glass fiber filter that collects respirable dust. Six different coal dusts were aerosolized in a laboratory dust chamber and a total of 119 triplicate observations were obtained. For individual coal types, the correlation coefficients were between 0.87 and 0.97. The precision of the two methods was similar, with the percent relative standard deviation of the personal samplers of 12 percent and the new detector method of 14 percent. For all coal types tested th data were best described by a power function where delta P = 1.43 mass (0.85), with a correlation coefficient of 0.73. The method becomes more accurate at higher dust loadings such that all laboratory data with mass loadings greater than an equivalent concentration of 2 mg/m3 fall within +/- 25 percent of the power function. Assessment of the method under field conditions is in progress.

Dust↗

Using water sprays to improve performance of a flooded-bed dust scrubber.

Supplemental water sprays were placed along the sides of a continuous mining machine to improve suppression and confinement of the dust cloud under the cutting boom to reduce downwind dust levels. Using a full-scale mock-up of a continuous mining machine, preliminary work showed that these side sprays improved suppression of the dust cloud and redistributed this cloud under the cutting head. This led to reductions in dust levels around the machine and in down-wind airways for some positions of the mining machine. This testing also showed that side spray effectiveness was influenced by the distance from the fresh air ventilation device to the cutting surface, termed the ventilation setback distance. These sprays produced larger reductions in machine and return dust levels at smaller setback distances than at larger setback distances. These side sprays then were installed in similar locations on a mining machine at an underground coal mine operation to evaluate their effectiveness for improving suppression and capture of dust by the flooded-bed dust scrubber. Although sampling could not be conducted successfully in the return, sampling around the mining machine and at the machine operator showed that dust levels decreased with use of these sprays. Further analysis showed that these sprays were most effective at the smaller setback distances, a result confirmed by full-scale laboratory testing.

Air Pollutants, Occupational↗

Dust collection efficiency analysis in a two-dimensional circulating granular bed filter.

Dust collection efficiency data were analyzed to determine better operating conditions for a two-dimensional circulating granular bed filter (CGBF). The dust collection efficiency in the granular bed was affected by the following operating parameters: the louver angle, the solids mass flow rate, and the particle size of the bed material. Experimental results showed that higher dust collection efficiency occurs when the solids mass flow rates were 20.34 +/- 0.24, 21.50 +/- 0.11, and 30.51 +/- 0.57 g/sec at louver angles of 45 degrees, 30 degrees, and 20 degrees, respectively. Optimal dust collection efficiency peaked with a louver angle of 30 degrees. Average particle sizes of bed material by sieve diameters (microm) of 795 microm had higher dust collection efficiency than the average collector particle size of 1500 microm. Dust collection efficiency is influenced by bed material attrition phenomenon, causing dust collection efficiency to decrease rapidly. The dust collection efficiency analysis not only found the system free of design defects but also assisted in the operation of the two-dimensional CGBF system.

Air Pollutants↗

Increase of bovine alveolar macrophage superoxide anion and hydrogen peroxide release by dusts of different origin.

The release of reactive oxygen intermediates (ROI) from bovine alveolar macrophages (BAM) after stimulation with heavy metal-containing dusts was investigated. BAM were obtained by postmortem lavages of bovine lungs. The dusts were collected from waste incineration, sewage sludge incineration, an electric power station, and from two different factories. Three quartz dusts were used as heavy metal-free controls. The dusts were fractionated by sieving and sedimentation and analyzed by electron microscopy, atomic absorption spectrometry (AAS), and atomic emission spectrometry with inductively coupled plasma (AES-ICP). Incubation of BAM with the dusts (12.5-1000 micrograms/ml medium) led to concentration-dependent increases in ROI release. The secretion of ROI was already seen after 15 min and lasted throughout the experiment up to 90 min, with the exception of a waste incinerator ash, which contained the highest contents of some heavy metals and where the release of ROI ceased after 60 min. We suggest that this dust exhibits simultaneously stimulating and inhibiting effects. The ratio of the secreted O2- and H2O2 varied, depending on the dust being investigated. The release of hydrogen peroxide correlated best, in descending order, with the content of iron, manganese, chromium, vanadium, and arsenic in the dusts.

Animals↗

Comparison of mass concentrations determined with personal respirable coal mine dust samplers operating at 1.2 liters per minute and the Casella 113A gravimetric sampler (MRE).

