Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MICROWAVES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37Linked to original sources

Microwave continuous sterilization of injection ampoules.

A new microwave continuous sterilizer (MWS) for applying microwave dielectric heating as an alternative to an autoclave was developed. The developmental objectives of the MWS were: 1. Achieving sufficient sterilization for the drugs containing heat-sensitive ingredients. 2. Measuring and recording sterilization temperature of each ampoule. 3. Ensuring automatic continuous operation and linkage with the preceding and following machines in an injection ampoule production process. The temperature of the drug solution in an ampoule was heated to 140 degrees C within about 30 seconds by the MWS. Target F0 value is achieved through the maintaining heater to maintain the target temperature for 12 seconds. Ampoules are cooled with air and water after completion of heating. The MWS is capable of processing 150 ampoules per minute. The newly developed techniques which minimized temperature distribution of heated ampoule solution were: 1. Microwave irradiation in a direction opposite to the direction of ampoules transportation. 2. Microwave irradiation in the lower part of ampoule solution (i.e., heating up the drug solution by thermal convection.) 3. Microwave power control by feedback of measured temperatures. 4. Heating rate control corresponding to the dielectric property of ampoule solution. The drug stability test was performed using 3% pyridoxamine phosphate solution, and the inactivation of spores in 3% pyridoxamine phosphate solution was examined using Bacillus stearothermophilus ATCC 7953 spores. The MWS was proved to have an adequate efficiency of sterilization with less chemical degradation of the contents than an autoclave.

Drug Stability↗

Effect of microwave oven heating times on androgen receptor antigen retrieval from paraffin-embedded prostatic adenocarcinoma.

The aim of this study was to investigate the effect of microwave oven heating for antigen retrieval on the immunoreactivity of human prostate carcinoma androgen receptor (AR) in tissue sections. Formalin-fixed, paraffin-embedded tissue sections were microwaved at 5-min intervals for a total of 15, 20, 25, 30, 35 minutes at maximum power (700W). The monoclonal antibody F39.4.1 directed against human AR was used at a 1:10 dilution. Without microwave oven heating, prostatic tissue did not exhibit any AR immunoreactivity. Moderate positivity appeared after three 5-minute cycles of microwave heating. The intensity of immunoreactivity improved progressively with heating times of 20 and 25 min up to an optimum time of 30 minutes, when nuclear staining was most intense with the absence of background staining and without loss of morphological details. While antigen retrieval is effective in restoring antigenicity in a variety of setting, the length of time prostate tissue is exposed to microwave radiation is critical in order to obtain optimal AR immunostaining. AR immunostaining reliably permitted evaluation of the distribution and intensity of positively stained nuclei and the distinction of the various cell types in archival material.

Adenocarcinoma↗

[Reaction of the brain receptor system to the effect of low intensity microwaves].

We have found that two important brain synaptic receptor systems are very sensitive to the influence of low intensity microwaves. Both the excitatory glutamatergic and the inhibitory GABAergic are affected by microwave exposure. Power densities higher 50 microW/cm2 caused changes in the binding properties of these receptors to agonists. Low frequence modulation of microwaves was essential for these effects. Statistically significant effects on mean value of binding were observed at 16 Hz modulation. Exposure to microwave radiation changes the binding of agonists to glutamate and GABA receptors in different ways. An increase was observed for glutamate and a decrease for GABA. We suppose that the effect of microwaves is related to the stress reactions of the organism.

Animals↗

Use of the Microwave-Assisted Process in extraction of fat from meat, dairy, and egg products under atmospheric pressure conditions.

Fat from meat, dairy, and egg products was extracted by using Microwave-Assisted Process (MAP) technology under atmospheric pressure conditions. Fat content was determined gravimetrically after extraction with microwaves and organic solvents that are transparent to microwaves relative to the sample. (In situ hydrolysis was performed for dairy and egg products.) Fat from the food sample migrated completely to the extractant when samples were irradiated with focused microwave for a total of 3 min for meat products, 1 min for dairy products, and 4 min for egg products. Unlike current methods used for determining fat in meat products, the microwave-assisted method does not require a dry sample, because moisture in the sample (around 75%) enhances the efficiency of extraction. No preprocessing was required for meat samples other than homogenization, which is critical, as it is for other current methods. In addition to speed and ease of use, the features of this technology are low solvent consumption, low energy consumption, reproducibility, and recoveries similar to or even better than those of conventional extraction methods.

