Can the average glandular dose in routine digital mammography screening be reduced? A pilot study using revised image quality criteria.

There is a need for tools that in a simple way can be used for the evaluation of image quality related to clinical requirements in mammography. The aim of this work was to adjust the present European image quality criteria to be relevant also for digital mammography images, and to use as simple and as few criteria as possible. A pilot evaluation of the new set of criteria was made with mammograms of 28 women from a General Electric Senographe 2000D full-field digital mammography system. One breast was exposed using the standard automatic exposure mode, the other using about half of that absorbed dose. Three experienced radiologists evaluated the images using visual grading analysis technique. The results indicate that the new quality criteria can be used for the evaluation of image quality related to clinical requirements in digital mammography in a simple way. The results also suggest that absorbed doses for the mammography system used may be substantially reduced.

Aged↗

Missed breast cancer in an augmented woman using implant displacement mammography.

Good mammography in the augmented patient is often difficult to achieve. A case is described that illustrates that posterior breast tissue is generally better seen with standard compression mammography and that physical examination by the radiologist must accompany mammography. Implant displacement mammography, while helpful, does not eliminate the need for standard compression mammography in selected patients.

Aged↗

Mammography quality assurance in Washington State.

Poor mammography quality control results in the loss of important diagnostic information. Several organizations and agencies recommend or require that mammography quality assurance procedures include the periodic evaluation of equipment. The objective of this study was to assess compliance with published guidelines pertaining to the monitoring of mammography equipment. One hundred eighty-four Washington state mammography facilities were surveyed by mail during late 1989 and early 1990. The response rate was 71%. A large proportion of facilities was not complying with published guidelines concerning the frequency of evaluation of processor parameters and phantom image quality. Results suggest that many facilities were not in compliance with American College of Radiology recommendations concerning annual system evaluation by a physicist. The results of this study reinforce the importance of establishing minimum quality assurance standards and indicate a need for more mammography quality assurance technologist training.

Equipment and Supplies↗

Patterns of health services utilization and mammography use among women aged 50 to 59 years in the Québec Medicare system.

Many studies have identified physicians' recommendation as the single most important predictor of mammography use. Health services utilization is a complex phenomenon, and the contribution of the different dimensions of health services utilization on mammography use is underresearched. This study examines the specific contribution of health services utilization variables in a multivariate model of the recency of mammography use for women aged 50 to 59 years. Subjects were respondents of the 1987 Québec Health Survey. Survey data were then linked on an individual basis to the respondent's records of Medicare physicians' claims for health care services for the 3 years before the survey. This unique data set enabled the inclusion of sociodemographic variables, risk factors, health status, healthy lifestyles, and women's patterns of utilization of general and gynecologic health care services. Multivariate predictors of the recency of mammography are: having an education higher than high school, working outside home, not living in a remote area, suffering from benign breast disease, and not perceiving one's own health as good. The volume of general and gynecologic medical care is associated with the recency of mammography in independent logistic models that include women's predisposing, enabling, and need factors. This study shows that even in a universal third-party payer health care system, physicians are missing opportunities to promote breast cancer screening.

Female↗

Mammography of the postreconstruction breast.

Experience with mammographic examination of the reconstructed breast after mastectomy is limited. Typical mammographic changes associated with breast reconstruction are described. When these changes are identified on mammography, they can prevent patients from having unnecessary biopsies and can alleviate patient anxiety. A retrospective review of all mammograms performed in our breast center was made to identify typical as well as unusual findings on the postreconstruction mammogram. The findings were correlated with the type of reconstruction and the physical examination findings. Mammography after mastectomy and breast reconstruction was performed in patients with palpable abnormalities, a suspicion for implant failure, or for patient anxiety. In the postreconstruction patient with a palpable mass, features characteristic of fat necrosis were the most frequent abnormal findings on mammography. Unusually placed implants or focal implant ruptures may explain a mass discovered on breast physical examination. Imaging of the reconstructed breast after mastectomy yields typical mammographic findings. Fat necrosis can be identified on mammography and may explain a new palpable mass on physical examination. Mammography continues to be useful to identify a postoperative complication or implant failure and to differentiate it from tumor recurrence.

Adult↗

Silicone breast implant rupture: pitfalls of magnetic resonance imaging and relative efficacies of magnetic resonance, mammography, and ultrasound.