Measuring respirable dust concentrations in coal mine environments is currently done using approved personal respirable dust sampling equipment operating at a flow rate of 2.0 liters per minute (Lpm). Measurements made with approved coal mine dust sampling equipment are converted to equivalent concentrations that would be obtained with a Mining Research Establishment (MRE) instrument known as the Casella 113A gravimetric sampler, using a conversion factor of 1.38. NIOSH has recently recommended that coal mine dust samplers (CMDS) used to measure respirable dust levels in mine environments be operated at 1.2 Lpm and measured concentrations be multiplied by 0.91 to obtain an equivalent MRE concentration. The purpose of this recommendation is to reduce systematic error caused by the variation in mine dust distributions. This paper presents and discusses data collected in the laboratory and in underground coal mines to evaluate the recommended 1.2 Lpm flow rate and 0.91 conversion factor. Comparative measurements were obtained in the laboratory with the CMDS operating at 2.0 and 1.2 liters per minute and the MRE, using aerosols of coal and limestone dust of varying particle size distribution. Similar comparative measurements were made in a number of underground coal mines at locations with environments having particle size distributions representative of different underground mining operations. It was concluded from this study that there is no significant change in the variability associated with the constant factor used to convert respirable dust measurements, obtained with approved respirable CMDS, to equivalent MRE measurements when the flow rate of the CMDS is reduced from 2.0 to 1.2 Lpm.

Coal↗

Laboratory evaluation of the CIP 10 personal dust sampler.

The "capteur individuel de poussiere" CIP 10 personal dust sampler--developed by the Centre d'Etudes et Recherches de Charbonnages de France (CERCHAR) research organization--is a small, quiet, lightweight unit which samples at a flow rate of 10 L/min. It is a three-stage sampler, using two stages to remove nonrespirable dust particles and one stage to collect the respirable fraction. Airflow through the sampler is induced by the third stage, which is a rotating collector cup that contains a fine grade sponge. Laboratory tests were conducted in a dust chamber using aerosols of Arizona road dust, coal dust and silica dust. Aerosol concentrations measured with the CIP 10 were compared to those measured with the coal mine dust personal sampler unit used in the United States. The results of this study showed that aerosol concentrations measured with the CIP 10 were linearly related to those obtained with the coal mine dust personal sampler. The relationship, however, was dependent on preselector configuration and aerosol characteristics. The collection medium allows some small particles (less than 3 microns) to pass through the sampler without being collected. As much as 13% (by weight) of the aerosol that penetrated through the preseparating stages was exhausted from the sampler.

Aerosols↗

Experimental examination of factors that affect dust generation.

A method is presented to examine factors that affect the amount and size distribution of dust generated by falling granular material in still air. This work was conducted by using an apparatus with separate dust generating and dust measuring sections. The dust generated by a falling material was carried into an elutriation column equipped with a slotted Sierra high-volume impactor at the top. This apparatus can measure dust generation rates for particles between 0.4 and 25 microns in aerodynamic diameter as well as the amount of air entrained by the falling material. Four granular materials were tested, and a simple model was developed to describe the dust generation rate of these materials as a function of particle size, drop height, material flow, and moisture content. Moisture content strongly influenced the interparticle binding forces and the amount of dust generated. Drop height and material flow influenced the material separation forces and also significantly influenced the amount of dust generated.

Air Pollutants↗

Chemical characterization of sanding dust and methylene chloride usage in automotive refinishing: implications for occupational and environmental health.

Surface preparation activities conducted during automotive refinishing present several potential human health and environmental risks. This study examines the chemical composition of vehicle sanding dust and the prevalence of methylene chloride use as a basis for evaluating potential chemical exposures in the work environment, fugitive environmental releases, and take-home toxics. This article reports on the findings of (1) a statewide technology and work practices survey of 353 licensed auto body shops and (2) laboratory analyses of sanding dust representing more than 200 vehicles, 10 commercial body filler compounds, and work shirts worn during vehicle sanding while using nonventilated equipment. Survey data revealed that the majority of shops (78%) do not use ventilated sanding equipment, that most workers (55%) take their work clothes and shoes home at the end of the workday, and that 17% of the respondents used a methylene chloride-based paint stripper as an adjunct to mechanical sanding. Laboratory results showed that Pb, As, Cr, Mn, and Ni were present in the sanding dust at every facility tested. Lead concentrations in sanding dust were found to be highest at facilities that performed complete vehicle refinishing (range 770 to 7300 ppm) and at a collision repair shop that used a high-lead content body filler compound (1800 ppm). Hexavalent chromium also was found in two vocational high school paint dust samples at concentrations of 54 and 710 ppm. When total lead and chromium concentrations reached 7300 and 2300 ppm, respectively, facility sanding dust samples failed the U.S. Environmental Protection Agency's Toxicity Characteristic Leaching Procedure for hazardous waste. Metals found in the sanding dust also were present on the work shirts of technicians-ranging from 0.06 (Cd) to 81 (Mg) microg/inch2 of cloth-who sanded on paint without ventilated equipment. Results suggest that sanding dust and methylene chloride paint strippers used in vehicle resurfacing operations pose a potential hazard to human health and the environment.

