Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “DUST”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37Linked to original sources

Analysis of regional and temporal characteristics of PM10 during an Asian dust episode in Korea.

This study analyzes the regional and temporal distributions of PM10 concentrations observed in major metropolitan cities in Korea before, during and after a recent Asian dust episode in 2002. There were spatial and temporal variations in PM10 concentrations among the mid-western, the southwestern, the southeastern, and the southern parts of Korea during this Asian dust period due to the different air mass movement time and the different wind directions and speeds of prevailing winds in each city or region. The origins of the three-day Asian dust episode were identified by an analysis of two-day backward isentropic air trajectories. The different origins for each day also significantly contributed to the spatial and temporal variations in PM10 concentrations. A significant relationship was found between PM10 concentrations on the day preceding the first peak day and the first peak day of the Asian dust period but only in the mid-western areas. The concentrations of PM10 just after the Asian dust episode were much higher than those just before. There was a significant increase in a coarse fraction, having soil origins, of particles during the Asian dust episode. Concentrations of Mn, Fe, Ni and Cr extracted from the total suspended particulate (TSP) samples collected in 7 cities during the Asian dust episode were much higher when compared with other days in 2001. However, the Asian dust did not consistently increase the concentrations of lead, cadmium and copper as they are influenced by local sources such as local traffic or industrial emissions.

Air↗

Effects of Asian dust storm events on daily mortality in Taipei, Taiwan.

In spring, windblown dust storms originating in the deserts of Mongolia and China make their way to Taipei City. These occurrences are known as Asian dust storm events. The objective of this study was to assess the possible effects of Asian dust storms on the mortality of residents in Taipei, Taiwan, during the period from 1995 to 2000. We identified 39 dust storm episodes, which were classified as index days. Daily deaths on the index days were compared with deaths on the comparison days. We selected two comparison days for each index day, 7 days before the index day and 7 days after the index day. The strongest estimated effects of dust storms were increases of 7.66% in risk for respiratory disease 1 day after the event, 4.92% for total deaths 2 days following the dust storms and 2.59% for circulatory diseases 2 days following the dust storms. However, none of these effects were statistically significant. This study found greater specificity for associations with respiratory deaths, and this increases the likelihood that the association between dust events and daily mortality represents a causal relationship.

Air Pollution↗

Wind-induced dust generation and transport mechanics on a bare agricultural field.

Strong atmospheric winds may cause wind erosion and dust emissions on bare, dry, erodible fields. Since these dust emissions may exceed particulate matter limits established by the United States Environmental Protection Agency, information on dust generation and transport mechanics is needed to determine the particulate hazard of dust sources. Measurements of climatic variables and airborne sediment mass and concentration were made during three strong wind events on a bare, fine sandy loam field in west Texas. This study clearly shows that dust flux estimates were very sensitive to dust concentration measurement height. PM10 flux values estimated between heights of 2 and 5m were 2-5 times those estimated between heights of 5 and 10 m. Tower placement in relation to the upwind unerodible boundary produced significant differences in dust flux that varied with storm intensity. During the most intense storm event, the PM10 flux between heights of 2 and 5m measured at the tower 200 m from the unerodible boundary was almost 2.5 times as that measured at the tower 100 m from the unerodible boundary. Vertical PM10 dust flux was closely related with horizontal sediment flux only when the winds came from the same direction during the entire duration of horizontal sediment flux measurements.

Agriculture↗

Measurement of minimum ignition energies of dust clouds in the <1mJ region.

The lower energy limit of current standard test apparatus for determining the minimum ignition energy (MIE) of dust clouds is in the range of 1-3mJ. This is a quite severe limitation because many dusts ignite readily at this energy level. A new spark generator, capable of producing synchronised sparks of very low energies and with an integrated system for measurement of spark energy, has therefore been developed and employed to a number of easily ignitable dusts. Before testing the MIE of dust clouds, it was considered essential to calibrate the new spark generator against a gas of known MIE. For this purpose, a mixture of propane and air was selected. However, a comprehensive literature review revealed that the reported MIEs of this gas mixture vary significantly, depending on the spark discharge characteristics, including discharge duration. When taking these factors into account, it was concluded that the new spark generator yielded reasonable results for propane/air. Applying the new spark generator to explosive dust clouds showed that a number of dusts do in fact have MIEs that are one to two orders of magnitude lower than 1mJ. The new spark generator may therefore offer a basis for developing a standard test apparatus in the low-energy region. When using a method of triggering the spark by the explosive dust cloud itself, which probably is a more industrially relevant process than synchronisation between the dust dispersion and sparkover, somewhat higher MIEs were found compared to those determined when using synchronised sparks. However, even with this method of spark triggering, MIEs below 1mJ were found.

Dust↗

Filtration of dust in a circulating granular bed filter with conical louver plates (CGBF-CLPs).