The objective of this study was to evaluate the relative efficacies of magnetic resonance (MR) imaging, ultrasonography, and mammography in implant rupture detection and to illustrate pitfalls in MR image interpretation. Thirty patients referred by plastic surgeons with suspected breast implant rupture were prospectively evaluated using MR, ultrasonography, and mammography. Imaging examinations were interpreted independently and blindly for implant rupture and correlated to operative findings. Surgical correlation in 16 patients (53 percent) with 31 implants showed 13 (42 percent) were intact, 5 (16 percent) had severe gel bleed, and 13 (42 percent) were ruptured. MR sensitivity was 100 percent and specificity was 63 percent. Accuracy for rupture was 81 percent with MR, higher than with ultrasonography and mammography (77 and 59 percent, respectively). We describe a specific pitfall in MR interpretation, the "rat-tail" sign, composed of a medial linear extension of silicone along the chest wall. Seen in eight cases (four intact, three ruptures, one gel bleed), the rat-tail sign may lead to misdiagnosis of implant rupture if seen in isolation. Magnetic resonance imaging is more accurate and sensitive than ultrasonography and mammography in detecting breast implant rupture. We describe a new sign (rat-tail sign) composed of medial compression of the implant simulating silicone extrusion as a potential false-positive MR finding for rupture. This article presents clinical experience with magnetic resonance, mammography, and ultrasound in the diagnosis of implant rupture and defines and illustrates potential pitfalls of MR interpretation, including the new rat-tail sign.

Adult↗

Rationales for attending or not attending mammography screening--a focus group study among women in Sweden.

Quantitative findings regarding factors that affect attendance in population-based outreach mammography programmes need to be complemented by descriptive data. The aim of this study was to obtain descriptive insights into the meanings that Swedish women attach to mammograms and their rationales for attending or not attending mammography screening. For this purpose a total of 31 women were recruited to eight focus group discussions. Through inductive analysis, six main themes were identified as important issues in reasoning about attendance or non-attendance in mammography screening: negative experiences, perceived risk factors, knowledge of one's own body, perceived problems with mammography, political, ideological and moral reasoning, and involuntary non-attendance, due to the inability of the screening programme to cover some women (e.g. those with breast implants). In conclusion, there is a need to reinforce the information that mammography is an examination aiming at detecting lumps at an asymptomatic stage. However, the nature and amount of information the women themselves desire is inconsistent. Furthermore, the personal encounter between the individual woman and the staff seems to be of particular importance. An improved dialogue appears an attractive way of adapting the screening situation to meet the varied needs and expectations of the women who are invited.

Adult↗

Variability in women's desire for information about mammography screening: implications for informed consent.

This study aimed to explore women's desire for information about mammography screening in a population where overly optimistic perceptions of mammography screening were common. A self-administered questionnaire was completed by 2305 women aged 50-69 years, residents of Geneva, Switzerland. The questionnaire assessed the respondents' wish to receive information (detailed, general or none) about seven aspects of mammography screening: personal risk of breast cancer, prevention of breast cancer, benefits of mammography screening, limitations, minor inconveniences, more important problems, why some people oppose screening. The seven items formed a unidimensional scale (Cronbach's alpha=0.91). Women differed considerably in their stated desire for detailed or general information. For instance, whereas 14% wanted detailed information on all items and 36% general information on all items, 39% were not interested in detailed information on the limits and adverse consequences of screening. In multivariate analysis, some women's characteristics were associated with higher scores of desire for information, but little variance was explained (adjusted R=0.05). In conclusion, many women currently decline information about mammography screening that is deemed relevant by public health authorities. This may lead to poorly informed choices in an important area of prevention.

Age Factors↗

Current status of digital mammography for screening and diagnosis of breast cancer.

PURPOSE OF REVIEW: Digital mammography is becoming the preferred technique for investigation of the breast. It is important, therefore, to analyze not only the accuracy of this technique in the screening and the diagnostic environment but also to evaluate its strengths and limits. In addition, communication with other specialists inside and outside the hospital is essential. RECENT FINDINGS: Recent publications of large clinical trials have shown that digital mammography is as accurate as film-screen mammography in a screening setting. Technical protocols for acceptance testing of these modalities are emerging but they are not yet complete. The literature shows that reading on soft copy may be preferred to hard copy. The high cost is still an important limiting factor in the easy introduction of full-field digital mammography in a hospital. SUMMARY: Digital mammography is becoming the method of choice in the detection and characterization of breast cancer. Today, physical and technical protocols as well as large clinical trials are assessing the performance of this technology. A lot of work remains in the optimization of the different parts of the imaging chain: exposure setting, acceptability of detectors, dedicated post processing, viewing conditions and computer-aided detection. In parallel with these developments, newer digital technologies are being explored (tomosynthesis).

