Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Torso”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37Linked to original sources

Low-back stresses when learning to use a materials handling device.

This study examines the potential effect of short-term practice on low-back stresses during manual lifting and lowering of a 15 kg load, and while using two different types of materials handling devices (MHDs) to lift and lower a 40 kg load. The two MHDs used were an articulated balance arm and a pneumatic hoist. The expectation was that low-back dynamic moments, EMG measured torso muscle antagonism, and EMG predicted L4/L5 disc compression forces would rapidly decrease with practice, and that the manual lift-lower activities would be learned faster than the MHD-assisted exertions. Four naïve male college age subjects performed 40 lift and lower exertions, both manually and with the two MHDs for a total of 24 experiments. Non-linear regressions of the peak and average low-back moments, EMGs and disc compression values revealed only small decreases in the values (from 2 to 14%) over the 40 trials, and it was only statistically significant for five of the 48 regressions. This would seem to indicate that if learning is present in these tasks it is going to be very slow learning, and thus future studies will need to include a much larger number of trials. The effects of MHDs on the learning rates when compared to manual lifting learning rates was not statistically significant. It was shown, however, that MHDs had a particularly beneficial effect on reducing L4/L5 compression forces during load lowering activities despite the MHD load being much heavier than the manual load. It also was found that the level of torso muscle co-contraction increased significantly (2-4 times) when MHD handling was involved compared to manual lifting and lowering.

Adult↗

Anthropometric characteristics as discriminators of body-building success.

A total of 36 non-elite male body builders were observed at the time of competition. Their mean physical characteristics (+/- S.D.) were: age, 24.6 +/- 4.8 years; height, 174.4 +/- 6.7 cm; bodyweight, 80.3 +/- 11.0 kg. Their body composition values were: percentage body fat, 9.3 +/- 1.6%; fat-free mass, 72.8 +/- 9.8 kg. The mean somatotype for all subjects was: endomorphy, 2.3 +/- 0.6; mesomorphy, 6.2 +/- 0.9; ectomorphy, 1.2 +/- 0.6. The body proportions (cm) included: biacromial diameter/bi-iliac diameter, 1.463 +/- 0.132; torso length/height, 0.468 +/- 0.018; chest circumference/abdominal circumference, 1.345 +/- 0.059. The body builders in the present study were younger, had lower bodyweights, lower fat-free mass, lower mesomorphy ratings, smaller circumferences, and smaller skeletal dimensions than elite body builders reported in the scientific literature. When the body builders in the present study were divided into successful and unsuccessful groups based on actual competition results, a multiple-discriminant analysis found that biacromial diameter/bi-iliac diameter, torso length/height, chest circumference/abdominal circumference, percentage body fat, height, and bodyweight accounted for 80.6% of the explained variance. These data indicate that the success of a body builder can be accounted for in large part by easily obtained physical variables.

Adult↗

Multilayer conformal applicator for microwave heating and brachytherapy treatment of superficial tissue disease.

PURPOSE: The purpose of this study was to construct and perform preliminary functionality evaluations of a multilayer conformal applicator with provisions for thermal monitoring, tight conformity and simultaneous microwave heating and brachytherapy treatment of large-area contoured surfaces. MATERIALS AND METHODS: The multilayer conformal applicator consists of thermal monitoring catheters for fibre-optic monitoring of skin temperatures, a waterbolus, a PCB microwave antenna array, a dielectric spacer for brachytherapy considerations, brachytherapy catheters for delivering HDR radiation and an inflatable air bladder for improving conformity to contoured surfaces. The applicator also includes an elastic attachment structure to hold the applicator securely in place on the patient. The conformity of the applicator to irregular surfaces was evaluated through CT imaging of the applicator fitted onto a life-sized human torso phantom. The fluid flow dynamics of the waterbolus, which impact the effectiveness of temperature control, were evaluated with thermometry during a 19 degrees C step change temperature of the circulating water. RESULTS: CT imaging showed improved conformity to the torso phantom surface following the application of gentle inward pressure from inflating the outer air bladder. Only a small number of 1-5 mm sized air gaps separated the conformal applicator and tissue surface. Thermometry testing of the bolus fluid flow dynamics demonstrated temperature uniformity within +/-0.82 degrees C across a 19 x 34 x 0.6 cm area bolus and +/-0.85 degrees C across a large 42 x 32 x 0.6 cm area bolus. CONCLUSION: CT scans of the applicator confirmed that the applicator conforms well to complex body contours and should maintain good conformity and positional stability even when worn on a mobile patient. Thermometry testing of two different waterbolus geometries demonstrated that uniform circulation and temperature control can be maintained throughout large, complex bolus shapes.

