The structure and dynamics of patch-clamped membranes: a study using differential interference contrast light microscopy.

We have developed techniques for micromanipulation under high power video microscopy. We have used these to study the structure and motion of patch-clamped membranes when driven by pressure steps. Patch-clamped membranes do not consist of just a membrane, but rather a plug of membrane-covered cytoplasm. There are organelles and vesicles within the cytoplasm in the pipette tip of both cell-attached and excised patches. The cytoplasm is capable of active contraction normal to the plane of the membrane. With suction applied before seal formation, vesicles may be swept from the cell surface by shear stress generated from the flow of saline over the cell surface. In this case, patch recordings are made from membrane that was not originally present under the tip. The vesicles may break, or fuse and break, to form the gigasealed patch. Patch membranes adhere strongly to the wall of the pipette so that at zero transmural pressure the membranes tend to be normal to the wall. With transmural pressure gradients, the membranes generally become spherical; the radius of curvature decreasing with increasing pressure. Some patches have nonuniform curvature demonstrating that forces normal to the membrane may be significant. Membranes often do not respond quickly to changes in pipette pressure, probably because viscoelastic cytoplasm reduces the rate of flow through the tip of the pipette. Inside-out patches may be peeled from the walls of the pipette, and even everted (with positive pressure), without losing the seal. This suggests that the gigaseal is a distributed property of the membrane-glass interface.

Animals↗

Early endostatin treatment inhibits metastatic seeding of murine colorectal cancer cells in the liver and their adhesion to endothelial cells.

Endostatin, a carboxy-terminal fragment of collagen XVIII, potently inhibits angiogenesis and tumour growth, presumably through induction of apoptosis in endothelial cells and/or inhibition of their migration. Here we have tested how the timing of recombinant human endostatin (rh-E) administration affects its antitumour activity in a liver metastasis model of mouse C26 colorectal carcinoma cells. The effects of rh-E treatment on hepatic tumour load and on early tumour cell seeding were evaluated. Recombinant human endostatin was most effective in reducing intrahepatic tumour growth when administered prior to tumour cell inoculation. Analysis of early tumour cell seeding by using [(125)I]iododeoxyuridine-labelled C26 cells or by in vivo microscopy showed that rh-E reduced tumour cell seeding in the liver sinusoids. Recombinant human endostatin did not inhibit tumour growth when administered later than 4 days after tumour injection. Pretreatment of human umbilical vein endothelial cells with rh-E in vitro reduced C26 tumour cell adhesion under flow conditions two-fold as assessed by video microscopy and multiphoton laser scanning microscopy. Our results show that rh-E, in addition to antiangiogenic effects, reduces tumour cell adhesion in the liver sinusoids during the very early phases of metastasis formation. These data point towards a previously unknown mode of action of endostatin, that is, its ability to interfere with tumour cell seeding. Such insights may be helpful in the design of trials to improve (surgical) treatment of colorectal carcinoma and liver metastases.

Animals↗

A new video image analysis system to study red blood cell dynamics and oxygenation in capillary networks.

