Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “PIPET”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37Linked to original sources

Investigation of the effects of solution composition and container material type on the loss of 11-nor-delta 9-THC-9-carboxylic acid.

The loss of 11-nor-delta 9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) from solution was studied using fluorescence polarization immunoassay (FPIA) technology and x-ray photoelectron spectroscopy (XPS). Several materials (glass, silylated glass, high density polyethylene, polypropylene, polystyrene, polymethylmethacrylate, Teflon, and Kynar) were studied along with three solvents (water, urine, and Abbott cannabinoids diluent). THC-COOH losses ranging from 0 to 9.7 ng/cm2 and concentration reductions to 46% of starting values were measured. XPS indicated the presence of fluorine-labeled THC-COOH at materials surfaces. A half-life of 10 min was calculated for THC-COOH loss from urine stored in high density polyethylene at room temperature. Sample handling losses during pipetting were determined and ranged from 1.1 to 7.9 ng per aliquot. The effects of sample volume and sample handling on the THC-COOH concentrations of controls were also investigated.

Dronabinol↗

Robotic solid-phase extraction of amphetamines from urine for analysis by gas chromatography-mass spectrometry.

We have evaluated the use of the Hamilton Microlab 2200 robotic pipetting system modified to conduct solid-phase extractions of amphetamines from urine. The Hamilton system is a programmable XYZ robotic sample handling instrument compatible with commercial solid-phase extraction (SPE) columns in the most commonly available sizes. During the extraction and elution steps, the system delivers programmable positive pressure with pressure controlled feedback so as to ensure consistent recovery. The system increases sample throughput while reducing technician hands-on time and improving sample-to-sample and batch-to-batch consistency. In comparison with the manual SPE method, the automated scheme provides similar analyte recovery, accuracy, and precision and a reduced potential for laboratory errors. The method's upper limits of linearity, detection, and lquantitation were, respectively, 10,000, 100, and 100 ng/mL for amphetamine and 25,000, 50, and 50 ng/mL for methamphetamine. Extraction recoveries for the compounds ranged from 88 to 101%. Carryover amounted to less than 0.02% even at 50,000 ng/mL concentrations of analyte. A typical automated run required 20 min of technician time versus 90 min for a corresponding manual SPE procedure. The automated procedure proved to be a reliable and labor-efficient addition to the laboratory.

Amphetamines↗

Determination of blood cyanide by HPLC-MS.

An original high-performance liquid chromatographic-mass spectrometric (HPLC-MS) procedure was developed for the determination of cyanide (CN) in whole blood. After the addition of K13C15N as internal standard, blood was placed in a microdiffusion device, the inner well of which was filled with a mixture of taurine (50mM in water)/naphthalene-2,3-dicarboxaldehyde (NDA, 10mM in methanol)/methanol/ concentrated (approximately 20%) ammonia solution (25:25:45:5, v/v). Concentrated H2SO4 was added to the blood sample, and the microdiffusion chamber was sealed. After 30 min of gentle agitation, 2 microL of the contents of the inner vial were pipetted and directly injected onto a NovaPak C18 HPLC column. Separation was performed by a gradient of acetonitrile in 2mM NH4COOH, pH 3.0 buffer (35-80% in 10 min). Detection was done with a Perkin-Elmer Sciex API-100 mass analyzer with an ionspray interface, operated in the negative ionization mode. MS data were collected as either TIC or SIM at m/z (299 + 191) and (301 + 193) for the derivatives formed with CN and 13C15N, respectively. Inspired by previous works dealing with the complexation of CN by NDA + taurine to form a 1-cyano [f] benzoisoindole derivative analyzed by HPLC-fluorimetry, this method appears simple, rapid, and extremely specific. Limits of detection and quantitation for blood CN are 5 and 15 ng/mL, respectively. The use of 13C15N as internal standard allows the quantitation of CN with elegance and accuracy in comparison with previously reported methods.

Chromatography, High Pressure Liquid↗

Validation of a microtiter plate ELISA for screening of postmortem blood for opiates and benzodiazepines.

