Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “INTERFEROMETRY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37Linked to original sources

Phase-contrast X-ray imaging based on interferometry.

Phase-contrast X-ray imaging including tomographic configuration using a crystal X-ray interferometer is reviewed. The imaging principle based on phase retrieval is described, and some demonstrations showing its high sensitivity are presented on the observations of animal and human cancerous tissues.

Animals↗

Two-dimensional visible synchrotron light interferometry for transverse beam-profile measurement at the SPring-8 storage ring.

A two-dimensional visible synchrotron light interferometer has been developed to measure the transverse profile of an electron beam at the SPring-8 storage ring. The new interferometer enables the simultaneous measurement of beam sizes along the major and minor axes and the beam-tilt angle of an assumed elliptical Gaussian distribution. The principle of the interferometer is explained through basic formulae. To calibrate the point-spread function of the interferometer, a simple error model was assumed for disturbances in the amplitude and phase of the light; these disturbances were presumably caused by optical elements, such as mirrors and lenses. The experimental method to determine the parameters in the error model is shown. To verify the two-dimensional profiling capabilities of the interferometer, an electron beam stored in the SPring-8 storage ring operated at various working points was observed. A beam broadening from 20 to 120 microm in the vertical direction and changes in the beam-tilt angle were clearly observed at working points close to the differential resonance. However, the vertical spatial resolution is limited by the available vertical separation of the apertures of the diffracting mask because of the narrow aperture of the upstream vacuum duct.

Journal Article↗

Ultrasonic interferometry for the measurement of shear velocity and attenuation in viscoelastic solids.

A method for the measurement of the shear properties of solid viscoelastic materials is presented. The viscoelastic material is cut into a cylindrical sample which is clamped between two rods. The transmission and reflection coefficient spectra of the fundamental torsional mode through the sample are measured by means of two pairs of piezoelectric transducers placed at the free ends of the rod-sample-rod system. Such spectra exhibit maxima and minima which occur approximately at the resonance frequencies of the free viscoelastic cylinder. Therefore, the shear velocity can be obtained by measuring the frequency interval between two consecutive maxima or minima. The shear attenuation is derived by best fitting the analytical expression of the reflection and transmission coefficients to the experimental spectra. The test is very quick to set up as the sample is simply clamped between the two rods.

Journal Article↗

Migration of fluids beneath yellowstone caldera inferred from satellite radar interferometry

Satellite interferometric synthetic aperture radar is uniquely suited to monitoring year-to-year deformation of the entire Yellowstone caldera (about 3000 square kilometers). Sequential interferograms indicate that subsidence within the caldera migrated from one resurgent dome to the other between August 1992 and August 1995. Between August 1995 and September 1996, the caldera region near the northeast dome began to inflate, and accompanying surface uplift migrated to the southwest dome between September 1996 and June 1997. These deformation data are consistent with hydrothermal or magmatic fluid migration into and out of two sill-like bodies that are about 8 kilometers directly beneath the caldera.

Journal Article↗

Tributaries of West Antarctic Ice Streams Revealed by RADARSAT Interferometry.

Interferometric RADARSAT data are used to map ice motion in the source areas of four West Antarctic ice streams. The data reveal that tributaries, coincident with subglacial valleys, provide a spatially extensive transition between slow inland flow and rapid ice stream flow and that adjacent ice streams draw from shared source regions. Two tributaries flow into the stagnant ice stream C, creating an extensive region that is thickening at an average rate of 0.49 meters per year. This is one of the largest rates of thickening ever reported in Antarctica.

Journal Article↗

Contacts of chick fibroblasts on glass: results and limitations of quantitative interferometry.

We have examined the contacts made by explanted chick heart and limb bud fibroblasts after 24-48 h on glass, using quantitative interference reflection microscopy (IRM). Contacts beneath very thin cytoplasmic lamellae were avoided because the images of such contacts depend on the thickness of the lamellae. Plaque-like focal contacts, distinguished on the basis of shape and low irradiance (darkness), are intimate adhesions to the substratum. These images can be interpreted if it is assumed that microfilaments associated with the lower membrane increase the local cytoplasmic refractive index. The range of irradiances measured for focal contacts was found to be rather wide, and our modelling shows that the most likely explanation for this is that the images receive variable contributions from the adjacent cytoskeleton. For this reason it is particularly difficult to assign a characteristic thickness for these contacts from IRM data. Close contacts, seen principally as 'grey' regions under migrating cells at the edges of the explants, also show a wide range of irradiances. Unlike focal contacts, it is not necessary to postulate any involvement of the cytoskeleton in their images and they can be modelled as regions where an aqueous glycocalyx zone about 20-30 nm thick separates the membrane bilayer from the glass. Paler grey regions that also look like close contacts are apparently formed where the cell surface has lifted several tens of nanometres from the glass.

Animals↗

Mueller matrix error correction for a fringe-free interferometry system.

We present an automated surface profiling system based on a shearing interferometer, in which precise measurement of the polarization states eliminates fringe ambiguity. A full error correction based on Mueller matrices allows comparatively inaccurate but rapidly switchable liquid-crystal wave plates to be used, enabling unambiguous profile information to be obtained in real time.

Journal Article↗

Digital-holographic interferometry with an image-intensifier system.