OBJECTIVE: The authors present a Measurement and Analysis System for Capillary Oxygen Transport (MASCOT) to study red blood cell (RBC) dynamics and oxygenation in capillary networks. The system enables analysis of capillaries to study geometry and morphology and provides values for capillary parameters such as diameter and segment length. It also serves as an analysis tool for capillary RBC flow characteristics, including RBC velocity, lineal density, and supply rate. Furthermore, the system provides a means of determining the oxygen saturation of hemoglobin contained within RBCs, by analysis of synchronized videotapes containing images at two wavelengths, enabling the quantification of the oxygen content of individual RBCs. METHODS: Video recordings of RBC flow at two wavelengths, 420 nm (isosbestic) and 436 nm (oxygen sensitive), are made using a dual camera video microscopy system. The 420-nm recording is used to generate images based on the variance of light intensity fluctuations that help to identify capillaries in a given field of view that are in sharp focus and exhibit flow of individual RBCs separated by plasma gaps. A region of interest enclosing the desired capillary is defined and a fixed number of successive video frames at the two wavelengths are captured. Next a difference image is created, which delineates the RBC column, whose width is used to estimate the internal diameter of the capillary. The 420-nm images are also used to identify the location and centroid of each RBC within the capillary. A space-time image is generated to compute the average RBC velocity. Lineal density is calculated as the number of RBCs per unit length of a capillary segment. The mean optical density (OD) of each RBC is calculated at both wavelengths, and the average SO(2) for each cell is determined from OD(436)/OD(420). RESULTS AND CONCLUSIONS: MASCOT is a robust and flexible system that requires simple hardware, including a SGI workstation fitted with an audio-visual module, a VCR, and an oscilloscope. Since the new system provides information on an individual cell basis from entire capillary segments, the authors believe that results obtained using MASCOT will be more accurate than those obtained from previous systems. Due to its flexibility and ease of extension to other applications, MASCOT has the potential to be applied widely as an analysis tool for capillary oxygen transport measurements.

Animals↗

Contribution of microscopy to a better knowledge of the biology of Giardia lamblia.

Giardia lamblia is a flagellated protozoan of great medical and biological importance. It is the causative agent of giardiasis, one of the most prevalent diarrheal disease both in developed and third-world countries. Morphological studies have shown that G. lamblia does not present structures such as peroxisomes, mitochondria, and a well-elaborated Golgi complex. In this review, special emphasis is given to the contribution made by various microscopic techniques to a better knowledge of the biology of the protozoan. The application of video microscopy, immunofluorescence confocal laser scanning microscopy, and several techniques associated with transmission electron microscopy (thin section, enzyme cytochemistry, freeze-fracture, deep-etching, fracture-flip) to the study of the cell surface, peripheral vesicles, endoplasmic reticulum-Golgi complex system, and of the encystation vesicles found in trophozoites and during the process of trophozoite-cyst transformation are discussed.

Animals↗

Intravital microscopy of the peripheral lymph node microcirculation in mice.

OBJECTIVE: The purpose of this study was to develop a model for microscopic in situ observation of the murine peripheral lymph node (LN) microcirculation and to characterize the function of the lymphocyte homing receptor L-selectin (CD62L) and the peripheral node addressin (PNAd). The latter is a high-affinity ligand for L-selectin in LN high endothelial venules (HEV). METHODS: The subiliac (superficial inguinal) LN was microsurgically dissected in anesthetized adult mice. The nodal microvascular architecture and venular hemodynamics were characterized by bright field and epifluorescence video microscopy. L1-2 pre-B cells that were either mock transfected (L1-2Vector) or stably transfected to express human L-selectin (L1-2L-selectin) were labeled fluorescently and injected into a feeding artery. Cell adhesion in LN venules was studied in both the presence and absence of neutralizing monoclonal antibodies (MAb) to PNAd and L-selectin. RESULTS: The preparation allowed a detailed analysis of hemodynamic parameters and leukocyte adhesion in LN microvessels. L1-2Vector cells did not interact with LN microvessels. In contrast, L1-2L-selectin cells rolled efficiently in venules but not in arterioles or capillaries. Rolling was most prominent in subcortical HEV (orders III to V) and was less frequent but consistently detectable in downstream medullary and hilus venules (orders I and II). Rolling interactions were abrogated by MAb DREG-56 to the lectin domain of L-selectin and were markedly reduced by the anti-PNAd MAb MECA-79. CONCLUSIONS: The present study develops a new intravital microscopy model for in vivo visualization of leukocyte interactions with microvessels in murine LN. The preparation permitted an analysis of biophysical and molecular mechanisms of leukocyte adhesion to high endothelial cells. The data support the concept that L-selectin and PNAd are the predominant receptor/ligand pair responsible for lymphocyte rolling in HEV. The model will be useful for high-resolution analysis of intra- and extravascular events in living LN.

