Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Partial Pressure”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37Linked to original sources

[Influence of hemoglobin level, arterial oxygen partial pressure and arterial oxygen content on the results of radiation therapy in lung squamous cell cancer].

It is believed that anemia is an important prognostic factor in the case of cancer patients treated by radiation therapy. One possible explanation for this is tumor oxygenation. With respect to tumor oxygenation, the arterial oxygen content (CaO2) may be more direct indicator than hemoglobin (Hb) level. Fourty-two patients with squamous cell lung cancer treated solely by irradiation were reviewed. It was found that CaO2 was more important than the Hb level in determining a tumor response to radiation therapy. This is considered as important indirect evidence of the existence of hypoxic fractions of cells in human tumors.

Adult↗

Transcutaneous measurement of partial pressure of oxygen and carbon dioxide.

Transcutaneous monitoring is noninvasive and relatively simple to use. In neonates and small infants, this monitoring technique may provide very useful clinical information. Transcutaneous gas monitoring, using conventional electrochemical techniques, provides a means of trending the values of PaO2 and PaCO2 in most patients with relatively normal cardiovascular function. In patients with compromised cardiopulmonary function and in many adults, because of different skin structure, transcutaneous gas monitoring will not accurately reflect arterial blood gas tensions. Because transcutaneous gases depend on skin perfusion, however, it may be useful in monitoring tissue perfusion, especially in patients with peripheral vascular disease and tissue flaps. The heating of the monitoring probe necessitates frequent site changes to avoid thermal injury, which make it more labor intensive than other noninvasive monitoring methods.

Adult↗

[Intra- and postoperative effect of different hydroxyethyl starch solutions on the flow properties of the blood and on the oxygen partial pressure of the conjunctiva].

During lumbar disc operation in the flexed prone position, a decrease in conjunctival pO2 can be observed although there is an increase in systemic blood flow after infusion of colloidal volume expanders. The regions of the body situated below the heart do not profit from the increase in systemic blood flow due to compression. The pO2 decreases more significantly after the infusion of a medium-molecular-weight solution with a more marked hemodynamic effect than after the infusion of low-molecular-weight hydroxyethyl starch. As the decrease in conjunctival pO2 is considerably less after low-molecular-weight hydroxyethyl starch, improved blood fluidity may be responsible for the increased tissue perfusion in the compressed area.

Adult↗

End-tidal partial pressure of carbon dioxide as a noninvasive indicator of systemic oxygen supply dependency during hemorrhagic shock and resuscitation.

When oxygen delivery (DO2) critically decreases, oxygen consumption (VO2) becomes supply dependent. We examined whether end-tidal PCO2 (PetCO2) would identify supply dependency during shock. Five dogs (Group I) underwent progressive hemorrhage to decrease DO2 until they could no longer maintain a stable blood pressure. Five additional animals (Group II) were bled until VO2 decreased to 70% of baseline, followed by resuscitation. The PetCO2 versus time inflection point was compared with the DO2 at onset of supply dependency (DO2crit). DO2crit for Groups I and II were 6.9 +/- .4 and 8.1 +/- 1.3, respectively (p = NS), and not statistically different from the DO2 values at which PetCO2 decreased (6.6 +/- .7 and 6.3 +/- .7 mL/kg per min, respectively). AT constant minute volume, PetCO2 effectively indicated the onset of supply dependency and rapidly increased during resuscitation, paralleling the changes in VO2 in this model of hemorrhagic shock.

Animals↗

Inhibition of adriamycin-promoted microsomal lipid peroxidation by beta-carotene, alpha-tocopherol and retinol at high and low oxygen partial pressures.

Iron-dependent peroxidation of rat liver microsomes, enhanced by adriamycin, was measured in the presence of increasing concentrations of alpha-tocopherol, beta-carotene and retinol at low and high pO2. beta-Carotene and alpha-tocopherol inhibited lipid peroxidation by more than 60% when present at concentrations greater than 50 nmol/mg microsomal protein at both high and low pO2. Retinol inhibited peroxidation by 39% at concentrations greater than 100 nmol/mg microsomal protein. This maximal level of inhibition by retinol was unaltered by pO2. However, beta-carotene was more effective than alpha-tocopherol or retinol at a pO2 of 4 mmHg, whereas alpha-tocopherol was more effective under aerobic conditions. Since adriamycin-dependent lipid peroxidation is maximal at low pO2, beta-carotene may play a role in protecting against this process.