A method for recording digital holograms on an image intensifier coupled with a CCD sensor is presented. The advantage of the image intensifier is that it can be gated (electronic shutter action produced by controlling of the image intensifier's photocathode voltage). This allows us to record holograms with a short exposure time. Two holograms of an object submitted to dynamical displacements (e.g., vibrations) are recorded by two short exposures. The phase of the wave front recorded at different times is calculated from the recorded intensity by use of a digital Fourier-transform method. By comparison of the phases recorded it is possible to get the displacement of the object during a short interval. Experimental results are presented, and the problems related to the noise and to the spatial resolution are discussed.

Journal Article↗

Intrinsic fiber-optic ultrasonic sensor array using multiplexed two-wave mixing interferometry.

An intrinsic multiplexed laser interferometer is presented that allows for the simultaneous detection of acoustic waves by an array of fiber-optic sensors. The phase-modulated signals from each sensor are demodulated by use of an adaptive two-wave mixing setup. The light from each sensing fiber in the array is mixed with a reference beam in a single photorefractive crystal (PRC), and the output beams from the PRC are imaged onto separate photodetectors to create a multiplexed two-wave mixing (MTWM) system. The sensing fibers are embedded in graphite-epoxy composite panels, and detection of both acoustic emission and ultrasonic signals in these materials is demonstrated. The intrinsic MTWM system is an effective tool for the simultaneous demodulation of signals from a large fiber sensor array. Also, the adaptive nature of the MTWM setup obviates the need for active stabilization against ambient noise.

Journal Article↗

Optical interferometry for measurement of the geometric dimensions of industrial parts.

We describe an instrument for the measurement of surface flatness, parallelism, and size (thickness) of plane-parallel parts in a single measurement to 1sigma gauge capability of 0.02, 0.03, and 0.06 microm, respectively. A low-coherence IR profiler viewing both sides of the part simultaneously, believed to be novel, accommodates a wide variety of industrial surface finishes, including machined, ground, or lapped parts, with a 75-mm field of view and 15,000 pixels per side. A heterodyne laser displacement gauge together with an integrated zeroing system allows for a range of part sizes from 0 to 100 mm.

Journal Article↗

Effects of random vibration in high-speed phase-shifting speckle pattern interferometry.

The influence of random vibrations on the performance of a dynamic phase-shifting speckle pattern interferometer is investigated by means of experiments and numerical simulations. Two aspects are evaluated: first, temporal unwrapping reliability, second, vibration-induced phase noise. The former is found to be a significant constraint, even for peak velocities well below the Nyquist velocity limit of the interferometer. Shorter sampling windows and higher framing rates are shown to increase the unwrapping success rate, but longer windows reduce the phase error. Three analytical criteria for determining the expected unwrapping success rate are proposed and compared.

Journal Article↗

Surface displacement imaging by interferometry with a light emitting diode.

We present an imaging technique to measure static surface displacements of electronic components. A device is supplied by a transient current that creates a variation of temperature, thus a surface displacement. To measure the latter, a setup that is based on a Michelson interferometer is used. To avoid the phenomenon of speckle and the drawbacks inherent to it, we use a light emitting diode as the light source for the interferometer. The detector is a visible CCD camera that analyzes the optical signal containing the information of surface displacement of the device. Combining images, we extract the amplitude of the surface displacement. Out-of-plane surface-displacement images of a thermoelectric device are presented.

Journal Article↗

Absolute distance measurement by two-point-diffraction interferometry.

We present a point-diffraction interferometer that has been specially devised to perform absolute distance measurements in three dimensions. It is composed of two main parts: One is a target that moves in three dimensions, and the other is a stationary two-dimensional array of photodetectors. The target is made of point-diffraction sources that emit two spherical wave fronts, whose interference is monitored by the photodetectors. Application of a phase-shifting technique allows the phase values of the photodetectors to be precisely measured, which are then fitted to a geometric model of multilateration so as to determine the xyz location of the target by minimization of least-squares errors. Experimental results show that the proposed diffraction interferometer is capable of measuring the xyz coordinates of the target with a volumetric uncertainty of less than 1.0 microm over a working volume of a 100-mm side.

Journal Article↗

High-precision shape measurement by white-light interferometry with real-time scanner error correction.

White-light interferometric techniques allow high-precision shape measurement of objects with discontinuous structures by detecting the peak of the coherence envelope. These techniques assume a specific change in the optical path difference (OPD) between the interfering beams; however, the scanning device effecting that change often introduces OPD errors that are carried over to the measurements. We present a technique for measuring OPD changes from the collected interference fringes during each measurement. Information about the scan is directly fed into the algorithm, which compensates for the errors, resulting in improved measurement accuracy. The method corrects not only the scanner errors but also slowly varying vibrations. In addition, this technique can be easily adapted to any existing low-coherence interferometer because no large data storage or postprocessing is required.

Journal Article↗

Diversity detection of speckles for double-wavelength interferometry on rough surfaces.

When the topography of a rough surface is measured with a double-wavelength interferometer, the phase error of the signal corresponding to the synthetic wavelength increases in the vicinity of dark speckles. To overcome this problem we perform an amplitude-dependent averaging of the synthetic phase over independent speckles (diversity detection). We either use spatially neighboring speckles or in the case of depolarizing surfaces, we use speckles of the same spatial mode, but with orthogonal polarizations. For the latter case the lateral resolution stays unaffected. The reduction of the speckle noise is demonstrated experimentally for a laterally scanning double-wavelength interferometer with superheterodyne detection of the synthetic phase.

Journal Article↗