The object of this study was to evaluate the suitability of the Neogen Corp. microtiter plate enzyme-linked immunoassays (ELISA) for opiates and benzodiazepines for screening of postmortem blood. Ninety postmortem whole blood specimens were obtained from drug-involved deaths which had been screened and confirmed positive for opiates and/or benzodiazepines. Forty negative specimens were obtained from non-opiate-involved deaths. Specimens were tested using the Neogen Opiates Group and Neogen Benzodiazepines Group microtiter plate ELISA assays. No matrix effects were found for whole blood in these assays and a dilution of 1:5 was chosen to facilitate pipetting and to bring the IC50 of the microtiter plate ELISA assay within the range of opiates and benzodiazepines encountered in medical examiner specimens. True positive, true negatives, false positives, and false negatives were determined and graphed for the ELISA results against gas chromatography-mass spectrometry (GC-MS), gas chromatography-nitrogen-phosphorus detection and case histories. From these graphs and the ROC curves, the optimal cut-off for the Neogen Opiates Group ELISA was found to be between 20 and 50 ng/mL morphine equivalents and the optimum cut-off for the Neogen Benzodiazepines Group ELISA was between 20 and 50 ng/mL temazepam equivalents. The Neogen Opiates Group ELISA had a sensitivity of 95.2% +/- 2.7% and a specificity of 92.2% +/- 3.4% versus GC-MS at a cut-off of 20-ng/mL cut-off and a sensitivity of 88.8% +/- 3.9% and specificity of 96.8% +/- 2.1% versus GC-MS at a 50-ng/mL morphine equivalents cut-off. The Neogen Benzodizepines Group ELISA had a sensitivity of 100% +/- 1.3% and a specificity of 94.6% +/- 2.9% versus GC-MS (20-ng/mL temazepam equivalents cut-off) and a sensitivity of 95.8% +/- 2.5% and specificity of 98.2% +/- 1.8% versus GC-MS at a 50-ng/mL cut-off.

Antibodies↗

Choice of an ELISA assay for screening postmortem blood for amphetamine and/or methamphetamine.

The object of this study was to evaluate the suitability of the Neogen Corp. microtiter plate enzyme-linked immunoassays (ELISA) for the screening of postmortem blood for amphetamine and methamphetamine and to choose the more appropriate assay for screening. Forty-seven postmortem whole blood specimens were obtained from drug-involved deaths, which had been screened and confirmed positive for methamphetamine and/or amphetamine. Eighty-five negative specimens were obtained from non-amphetamines-involved deaths, 17 of which involved decomposition. Specimens were tested using the Neogen Amphetamine Ultra and Neogen Methamphetamine/MDMA microtiter plate ELISA assays. No matrix effects were found for whole blood in these assays, and a dilution of 1:5 was chosen to facilitate pipetting and to bring the IC50 of the microtiter plate ELISA assay within the range of amphetamines concentrations encountered in medical examiner specimens. True positives, true negatives, false positives, and false negatives were determined relative to gas chromatography-mass spectrometry (GC-MS) and graphed for the ELISA. From these graphs and the receiver operating curves (ROC), the optimal cut-off for the Neogen Methamphetamine/MDMA ELISA was 50 ng/mL methamphetamine equivalents and the optimum cut-off for the Neogen Amphetamine Ultra ELISA was 100 ng/mL amphetamine equivalents. The Neogen Methamphetamine ELISA had a sensitivity of 93.6% +/- 3.5% and a specificity of 77.6% +/- 4.5% versus GC-MS at the cut-off of 50-ng/mL methamphetamine equivalents. The Neogen Amphetamine Ultra ELISA had a sensitivity of 95.7% +/- 3.0% and a specificity of 72.9% +/- 5.2% versus GC-MS at the 100-ng/mL amphetamine equivalents cut-off. The areas under the ROCs were equivalent for the two ELISA assays.

Amphetamine↗

Unusually high concentrations in a fatal GHB case.

The first case in France involving a fatal overdose resulting from the ingestion of gamma-hydroxybutyrate (GHB) is presented. GHB was tested by gas chromatography-mass spectrometry (GC-MS) after precipitation. Briefly, 20 microL of body fluids (blood, bile, urine, gastric contents, or vitreous humor) was pipetted in a glass tube, followed by 20 microL GHB-d6 and 45 microL acetonitrile. After vortex mixing and centrifuging, the supernatant was collected and evaporated to dryness. The residue was derivatized with BSTFA with 1% TMCS for 20 min at 70 degrees C. After injection on a 30-m HP5 MS capillary column, GHB (m/z 233, 204, and 147) and GHB-d6 (m/z 239) were identified by MS. GHB was also tested in pubic hair after incubation in 0.01 N NaOH, neutralization, acidification, extraction in ethyl acetate and derivatization with MTBSTFA, using GC-MS-MS. GHB was positive in all the tested specimens, with the following concentrations 2937, 33,727, 1800, and 2856 mg/L in femoral blood, urine, bile, and vitreous humor, respectively. This seems to be the highest blood concentration ever observed. Postmortem redistribution appears weak, as the concentration in cardiac blood was 3385 mg/L (cardiac blood/femoral blood ratio of 1.15). Oral route was suggested with GHB at 7.08 g in 100 mL of gastric contents. Pubic hair analysis clearly indicated chronic GHB abuse, with concentrations along the shaft in the range 19.4 to 25.0 ng/mg (in comparison with physiological concentrations < 2 ng/mg). Methylenedioxymethamphetamine was present in femoral blood at 144 ng/mL. These results are consistent with an acute fatal overdose of GHB.