Animals↗

Myosin II can be localized to the cleavage furrow and to the posterior region of Dictyostelium amoebae without control by phosphorylation of myosin heavy and light chains.

To elucidate the role of phosphorylation in regulation of intracellular distribution of myosin II, we have characterized mutant Dictyostelium cells expressing myosin II that could not be regulated by the phosphorylation on the mapped heavy chain sites, the light chain site, or both sites. Immunofluorescence microscopy demonstrated that all three mutant myosin IIs were localized in the furrow region of dividing cells and in the tail region of migrating cells, similar to wild-type cells. Thus, regulation by phosphorylation is not required to direct myosin II toward the furrow region and the tail region in Dictyostelium. However, myosins that were deficient in heavy chain phosphorylation were distributed only in the cortical region of interphase cells, whereas some myosin IIs were present throughout the endoplasm in wild-type cells. Video microscopy showed that the rate of cell migration was significantly lower in cells that were deficient in heavy chain phosphorylation- than in light chain phosphorylation-deficient cells, myosin null cells and wild-type cells. Chemotactic behavior of cells that were deficient in heavy chain phosphorylation was also retarded. These results suggest that loss of regulation by heavy chain phosphorylation results in excessive myosin in the cortex, which leads to retarded motility.

Animals↗

Space Station Biological Research Project (SSBRP) Cell Culture Unit (CCU) and incubator for International Space Station (ISS) cell culture experiments.

The CCU and Incubator are habitats under development by SSBRP for gravitational biology research on ISS. They will accommodate multiple specimen types and reside in either Habitat Holding Racks, or the Centrifuge Rotor, which provides selectable gravity levels of up to 2 g. The CCU can support multiple Cell Specimen Chambers, CSCs (18, 9 or 6 CSCs; 3, 10 or 30 mL in volume, respectively). CSCs are temperature controlled from 4-39 degrees C, with heat shock to 45 degrees C. CCU provides automated nutrient supply, magnetic stirring, pH/O2 monitoring, gas supply, specimen lighting, and video microscopy. Sixty sample containers holding up to 2 mL each, stored at 4-39 degrees C, are available for automated cell sampling, subculture, and injection of additives and fixatives. CSCs, sample containers, and fresh/spent media bags are crew-replaceable for long-term experiments. The Incubator provides a 4-45 degrees C controlled environment for life science experiments or storage of experimental reagents. Specimen containers and experiment unique equipment are experimenter-provided. The Specimen Chamber exchanges air with ISS cabin and has 18.8 liters of usable volume that can accommodate six trays and the following instrumentation: five relocatable thermometers, two 60 W power outlets, four analog ports, and one each relative humidity sensor, video port, ethernet port and digital input/output port.

Automation↗

Quantitative, video-based histochemistry to measure regional effects of anticholinesterase pesticides in rat brain.

Acetylcholinesterase histochemistry was coupled to inexpensive and widely available apparatus for video microscopy and densitometry to study enzyme activity and inhibition in different parts of the rat brain. Quantitative histochemistry, under properly defined conditions, yielded an output that increased linearly with incubation time and section thickness and was a smooth hyperbolic function of substrate concentration. The time-course of staining after in vivo exposure to eserine revealed no sign that carbamate-induced cholinesterase inhibition was readily reversed in vitro. Brains from rats treated either with a carbamate or an organophosphate anticholinesterase pesticide showed significant regional variation in cholinesterase inhibition. The histochemical data corresponded well with data from biochemical assays of acetylcholinesterase activity (overall correlation coefficient of absolute values, r = 0.95). Also, a comparison of assay types by two-way analysis of variance showed no significant main effect. These results support the conclusion that video-based histochemistry is suitable for detailed studies of developmental and toxicological influences on cholinesterases in multiple microscopic regions of the rat brain.

Animals↗

Structure of growing microtubule ends: two-dimensional sheets close into tubes at variable rates.