Breast Neoplasms↗

Characterization of benign and malignant breast lesions with computed tomography laser mammography (CTLM): initial experience.

OBJECTIVES: The aim of this study was to characterize benign and malignant breast lesions with computed tomography-laser mammography (CTLM). MATERIALS AND METHODS: In a prospective study, 100 female patients with 105 breast lesions classified as BIRADS IV to V at mammography underwent mammography, CTLM, and histologic verification at our institution. CTLM images were analyzed by radiologists with knowledge of the lesion's position but who were blinded to histology and morphologic findings from mammography. Two radiologists independently evaluated whether there was increased absorption, a sign of malignancy, on CTLM and assessed the appearance (volumes or linear branching) and shape (round or irregular) of the lesions. RESULTS: Histologic analysis revealed 55 benign (52.4%) and 50 malignant (47.6%) breast lesions. Increased absorption was observed significantly more often in malignant than in benign lesions (70.0% vs. 32.7%, P = 0.028). Invasive cancer showed increased absorption in 76.2%, and ductal carcinoma in situ in 37.5%. Common morphologic characteristics of increased absorption were "volumes" (85.7% of malignant and 77.8% of benign lesions) with round shape (78.1% of malignant and 73.3% of benign lesions). CONCLUSION: Our data indicate that CTLM, when used as an adjunct to mammography, may provide additional information to characterize benign and malignant breast lesions.

Adolescent↗

Comparison of false negative rates among breast cancer screening modalities with or without mammography: Miyagi trial.

False negative rates were compared in two screening modalities, physical examination with or without mammography, in an intervention study for women aged over 50 in Miyagi Prefecture. Thirty-five breast cancers were detected in 12,515 subjects who participated in the trial consisting of physical examination and mammography, whereas 44 breast cancers were detected in 50,105 subjects who received physical examination alone, so that the detection rates were 0.28% and 0.09%, respectively. Among 50,061 subjects who received physical examination alone, 8 women were diagnosed as having breast cancer within 12 months after the screening, while only one of 12,480 screenees receiving the combined modality was so diagnosed, implying false negative rates of 15.4% and 2.8%, respectively. When the screening sensitivity in the combined system was analyzed according to each single modality, the false negative rate provided by physical examination with mammography turned out to be 2.8%, significantly lower than that (33.3%) by the physical examination alone. Minimal breast cancers represented 25.7% of all screen-detected cancers in the combined modality, compared with 9.1% in the modality without mammography. The trial thus indicates that physical examination combined with mammography may be an appropriate modality for breast cancer screening in women aged over 50 on the basis of screening sensitivity.

Aged↗

Moving beyond the typologies of managed care: the example of health plan predictors of screening mammography.

OBJECTIVES: To develop a framework of factors to characterize health plans, to identify how plan characteristics were measured in a national survey, and to apply our findings to an analysis of the predictors of screening mammography. DATA SOURCE: The primary data were from the 1996 Medical Expenditure Panel Survey. STUDY DESIGN: Women ages 40+, with private insurance, and no history of breast cancer were included in the study (N = 2,909). We used multivariate logistic regression to estimate mammography utilization in the past two years relative to health plan and demographic factors. Health plan measures included whether there is a defined provider network, whether coverage is restricted to a network, use of gatekeepers, level of cost containment, copayment and deductible amounts, coinsurance rate, and breadth of benefit coverage. PRINCIPAL FINDINGS: We found no significant difference in reported mammography utilization using a dichotomous comparison of individuals enrolled in managed care versus indemnity plans. However, women in health plans with a defined provider network were more likely to report having received a mammogram in the past two years than those without networks (adjusted OR= 1.21, 95 percent CI = 1.07-1.36), and women in gatekeeper plans were more likely to report receiving mammography than those without gatekeepers (adjusted OR = 1.18, 95 percent CI = 1.03-1.36). Restricted out-of-network coverage, use of cost containment, enrollee cost sharing, and breadth of benefit coverage did not appear to affect mammography use. CONCLUSIONS: It is important to examine the effect of individual health plan components on the utilization of health care, rather than use the traditional broader categorizations of managed versus nonmanaged care or simple health plan typologies.

Adult↗

The use of mammography by women aged 75 and older: factors related to health, functioning, and age.