Atmospheric Pressure↗

[Use of a microwave device for dental instrument sterilization: possibilities and limitations].

BACKGROUND: The aim of the present study was the evaluation of the effectiveness as sterilizer of a modified version of a microwave device, which was previously tested by the same authors and found unsatisfactory. MATERIALS AND METHODS: Dental mirrors were contaminated by 10(4)-10(9) microorganisms of Stapbylococcus aureus and spores of Bacillus subtilis and Bacillus stearothermophilus. The inocula used were both wet and dry. The duration of the treatment was 4 minutes. Three series of tests were made: 1) microwaves and "adjuvant" solution (as suggested by the producer of the device); 2) microwaves only (in place of the "adjuvant" solution, a Na Cl 0.9% was used); 3) "adjuvant" solution only (into an oven at 25 degrees C). RESULTS: In the 1st and 3rd series of tests all the microorganisms and the spores were killed. In the 2nd series of tests a bactericidal effect against some, not all, microorganisms of the S. aureus species and against spores of B. subtilis and B. stearothermophilus was found. CONCLUSIONS: The results of this study suggest that the device tested has a sterilizing activity, which, however, is not due to the activity of microwaves only; but to the combined activity of microwaves, "adjuvant" solution and temperature (since inside the device, at the end of the treatment the temperature on the mirrors was 94 degrees C).

Dental Instruments↗

Application of microwave tissue coagulator in partial nephrectomy for renal cell carcinoma.

PURPOSE: At partial nephrectomy there is a risk of excessive blood loss, which necessitates transfusion and also results in renal function deterioration when a vascular clamp is used. We evaluated the usefulness of a microwave tissue coagulator for partial nephrectomy for renal cell carcinoma. MATERIALS AND METHODS: Partial nephrectomy was performed without renal pedicle clamping using a microwave tissue coagulator in 4 patients with a small kidney tumor. RESULTS: In 3 of the 4 patients partial nephrectomy was successful using a microwave tissue coagulator without renal pedicle clamping. Mean operative time and blood loss were 203 minutes and 153 ml., respectively, and there were no significant complications. In the remaining case partial kidney resection was also performed without any complications. However, nephrectomy was required due to possible incomplete tumor resection. CONCLUSIONS: Partial nephrectomy using a microwave tissue coagulator can be safe and successful without renal pedicle clamping. However, the insertion line of the microwave electrode must be carefully determined for resection to be curative and safe, just as when making the cut line for conventional partial nephrectomy or tumor enucleation.

Adult↗

A modified design of microwave tissue coagulator monopolar antenna for applications in laparoscopic hepatic surgery.

Massive hemorrhage is of primary concern during hepatic surgery. In this study, we not only modified the monopolar antenna of the microwave tissue coagulator but also investigated its feasible applications in laparoscopic hepatic surgery. In addition, the conventional antenna of the microwave tissue coagulator was used as a model. A catheter was attached to the antenna. The network analyzer was used to analyze the impedance of the novel monopolar antenna. Moreover, we designed and constructed a novel monopolar antenna for the microwave tissue coagulator. The antenna is gas-leak-proof, having sufficient stiffness and length and retaining similar microwave emission strength, pattern, and shielding property as the conventional antenna. In vitro tests in porcine liver confirm the coagulation and hemostatic effects of the novel type laparoscopic monopolar antenna. Results presented herein confirm the effectiveness of a laparoscopic monopolar antenna for a microwave tissue coagulator with sufficient coagulation effects.

Animals↗

A comparison of bond strengths of soft denture liners to polymethyl methacrylate polymerized by conventional water bath and microwave curing techniques.

This study compared the tensile bond strengths of soft lining materials polymerized by using conventional water bath methods and microwave energy. The soft lining materials used in this investigation were heat temperature vulcanizing (H.T.V.) silicon material Molloplast-B, and room temperature vulcanizing (R.T.V) acrylic material Getz Soft Oryl. The H.T.V. specimens were prepared with retention, additional retention and without retention, and the R.T.V. specimens were prepared by using bonding agent and bonding agent plus retention. All were cured by both conventional water bath and microwave energy. Results showed that the mean bond strength of H.T.V. specimens ranged from 9.6 to 13.12 kg/cm2, while the mean bond strength of R.T.V. specimens ranged from 0.36 to 1.75 kg/cm2. In both conventional and microwave groups, the specimens prepared with retention, additional retention and without retention or using bonding agent and bonding agent plus retention did not show any significant difference when they were compared separately. But the difference between conventional and microwave groups was found significant in both H.T.V. and R.T.V. specimens. It showed that conventional water bath technique is better than microwave technique.