Brachytherapy↗

Evaluation of a redesigned self-checkout station for wheelchair users.

Self-checkout is the emergent/emerging retail technology wherein users (shoppers) check out their own items using an interactive kiosk. A dramatic growth is anticipated in the prevalence of self-checkout systems in retail environments. A study was conducted to develop and evaluate a redesign of a self-checkout system with a focus on issues related to physical accessibility for wheelchair users. Two checkout station prototypes were built: a full-scale model of an existing system and a full-scale model of a system with design modifications (e.g., inclusion of appropriate wheelchair clearance under the workstation, reduced vertical position of the credit card reader, etc.). Five wheelchair users and 10 non-wheelchair users performed simulated self-checkout activities using both workstations. The principal independent variable was workstation type (standard design vs. modified design). The dependent measures were productivity (time to complete a transaction), shoulder flexion angle, torso flexion angle, and the user's subjective assessment of the experience. The results of this study indicate that workstation type did not influence productivity levels in either participant group (wheelchair users or non-wheelchair users). Posture, on the other hand, was significantly improved: the peak shoulder angle was reduced by 64% in wheelchair users and by 69% in the non-wheelchair user group. Peak flexion angle of the torso was also reduced by 67% for wheelchair users. Subjective feedback from the wheelchair user group supported the postural data by showing an overall preference for the redesigned workstation, whereas the non-wheelchair group showed no preference between the two. These results indicate that design for populations with specific limitations does not need to come at a cost of reduced accessibility for persons without these limitations; universal design is achievable.

Architectural Accessibility↗

Kinematics used by world class tennis players to produce high-velocity serves.

The purpose of this study was to quantify ranges and speeds of movement, from shoulder external rotation to ball impact, in the tennis service actions of world class players. Two electronically synchronised 200 Hz video cameras were used to record 20 tennis players during singles competition at the Sydney 2000 Olympic games. Three-dimensional motion of 20 landmarks on each player and racquet were manually digitized. Based upon the mean values for this group, the elbow flexed to 104 degrees and the upper arm rotated into 172 degrees of shoulder external rotation as the front knee extended. From this cocked position, there was a rapid sequence of segment rotations. The order of maximum angular velocities was trunk tilt (280 degrees/s), upper torso rotation (870 degrees/s), pelvis rotation (440 degrees/s), elbow extension (1510 degrees/s), wrist flexion (1950 degrees/s), and shoulder internal rotation. Shoulder internal rotation was greater for males (2420 degrees/s) than females (1370 degrees/s), which may be related to the faster ball velocity produced by the males (50.8 m/s) than the females (41.5 m/s). Although both genders produced segment rotations in the same order, maximum upper torso velocity occurred earlier for females (0.075 s before impact) than for males (0.058 s). At impact, the trunk was tilted 48 degrees above horizontal, the arm was abducted 101 degrees and the elbow, wrist, and lead knee were slightly flexed. Male and female players should be trained to develop the kinematics measured in this study in order to produce effective high-velocity serves.

Arm↗

Pilot measurements of ELF contact currents in some electric utility occupations.

Contact currents from touching objects with different voltages can produce electric fields within the body that produce neurological and other biological effects. To begin measuring these exposures among electric utility workers, a new contact current meter (CCM) was tested in a pilot study at Southern California Edison. The CCM was worn for 82 full-shift measurements by 76 volunteers from eight occupations who did not work directly with energized electrical equipment. The volunteers were exposed to an average of 285.8 contact current events above the meter's 1-microA threshold, but most of these were electrostatic spark discharges. Fourteen employees experienced an average of 135.1 contact currents events whose primary frequency was 60 Hz. Using a circuit model of the human body, the average contact currents going from arm to arm was 9.8 microA (maximum = 178.0 microA), and the average going down the torso was 25.5 microA (maximum = 662.0). The maximum exposures were experienced by a technical support employee working in a substation. All measurements in this pilot study were below the 3000 microA maximum permissible exposure for contact currents set by the Institute of Electrical and Electronic Engineers (IEEE). Combining these current measurements with the results of high-resolution dosimetry, the internal electric fields averaged an estimated 1.7 mV/m in the heart (maximum = 21.0 mV/m), and 1.9 mV/m in the hematopoietic bone marrow in the torso (maximum = 56.5 mV/m). These internal electric fields from contact currents are below the basic restriction of 943 mV/m in the IEEE exposure standards but are above 1 mV/m, a level where biological effects have been often reported in laboratory studies. Safety concerns limited the measurements to de-energized equipment, so we did not obtain data on work in energized high-voltage environments, the most likely sources of high contact currents. This pilot study identified other improvements to the contact current meter that would make it better able to measure exposures in future health studies.

