Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “RADIATION MONITORING”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37Linked to original sources

Calibration of TLD badges for photons of energy above 6 MeV and dosimetric intricacies in high energy gamma ray fields encountered in nuclear power plants.

CaSO4:Dy and LiF TLDs do not exhibit photon energy dependence beyond +/-55% for photons in the energy range from 1 MeV to about 7 MeV. However, when sandwiched between metal filters or used in TLD badge holders having metal filters, the response changes for irradiation from high energy photons as compared to that from 60Co gamma rays (generally used for reference calibrations). This effect is about the same for both the lower atomic number TLD (LiF) and higher atomic number TLD (CaSO4:Dy). For TLDs held on the surface of the phantom and irradiated in collimated photon beams, the response of TLDs without any filter or those under the open window of the TLD badge is considerably reduced due to insufficient build-up to high energy photons, whereas for uncollimated radiation fields from power reactors, an over-response is observed. It is observed that the use of inappropriate encapsulation of dosemeters would cause a significant error not only in the estimation of doses due to penetrating radiations but also in the estimation of beta doses in the mixed fields of beta radiation, high energy gamma rays and high energy electrons often encountered in the fields of pressurised heavy water reactors.

Calcium Sulfate↗

Dosimetry for occupational exposure to cosmic radiation.

In the course of their work, aircraft crew and frequent flyers are exposed to elevated levels of cosmic radiation of galactic and solar origin and secondary radiation produced in the atmosphere, aircraft structure, etc. This has been recognised for some time and estimates of the exposure of aircraft crew have been made previously and included in, for example, UNSCEAR (United Nations Scientific Committee on the Effects of Atomic Radiation) publications. The recent increased interest has been brought about by several factors--the consideration that the relative biological effectiveness of the neutron component as being underestimated; the trend towards higher cruising altitudes for subsonic commercial aircraft and business jet aircraft; and, most importantly, the recommendations of the International Commission on Radiological Protection (ICRP) in Publication 60, and the revision of the Euratom Basic Safety Standards Directive (BSS). In 1992, the European Dosimetry Group (EURADOS) established a Working Group to consider the exposure to cosmic radiation of aircraft crew, and the scientific and technical problems associated with radiation protection dosimetry for this occupational group. The Working Group was composed of fifteen scientists (plus a corresponding member) involved in this field of study and with knowledge of radiation measurement at aviation altitudes. This paper is based on the findings of this Working Group. Where arrangements are made to take account of the exposure of aircraft crew to cosmic radiation, dose estimation procedures will not be necessary for persons for whom total annual doses are not liable to exceed 1 mSv, and therefore, in general, for crew on aircraft not routinely flying above 8 km. Where estimates of effective dose and, in the case of female staff who are pregnant, equivalent dose to the embryo or fetus, are required (for regulatory or other purposes), it was concluded that the preferred procedure was to determine route doses and fold these with data on staff rostering.

Aircraft↗

Results of dosimetric measurements in space missions.

Detector packages consisting of thermoluminescence detectors (TLDs), nuclear emulsions and plastic nuclear track detectors were exposed in different locations inside spacecraft. The detector systems, which supplement each other in their registration characteristics, allow the recording of biologically relevant portions of the radiation field independently. Results are presented and compared with calculations. Dose equivalents for the astronauts have been calculated based on the measurements; they lie between 190 microSv d-1 and 860 microSv d-1.

Astronauts↗

Cosmic radiation exposure on Canadian-based commercial airline routes.

As a result of the recent recommendations of ICRP 60 and in anticipation of possible regulation on occupational exposure of commercial aircrew, a two-part investigation was carried out over a one-year period to determine the total dose equivalent on representative Canadian-based flight routes. As part of the study, a dedicated scientific measurement flight (using both a conventional suite of powered detectors and passive dosimetry) was used to characterise the complex mixed radiation field and to intercompare the various instrumentation. In the other part of the study, volunteer aircrew carried (passive) neutron bubble detectors during their routine flight duties. From these measurements, the total dose equivalent was derived for a given route with a knowledge of the neutron fraction as determined from the scientific flight and computer code (CARI-LF) calculations. This investigation has yielded an extensive database of over 3100 measurements providing the total dose equivalent for 385 different routes. By folding in flight frequency information and the accumulated flight hours, the annual occupational exposures of 26 flight crew have also been determined. This study has indicated that most Canadian-based domestic and international aircrew will exceed the proposed annual ICRP 60 public limit of 1 mSv.y-1, but will he well below the occupational limit of 20 mSv.y-1.