Acrylic Resins↗

[Clinical application of ischemic microwave coagulation therapy for malignant liver tumor].

By means of ischemic coagulation of the hepatic artery and portal vein in a microwave coagulation experiment of in vivo swine [correction of bovine] liver, we confirmed approximate doubling of the coagulation diameter compared to the usual coagulation. Based on this fact, for treatment of patients with metastatic liver tumor, we developed an ischemic percutaneous microwave tumor coagulation method using IVR method and applied it in one case, and performed laparotomy microwave tumor coagulation in three cases. We performed the ischemic percutaneous microwave tumor coagulation method on one of the cases. Coagulation was performed for one minute at a dose of 100 W for treatment of metastatic liver tumor of 2 cm in diameter via laparotomy. The postoperative CT showed an extensive coagulation larger than 3 cm. A 2 cm liver tumor was coagulated under balloon ischemia of the hepatic vein and hepatic artery for 13 minutes at a dose of 60 W. The maximum coagulation diameter was 5 cm. Extensive coagulation was possible with percutaneous microwave tumor coagulation through ischemia.

Animals↗

Thin-layer liquid crystal thermometry of cells in vitro during hyperthermal microwave irradiation.

A nonperturbing technique of thin-layer liquid crystal thermometry was developed to quantitate heating of Chinese hamster ovary cells and the bacterium Serratia marcescens when exposed to 2450-MHz microwave fields at 0.2-0.5 W/cm2. Cells suspended in culture medium were injected into 5-cm glass microcapillary tubes coated on the inside with a thin layer of liquid crystal. The tubes were sealed and placed parallel to the electric field in a watertight waveguide exposure chamber where they were heated by circulating temperature-controlled water. Even at high circulation rates, liquid crystal color changes indicated local microwave capillary tube heating of 0.1-0.25 degrees C. Precision of measurement was 0.02 degrees C. Observations during microwave heating were significantly different from observations without microwaves at the 1% level, and heating increased as circulating water flow was reduced from 300 ml/s to 100 ml/s. The results of a cell survival assay following hyperthermal treatment were in good agreement with expectations based on the observations of microwave heating using liquid crystals.

Animals↗

Microwave synthesis of hybrid inorganic-organic porous materials: phase-selective and rapid crystallization.

Microwave synthesis of two porous nickel glutarates was compared with conventional hydrothermal synthesis. The cubic nickel glutarate, [Ni20(C5H6O4)20(H2O)8] x 40 H2O (1), was synthesized by conventional electrical heating in several hours or days, depending on synthesis temperature. Crystallization was greatly accelerated by microwave irradiation, in which more stable, tetragonal nickel glutarate, [Ni22(C5H6O4)20(OH)4(H2O)10] x 38 H2O (2), was formed within a few minutes, suggesting the efficiency of the microwave technique in the synthesis of porous hybrid materials. The cubic phase 1 is formed preferentially at low pH, low temperature, and especially under conventional electrical heating. In contrast, the tetragonal phase 2 is obtained favorably at high pH, high temperature, and especially with microwave irradiation. This work demonstrates that the microwave method provides not only the very fast synthesis of a hybrid material, but also the possibility to discover a new porous hybrid material not yet identified by conventional hydrothermal synthesis. The hydrothermal formation of metal-organic hybrid materials in a matter of minutes is an important step towards developing commercially viable routes for producing this valuable class of materials.

Journal Article↗

Electrically detected magnetic resonance signal intensity at resonant frequencies from 300 to 900 MHz in a constant microwave field.

