Polyethylene failure in New Jersey low-contact stress total knee arthroplasty.

From January 1985 to December 1990, 598 consecutive New Jersey low-contact stress (LCS) total knee arthroplasties (TKAs) were performed for gonarthrosis. Among these 598 operations, 322 were with rotating platform elements and 276 were with meniscal bearing elements. During 5 to 8 years of follow-up, eight knees had severe symptomatic polyethylene failure that required revision surgery; all eight cases were meniscal bearing types. The failed polyethylene inserts were retrieved and studied. It was observed that there were four probable failure mechanisms associated with the catastrophic polyethylene wear. First, insufficient thickness of the meniscal bearing was the major reason for wear. Second, the malpositioning of the metal tibial tray in the transverse plane resulted in the breaking of the meniscal bearing. Third, the inability of the patellar to rotate due to tissue ingrowth made the polyethylene break. Last, yellowing of the subsurface of the meniscal bearing was a sign of polyethylene failure. These four possible failure mechanisms are all associated with the design of the meniscal bearing type of LCS knee prostheses. Therefore, it is suggested that the design of the LCS knee prosthesis should be modified.

Aged↗

Silent compartment syndrome complicating total knee arthroplasty: continuous epidural anesthesia masked the pain.

Posterior dislocation is an uncommon complication of total knee arthroplasty (TKA) using a posterior stabilized total knee prosthesis, and it usually results from flexion instability. Acute posterior dislocation of a posterior stabilized prosthesis complicated by compartment syndrome of the leg has not previously been reported in the literature. We report a 62-year-old woman with posterior dislocation of her posterior stabilized TKA when her knee was in extension. It was further complicated by compartment syndrome with severe muscle necrosis. The diagnosis of compartment syndrome was delayed, partly because of continuous epidural anesthesia that completely abolished the pain and partly because of the low index of suspicion, as compartment syndrome is not well recognized as a possible complication of TKA. This case report strongly emphasizes that continuous epidural anesthesia is contraindicated in the case of complicated TKA because important clinical cues to neurovascular complications could be masked.

Anesthesia, Epidural↗

Inherent laxity in total knee prostheses.

The anterior-posterior and rotatory laxities of 14 total knee prosthesis designs were measured in a loading rig with compressive, shear, and torque loads representative of physiologic loads. The measured laxities covered a wide range, both greater and smaller than that of the anatomic knee. This range was mainly due to the curvature or flatness of the plastic tibial surface and conformity with the femoral component. Pressure patterns showed the corresponding contact track and area on the tibial surfaces. It is proposed that for normal function, the laxity of the device should complement the remaining anatomic structures to produce a combined laxity resembling that of the normal knee. Excessive prosthetic laxity will lead to the risk of instability, soft tissue attenuation, edge-loading on components, and high contact stresses on the plastic. Inadequate prosthetic laxity may lead to altered kinematics and excessive stresses at the interface, running the risk of long-term loosening. The authors show the laxities of many currently used devices, providing important background information for assessing the role intrinsic prosthetic constraint might play in total joint performance in clinical analyses.

Biomechanical Phenomena↗

[Treatment of supracondylar femoral fracture proximal to a knee joint endoprosthesis by retrograde interlocking nailing].

A case of a supracondylar femoral fracture proximal to a total knee prosthesis is reported. This difficult fracture was managed with retrograde intramedullary locked nailing. The time to union was 6 weeks. Cancellous bone grafting was not necessary. At final follow up the patient had a knee score of 90 and a functional score of 80 points. This was equal to the result after joint replacement prior to the injury.

Aged↗

Articular cartilage echography as a criterion of the evolution of osteoarthritis of the knee.

We propose a modification of the Aisen's technique by which precise reproducible measurements of articular cartilage thickness of the knee is possible. A group of 23 patients with severe osteoarthritis was studied by ultra-sound (US) before knee prosthesis surgery. Evaluation with US was performed by a real-time scanner with a 7.5 MHz linear probe with upper-patellar transverse scans tangent to the upper patellar pole at 90 degrees knee flexion. The cartilage thickness was measured within the weight-bearing area. After surgery, on the corresponding gross pathological specimen, US re-evaluation and histological measurements were made. Results of pre- and post-operative ultrasonography (US) data were compared with histological data and a good correlation between these measurements was found (p(t) > 10%). Preoperative measurements ranged from 2.4 to 0.3 mm. In order to obtain normal reference values of the articular cartilage within the weight-bearing area of the femoral trochlea for comparison, a group of 10 control subjects was also studied with US as above. The US data were then compared with computed tomography (arthro-CT) evaluations. No significant differences in mean values were found between the two imaging techniques (2.2 mm versus 2.3 mm for the lateral condyle and 2.3 versus 2.3 for the medial condyle, respectively). We conclude that ultra-sound measurement of articular cartilage thickness of femoral condyles is a sensitive and reproducible technique which permits early diagnosis and management of knee arthropathy and also quantification of cartilage damage.