A novel circulating granular bed filter with conical louver plates (CGBF-CLPs) was designed to remove dust particulates from the flue gas stream of a coal power plant. The purpose of this investigation was to evaluate the performance of the CGBF-CLPs. Dust collection efficiency and pressure drop data were analyzed to determine better operating conditions. The effect of solid mass flow rate, collector particle size and dust/collector particles separator types on the dust collection efficiency and pressure drop in the CGBF-CLPs were investigated in this study. The solid mass flow rate (B) varied from 15.59+/-0.44 to 20.36+/-0.68 g s(-1) and the initial average collector particle sizes were 1500 and 795 microm, respectively. Two types of separators, a cyclone and an inertial one, for separating the dust and collector particles were used in the CGBF-CLPs system. An Air Personal Sampler (SKC PCXR8) was used to determine the inlet and outlet dust concentrations. A differential pressure transmitter and data acquisition system were used to measure the pressure drop. Experimental results showed that the highest dust collection efficiency was 99.59% when the solid mass flow rate was 17.08+/-0.48 g s(-1) and the initial average collector particle size was 795 microm with the cyclone type separator. The results showed that the attrition fines of the original collector particles returning to the granular bed filter (GBF) reduced bed voidage. This phenomenon significantly increased the dust collection efficiency in the CGBF-CLPs. As a consequence, a bigger bed voidage creates a lower dust collection efficiency in the GBF.

Dust↗

Induction of chromosome aberrations in cultured human lymphocytes treated with sand dust storm fine particles (PM2.5).

The clastogenic activity of airborne air fine particulate matter (PM2.5, particulates with an aerodynamic diameter < or =2.5 microm) has already been demonstrated. However little is known about the health risks associated with sand dust storm PM2.5 and its extract. In order to investigate the clastogenic activity of sand dust storm PM2.5 (include its organic and inorganic extract) on human lymphocytes, the normal PM2.5 and sand dust storm PM2.5 samples were collected in Wuwei city (Gansu Province) and Baotou city (Inner Mongolia), China. The chromosomal aberration (CA) test was employed and the cells were treated with 0, 33, 100, 300 microg ml(-1) sand dust storm or normal ambient air PM2.5 suspension (physiological saline as solvent control), or inorganic extract (0, 75, 150, 300 microg ml(-1), physiological saline as solvent control) or organic extract (0, 20, 40, 80 microg ml(-1), DMSO as solvent control) at the beginning of the cell culture. The results indicated that sand dust storm PM2.5 and its extract as well as normal samples can induce increase in CA frequency. With the increase of treatment concentrations the CA frequency increased and the mitotic index (MI) values declined in a dose-response manner. In the same concentrates, the CA frequency of normal ambient air PM2.5 and its extract were significant higher than those of sand dust storm PM2.5 (P<0.05 or 0.01) except the treatment of Wuwei sample at higher doses (100, 300 microg ml(-1)), the treatment of inorganic extract of PM2.5 at the highest dose (300 microg ml(-1)) and the treatment of organic extract of PM2.5 at the higher dose (40 and 80 microg ml(-1)) either in Baotou or in Wuwei (P>0.05). The toxicity of sand dust storm PM2.5 and its extract at high dose is very potent. CA frequency of normal PM2.5 (include its organic extract) from Baotou were higher than those of Wuwei especially in low and middle dose (P<0.05), but the treatment results of sand dust storm PM2.5 (include its all extract) was not significant different between the cities (P>0.05).

Air Pollutants↗

Contrasting bronchoalveolar leukocyte responses in rats inhaling coal mine dust, quartz, or titanium dioxide: effects of coal rank, airborne mass concentration, and cessation of exposure.

The aim of this study was to determine the bronchoalveolar leukocyte response to airborne coal mine dust; quartz and titanium dioxide were used as positive and negative controls, respectively. Groups of rats were exposed to airborne mass concentrations of 10 and 50 mg/m3 of the dusts for 7 hr/day, 5 days/week and their bronchoalveolar space was lavaged at time points between 2 and 75 days of exposure, to assess the leukocyte response. This study revealed time-dependent and airborne mass concentration-dependent recruitment of neutrophils and macrophages into the bronchoalveolar region with coal mine dust inhalation but no real difference in the magnitude of the response between coal mine dusts from collieries mining coal of different rank and quartz content although the maximum quartz content in the dusts used was 6%. The inflammatory response was much less than that produced by quartz, at similar airborne mass concentrations, and more than that produced by titanium dioxide which was, in general, a poor inflammogen in the rat lung. Groups of rats were exposed to the airborne dusts for 32 or 75 days, then removed from the exposure chambers, and allowed to recover by breathing room air for a further 64 days. During this recovery period there was marked progression of the leukocyte response with quartz and persistence of the response with coal mine dust. Chronic recruitment of leukocytes to the lungs of individuals inhaling coal mine dust is likely to be an important factor in the development of coal workers' pneumoconiosis.

Administration, Inhalation↗

In vivo induction of sister chromatid exchanges in mice by nitrosated coal dust extract.