Observation of microtubule growth at different rates by cryo-electron microscopy reveals that the ends range from blunt to long, gently curved sheets. The mean sheet length increases with the growth rate while the width of the distributions increases with the extent of assembly. The combination of a concentration dependent growth rate of the tubulin sheet with a variable closure rate of the microtubule cylinder, results in a model in which stochastic fluctuations in sheet length and tubulin conformation confine GTP-tubulins to microtubule ends. We propose that the variability of microtubule growth rate observed by video microscopy (Gildersleeve, R. F., A. R. Cross, K. E. Cullen, A. P. Fagen, and R. C. Williams. 1992. J. Biol. Chem. 267: 7995-8006, and this study) is due to the variation in the rate of cylinder closure. The curvature of the sheets at the end of growing microtubules and the small oligomeric structures observed at the end of disassembling microtubules, indicate that tubulin molecules undergo conformational changes both during assembly and disassembly.

Animals↗

Virus-induced cell motility.

Many viruses induce profound changes in cell metabolism and function. Here we show that vaccinia virus induces two distinct forms of cell movement. Virus-induced cell migration was demonstrated by an in vitro wound healing assay in which infected cells migrated independently into the wound area while uninfected cells remained relatively static. Time-lapse microscopy showed that the maximal rate of migration occurred between 9 and 12 h postinfection. Virus-induced cell migration was inhibited by preinactivation of viral particles with trioxsalen and UV light or by the addition of cycloheximide but not by addition of cytosine arabinoside or rifampin. The expression of early viral genes is therefore necessary and sufficient to induce cell migration. Following migration, infected cells developed projections up to 160 microm in length which had growth-cone-like structures and were frequently branched. Time-lapse video microscopy showed that these projections were formed by extension and condensation of lamellipodia from the cell body. Formation of extensions was dependent on late gene expression but not the production of intracellular enveloped (IEV) particles. The requirements for virus-induced cell migration and for the formation of extensions therefore differ from each other and are distinct from the polymerization of actin tails on IEV particles. These data show that poxviruses encode genes which control different aspects of cell motility and thus represent a useful model system to study and dissect cell movement.

Animals↗

Effects of verapamil on daunomycin cellular retention and cytotoxicity in P388 leukemic cells.

We have utilized digitized video microscopy to investigate the influence of verapamil, a calcium channel blocker, on the in vitro effects of daunomycin in P388 sensitive and resistant sublines. In this study, verapamil enhanced the uptake of daunomycin and its cytotoxicity in both sublines, but the effect was more pronounced in the resistant cells. Flow cytometry showed a pronounced accumulation of resistant cells at G2-M when treated with daunomycin in the presence of verapamil, with no effects observed in the absence of verapamil. Analysis of individual resistant cells using the digitized video fluorescence microscopy technique demonstrated that the influence of verapamil on daunomycin uptake affected all cells and was not restricted to certain subpopulations of cells.

Animals↗

Flow velocity of cutaneous lymphatic capillaries in patients with primary lymphedema.

For the first time measurements of lymph flow velocities in cutaneous microlymphatics of patients with lymphedema were performed and compared with healthy subjects. Flow velocity in single lymphatic skin capillaries was measured using fluorescence video microscopy after subepidermal microinjection of FITC-dextran 150,000 in 15 healthy volunteers and 16 patients with primary lymphedema. Initial filling of the lymphatic capillary network was fast with significantly higher mean velocities in patients with primary lymphedema than in healthy controls (890 +/- 43 vs. 550 +/- 390 microns/s, p < 0.05). The resting velocities were not significantly different between controls and patients (10.3 +/- 4.1 vs. 16.6 +/- 13.9 microns). In 12 out of the 16 lymphedema patients cutaneous backflow of the fluorescent contrast medium from deeper invisible lymphatics was observed. In 4 of these patients rhythmic reflux with a mean frequency of 1.4 +/- 0.5 cycles/min was measured by video densitometry in microlymphatics with a significantly (p < 0.01) enhanced diameter. Mean flow velocity (Vp) in these precollectors was significantly increased compared to the resting velocities (p < 0.01). On the basis of these results the hypothesis is advanced that rhythmic cutaneous backflow originates from intrinsic contractions of deeper lymph collector segments and is transmitted to the superficial microlymphatics through incompetent connecting channels. This newly recognized mechanism appears to be an important factor for the pathophysiology of lymphedema.