Body Burden↗

Influence of temperature and dissolved oxygen on the acute toxicity of profenofos to fathead minnows (Pimephales promelas).

The purpose of this study was to investigate the influence of temperature and dissolved oxygen levels on the acute toxicity of profenofos to fathead minnows (Pimephales promelas). Exposure conditions were as follows: normal temperature and normal dissolved oxygen (NTNO; 20 +/- 2 degrees C and 6.0-9.0 mg/L, respectively); normal temperature and low dissolved oxygen (NTLO; 20 +/- 2 degrees C and 1.7-2.6 mg/L, respectively); high temperature and normal dissolved oxygen (HTNO; 30 +/- 2 degrees C and 6.6-6.9 mg/L, respectively); high temperature and low dissolved oxygen (HTLO; 30 +/- 2 degrees C and 1.5-3.0 mg/L, respectively). Initial 96-h acute toxicity studies with profenofos were conducted at NTNO and HTLO exposure conditions. The 96-h LC50 at NTNO was 333 micrograms/L with 95% confidence limits ranging from 244 to 558 micrograms/L. However, the 96-h LC50 at HTLO was significantly lower at 21.5 micrograms/L with 95% confidence limits ranging from 17.4 to 28.8 micrograms/L. Acetylcholinesterase (AChE) activity was measured in the head and torso of surviving fish at 96-h. A weak dose-related decrease in AChE was observed at NTNO but no dose-response relationship was observed at HTLO exposure condition. Additional experiments were conducted using 50 micrograms/L profenofos at NTNO, NTLO, HTNO, and HTLO exposure conditions. Mortality, sublethal effects (erratic and hyperactive swimming), and AChE activity in the head and torso were measured at 2, 4, and 12-h following exposure to profenofos. No mortality or significant sublethal effects were observed in controls or profenofos-treated groups in NTNO and NTLO exposure conditions. However, significant mortality and sublethal effects were observed in profenofos-treated fish in HTNO at 12 h and at all time points in HTLO. Both high temperature and low dissolved oxygen, as well as combinations of high temperature and low dissolved oxygen significantly decreased AChE activity in control fish. Exposure to 50 micrograms/L profenofos in all exposure conditions further decreased AChE activity, but no apparent correlations between mortality and AChE activity were observed. These results suggest that the acute toxicity of profenofos to fathead minnows may be exacerbated during summer conditions in southern U.S. aquatic ecosystems.

Acetylcholinesterase↗

RF magnetic field penetration, phase shift and power dissipation in biological tissue: implications for NMR imaging.

The magnetic field penetration, phase shift and power deposition in planar and cylindrical models of biological tissue exposed to a sinusoidal time-dependent magnetic field have been investigated theoretically over the frequency range 1 to 100 MHz. The results are based on measurements of the relative permittivity and resistivity dispersions of a variety of freshly excised rat tissue at 37 and 25 degrees C, and are analysed in terms of their implications for human body nuclear magnetic resonance (NMR) imaging. The results indicate that at NMR operating frequencies much greater than about 30 MHz, magnetic field amplitude and phase variations experienced by the nuclei may cause serious distortions in an image of a human torso. The maximum power deposition envisaged during an NMR imaging experiment on a human torso is likely to be comparable to existing long-term safe exposure levels, and will depend ultimately on the imaging technique and NMR frequency employed.

Animals↗

Estimation of effective dose equivalent to staff in diagnostic radiology.

The irradiation of staff in diagnostic radiology was simulated for conditions commonly encountered in fluoroscopy. Scattered radiation distributions were produced from diagnostic x-ray beams generated at tube potentials in the range 60-120 kVp, using the abdomen sections of a Rando phantom. Doses to a number of organs in the head and neck were measured using a Rando phantom loaded with lithium fluoride thermoluminescent dosemeters. The torso sections were placed on a water phantom on top of a stand, with film badge dosemeters positioned on the surface of the phantom at the forehead, neck, chest and waist, and the phantom was placed in the radiation field. Doses to organs in the torso were calculated from the waist-level film badge dosemeter reading using normalised organ dose data. Radiation doses to organs below a lead apron, when worn, were estimated from the unshielded dose values using a transmission factor appropriate to the quality of the scattered radiation. The effective dose equivalent (EDE) to the phantom was calculated for various x-ray beam qualities and lead apron thicknesses and compared with the film badge doses. The results indicate that a dosemeter worn at the waist/chest level under a lead apron generally underestimates the EDE. Conversely, dosemeters worn at the forehead/neck tend to overestimate the EDE. It is recommended that a dosemeter is positioned under a lead apron, if worn.