A method for electrically detected magnetic resonance (EDMR) measurement at different ESR frequencies under a constant alternating magnetic field has been established wherein the accurate relationship between EDMR signal intensity (from a photoexcited silicon crystal and a silicon diode) and a resonant frequency of 300 to 900 MHz (UHF band) was systematically clarified. EDMR signal intensity from a photoexcited silicon crystal against a resonant frequency fitted the curve of y = a(1 - e(-bx)) well, which approached a constant value at higher frequencies. The increase in the EDMR signal intensity from the silicon diode at higher resonant frequencies was smaller than that from the photoexcited silicon crystal. The difference can be explained by the influence of the skin effect; i.e., the microwaves do not penetrate deep into a highly conductive sample at higher frequencies. EDMR signal intensities of samples vs microwave power were measured at 890 MHz. The EDMR signal intensity from the silicon diode continued to increase as the microwave power was increased, while the signal intensity from the photoexcited silicon crystal saturated within the range. The difference can be similarly explained: due to the skin effect, the microwaves gradually penetrate into the silicon diode as the power increases, so that even when saturation has been reached outside, the microwave field inside the diode does not reach the saturation level.

Electricity↗

High-Resolution Microwave and Infrared Molecular-Beam Studies of the Conformers of 1,1,2,2-Tetrafluoroethane.

High-resolution microwave and infrared molecular-beam spectra have been measured for 1,1,2,2-tetrafluoroethane (HFC134). For the higher energy, polar, C2 symmetry, gauche conformer, microwave spectra have been recorded for the normal and mono-13C isotopomers and analyzed to determine a C-C bond length of 1.512(4) Å, in good agreement with a recent ab initio value (MP2/6-31G**) of 1.515 Å [S. Papasavva, K. H. Illinger, and J. E. Kenny, J. Phys. Chem. 100, 10100-10110 (1996)]. A tunable microwave-sideband CO2 laser and electric-resonance optothermal spectrometer have been used to measure the infrared spectrum of the nu6, C-C stretch of the gauche conformer near 906 cm-1. Microwave-infrared double resonance and precise ground state combination differences provided by the microwave measurements guide the assignment of the spectrum. The observation of a c-type spectrum definitively establishes that the upper state vibration is of A symmetry in the C2 point group. The spectrum is fit to a Watson asymmetric-top Hamiltonian to a standard deviation of 0.24 MHz. A weak perturbation shifts the line positions for transitions near J = Kc = 20 by as much as 12 MHz. The identity of the perturber is unknown. Pulsed slit-jet diode-laser spectra have been recorded for the nu16 vibration of the anti conformer near 1127 cm-1. An a- and c-type hybrid band is observed, consistent with a Bu symmetry mode. Previous low-resolution studies have attributed the 1127-cm-1 mode to either a Bu or an Au symmetry vibration. A total of 522 nonblended transitions were assigned and fit to determine ground and excited state constants. The ground state constants of A = 5134.952(65) MHz, B = 3148.277(27) MHz, and C = 2067.106(43) MHz are the first experimental determinations of the rotational constants for this conformer. Here, type A standard uncertainties are given in the parentheses. Copyright 1998 Academic Press.

Journal Article↗

Investigation of the species-specific degradation behaviour of methylmercury and ethylmercury under microwave irradiation.

The degradation behaviour of methylmercury (MeHg) under microwave irradiation is investigated, as is the (different) degradation behaviour of ethylmercury (EtHg) under similar irradiation. A simple and highly sensitive SPME-GC-pyrolysis-AFS system was used to analyse the aqueous MeHg and EtHg standard solutions after derivatization with sodium tetraphenylborate (NaBPh(4)). Samples were irradiated in a microwave digester at microwave powers ranging from 20 to 160 W for durations of 2 to 10 min. The different tolerances towards microwave treatment of the two organomercury species were evident. Practically no degradation was experienced for MeHg for up to 8 minutes of irradiation at 120 W or for up to 4 minutes at 160 W. Significant analyte loss was observed for EtHg after 2 minutes at 40 W of microwave power.

Journal Article↗

Intraseptal microinjection of beta-funaltrexamine blocked a microwave-induced decrease of hippocampal cholinergic activity in the rat.

Acute (45 min) exposure to pulsed (2 microseconds pulse width, 500 pulses per second) 2450-MHz microwaves at a power density of 1 mW/cm2 (whole body specific absorption rate 0.6 W/kg) microwaves caused a decrease in cholinergic activity in the hippocampus of the rat as measured by the sodium-dependent high-affinity choline uptake. Microinjection of beta-funaltrexamine (1 microgram) into the septum before microwave exposure blocked this effect. These data indicate that mu-opioid receptors in the septum mediate a microwave-induced decrease in cholinergic activity in the hippocampus and support our hypothesis that microwaves at a whole body SAR of 0.6 W/kg can activate endogenous opioids in the brain.