Aerospace Medicine↗

Hearing aids' electromagnetic immunity to environmental RF fields.

In this work, the electromagnetic interference on hearing aids was evaluated. Electromagnetic (EM) immunity tests on different types of hearing aids were carried out, using signals of intensity and modulation comparable to those present in the environment. The purpose of this work is to characterise the interference, establishing the immunity threshold for different frequencies and finding out which types of hearing aids are more susceptible, and in which frequency range. The tests were carried out in a GTEM cell on seven hearing aids, using AM and GSM signals in the radiofrequency (RF) range.

Cell Phone↗

Why can't we find a better biological indicator of dose?

The three general principles of the International Commission on Radiological Protection (ICRP) are: justification, optimisation (ALARA) and dose limitation. The principle application of optimisation (ALARA) for occupational exposures of workers or the public to external radiation is reliant on low doses being assessed accurately, which could be achieved using biological dosimetry. Although cytogenetic analyses for dicentrics and translocations are the most useful techniques for biological dosimetry, these were initially developed for and have been applied to middle and high range dose exposures; the range where deterministic injury is possible. Application of these techniques for biomonitoring or screening of relatively large groups of low exposed people is possible but limited as chromosome analysis is time-consuming and requires highly skilled personnel. In addition, some technical considerations constrain dose estimation in the low dose range. This paper considers the advantages of cytogenetic techniques for biodosimetry and also highlights their limitation at low doses. However, optimisation of low dose assessment could be obtained by improvement in the technique perhaps in combination with other approaches that consider variations in individual sensitivity. Developments in modern molecular biology have brought new approaches into prospect but so far they are not routinely applicable. The potential use and throughput of these new technologies is discussed.

Chromosome Aberrations↗

Dose quantities in radiation protection and their limitations.

For more than 50 years the quantity absorbed dose has been the basic physical quantity in the medical applications of ionising radiation as well as radiological protection against harm from ionising radiation. In radiotherapy relatively high doses are applied (to a part of the human body) within a short period and the absorbed dose is mainly correlated with deterministic effects such as cell killing and tissue damage. In contrast, in radiological protection one is dealing with low doses and low dose rates and long-term stochastic effects in tissue such as cancer induction. The dose quantity (absorbed dose) is considered to be correlated with the probability of cancer incidence and thus risk induced by exposure. ICRP has developed specific dosimetric quantities for radiological protection that allow the extent of exposure to ionising radiation from whole and partial body external radiation as well as from intakes of radionuclides to be taken into account by one quantity. Moreover, radiological protection quantities are designed to provide a correlation with risk of radiation induced cancer. In addition, operational dose quantities have been defined for use in measurements of external radiation exposure and practical applications. The paper describes the concept and considerations underlying the actual system of dose quantities, and discusses the advantage as well as the limitations of applicability of such a system. For example, absorbed dose is a non-stochastic quantity defined at any point in matter. All dose quantities in use are based on an averaging procedure. Stochastic effects and microscopic biological and energy deposition structures are not considered in the definition. Absorbed dose is correlated to the initial very short phase of the radiation interaction with tissue while the radiation induced biological reactions of the tissue may last for minutes or hours or even longer. There are many parameters other than absorbed dose that influence the process of cancer induction, which may influence the consideration of cells and/or tissues at risk which are most important for radiological protection.

Dose-Response Relationship, Radiation↗

Adaptation of the present concept of dosimetric radiation protection quantities for external radiation to radiation protection practice.