Female↗

Localization of the site of origin of reentrant arrhythmia from body surface potential maps: a model study.

We have developed a model-based imaging approach to estimate the site of origin of reentrant arrhythmia from body surface potential maps (BSPMs), with the aid of a cardiac arrhythmia model. The reentry was successfully simulated and maintained in the cardiac model, and the simulated ECG waveforms over the body surface corresponding to a maintained reentry have evident characteristics of ventricular tachycardia. The performance of the inverse imaging approach was evaluated by computer simulations. The present simulation results show that an averaged localization error of about 1.5 mm, when 5% Gaussian white noise was added to the BSPMs, was detected. The effects of the heart-torso geometry uncertainty on the localization were also initially assessed and the simulation results suggest that no significant influence was observed when 10% torso geometry uncertainty or 10 mm heart position shifting was considered. The present simulation study suggests the feasibility of localizing the site of origin of reentrant arrhythmia from non-invasive BSPMs, with the aid of a cardiac arrhythmia model.

Arrhythmias, Cardiac↗

Comparison of conventional, model-based quantitative planar, and quantitative SPECT image processing methods for organ activity estimation using In-111 agents.

Accurate quantification of organ radionuclide uptake is important for patient-specific dosimetry. The quantitative accuracy from conventional conjugate view methods is limited by overlap of projections from different organs and background activity, and attenuation and scatter. In this work, we propose and validate a quantitative planar (QPlanar) processing method based on maximum likelihood (ML) estimation of organ activities using 3D organ VOIs and a projector that models the image degrading effects. Both a physical phantom experiment and Monte Carlo simulation (MCS) studies were used to evaluate the new method. In these studies, the accuracies and precisions of organ activity estimates for the QPlanar method were compared with those from conventional planar (CPlanar) processing methods with various corrections for scatter, attenuation and organ overlap, and a quantitative SPECT (QSPECT) processing method. Experimental planar and SPECT projections and registered CT data from an RSD Torso phantom were obtained using a GE Millenium VH/Hawkeye system. The MCS data were obtained from the 3D NCAT phantom with organ activity distributions that modelled the uptake of (111)In ibritumomab tiuxetan. The simulations were performed using parameters appropriate for the same system used in the RSD torso phantom experiment. The organ activity estimates obtained from the CPlanar, QPlanar and QSPECT methods from both experiments were compared. From the results of the MCS experiment, even with ideal organ overlap correction and background subtraction, CPlanar methods provided limited quantitative accuracy. The QPlanar method with accurate modelling of the physical factors increased the quantitative accuracy at the cost of requiring estimates of the organ VOIs in 3D. The accuracy of QPlanar approached that of QSPECT, but required much less acquisition and computation time. Similar results were obtained from the physical phantom experiment. We conclude that the QPlanar method, based on 3D organ VOIs and accurate models of the projection process, provided a substantial increase in accuracy of organ activity estimates from planar images compared to CPlanar processing and had accuracy approaching that of QSPECT.

Algorithms↗

Whole-body voxel phantoms of paediatric patients--UF Series B.

Following the previous development of the head and torso voxel phantoms of paediatric patients for use in medical radiation protection (UF Series A), a set of whole-body voxel phantoms of paediatric patients (9-month male, 4-year female, 8-year female, 11-year male and 14-year male) has been developed through the attachment of arms and legs from segmented CT images of a healthy Korean adult (UF Series B). Even though partial-body phantoms (head-torso) may be used in a variety of medical dose reconstruction studies where the extremities are out-of-field or receive only very low levels of scatter radiation, whole-body phantoms play important roles in general radiation protection and in nuclear medicine dosimetry. Inclusion of the arms and legs is critical for dosimetry studies of paediatric patients due to the presence of active bone marrow within the extremities of children. While the UF Series A phantoms preserved the body dimensions and organ masses as seen in the original patients who were scanned, comprehensive adjustments were made for the Series B phantoms to better match International Commission on Radiological Protection (ICRP) age-interpolated reference body masses, body heights, sitting heights and internal organ masses. The CT images of arms and legs of a Korean adult were digitally rescaled and attached to each phantom of the UF series. After completion, the resolutions of the phantoms for the 9-month, 4-year, 8-year, 11-year and 14-year were set at 0.86 mm x 0.86 mm x 3.0 mm, 0.90 mm x 0.90 mm x 5.0 mm, 1.16 mm x 1.16 mm x 6.0 mm, 0.94 mm x 0.94 mm x 6.00 mm and 1.18 mm x 1.18 mm x 6.72 mm, respectively.