Adult↗

Digital motion analysis as a tool for analysing the shape and performance of the circulatory system in transparent animals.

The analysis of perfusion parameters using the frame-to-frame technique and the observation of small blood vessels in transparent animals using video microscopy can be tedious and very difficult because of the poor contrast of the images. Injection of a fluorescent probe (fluorescein isothiocynate, FITC) bound to a high-molecular-mass dextran improved the visibility of blood vessels, but the gray-scale histogram showed blurring at the edges of the vessels. Furthermore, injection of the fluorescent probe into the ventricle of small zebrafish (Danio rerio) embryos (body mass approximately 1 mg) often resulted in reduced cardiac activity. Digital motion analysis, however, proved to be a very effective tool for analysing the shape and performance of the circulatory system in transparent animals and tissues. By subtracting the two fields of a video frame (the odd and the even frame), any movement that occurred within the 20 ms necessary for the acquisition of one field could be visualised. The length of the shifting vector generated by this subtraction, represented a direct measure of the velocity of a moving particle, i.e. an erythrocyte in the vascular system. By accumulating shifting vectors generated from several consecutive video frames, a complete trace of the routes over which erythrocytes moved could be obtained. Thus, a cast of the vascular system, except for those tiny vessels that are not entered by erythrocytes, could be obtained. Because the gray-scale value of any given pixel or any given group of pixels increased with the number of erythrocytes passing it, digital motion analysis could also be used to visualise the distribution of blood cells in transparent tissues. This method was used to describe the development of the peripheral vascular system in zebrafish larvae up to 8 days post-fertilisation. At this stage, food intake resulted in a clear redistribution of blood between muscle tissue and the gut, and alpha-adrenergic control of peripheral blood flow was established.

Anguilla↗

A correlation-based approach to calculate rotation and translation of moving cells.

We present a noniterative image cross-correlation approach to track translation and rotation of crawling cells in time-lapse video microscopy sequences. The method does not rely on extracting features or moments, and therefore does not impose specific requirements on the type of microscopy used for imaging. Here we use phase-contrast images. We calculate cell rotation and translation from one image to the next in two stages. First, rotation is calculated by cross correlating the images' polar-transformed magnitude spectra (Fourier magnitudes). Rotation of the cell about any center in the original images results in translation in this representation. Then, we rotate the first image such that the cell has the same orientation in both images, and cross correlate this image with the second image to calculate translation. By calculating the rotation and translation over each interval in the movie, and thereby tracking the cell's position and orientation in each image, we can then map from the stationary reference frame in which the cell was observed to the cell's moving coordinate system. We describe our modifications enabling application to nonidentical images from video sequences of moving cells, and compare this method's performance with that of a feature extraction method and an iterative optimization method.

Algorithms↗

Natural color scanning electron microscopy based on the frequency characteristics of the human visual system.

The principles of image formation in natural color scanning electron microscopy (NC-SEM) are discussed in detail. This method is based on the frequency characteristic of the human visual system. It is shown that the Mach effect and masking effect are important in the characteristics. The former, which can enhance structural details, is visually similar to the edge effect in secondary electron (SE) images, and the latter is required for proper representation of very degraded color information obtained from a light microscope. When using these effects suitably, an NC-SEM image with the resolution equivalent to that of an SEM image can be acquired, though it is composed of an SEM image and a special video microscopy (VM) image with a resolution much lower than the SEM image of the identical view. The NC-SEM is more effective than the SEM in observation. interpretation, and analysis of various samples with important color information.

Color↗

Computer-assisted morphometry of cell-substratum contacts.