Adolescent↗

[Unicondylar knee arthroplasty with "Repicci" model].

Development of mini invasive techniques for implantation of unicondylar knee prostheses has increased general interest in this type of surgery. Indications are single compartment arthrosis, patients over 50 years of age with total body weight of less then 80 kg with small axis deviations and ligaments preserved. Important contraindications are systemic diseases. Authors present mid-term postoperative results for 25 patients and 26 knees after implantation of unicondylar knee prosthesis type Repicci. Average age at time of surgery was 64.3, predominantly women and in all patients varus deformity with medial compartment arthrosis was seen. According to the Ahlback classification patients were from type 1 to type 4. Average follow up was 31.8 months. We achieved good axial correction with femorotibial angle of 6.2 degrees postoperatively, with flexion of 118 degrees and only in 3 knees extension lag was seen of an average of 8.3 degrees. According to the Knee Society Questionnaire, knee score was 60 points preoperatively and 86.8 points postoperatively and functional score was 30.9 points preoperatively and 71.1 points postoperatively. Pain level, according to the Visual Analogue Scale, was preoperatively 6.8 points and 2 points postoperatively (10 was max). We conclude that the unicondylar knee arthroplasty is a good solution for patients with early degenerative changes in one knee compartment. This type of operative procedure will be more used because of numerous advantages when compared to other treatment options.

Aged↗

Total knee replacement using the stabilized gliding prosthesis.

The stabilized gliding knee prosthesis has been designed as a compromise between the restrained hinged joints and the unconnected surface prostheses. It is a two-piece implant, allowing normal gliding movements of flexion and extension, and is stabilized by a rod between the femoral and tibial components which allows some lateral mobility and rotation while acting in place of the cruciate ligaments and in place of or in addition to the collateral ligaments. The indications for and the techniwue of implantation are described and the results of the first 53 operations are reported. Follow-up time is between 1 year and 2 1/2 years. The results of these operations using the stabilized gliding prosthesis are at least equal to those using hinged or condylar prostheses. So far there has been no case of loosening of either component, and the implant can be used successfully in patients in whom condylar prostheses fail owing to their lac of inbuilt stability.

Age Factors↗

Cementless total knee arthroplasty in patients over 65 years old.

Many factors influence the decision to implant a knee prosthesis with or without cement. Implant retrieval studies have demonstrated that bone ingrowth into porous-coated devices is possible even in older age groups. Early clinical follow-up observations suggest that cementless total knee arthroplasty can be successful in patients over 65 years of age, and need not be reserved for younger patients.

Aged↗

Load transfer characteristics of a noncemented total knee arthroplasty.

This study evaluated load transfer characteristics of femoral and tibial components of a total knee prosthesis that was designed to achieve distal femoral and proximal tibial compressive load-bearing. Strain gauge readings were highest on the cortex of the tibial metaphyseal flare. Roentgenograms of 110 patients with noncemented total knee arthroplasty (TKA) with follow-up periods of 12-24 months were evaluated. Cancellous bone hypertrophy bridging from the undersurface of the tibial component to the metaphyseal cortical bone was noted on all roentgenograms at six months, suggesting stress transfer through cancellous bone to this area. Anterolateral sinking was noted in six of the first 46 patients but was not seen again in the series after a design change was made to more rigidly fix the stem in the bone of the upper tibia. Roentgenograms of the femoral components demonstrated distal bone hypertrophy suggesting compressive load bearing. None of the femoral components migrated or sank.

Bone Cements↗

Increased varus-valgus tilting of screw-fixated knee prostheses. Stereoradiographic study of uncemented versus cemented tibial components.