Adolescent↗

Anatomic characterization of human ultra-weak photon emission in practitioners of transcendental meditation(TM) and control subjects.

BACKGROUND: Research on human ultra-weak photon emission (UPE, biophoton emission) has raised the question whether a typical human emission anatomic percentage distribution pattern exists in addition to individual subject overall anatomic summation intensity differences. The lowest UPE intensities were observed in two subjects who regularly meditate. Spectral analysis of human UPE has suggested that ultra-weak emission is probably, at least in part, a reflection of free radical reactions in a living system. It has been documented that various physiologic and biochemical shifts follow the long-term practice of meditation and it is inferred that meditation may impact free radical activity. OBJECTIVE: To systematically quantify, in subjects with long-term transcendental meditation (TM) experience and subjects without this experience, the UPE emission of the anterior torso, head and neck plus the hands in an attempt to document the differences by the two groups. SUBJECTS: Subjects were 20 men reported to be healthy and nonsmokers. Each of the subjects in the meditation group had practiced TM twice daily for at least the past 10 years. METHODS: UPE in 20 subjects was recorded in a dark room using a highly sensitive, cooled photomultiplier system designed for manipulation in three directions. The protocol for multisite registration of spontaneous emission includes recording of 12 anatomic locations of anterior torso, head, and hands. RESULTS: Data demonstrate emission intensities that are lower in TM practitioners as compared to control subjects. The percent contribution of emission from most anatomic locations was not significantly different for TM practitioners and control subjects. Exceptions are the contributions of throat and palm. CONCLUSION: In subjects with long-term TM experience, the UPE emission is different from control subjects. Data support the hypothesis that free radical reactions can be influenced by TM.

Adult↗

The gallium scan predicts relapse in patients with Hodgkin's disease treated with combined modality therapy.

The gallium scan (GS) is an important indicator of disease activity in untreated Hodgkin's disease, especially in the upper torso, and may be an important predictor of results for patients who have completed chemotherapy and radiotherapy (XRT). To better define the importance of the GS in predicting treatment results in a group of patients treated with uniform therapy, we performed GS prior to treatment in 46 patients with pathologically or clinically staged I-III Hodgkin's disease who received three cycles of NOVP (Novantrone, vincristine, vinblastine, prednisone) followed by XRT. Staging methods included computerized tomography (CT) of the chest, abdomen, and pelvis, lymphangiogram, and the GS, using 8 to 10 millicuries with single photon emission computed tomography (SPECT) of the upper and lower torso. Only 3 patients had negative GS before chemotherapy. After three cycles of NOVP and prior to XRT, the other 43 had repeat GS performed. Complete remission (CR) was judged by disappearance of disease after all therapy without considering GS results. The CR for those with initial positive GS was 93%. The three-year freedom from progression result for stage I-II was 94%, and the three-year overall survival was 96%; corresponding results for stage III were 86% and 100%, respectively. None of the prognostic factors for analysis, including bulky adenopathy, hilar involvement, or B symptoms, was an important predictor of results. However, only 1 of the 33 with a negative GS after these NOVP has had progressive disease compared to 3 of the 10 with a GS that remained positive.(ABSTRACT TRUNCATED AT 250 WORDS)

Antineoplastic Combined Chemotherapy Protocols↗

Isoflurane can indirectly depress lumbar dorsal horn activity in the goat via action within the brain.