AIM: Quantitative analysis of size and shape of the cell-substratum contacts in Dictyostelium and comparison of these parameters between wild-type cells and the cells bearing cytoskeletal protein mutations. METHODS: Reflection interference contrast microscopy (RICM) was used to image the areas of contact between aggregation-competent Dictyostelium cells and weakly adhesive mica surfaces. The cell-substratum contact areas were automatically identified in RICM micrographs by digital image processing. Information about the size and shape of the contact areas was obtained by using the shape descriptors based on two-dimensional geometrical moment invariants. RESULTS: Lack of either of the two actin-crosslinking proteins, a-actinin and 120 kDa gelation factor, similarly affects the cell-substratum interactions of Dictyostelium cells. The shape descriptors, elongation and dispersion, of the contact areas were reduced by 10% to 30% in mutant cells when compared to the wild type, but the size of the contacts was not affected. CONCLUSION: Video microscopy combined with digital image processing and quantitative image analysis is capable of revealing small phenotypic effects of cytoskeletal protein mutations on the level of single cells. Such automated microscopic methods are expected to gain importance and find a widespread use in biomedicine.

Actinin↗

Morphology and physiology of neurons in the rat perirhinal-lateral amygdala area.

Neuronal structure-function relationships were studied in rat brain slices containing the perirhinal cortex (PR) and immediately adjacent lateral nucleus of the amygdala (ALa). Using video microscopy, whole-cell recordings were made from visually preselected neurons that were labeled with biocytin for subsequent anatomical reconstructions. Most cells were 1 of 4 primary neurophysiological types: fast-spiking (FS), regular-spiking (RS), late-spiking (LS), and burst-spiking (BS). Fast-spiking neurons (small somata) were found throughout PR; RS neurons (stellates and pyramids) were present from layer II/III through VI of PR; BS neurons (large pyramids with thick nonbifurcating apical dendrites) were found in layer Va of PR; and LS neurons (stellates, small pyramids, and cone cells) were encountered in layers II/III and VI of PR. One subpopulation of LS neurons (small pyramids) was found in layer II/III; another (cone cells) was found in clusters spanning layer VI through the lateral portion of ALa. Layer Va also contained large RS pyramidal neurons whose axons were seen traveling in the external capsule, but not entering the ALa. Conversely, the axons of large RS pyramidal neurons in layer Vb typically projected deep into the ALa. The four primary firing patterns were present in ALa, which also contained irregular-spiking, slow-charging, and single-spiking cells. Spontaneous synaptic currents differed markedly among cell types and layers. There was excellent agreement between somatic areas measured from video images of living neurons and somatic areas from the same neurons following fixation. Representative montages, which combined the cellular neuroanatomy and neurophysiology, suggested a circuit-level organization that helps elucidate information processing through the PR-ALa region.

Amygdala↗

Methods of stretching DNA molecules using flow fields.

Using fluorescence microscopy, we compare the degree of adsorption and stretching of DNA onto surfaces achieved by published stretching methods that use fluid flow: molecular combing, spin-stretching, and air-blowing. Molecular combing uses a receding meniscus to stretch out and deposit the DNA onto a hydrophobic surface. In spin-stretching, we find that the effect of radial hydrodynamic flow created by the centrifugal force of the rotating disk is minimal and that the DNA is stretched out on a hydrophobic substrate by the moving meniscus. In air-blowing, a jet of gas pushes liquid across a substrate, depositing stretched DNA molecules along the way. In our study, DNA molecules either combed or spin-stretched onto hydrophobic surfaces stretch to a greater degree than those that are air-blown; fewer are deposited at pH 8.0 than at lower pH, apparently because at pH 8.0 DNA adhesion occurs primarily only at the DNA extremities and so avoids trapped regions of incompletely stretched DNA, with the side effect that more molecules avoid adhesion altogether. We find by high-speed video microscopy that there is complex droplet deformation and motion during air-blowing, which complicates the deposition and stretching process, leading to radial alignment. Our results are a first step toward understanding and optimizing the various proposed methods of DNA stretching and anchoring onto surfaces, which is important in studying their interactions with proteins.