Adult↗

Matrix modification for furnace atomic absorption spectrometric determination of arsenic in whole human blood.

A method for the determination of arsenic in whole human blood is presented. To decrease the matrix effects from this complex sample, the blood was prediluted with a matrix modifier solution. The modifier solution contained a surfactant, Triton X-100, which homogenized the sample and allowed accurate pipetting by an autosampler. The modifier also contained nickel nitrate which stabilized the arsenic and allowed ash temperatures of 1400 degrees C without loss of the arsenic. The method exhibited a sensitivity of 5 micrograms/L (concentration/1% absorption) which was sufficient for the forensic evaluation of elevated arsenic levels in the blood.

Arsenic↗

Susceptibility of immature Ixodes scapularis (Acari:Ixodidae) to plant-derived acaricides.

Plant-derived acaricides, extracted from various botanical species, and commercially available phytochemicals were evaluated for biological activity against immature Ixodes scapularis (Say) using the disposable pipet method. In addition, residual activity of the plant extracts was determined. Of the 13 plant extracts tested, 9 exhibited biological activity with Alaska yellow cedar, Chamaecyparis nootkatensis (D. Don) Spach., being the most effective against the nymphal ticks (LC50 = 0.151% wt:vol) and eastern red cedar, Juniperus virginiana L., showing the greatest activity against larval ticks (LC50 = .001% wt:vol). The commercially available products were significantly less active than the plant extracts we prepared, but some commercial compounds did exhibit limited activity. Only the Alaska yellow cedar exhibited any residual activity that lasted 21 d after treatment.

Animals↗

Volatile substances from larval habitats mediate species-specific oviposition in Anopheles mosquitoes.

Oviposition site selection has been recognized as critical both for the survival and population dynamics of mosquitoes. Volatile substances released from larval habitats have been implicated as potential olfactory cues mediating oviposition. In our continuing studies of cues involved in oviposition site selection, we collected material from the larval habitats of Anopheles albimanus Wiedemann and Anopheles vestitipennis Dyar & Knab, i.e., cyanobacterial mats and Typha domingensis Pers. litter, respectively. The volatile compounds were extracted by freeze-drying the material and trapping the volatilized material on a -55 degrees C titanium condenser. For oviposition trials conducted with wild-caught females, the tested volatile materials were pipetted onto filters floating on the surface of distilled water in Teflon beakers that were placed within oviposition cages. For both species, volatile materials in low concentrations increased oviposition, assessed as egg density, whereas there was a shift to reduced oviposition at higher concentrations. Volatile effect was strongly habitat/species-specific as shown by reciprocal treatment tests.

Animals↗

Filter paper for preservation, storage, and distribution of insect and pathogen DNA samples.

Proper DNA storage is critical for studies involving genetic analysis of insects and for molecular diagnostics of pathogens carried by them. Molecular surveillance of pathogens carried by insects can involve screening of thousands of insect DNA samples. Problems with storage and degradation of these samples can arise. In this study, a simple filter paper-based method for storage and preservation of insect DNA was evaluated using polymerase chain reaction (PCR). DNA was isolated from individual house fly, Musca domestica L., adults by using a cell lysis technique. From 50 house flies known to carry Campylobacter spp., a portion of the DNA sample was stored frozen and another portion was pipetted onto filter paper. At monthly intervals for 7 mo, PCR was conducted using 1 microl of the frozen DNA sample and a 2.0-mm disk from the filter paper samples as the PCR template. Two markers were used, a 450-bp region of the insect mitochondrial DNA (mtDNA) ND5 gene and a 857-bp region of the Campylobacter spp. mtDNA 16S rDNA gene. PCR amplification was successful for all of the samples regardless of the storage method. The filter paper method is a simple and economical way to store, preserve, and distribute DNA samples for PCR analysis.