Twenty-six women and three men (34 knees) with osteoarthrosis were operated with the Miller-Galante I (Zimmer, Warsaw, IN) knee prosthesis. The patients were randomized to either cemented or uncemented fixation of the tibial component. All patients received a TiVaAl alloy tibial plate with four pegs and titanium fiber-mesh undersurface. In the uncemented knees four screws were added. The fixation of the tibial component was determined by roentgen stereophotogrammetric analysis during the first 2 postoperative years. Rotations of the entire tibial component were recorded, as well as proximal or distal translation of various parts of the prosthetic edge corresponding to subsidence and lift-off. The uncemented components displayed almost all rotation and translation during the first 6 weeks, whereas the cemented ones displayed a more gradually increasing migration during the 2 years. Tibial component rotation about the sagittal axis was significantly increased in the uncemented knees throughout the investigation period. This corresponded to increased subsidence medially or laterally in the uncemented knees, whereas lift-off was equal in the two groups. Thin (8.5 mm) uncemented tibial components displayed more subsidence than the thicker ones at the medial or lateral edge 3 months after surgery.

Aged↗

Muscular function and bone mass after knee arthroplasty.

We report a study of 28 women with severe primary gonarthrosis followed for 1 year. Variations in bone mineral density and in functional behaviour of knee extensors and flexors were studied before and after implantation of uncemented total knee prosthesis. A functional deficit was noted in the extensor apparatus, which increased in the first 6 months following surgery. This strength was not improved 1 year following the arthroplasty, but it was more efficient as shown by the reduction of muscle fatigue. Flexor strength was conserved and a pathological muscle balance was maintained, reaching maximum efficiency over a smaller joint range.

Aged↗

Aseptic synovitis.

We report the first case of aseptic synovitis that occurred after a titanium knee prosthesis failed. This complication should be considered when a patient with a titanium prosthesis develops tenderness, erythema, and swelling of that joint.

Aged↗

Condylar total knee arthroplasty after failed proximal tibial osteotomy.

Data were collected retrospectively on thirty-five patients who had a failed osteotomy of the proximal part of the tibia for unicompartmental osteoarthrosis of the knee that was treated with a cruciate condylar, total condylar, kinematic condylar, or cemented porous-coated anatomical total knee prosthesis. The patients were evaluated clinically and roentgenographically before and after the arthroplasty. The minimum period of follow-up was twenty-nine months (mean, forty-four months). On the basis of the knee-rating scale of The Hospital for Special Surgery, 89 per cent of the patients had either an excellent or a good result after the arthroplasty. No result was a failure. One patient had loosening of the patellar component, but no other loosening was identified. The results of total knee arthroplasty after osteotomy of the proximal part of the tibia were found to be comparable with the results after arthroplasty in knees that had not had a prior osteotomy. The intraoperative and postoperative rates of complications were not higher, and no untoward technical difficulties were encountered at surgery. These data support the clinical impression that an osteotomy of the proximal part of the tibia does not "burn any bridges" insofar as a future successful arthroplasty is concerned.

Adult↗

[Navigated implantation of total knee endoprostheses--a comparative study with conventional instrumentation].

OBJECTIVE: A navigation system should improve the quality of a total knee prosthesis implantation in comparison to the classical, surgeon-controlled operative technique. METHODS: The authors have implanted 40 knee total prostheses with an optical infrared navigation system (Orthopilot AESCULAP, Tuttlingen--group A). The quality of implantation was studied on postoperative long leg AP and lateral X-rays, and compared to a control group of 40 computer-paired total knee prostheses o the same model (Search Prosthesis, AESCULAP, Tuttlingen) implanted with a classical, surgeon-controlled technique (group B). RESULTS: An optimal mechanical femorotibial angle (3 degrees valgus to 3 degrees varus) was obtained by 33 cases in group A and 31 cases in group B (p > 0.05). Better results were seen for the coronal and sagittal orientation of both tibial and femoral components in group A. Globally, 26 cases of the group A and 12 cases of the group B were implanted in an optimal manner for all studied criteria (p < 0.01). CONCLUSIONS: The used navigation system allows a significant improvement of the quality of implantation of a knee total prosthesis in comparison to a classical, surgeon-controlled instrumentation. Long-term outcome could be consequently improved.

Arthroplasty, Replacement, Knee↗

The influence of surgical malalignment on the contact pressures of fixed and mobile bearing knee prostheses--a biomechanical study.