Animals↗

Modification of partial pressure of oxygen (P50) in mammalian red blood cells by incorporation of an allosteric effector of hemoglobin.

Internalization of inositol hexaphosphate (IHP) in mammalian red blood cells (RBC) produces a modification of the hemoglobin-oxygen affinity, leading to a rightward shift of the dissociation curve. The process of incorporation, based on an osmotic shock, has been tested on RBC of different species. Two dialysis protocols have been defined to transform RBC, the first one for small volumes in a cellulose bag and the other for larger volumes using a commercially available dialysis device. Different optimal conditions must be used for each species. Most of the cellular characteristics of the transformed RBC having encapsulated IHP are similar to those of native cells. For several species, such modified RBC could be reinfused and used for physiological studies.

Allosteric Regulation↗

Effect of arginine vasopressin on arterial oxygen partial pressure in the chronically catheterized fetal lamb.

Fetal plasma 2,3-Diphosphoglycerate (2,3-DPG) and glucose levels were observed during infusion of arginine vasopressin into 6 chronically catheterized fetal lambs. Low dose infusion of arginine vasopressin (5-10 mIU/min.) did not change fetal arterial blood gases significantly. At a high concentration of vasopressin (20-40 mIU/min.), infusion for 60 minutes increased fetal arterial pO2 by approximately 5 mmHg (p less than 0.005 by paired t-test), and decreased pCO2 by approximately 2 mmHg (p less than 0.005 by paired t-test) without significant changes in pH. Neither low nor high dose infusion of arginine vasopressin was accompanied by significant changes in 2,3-DPG or the glucose level.

2,3-Diphosphoglycerate↗

[Assessment of cardiac output by a non-invasive method. Estimation of partial pressure of CO2 by rebreathing of expired gas. Comparison with thermodilution].

The cardiac output was measured in 65 patients by the FICK principle after estimation of the pp CO2 in mixed venous blood by rebreathing. This technique has been used mainly during exercise, and recently in intensive care units. We used it in resting patients hospitalised for diagnosis and treatment of a range of cardiac diseases, and in patients referred to our Physiological Laboratory. The reproductibility of our results using the rebreathing method was good: the variation of the individual results averaged 8.9%. The values of the cardiac output by rebreathing were compared to those obtained by thermodilution in 30 patients. A high coefficient of correlation was found: r = 0,897 (2p less than 0,001). This non-invasive technique is simple, rapid, and easily repeatible. Its use for serial estimations of the cardiac output should be retained.

Carbon Dioxide↗

Photic stimulation study of changing the arterial partial pressure level of carbon dioxide.

To investigate the effect of the level of baseline cerebral blood flow (CBF) on local CBF augmentation by activation, we have used positron emission tomography to measure regional CBF (rCBF) in 12 normal volunteers with and without photic stimulation during hypocapnia, normocapnia, and hypercapnia. The increase in rCBF in the primary visual cortex by photic stimulation was 10.8 +/- 3.1, 18.6 +/- 9.3, and 19.5 +/- 6.1 ml 100 ml-1 min-1 in hypo-, normo-, and hypercapnia, respectively. The increase was significantly smaller in hypocapnia than in normocapnia (p < 0.005). The fractional CBF increase caused by the photic stimulation was the same in all breathing conditions. This result indicates that the magnitude of the CBF increase induced by neuronal activity correlates proportionally with the level of baseline CBF.

Adult↗

[Preliminary study of transcutaneous oxygen partial pressure in adults after discontinuing normobaric hyperoxia during intubation].

When tracheal intubation is conducted with traditional laryngoscope PtcO2 fall during the first minute after intubation; when continuous O2 supplied laryngoscope (Laryng O2) is used PtcO2 rise; the difference is statistically significant (p less than 0.001) either the subjects are in curarisation apnea or in spontaneous ventilation. With traditional laryngoscope, the fall is faster with spontaneous ventilation conditions than during curarisation apnea. Likewise in normal conscient subject the same fall is faster (p less than 0.001) during first minute of posthyperoxic spontaneous quiet ventilation than the first minute of voluntary hypocapnic apnea induced by hyperventilation during the same hyperoxia. Such results have to be taken into account for the indications of tracheal intubation technical means if hypoxic conditions are to be suspected, particularly for infants and subjects with cardio-respiratory failure.