We have examined the response of lumbar dorsal horn cells to a noxious mechanical stimulus during differential delivery of isoflurane to the brain and spinal cord of goats. We hypothesized that isoflurane, acting in the brain, would depress dorsal horn neuronal responses to a noxious mechanical stimulus applied to the hindlimb. Eight goats were anaesthetized with isoflurane and neck dissections performed which allowed cranial bypass. Lumbar laminectomies were performed to allow measurements of single-unit dorsal horn neuronal activity. Isoflurane 1.3% was administered before bypass, and during differential delivery it was administered at each of the following head/torso combinations: 1.3%/1.3%, 0.8%/1.3%, 0.3%/1.3%, 1.3%/0.8%, 0.8%/0.8% and 0.3%/0.8%. When the torso isoflurane concentration was 1.3%, decreasing cranial isoflurane from 1.3% to 0.3% did not significantly affect dorsal horn responses (from mean 325 (SD 262) to 379 (412) impulses min-1; P < 0.05). However, when torso isoflurane was 0.8%, decreasing cranial isoflurane from 1.3% to 0.3% increased mean evoked dorsal horn activity by 42% (388 (359) to 551 (452) impulses min-1; P < 0.05). These data suggest that the major effect of isoflurane on dorsal horn responses to noxious stimuli is direct, but there is an indirect effect occurring via descending projections from supraspinal regions.

Anesthetics, Inhalation↗

Neck muscle vibration modifies the representation of visual motion and direction in man.

The retinal coordinates of an image are normally insufficient to define the direction of an object in body-centred visual space. Gaze direction, specified by information on the position of eye-in-head and on the position of head-on-torso, is also required. While the source of the eye-in-head signal is controversial, it is clear that proprioceptive signals from neck muscles are sufficient to provide head-on-torso information. Observations by Goodwin et al., beginning in 1972, that vibration of limb muscles modifies proprioception from them, and induces illusory motion and false perception of limb position, suggested this study of the effects of neck muscle vibration on the representation of visual space. Verbal reports, supported by objective measures, revealed that vibration of muscles on one side of the neck induces a visual illusion: contralateral displacement of a small visual target viewed in the dark. Pointing movements towards the target are similarly affected, confirming that the representation of directions in visual space is modified by neck muscle vibration. A second vibration-induced illusion was uncovered when apparent displacement ceased. This is an illusion of pure target motion in the same direction as the previously observed displacement. The magnitudes of both the displacement and pure motion illusions were dependent on vibration amplitude and were unrelated to real or apparent movements of eyes or head. Taken together these observations indicate that vibration of neck muscles can modify independently (1) the central representation of the instantaneous direction of gaze and (2) the signal of the velocity with which this direction is changing.

Adult↗

Ectoparasites of Brazilian free-tailed bats with emphasis on anatomical site preferences for Chiroptonyssus robustipes (Acari: Macronyssidae).

Seven species of arthropods were recovered from 45 Brazilian free-tailed bats, Tadarida brasiliensis (I. Geoffrey), captured from May 1994 to May 1995 from a roost in Jenkins County, GA. Six species of mites were found infesting the bats, representing 5 families: Macronyssidae, Cheyletidae, Sarcoptidae, Rosensteiniidae, and Uropodidae. The macronyssid mite chiroptonyssus robustipes (Ewing) and the hemipteran bat bug, Cimex adjunctus (Barber), were collected from the host and the roost. C. robustipes was the most abundant mite (2,508 specimens) and the macronyssid Steatonyssus ceratognathus (Ewing) (189 specimens) was the 2nd most abundant mite found infesting the bats. The predatory cheyletid mite Cheyletonella vespertilionis Womersley (51 specimens) was also collected from the bats, and this is thought to be the 1st report of this mite from Georgia. In addition, Teinocoptes sp. (Sarcoptidae, 8 specimens), Nycteriglyphus sp. (Rosensteiniidae, 8 specimens), and uropodid mites (5 specimens) were removed from the bats. Of the 45 bats examined, all 30 females and 14 of 15 males were infested with C. robustipes. Twenty-three bat anatomical areas were designated and all C. robustipes mites were counted to ascertain anatomical preference. This mite was significantly more abundant on the ventral wing membrane areas posterior to the radiusulna and on the lower torso. Protonymphs of C. robustipes predominated on the wing membranes of the bats, whereas adult mites were more concentrated on the torso and head.

Animals↗

A bizarre case of vehicular suicide.

The upper torso of a man was discovered under a highway sign next to tire tread marks leading from the highway and continuing beyond the sign. The victim's lower torso and automobile were also found along the same path 31 m (101 ft) and 41 m (133 ft) beyond the sign, respectively. The decedent was initially thought to be a disposed, homicide victim who had been dismembered by his assailant(s). Accident reconstruction revealed that the victim was the driver of the automobile and was transected by the highway sign stanchion as he protruded through the passenger side window of his moving vehicle. Based on the scene findings, autopsy, and psychological autopsy, the manner of death was classified as suicidal. The criteria used by medical examiners for vehicular suicide are also discussed.

Adult↗