Animals↗

High-throughput molecular testing of ticks using a liquid-handling robot.

To meet the need for high-throughput sample testing, DNA extraction kits based on the 96-well plate format have been developed for use with blood and tissue samples. These methods have not been applied to DNA extractions from ticks. To meet this need, we developed a high-throughput method for DNA extraction and polymerase chain reaction (PCR) testing of tick samples. A liquid-handling robot was used to extract DNA in a 96-well binding column plate with vacuum manifold. The quantity, purity, and quality of DNA recovered from Ixodes scapularis Say, 1821 nymphs with this method were reproducible and comparable with existing manual DNA extraction techniques. The DNA yield from pools of five nymphal ticks averaged 0.432 +/- 0.04 microg (95% CI). The robot also prepared real-time PCR reactions in 96-well plates, directly from the extracted DNA. A modification of the existing P20 tool resulted in accurate pipetting of 1- to 2-microl volumes with a reproducibility of +/- 0.038 microl when dispensing 1.0 microl. By using this process, 96 samples can be extracted and tested while reducing human labor to approximately 30 min.

Animals↗

Comparison of AluI-induced frequencies of dicentrics and translocations in human lymphocytes by chromosome painting.

It has been shown repeatedly that following irradiation of human lymphocytes in the G0 stage, more translocations are induced than dicentrics. To check the role of DNA double-strand breaks (DSB) alone for the induction of symmetrical and asymmetrical chromosome aberrations, the frequencies of induced exchange aberrations by the restriction enzyme AluI were analyzed. The enzyme was introduced into cells using the pellet pipetting technique. Frequencies of induced translocations and dicentrics were determined using a chromosome painting assay with chromosome-specific DNA libraries for chromosomes 1, 4 and X (representing 16.8% of the human genome). The number of translocations detected was approximately 3-fold higher than the number of dicentrics, indicating that the increased frequency of translocations compared with dicentrics found in irradiated human lymphocytes does not result from DNA lesions other than DSB but from differential processing of DSB.

Centromere↗

Reliable genotyping of samples with very low DNA quantities using PCR.

Our purpose was to identify an experimental procedure using PCR that provides a reliable genotype at a microsatellite locus using only a few picograms of template DNA. Under these circumstances, it is possible (i) that one allele of a heterozygous individual will not be detected and (ii) that PCR-generated alleles or 'false alleles' will arise. A mathematical model has been developed to account for stochastic events when pipetting template DNA in a very dilute DNA extract and computer simulations have been performed. Laboratory experiments were also carried out using DNA extracted from a bear feces sample to determine if experimental results correlate with the mathematical model. The results of 150 typing experiments are consistent with the proposed model. Based on this model and the level of observed false alleles, an experimental procedure using the multiple tubes approach is proposed to obtain reliable genotypes with a confidence level of 99%. This multiple tubes procedure should be systematically used when genotyping nuclear loci of ancient or forensic samples, museum specimens and hair or feces of free ranging animals.

Alleles↗

Novel method for high throughput DNA methylation marker evaluation using PNA-probe library hybridization and MALDI-TOF detection.

The methylation of CpG dinucleotides has become a topic of great interest in cancer research, and the methylation of promoter regions of several tumor suppressor genes has been identified as a marker of tumorigenesis. Evaluation of DNA methylation markers in tumor tissue requires hundreds of samples, which must be analyzed quantitatively due to the heterogeneous composition of biological material. Therefore novel, fast and inexpensive methods for high throughput analysis are needed. Here we introduce a new assay based on peptide nucleic acid (PNA)-library hybridization and subsequent MALDI-TOF analysis. This method is multiplexable, allows the use of standard 384 well automated pipetting, and is more specific and flexible than established methods, such as microarrays and MS-SNuPE. The approach was used to evaluate three candidate colon cancer methylation markers previously identified in a microarray study. The methylation of the genes Ade-nomatous polyposis coli (APC), glycogen synthase kinase-beta-3 (GSK3beta) and eyes absent 4 (EYA4) was analyzed in 12 colon cancer and 12 normal tissues. APC and EYA4 were confirmed as being differentially methylated in colon cancer patients whereas GSK3beta did not show differential methylation.