The present concept of dosimetric radiation protection quantities for external radiation is reviewed. For everyday application of the concept some adaptations are recommended. The check of the compliance with dose limits should be performed either by the comparison with values of the respective operational quantities directly or by the calculation of the protection quantity by means of the operational quantity, the appertaining conversion coefficient and additional information of the radiation field. Only four operational quantities are regarded to be sufficient for most applications in radiation protection practice. The term equivalent should be used in the connection dose equivalent only. Proposals are made for names of frequently used operational quantities which are denoted up to now by symbols only.

Calibration↗

Calibration measurements and standards for radiation protection dosimetry.

The safe use of ionising radiation for applications in medicine, electric power production and industrial processes requires accurate measurements that are traceable to national standards. Radiological calibration laboratories provide measurements that may be used to determine the calibration coefficients for personal dosemeters and survey meters. The wide range of ionising radiation applications results in the need for a wide range of reference radiation types and intensities to be available in the calibration laboratory. The methods used and the problems encountered while developing reference radiations are discussed.

Calibration↗

Track-etched detectors for the dosimetry of the radiation of cosmic origin.

Cosmic rays contribute to the exposure on the Earth's surface as well as in its surroundings. At the surface and/or at aviation altitudes, there are mostly secondary particles created through the cosmic rays interaction in the atmosphere, which contribute to this type of exposure. Onboard a spacecraft, the exposure comes mostly from primary cosmic rays. Track-etched detectors (TED) are able to characterise both these types of exposure. The contribution of neutrons, of cosmic origin, on the Earth's surface was studied at altitudes from few hundreds to 3000 m using TED in a moderator sphere. The results obtained are compared with other data on this type of natural radiation background. The results of studies performed onboard aircraft and/or spacecraft are presented afterwards. We used TED-based neutron dosemeter, as well as a spectrometer of linear energy transfer based on a chemically etched TED. The results of studies performed onboard aircraft, as well as spacecraft, are presented and discussed, including an attempt to estimate a neutron component onboard the spacecraft. It was found that they correlate with the results of other independent investigations.

Aircraft↗

Radiation protection dosimetry for diagnostic radiology patients.

The radiation protection of patients undergoing medical X-ray examinations is governed by the principles of justification and optimisation. Radiation dosimetry is required to inform medical practitioners of the levels of exposure and hence the risks from the diagnostic procedures that they have to justify and to assist the operators of X-ray imaging equipment to determine whether their procedures are optimised. This paper describes the main dosimetric methods that have been developed to meet these requirements. Suitable radiation risk projection models are used to predict the risks to patients in the UK from computed tomography examinations, as a function of age at exposure and sex, and show that the lifetime risk of fatal cancer can reach 1 in 1000 for children. The concept of 'diagnostic reference levels' as an aid to the optimisation of medical exposures is described, and progress in implementing them in the UK is reported.

Adolescent↗

An algorithm to evaluate solar irradiance and effective dose rates using spectral UV irradiance at four selected wavelengths.

The paper shows a semi-analytical method for environmental and dosimetric applications to evaluate, in clear sky conditions, the solar irradiance and the effective dose rates for some action spectra using only four spectral irradiance values at selected wavelengths in the UV-B and UV-A regions (305, 320, 340 and 380 nm). The method, named WL4UV, is based on the reconstruction of an approximated spectral irradiance that can be integrated, to obtain the solar irradiance, or convoluted with an action spectrum to obtain an effective dose rate. The parameters required in the algorithm are deduced from archived solar spectral irradiance data. This database contains measurements carried out by some Brewer spectrophotometers located in various geographical positions, at similar altitudes, with very different environmental characteristics: Rome (Italy), Ny Alesund (Svalbard Islands, Norway) and Ushuaia (Tierra del Fuego, Argentina). To evaluate the precision of the method, a double test was performed with data not used in developing the model. Archived Brewer measurement data, in clear sky conditions, from Rome and from the National Science Foundation UV data set in San Diego (CA, USA) and Ushuaia, where SUV 100 spectroradiometers operate, were drawn randomly. The comparison of measured and computed irradiance has a relative deviation of about +/-2%. The effective dose rates for action spectra of Erythema, DNA and non-Melanoma skin cancer have a relative deviation of less than approximately 20% for solar zenith angles <50 degrees .