Adult↗

Double lung transplantation without cardiopulmonary bypass: arterial to end-tidal carbon dioxide partial pressure differences.

Bilateral lung transplantation without cardiopulmonary bypass consists of two sequential single lung transplantations. Variations in ventilatory status during the procedure led us to study the (PaCO2-PE'CO2) gradient to see if PE'CO2 might reflect PaCO2. The gradient was studied in 14 patients at six times during operation. (PaCO2-PE'CO2) (kPa) was mean 1.97 (SD 0.7) after induction, 3.2 (1.4) during single lung ventilation, 1.9 (1.1) after clamping of the contralateral pulmonary artery, 2.96 (1.6) after ventilation and vascularization of the first transplant and the remaining native lung, 0.99 (0.8) during single lung ventilation with the first transplant and 1.3 (0.8) during ventilation of both transplants. With ventilation by the allograft lung(s) alone, the small (PaCO2-PE'CO2) value demonstrated improvement in ventilatory status, enabled PaCO2 to be assessed by PE'CO2 and demonstrated efficiency of the grafts.

Adult↗

Distribution of oxygen partial pressure in the carotid body region and in the carotid body (rabbit).

In the specific tissue of the rabbit carotid body as well as in the connective tissue surrounding the organ, pO2 distribution was measured with membrane-covered needle electrodes (tip diameter 1-2 microns). The histograms resulting from measurements in the specific tissue were shifted to low pO2 values as compared to other tissues. The oxygen blowing test, i.e. exposure of the carotid body to humidified 100% oxygen was employed to decide upon the site of measurement: pO2 increased when the electrode measured in the surrounding tissue (type 1 response); pO2 remained stable or slightly decreased when the electrode sampled in the specific carotid body tissue (type 2 response). After the experiment, the electrode track was reconstructed from histological serial sections and the type of reaction was related to the type of tissue. Low pO2 values were found to prevail in the specific carotid body tissue, which leads to the conclusion that the amount of low pO2 values determines the degree of chemoreceptor activity.

Animals↗

Carbon dioxide and oxygen partial pressure in expiratory water condensate are equivalent to mixed expired carbon dioxide and oxygen.

This study was to determine whether the PCONCO2 and PCONO2 which collect in the expiratory trap of a ventilator circuit are equivalent to PECO2 and PEO2. Fifty studies were performed in 34 mechanically ventilated male patients. Five milliliters of condensate fluid were collected and PECO2 and PEO2 were measured. Exhaled gases were collected simultaneously with condensate fluid for 5 min in a meteorologic balloon and FECO2 and FEO2 were measured; PECO2 and PEO2 were then calculated. The mean PECO2 was not significantly different from PCONCO2 nor was the PCONO2 significantly different from the condensate PCONO2. There was a high correlation between mixed expired PECO2 and PCONCO2 as well as PEO2 and PCONO2. These data indicate expiratory PCONCO2 and PCONO2 provide a valid reflection of PECO2 and PEO2. The PCONCO2 and PCONO2 measured in a clinical blood gas analyzer are accurate and may be used in calculation of VD/VT and in metabolic assessments.

Aged↗

Measurement of oxygen and carbon dioxide partial pressures in synovial fluid after tonometry.

A commercially available gas analyser was used to measure tension of oxygen (PO2) and carbon dioxide (PCO2) in synovial fluid samples after tonometry. Measured values of PCO2 were close to the expected (median difference 0.2 kPa, range -0.4 to 0.4) within the analysed concentration range of 4-10 kPa. No consistent difference between measured and expected values of PO2 were found for oxygen in the range 3-11 kPa (median difference 0.1 kPa, range -0.3 to 1.2). For oxygen tensions below 3 kPa, however, the measured values invariably overestimated the actual PO2, the errors ranging from 0.3 to 1.9 kPa, median 1.1. The importance of proper handling of samples was investigated and storage for 1 h at 0 degrees C in plastic syringes resulted in elevation of the PO2 levels measured (range of elevation 0.2 to 3.6 kPa, median 1.15), whilst no significant differences were found when stored in glass syringes. Within the limits stated, commercially available gas analysers may thus be used to investigate these parameters related to local tissue metabolism in effusive joint conditions.