BACKGROUND AND OBJECTIVES: Mammographic screening for breast cancer is of uncertain clinical benefit for women 75 years of age and older. Some have argued against instituting routine screening in this age group, noting that disability and shorter life expectancy may diminish the desirability and cost-effectiveness of screening. We sought to determine the extent to which health, functioning, and age influence mammography use in this cohort. DESIGN, SETTING, AND PARTICIPANTS: A retrospective cohort study of a representative sample of women in the US aged 75 and older (n = 2352) who participated in the Medicare Current Beneficiary Survey. MEASURES: Information about general health, level of functioning, medical history, age, and various sociodemographic characteristics elicited in the survey was linked with subjects' Medicare bills for 1991 and 1992 to ascertain patterns of mammography use. RESULTS: Overall, 26.7% of the women had mammograms during the 2-year period. Advanced age was associated with a decreased likelihood of receiving a mammogram. This did not reflect simply the decline in health and functioning that may accompany aging; those aged 85 and older were less likely to receive mammograms than those in the 75 to 79 age group, controlling for general health, medical history, functional status, and sociodemographic factors (adjusted OR = .41; 95% CI = 0.27 to 0.64). ADL limitations were also associated independently with decreased mammography use. For example, controlling for age, women with any limitations in Activities of Daily Living were 0.71 times as likely to have mammograms as women without ADL limitations (95% CI = 0.59 to 0.85). However, several comorbid conditions, including hypertension, diabetes mellitus, and a history of myocardial infarction were not significantly related to mammography use. CONCLUSIONS: Within the cohort of women aged 75 and older, more advanced age and impaired functional status both substantially reduce the likelihood of mammography use. The extent to which this reflects patients' informed decisions, physicians' judgments, or other factors remains to be explored.

Activities of Daily Living↗

Performance of combined clinical mammography and needle biopsy: a nationwide study from Denmark.

Clinical mammography and needle biopsy are key tools for non-operative assessment of breast lesions. We evaluated the performance of all combined tests undertaken in Denmark in 2000. Clinical mammography and needle biopsy data were collected and linked to final cancer outcome, to determine sensitivity, specificity, and predictive values of clinical mammography, needle biopsy, and combined test. In 2000, 6709 combined tests were performed in 36 mammography clinics in Denmark. The combined test was consistently more sensitive than any single test, increasing the proportion of women correctly identified with breast cancer by 9% compared with clinical mammography alone. For concordant combined tests (i.e. either both benign or both malignant), specificity and positive predictive value were 100%, sensitivity was 99.1%, and positive predictive value was 99.6%. Therefore, Danish patients with a malignant concordant combined test can proceed directly to definitive surgery without fear of a false-positive diagnosis, and Danish women with a concordant benign combined test can omit surgery without fear of a false-negative diagnosis. In discordant cases, our results showed that any of the two tests with a suspicious or malignant result indicated a high risk of cancer, and excisional diagnostic biopsy therefore still has an important role to play.

Adult↗

Initial and repeat mammography screening: different behaviors/different predictors.

Despite evidence of the efficacy of mammography in early detection of breast cancer, many women choose not to have a mammogram. Some women who have an initial mammogram do not return for a second one. Many others, especially minority women, and those who live in rural areas or in a low socioeconomic class, are not being screened according to recommended guidelines. The full benefits of early detection are available only if women receive regular screening. This study of 830 randomly selected women over age 50 from rural, eastern North Carolina included women who had never had a mammogram (213), women who had had a mammogram but not in the prior 2 years (89), and women who reported having had a mammogram in the previous 2 years (528). Logistic regression was used to identify significant mammography predictor variables. The results support the robust role that provider recommendation plays in encouraging mammography behavior; they also demonstrate that past behavior is also a strong predictor of future screening participation. Only 13% of the women who had never had a mammogram reported obtaining a referral from their provider compared with 79% of the women who had a mammogram in the previous 2 years. Likewise, 75% of the women who had engaged in mammography behavior in the prior 2 years expressed a positive intention to be screened in the next year compared with only 14% of those women who had never had a mammogram. Initial and repeat mammography screenings are different behaviors and are influenced by different factors. For provider counseling to be effective, the strategies employed need to consider past behavior as well as current recommendations, and they must incorporate a discussion of beliefs as well as reinforcement of regular screening behavior.

Aged↗

Quality control for digital mammography: part II. Recommendations from the ACRIN DMIST trial.