Automobiles↗

Level and distribution of employee exposures to total and respirable wood dust in two Canadian sawmills.

Personal respirable (N = 230) and total (N = 237) dust measurements were made in two coastal British Columbia sawmills using a sampling strategy that randomly selected workers from all jobs in the mills over two seasons. Information about job title, department, season, weather conditions, location of the job relative to wood-cutting machines, and control measures also was collected at the time of sampling. Only 16 respirable wood dust samples were above the detection limit of 0.08 mg/m3; all 16 had levels < or = 0.20 mg/m3. Total wood dust concentrations were also low (36% less than the detection limit), with a mean of 0.51 mg/m3, and ranging from < 0.08 to 52 mg/m3. Measurements of exposure taken close to chippers, planers, and multiple saws had the highest total wood dust levels. Sawmill department and booth enclosures also were associated with wood dust concentrations, while local exhaust ventilation and weather conditions were not. Wood dust levels in this study were generally lower than in other studies of this industry, but most sawmill investigations report mean wood dust concentrations lower than those measured in the furniture and cabinetmaking industries, where concerns about wood dust exposures initially were raised.

British Columbia↗

The influence of common area lead hazards and lead hazard control on dust lead loadings in multiunit buildings.

Owners of multiunit buildings built before 1978 that have interior common areas, and who receive certain forms of federal assistance are generally required to address lead-based paint hazards in those common areas. This study examines the relationships between common area paint and dust lead levels and the floor dust lead loadings in associated dwelling units, as well as the effects of lead hazard control treatments in common areas. This article presents data from common areas in 145 low-income, mostly pre-1940, multiunit buildings with 342 associated dwellings in the U.S. Department of Housing and Urban Development Lead Hazard Control Grant Program at preintervention, clearance, and 1-year postintervention. Interior common areas in these multiunit buildings were not as well maintained as the dwellings in the buildings. At preintervention, a higher percent of the interior common areas had non-intact, lead-based paint on windows, doors and trim, and other interior components than in associated dwellings (95% versus 85%; 78% versus 67%; and 85% versus 62%). Common areas had preintervention entry and interior (i.e., nonentry) floor dust lead loadings more than four times higher than in dwelling units (128 versus 30 micro g/ft(2); 130 versus 28 micro g/ft(2)) while 1-year postintervention common area dust lead loadings are four to six times that of dwelling dust lead loadings (41 versus 11 micro g/ft(2); 44 versus 8 micro g/ft(2)). Windowsill dust lead loadings in common areas were twice the loadings in dwelling units at preintervention and 1-year postintervention (756 versus 383 mu g/ft(2); 154 versus 68 micro g/ft(2)). Interior common area treatments reduced geometric mean common entry dust lead loadings 71% from preintervention to clearance, and maintained those reduced levels from clearance to 1-year postintervention. Higher level interventions were not more effective than low-level interventions in reducing preintervention levels to clearance or 1-year postintervention. This study demonstrates that interior common areas in the multiunit buildings examined contain substantial amounts of deteriorated lead-based paint and dust. Remediation of common areas can effectively reduce those hazards.

Air Pollution, Indoor↗

The infrared spectrum of the Galactic center and the composition of interstellar dust.