Carbon Dioxide↗

Doxorubicin-dependent lipid peroxidation at low partial pressures of O2.

Doxorubicin semiquinone, produced by reduction of doxorubicin with xanthine oxidase or ferredoxin reductase, reacted with H2O2 to cause deoxyribose oxidation that was catalysed by sub-micromolar concentrations of complexed iron. Both the mechanism of deoxyribose oxidation and the yield of oxidation products depended on the chelator. With EDTA or diethylenetriamine penta-acetic acid (DTPA), the reactive species behaved like free . OH. However, when ADP or no chelator was present, oxidation of deoxyribose was inhibited by mannitol but not benzoate or formate and was apparently not due to free . OH. Doxorubicin semiquinone and H2O2 caused peroxidation of phospholipid liposomes when ADP or no chelator was present, but not in the presence of EDTA or DTPA. Lipid peroxidation was iron dependent over a 0.1 to 1 microM range and was maximal with a pO2 of approximately 1.5 mm Hg, when the inhibitory effect of O2 on initiation is balanced by its stimulatory effects on propagation. The results imply that H2O2 and the doxorubicin semiquinone at low iron and O2 concentrations are very effective at initiating lipid peroxidation.

Animals↗

Changes in partial pressure of carbon dioxide with time in carotid arterial blood in cats.

1. A rapidly responding CO2 sensor and cuvette were placed in the carotid artery of anaesthetized cats and changes of PCO2 in post-pulmonary capillary blood were recorded when flow through the cuvette was suddenly stopped. 2. Under control conditions when the cats breathed spontaneously or were ventilated artificially, stop-flow caused Pa, CO2 to decay by 2--5 mmHg reaching a new equilibrium in 10--15 sec. The amount by which CO2 decayed was reduced by the inhalation of high O2. The decay was enhanced by hypoxia, the inhalation or infusion of CO2. It was reversed by the administration of acetazolamide: now with stop-flow, Pa, CO2 rose by 8--15 mmHg. 3. the mechanism of this decay is uncertain. We propose that it is due to the transfer of CO2 from plasma to red cells in post-capillary blood in response to the reduction of [H+]i as H+ binds to Hb following the oxylabile release of CO2 from Hb.

Acetazolamide↗

Growth of Spirillum lipoferum at constant partial pressures of oxygen, and the properties of its nitrogenase in cell-free extracts.

Spirillum lipoferum, an N2-fixing organism, was grown at constant concentrations of dissolved O2. When supplied with NH4+ aerobically, its doubling time was 1 h; when it fixed N2 microaerophilically, its doubling time was 5-5 to 7 h and the optimal PO2 for growth was 0-005 to 0-007 atm. At its optimal PO2 for growth on N2, S. lipoferum assimilated 8 to 10 mg nitrogen/g carbon substrate used; its efficiency was less at higher PO2 levels. Nitrogenase in cell-free extracts required Mg2+ and Mn2+, and the Fe-protein was activated by Rhodospirillum rubrum activating factor. The nitrogenase had an optimal pH of 7-1 to 7-4 and an apparent Km for acetylene of 0-0036 atm. Extracts of S. lipoferum lost their nitrogenase activity on storage at -18 degrees C, and activity was restored by adding purified Fe-protein from other N2-fixing bacteria.

Acetylene↗

Single-acquisition sequence for the measurement of oxygen partial pressure by hyperpolarized gas MRI.

Magnetic resonance imaging (MRI) with hyperpolarized 3-helium gas (HP 3He) offers the possibility of studying functional lung parameters such as the alveolar oxygen concentration and oxygen depletion rate. Until now, a double-acquisition technique has been utilized to extract these parameters. A complicated single-acquisition technique was previously developed to avoid the necessity of performing two identical breathing maneuvers. The results obtained with this technique were significantly less accurate than the results obtained with the double-acquisition method. In this work, a novel, easily implemented single-acquisition sequence is presented that provides results comparable to those obtained with the established double-acquisition method. This method is demonstrated in a phantom and a pig model on a 1.5 T scanner using a 2D fast low-angle shot (FLASH) gradient-echo sequence. Numerical simulations of the time evolution of the oxygen concentration were performed. Simulation results are presented to support the experimental data. Various parameter regimes were experimentally and numerically investigated.

Animals↗