The Digital Mammography Imaging Screening Trial (DMIST), conducted under the auspices of the American College of Radiology Imaging Network (ACRIN), is a clinical trial designed to compare the accuracy of digital versus screen-film mammography in a screening population [E. Pisano et al., ACRIN 6652-Digital vs. Screen-Film Mammography, ACRIN (2001)]. Part I of this work described the Quality Control program developed to ensure consistency and optimal operation of the digital equipment. For many of the tests, there were no failures during the 24 months imaging was performed in DMIST. When systems failed, they generally did so suddenly rather than through gradual deterioration of performance. In this part, the utility and effectiveness of those tests are considered. This suggests that after verification of proper operation, routine extensive testing would be of minimal value. A recommended set of tests is presented including additional and improved tests, which we believe meet the intent and spirit of the Mammography Quality Standards Act regulations to ensure that full-field digital mammography systems are functioning correctly, and consistently producing mammograms of excellent image quality.

Breast↗

A computer simulation study comparing lesion detection accuracy with digital mammography, breast tomosynthesis, and cone-beam CT breast imaging.

Although conventional mammography is currently the best modality to detect early breast cancer, it is limited in that the recorded image represents the superposition of a three-dimensional (3D) object onto a 2D plane. Recently, two promising approaches for 3D volumetric breast imaging have been proposed, breast tomosynthesis (BT) and CT breast imaging (CTBI). To investigate possible improvements in lesion detection accuracy with either breast tomosynthesis or CT breast imaging as compared to digital mammography (DM), a computer simulation study was conducted using simulated lesions embedded into a structured 3D breast model. The computer simulation realistically modeled x-ray transport through a breast model, as well as the signal and noise propagation through a CsI based flat-panel imager. Polyenergetic x-ray spectra of Mo/Mo 28 kVp for digital mammography, Mo/Rh 28 kVp for BT, and W/Ce 50 kVp for CTBI were modeled. For the CTBI simulation, the intensity of the x-ray spectra for each projection view was determined so as to provide a total average glandular dose of 4 mGy, which is approximately equivalent to that given in conventional two-view screening mammography. The same total dose was modeled for both the DM and BT simulations. Irregular lesions were simulated by using a stochastic growth algorithm providing lesions with an effective diameter of 5 mm. Breast tissue was simulated by generating an ensemble of backgrounds with a power law spectrum, with the composition of 50% fibroglandular and 50% adipose tissue. To evaluate lesion detection accuracy, a receiver operating characteristic (ROC) study was performed with five observers reading an ensemble of images for each case. The average area under the ROC curves (Az) was 0.76 for DM, 0.93 for BT, and 0.94 for CTBI. Results indicated that for the same dose, a 5 mm lesion embedded in a structured breast phantom was detected by the two volumetric breast imaging systems, BT and CTBI, with statistically significant higher confidence than with planar digital mammography, while the difference in lesion detection between BT and CTBI was not statistically significant.

Algorithms↗

Practical application of a scan-rotate equalization geometry to mammography.

The presence of dense fibroglandular tissue within the breast is the most significant cause of failure to detect breast cancer with mammography. The dense tissue often produces a range of exposure which exceeds the useful dynamic range of film-screen mammography. It has been shown that equalization radiography overcomes the latitude limitations of film-screen imaging. Equalization compensates for regional variations in x-ray transmission within the patient through spatial modulation of the entrance exposure. We have proposed rotary scanning equalization radiography (RSER), a scan-rotate geometry for efficient equalization radiography. In RSER the image receptor is exposed by repeated scans of a source-modulated fan beam. The fan beam is rotated with respect to the patient between scans. Numerical simulations and theoretical analysis have shown that the superposition of exposure from appropriately modulated fan beams at a variety of angles is an entrance exposure that effectively equalizes the film exposure. The design and characteristics of a prototype RSER imaging system are described. Anthropomorphic breast phantom images are used to determine the improvement in image contrast obtained with RSER, the expected tube loading, and the presence of artifacts. RSER increases the fraction of the breast imaged with high contrast (at least 90% of peak gradient) from 46% (conventional mammography) to 80%. Subjective examination of the phantom images show that RSER achieves image quality very similar to that of much less efficient equalization geometries with only 2.7 times greater tube loading than conventional mammography. As predicted by theoretical analysis of exposure artifacts in RSER, the prototype RSER system is relatively immune to artifacts. Exposure artifacts were demonstrated for extreme variations in x-ray transmission within the patient. These results show that RSER is an efficient, practical means of overcoming the latitude limitations of film-screen mammography, and improving the detection of breast cancer.

Biophysical Phenomena↗