Algorithms↗

Generalised photon skyshine calculations.

The energy-dependent dose contributions from monoenergetic photon source points located 1.5 m above the ground have been tabulated. These values are intended to be used for regulatory compliance with site boundary dose limitations and as such are all presented in effective dose units. Standard air and soil are modelled where the air has vertical density gradient approximation. Energies from 0.05 up to 10 MeV are evaluated for dose transport up to 40 mean free paths.

Algorithms↗

Theory of radon exhalation into accumulators placed at the soil-atmosphere interface.

A theoretical analysis is provided for the phenomenon of radon diffusion into cylindrical accumulators (inverted cups), which are commonly used for the measurement of radon exhalation rates from the earth's surface. Analytical solutions to the diffusion equations in the soil and the cup spaces are obtained by a two-dimensional (2-D) analysis that takes into account the perturbation in the horizontal and vertical radon concentration profiles brought about by the presence of the cup. The mixed nature of the boundary conditions at the soil surface and the cup-soil interface is handled by dual integral equation techniques. The treatment includes steady-state and time-dependent situations with and without ventilation. Formulae are derived for the effective time constant of radon build-up in the cup and for the back diffusion correction factors in different experimental situations. It is found that the effective time constant of radon build-up is much larger than the radon decay constant and it increases for smaller cups. The back diffusion correction factors to be employed in one-time measurement methods also increase as the cup dimensions decrease. The present work provides an analytical basis of an earlier numerical treatment for the growth curve analysis of the same problem. Although the results are based on the assumptions of somewhat ideal nature for mathematical tractability, they provide upper bound estimates of the phenomenon of back diffusion. Some practical applications of the results for extracting diffusion length of radon in materials are also suggested.

Atmosphere↗

Fluence to effective dose conversion coefficients calculated for monoenergetic electrons up to 200 MeV in partial exposure geometries.

Organ doses and effective doses were calculated for monoenergetic electrons from 0.1 to 200 MeV using the EGS4 Monte Carlo simulation code and the MIRD-5 human phantom in various non-uniform exposure geometries: anterior-posterior (AP) and posterior-anterior (PA). Below 1 MeV, the skin is the main contributor to the effective dose conversion coefficients for each exposure geometry; however, above 1 MeV the calculations showed that the effective doses of partial exposures depended on the incident electron energy, the place and the size of the exposure on the body.

Dose-Response Relationship, Radiation↗

Evaluation of two personal dosemeters in polyenergetic mono- and multi-directional neutron fields.

The neutron dose-equivalent response of two commercially available electronic personal neutron dosemeters was studied in several laboratory-produced broad-spectrum neutron fields. Fluence-weighted mean energies ranged from 200 keV to 4 MeV; personal dose-equivalent rates ranged from 75 to 10 mSv h(-1); and angles of incidence were multidirectional, 0 degrees, 30 degrees and 60 degrees. Three of these fields have been shown previously to resemble ones found in CANDU (Canadian Deuterium Uranium is a registered trademark of the Atomic Energy of Canada Limited) power plant workplaces. Both dosemeters were found to perform reasonably well across the range of energy spectra and angles of incidence. One type of dosemeter displayed values of the personal dose equivalent that were, at worst, within a factor of approximately 2 of the reference values and, at best, within a few per cent of the reference values. The other type displayed values of the personal dose equivalent that were consistently within unity and 20% of the reference values. Although the radiological performance of one was found to be more accurate, this device was also found to be the less rugged of the two. Some of the data acquired in this work were compared with results previously published by others. There was consistency between these sets of data.

Humans↗

Natural radioactivity in some building materials in Cuba and their contribution to the indoor gamma dose rate.

The natural radioactivity of some building materials commonly used in Cuba was measured by gamma spectrometry. Typical concentrations encountered so far encountered are in the ranges: 47-2511 Bq kg(-1) for (40)K; 9-71 Bq kg(-1) for (226)Ra; and 2-38 Bq kg(-1) for (232)Th. The external gamma ray absorbed doses in indoor air and the corresponding effective dose-equivalents in a typical dwelling are presented in this paper.

Air Pollution, Indoor↗