We have obtained 5-8 micrometers spectra of the Galactic center from the Kuiper Airborne Observatory at resolving powers of approximately 50, approximately 150, and approximately 300. These spectra show absorption features at 5.5, 5.8, 6.1, and 6.8 micrometers. Together with previously observed features in the 3 micrometers region, these features are compared with laboratory spectra of candidate materials. The 3.0 and 6.1 micrometers features are due to the OH stretching and bending variations of H2O and are well fitted by water of hydration in silicates (e.g., talc). The 3.0 micrometer band is equally well fitted by ice mixtures containing 30% H2O, but such mixtures do not provide a good fit to the observed 6.1 micrometer band. The 3.4 and 6.8 micrometers features are identified with the CH stretching and deformation modes in CH2 and CH3 groups in saturated aliphatic hydrocarbons. The 6.1 micrometer band shows a short wavelength shoulder centered on 5.8 micrometer, attributed to carbonyl (C double bond O) groups in this interstellar hydrocarbon dust component. Finally, the narrow 5.5 micrometer feature is also attributed to carbonyl groups, but in the form of metal carbonyls [e.g., Fe(CO)4]. We have derived column densities and abundances along the line of sight toward the Galactic center for the various identified dust components. This analysis shows that hydrocarbon grains contain only 0.08 of the elemental abundance of C and contribute only a relatively minor fraction (0.1) of the total dust volume. Most of the interstellar dust volume is made up of silicates (approximately 0.6). Small graphite grains, responsible for the 2200 angstroms bump, account for 0.07 of the total dust volume. The remaining one-quarter of the interstellar dust volume consists of a material(s) without strong IR absorption features. Likely candidates include large graphite grains, diamonds, or amorphous carbon grains, which all have weak or no IR active modes. Finally, various models for the origin of the hydrocarbon dust component of the interstellar dust are discussed. All of them face some problems in explaining the observations, in particular, the absence of the spectroscopic signature of hydrocrbon grains in sources associated with molecular clouds.

Aircraft↗

Performance testing of the OSIRIS dust monitoring system.

OSIRIS is a monitoring system for non-fibrous dusts based on optical scattering methods. It was developed by HSE's Safety Engineering Laboratory primarily for use in the coal-mining industry as an alternative to gravimetric sampling. Up to eight dust monitors can be controlled by a microcomputer via a two-wire telemetry link at distances of up to 8 km. The paper reports the results of comparative tests between OSIRIS and the MRE 113A gravimetric sampler in a calm air dust box, in a wind tunnel and in field trials at two collieries. Results show that OSIRIS can be calibrated against the MRE 113A for a given dust and that the calibration is maintained over the normal working range of 0-40 mg m-3. Results of tests against a variety of available test dusts show that the physical and optical properties of the dust particles have a significant effect on the response of the instrument. OSIRIS therefore needs to be calibrated against a gravimetric sampler for each dust which it will be used to monitor. Once calibrated, OSIRIS would be useful in monitoring respirable dust concentrations in a wide range of industrial or laboratory situations.

Coal↗

Characterization of exposure to inhalable flour dust in Swedish bakeries.

Bakery workers are at risk of developing respiratory symptoms, such as asthma and rhinitis. Exposure to inhalable flour dust in 12 Swedish bakeries was therefore determined: concentrations of airborne inhalable flour dust were measured with the IOM personal inspirable dust sampler and the particle size distribution assessed using the IOM personal inspirable aerosol spectrometer, and the fractions of alpha-amylase, water-soluble protein and total protein in flour dust were determined. A total of 129 measurements were performed of which 77 were repeated measurements. There was a clear hierarchy in geometric mean exposure among bakery workers, with in descending order doughmakers (5.46 mg m-3), bread-formers (2.69 mg m-3), oven workers (1.17 mg m-3), and packers and confectionery workers (0.53 mg m-3). The repeated measurements revealed that within each task group there were considerable differences in mean exposure among the workers: this was demonstrated by geometric standard deviations of between-worker variance of 1.63-1.77. Partitioning of the total variability of inhalable flour dust exposure showed that the task group was the principal source of variance, accounting for 61-69% of the total variability. The optimum grouping strategy was independent of whether the oven workers and the packers were assigned to the same or to different task groups. The doughmakers and the bread-formers are two clearly distinguishable exposure groups with largely overlapping exposure distributions. On average, the flour dust contained 9% total protein, 2.3% water-soluble protein and 0.03% alpha-amylase. The inhalable flour dust was characterized by a substantial proportion of particles with a d(ac) above 10 microns. It was estimated that the thoracic subfraction contributed 39% to the total mass of inhalable dust, and the respirable subfraction 19%.

Dust↗