Animals↗

Transurethral microwave thermotherapy for management of benign prostatic hyperplasia: results of the United States Prostatron Cooperative Study.

The primary objective of the study was to determine the safety and efficacy of transurethral microwave thermotherapy for the treatment of symptomatic benign prostatic hyperplasia. From March to August 1991, 150 patients were entered into a multi-site study and treated with transurethral microwave thermotherapy under a Food and Drug Administration approved protocol. Only patients with symmetrical trilobar or bilobar prostatic hypertrophy, peak flow rate of less than 15 cc per second (on 2 voided volumes of 150 cc or greater) and a total Madsen symptom score of more than 8 were treated. Transurethral microwave thermotherapy was performed with a 20F catheter and 1,296 MHz. microwave antenna for 60 minutes. The mean power achieved for this single session was 32.1 watts, with a mean power at maximum urethral temperature of 41.1 watts. Mean urethral temperature was 44.3C and the mean rectal temperature was 42.2C. The rectal and urethral temperatures were continuously monitored. Mean peak urinary flow rates, Madsen symptom score, post-void residual volume and improvement in motivating symptom to seek treatment were measured at 6 weeks, and 3, 6 and 12 months. Mean peak urinary flow rates improved 33% at 12 months (p < 0.0001). Overall, the mean Madsen symptom score improved 61% (p < 0.0001). The obstructive score and the irritative score improved 67% and 43%, respectively. Of 17 patients 12 (71%) reported improvement in weak stream when that was the motivating symptom to seek treatment. Of 28 men 18 (64%) reported improvement in nocturia, while 11 of 30 (37%) reported improvement in daytime frequency and 12 of 17 (71%) reported improvement in urgency. There was no statistically significant difference in post-void residual volume at 12 months from baseline. The treatment was well tolerated by all patients, and side effects were considered mild and transitory. Our study demonstrates the safety, effectiveness, patient tolerability and durability of transurethral microwave thermotherapy.

Adult↗

Development and evaluation of a glow discharge microwave-induced-plasma tandem source for time-of-flight mass spectrometry.

In this work, a new glow discharge, microwave-induced-plasma (GDMIP), tandem ion source was developed, characterized, and used in conjunction with time-of-flight mass spectrometry. This tandem source was designed to be simple and compact The GD and the MIP unit are independent and demountable, providing flexibility in tuning and operating. The microwave plasma can be formed with very low power (a few watts) and overlapped with the glow discharge. The discharge current increased with the addition of microwave discharge when the GD was operated in constant-voltage mode, and the amplitude of the current increase was found to be related to microwave power, discharge pressure, and sampling distance. With the addition of microwave discharge, significant signal enhancement was achieved under a discharge pressure of 2.0 Torr and a discharge voltage of 500 V with 2.0-mm sampling distance. Enhanced factors of analyte signals ranging from approximately 1 to nearly 10 could be obtained with MIP boosting, while no significant change in noise level was observed. This new tandem source provides improved performance in direct solid sample analysis.

Journal Article↗

Use of microwave-assisted evaporation for the complete recovery of volatile species of inorganic trace analytes

Solutions must often be evaporated prior to analysis either to preconcentrate the analyte or to eliminate an incompatible matrix component. Elimination of the halogen-based acids HCI and HF using traditional evaporation methods poses recovery problems because of volatilization of the target analyte as the chloride or fluoride species. A new sample preparation chemistry for trace analysis, where losses of analyte due to volatilization during the evaporation process are minimized, is explored using the unique heating mechanisms of the microwave-assisted evaporation process. The heating mechanisms of hot plate evaporation and microwave-assisted evaporation are compared, and temperatures throughout the evaporation process using each method are predicted and experimentally verified. Because the solution actually cools during microwave-assisted evaporation, volatilization due to overheating at dryness is minimized. Elemental standard solutions and SRM soil and tissue digestates were evaporated using a hot plate method and a newly developed reduced-pressure microwave-assisted evaporation apparatus. Redissolution and analysis of the residue by ICPMS showed that complete recovery was achieved using microwave-assisted evaporation while losses of several classically volatile analytes occurred using hot plate evaporation.

Journal Article↗