Colorectal Neoplasms↗

Useful technique for DNA-stretching and fixation.

We report on a useful technique for reproducibly straightening and fixing DNA molecules. When a droplet of DNA solution on surfaces is sucked up by pipet, surface tension at the moving air-water interface is sufficient to stretch the molecules. The point of this technique is the interaction control between surfaces and DNA molecules by polymer coating. With polymers containing pi-conjugation units (polyphenazasiline, PPhenaz and poly(vinylcarbazole), PVCz), many DNA were nicely stretched and fixed on surfaces. Furthermore, structural changes of pi-units in polymers affected DNA-stretching and fixation. By using atomic force microscopy (AFM) and scanning near-field optical/atomic force microscopy (SNOM/AFM), the feasibility of this technique for DNA observations was demonstrated.

DNA↗

A simple technique to quantify human sperm-zona pellucida binding assays.

A simplified method for assessing the degree of sperm-zona pellucida binding was developed. The zonae pellucidae of salt-stored, failed-fertilized human oocytes were each inseminated with between 1 x 10(5) and 1 x 10(6) motile spermatozoa/ml, prepared by a direct swim-up method from 11 individuals with normal sperm counts, as defined by the World Health Organization. Following 4 h of incubation at 37 degrees C in humidified air, the zonae pellucidae were 'washed' by vigorous pipetting to remove any loosely attached spermatozoa. The zonae were then placed individually in microwells and dissolved by exposure to acidified (pH < 2.0) medium to form a fluid monolayer. The slides were sealed and the number of spermatozoa in the monolayer counted by each of three observers within 24 h. There was good agreement in the counts between the different observers, with a mean coefficient of variation of only 7.4% and a range of 1.8-16.7%. It was notable that the highest coefficients of variation occurred at the extremes of sperm numbers and that the results were stable overnight. The method is also able to identify observer bias within this variation, indicating the potential for improvements in assay performance. The technique reported has the advantage over current sperm-zona pellucida binding assays of allowing the determination of the precise number of spermatozoa bound to a zona pellucida while producing a slide which remains stable overnight.

Biological Assay↗

Direct measurement of superoxide anion produced in biological systems by ESR spectrometry: a pH-jump method.

For direct measurement of the ESR signal of superoxide anion (O2-) produced in biological samples, O2- generated at a physiological pH was trapped in alkaline media instead of by a rapid freezing method, and then its signal was measured by ESR spectroscopy at 77 K. A reaction mixture for O2- generation, such as xanthine oxidase-xanthine and neutrophils, was incubated at a physiological pH (pH 7.0-7.5) for a suitable reaction period (30s), then an aliquot (300 microliters) was pipetted out and squirted into 600 microliters of 0.5 M NaOH to stabilize O2- (pH-jump). The alkaline mixture was promptly introduced into an ESR tube and frozen by dipping the tube directly into a cooling liquid. A typical signal of O2- was detected by ESR spectroscopy and the amount of trapped O2- was measured quantitatively at 77 K. The back reaction of O2- generation from H2O2 was negligible in 0.5 M NaOH. To avoid any artificial spectrum due to autoxidation of biological samples by the pH-jump procedure, the background spectrum should be subtracted from the obtained spectrum. This pH-jump method should be widely available for direct demonstration of O2- production in biological systems at physiological pH, because an advantage of this method is the simple operation for trapping O2- without the use of any rapid-mixing apparatus as compared with the rapid freezing method.

Animals↗

An inexpensive, simple protocol for DNA isolation from blood for high-throughput genotyping by polymerase chain reaction or restriction endonuclease digestion.

We describe simple, inexpensive, and reliable methods for isolating DNA from avian blood, semen, or feather pulp. The procedures are readily applicable to high-throughput 96-well plate isolation for genotype analysis of chicken DNA based on restriction endonuclease digestion or PCR. Isolation cost is primarily the cost of a deep-well assay block and a few pipet tips; current price is less than 0.10 dollar per sample, providing a significant cost advantage over commercial kits. The procedure employs inexpensive, nonhazardous reagents and yields intact, double-stranded DNA from as little as 2 to 10 microL of avian blood, suitable for RFLP analysis or hundreds of PCR amplifications. We compared our method to published procedures for alkaline extraction from feather pulp and found our method to be more reliable with the advantage of isolating intact DNA sequences that can be easily quantified. With minor modifications, the method can isolate DNA for PCR genotyping from mammalian whole blood.

Animals↗