OBJECTIVE: To investigate the effect of surgical malalignment on contact pressures of fixed and mobile bearing knee prostheses. DESIGN: An experimental set-up was used to measure contact pressure on the tibial component of fixed and mobile bearing knee prostheses subjected to a compression load and surgical malalignment situations were simulated. BACKGROUND: Mobile bearing knee prostheses were designed to decrease tibiofemoral contact pressure by providing both high congruity and mobility. It was also assumed to accommodate surgical malalignment. However, few studies have reported the effect of malalignment of the tibiofemoral joint on contact pressure of fixed and mobile bearing knee prostheses. METHODS: Surgical malalignment situations were simulated to evaluate contact characteristics of tibial component of fixed and mobile bearing knee prostheses. The simulated malalignment conditions include the medial-lateral translation (0.5 and 1 mm), anterior-posterior translation (2 and 4 mm) and internal-external rotation (1 degrees, 3 degrees, 5 degrees and 10 degrees ) of the femoral component relative to the tibial component. Fuji pressure sensitive film was used to measure the contact pressure. RESULTS: The greatest increase of maximum contact pressure in the anterior-posterior maltranslation was 7.63% and 7.62% relative to the neutral contact situation in the fixed and mobile bearing designs respectively. In the medial-lateral maltranslation, there was 23.3% in the fixed bearing design and was 22.0% in the mobile bearing design. In the internal/external malrotation, the greatest increase of maximum contact pressure in the fixed bearing design was 27.1%, which was much higher than the mobile bearing design (22.4%). CONCLUSIONS: The mobile bearing design can reduce maximum contact pressure more significantly than the fixed bearing design when malalignment conditions of the tibiofemoral joint occurs, especially in the internal/external malrotation. The mobile bearing design offers the advantage of self-adjusting over the fixed bearing design to accommodate surgical malalignment. RELEVANCE: This study revealed that the mobile bearing design has smaller maximum contact pressures than the fixed bearing design in knee prosthesis under malalignment biomechanical tests. This result indicates that there is an advantage for a mobile bearing design over a fixed bearing design to accommodate malalignment conditions caused by surgical technique or soft tissues imbalance in total knee arthroplasty.

Arthroplasty, Replacement, Knee↗

Medium term outcome of the LCS cementless posterior cruciate retaining total knee replacements. Follow up and survivorship study of 35 operated knees.

Mobile bearing knee replacement has been designed to provide an effective prosthetic tool for improving long-term survivorship. Although, its potential long-term superiority has not been proven, an alarming possibility of its early mechanical failure has been previously reported. In the present study on 27 patients with 35 replaced knees due to osteoarthritis, 97.1% of a 5-year survivorship of LCS mobile bearing cementless total knee prosthesis is reported. This high survival rate, with a satisfactory functional outcome at middle term follow-up has been achieved by following an optimal technique of implantation. Therefore, in the middle term this mobile bearing design of total knee replacement is no less effective than the conventional fixed bearing designs.

Aged↗

Adaptation of NASA technology for the optimum design of orthopedic knee implants.

NASA technology originally developed for designing aircraft turbine-engine blades has been adapted and applied to orthopedic knee implants. This article describes a method for tailoring an implant for optimal interaction with the environment of the tibia. The implant components are designed to control stresses in the bone for minimizing bone degradation and preventing failures. Engineers expect the tailoring system to improve knee prosthesis design and allow customized implants for individual patients.

Aerospace Medicine↗

Alumina versus polyethylene in total knee arthroplasty.

The cementless alumina total knee prosthesis, which uses alumina in the portions coming in contact with the bone and a combination of alumina and ultra-high molecular-weight polyethylene (UHMWPE) in the sliding portions, is referred to as a total condylar. Alumina total knee arthroplasty was performed on 137 patients, including 103 rheumatoid arthritis (RA) and 34 osteoarthrosis (OA) patients, from January 1982 to February 1985. The follow-up period was seven years 11 months and four years ten months, respectively. At follow-up evaluation, 108 patients were available for clinical and roentgenographic examinations, amounting to a 79% follow-up rate. At follow-up examination, 67 joints (62%) were completely pain free and 28 joints (26%) caused slight pain on bearing weight. Walking ability was recovered moderately in RA and markedly in OA. In RA, 14 of 84 knees were cemented and one knee was treated with loosening. Of 72 cementless implantations, 55 sustained displacing distally and one sustained loosening in the tibia, whereas 31 sustained displacing proximally and six sustained loosening in the femur. In OA, 21 cementless knees had 17 displacings in the tibia, and ten displacings and two loosenings in the femur. Scanning electron microscopy (SEM) observation of the UHMWPE surface in tibial plates revealed smoothing and burnishing. Alumina is far superior to metal for the sliding part, although it is not always best for the portion in contact with the bone. To resolve these problems, for cementless fixation, anchoring portions of Ti alloy and alumina implants were covered with beads and coated with hydroxyapatite. For cement fixation, "the interface bioactive bone cement technique" interposing hydroxyapatite granules between bone and cement was performed.

Adult↗