The genotoxicity of coal dust extract nitrosated with sodium nitrite (NaNO2) was investigated in mice with the in vivo sister chromatid exchange (SCE) assay system. The SCEs in bone marrow cells of mice were examined following single and double oral dosings of coal dust extract, NaNO2, and nitrosated coal dust extract. Coal dust extract and NaNO2 separately did not cause significant increases of SCEs either in single or in double dosings. Nitrosated coal dust extract in single doses did not increase SCEs but in two doses significant increases in SCEs were observed (P less than 0.02). The mutagenicity of the same extracts was tested in Salmonella typhimurium with the Ames tester strain TA98. Coal dust extract was either non- or weakly mutagenic and NaNO2 was nonmutagenic. The nitrosated coal dust extract caused pronouced increases in his+ revertants both with and without rat liver S9 activation. These findings provide additional evidence that nitrosation of ingested coal dust which may occur in the stomach environment could be one of the factors leading to the higher incidence of gastric cancer in coal miners.

Animals↗

Stimulation of alveolar macrophages by mineral dusts in vitro: luminol-dependent chemiluminescence study.

Luminol-dependent chemiluminescence (CL) of normal (nonactivated) rabbit alveolar macrophages (AMs) was measured in suspension upon stimulation by various size fractions of one quartz dust sample or by various mineral dusts (quartz, corundum, anatas, and chrysotile asbestos as an example of fibrous dust). The CL-triggering capacity of the tested dusts was inhibited by their preincubation with autologous serum. The intensity of luminol-dependent CL induced by particulate dusts upon their action on AMs depended on the kind of dust, on the dust particle sizes, and on the ratio of the number of particles to the number of cells in a given suspension. The cytotoxicity and/or fibrogenicity of the dust and its capacity to trigger the luminol-dependent CL of nonadherent AMs were not directly correlated.

Animals↗

Pentachlorophenol in indoor environments. Correlation of PCP concentrations in air and settled dust from floors.

The investigation of settled dust is a proven and simple screening-method for considering indoor contamination for semivolatile compounds. Here we investigate the correlation of PCP concentrations in air and freshly settled dust from floors. Air and dust samples were taken from 75 rooms in 30 buildings with suspicion of an application of PCP-containing wood preservatives. Sampling was repeated four times within 18 months. PCP air concentrations were found in the range of <0.3-576 ng m-3 (mean value 25.3 ng m-3, median 2.5 ng m-3). PCP dust concentrations were found in the range of 0.083-79 microg g-1 (mean value 3.5 microg g-1, median 1.1 microg g-1. A weak highly significant correlation (P < 0.0001) with a correlation coefficient of R2 = 0.433, of the PCP concentration in dust with the PCP concentration in air, was observed. Measurement of PCP concentrations in dust, therefore, is a suitable screening method for the evaluation of indoor contamination with PCP. Due to the high dispersion of the data it is not possible to calculate PCP concentrations in air from concentrations in dust although a highly significant correlation of the PCP concentrations in air and dust was found.

Air Movements↗

Quantitative bronchial challenge tests with wheat flour dust administered by spinhaler: comparison with aqueous wheat flour extract inhalation.

BACKGROUND: Quantitative bronchial challenge tests with flour dust for the diagnosis of bakers' asthma may be performed by inhalation of flour delivered to the patient's respiratory tract by sophisticated equipment. OBJECTIVE: This study was carried out to assess the diagnostic value of bronchial challenge tests with flour dust inhalation from capsules administered by a Spinhaler (Fisons Inc., Loughborough, U.K.) and to compare this method quantitatively with bronchial challenge tests with a commercially available wheat flour extract. METHODS: A highly selected group of 36 bakers with work-related symptoms of rhinitis or asthma were referred to our department, a tertiary referral center, from 1992 to 1995. Thirty-four of the subjects and 10 atopic control subjects were included in this study. After the assessment of bronchial hyperresponsiveness on day 1, subjects were randomized to inhale an aqueous wheat flour extract at concentrations of 0.01, 0.1, 1, 10, and 100 mg/ml by tidal volume breathing for 10 minutes or to inhale wheat flour dust filled in capsules on days 2 and 3. One, two, and four capsules (maximum of 7 cumulative capsules) of flour dust were administered by a Spinhaler. In addition, skin prick tests were performed with a battery of environmental and occupational allergens. Total serum IgE and specific IgE to wheat flour were measured by standard procedures. RESULTS: Seventeen bakers and two control subjects demonstrated a positive skin test response to wheat flour (wheal > or = 3 mm). Fifteen bakers demonstrated a fall of 50% or more in specific airway conductance after inhalation of the commercial wheat flour extract, and 11 demonstrated such a fall in specific airway conductance after inhalation of wheat dust. Three control subjects had a positive bronchial challenge response to the extract, but dust inhalation from the capsule did not cause positive bronchial reactions in control subjects. When a 50% fall of specific airway conductance was used as criterion for a positive bronchial provocation test result, sensitivity for the extract or dust inhalation was 0.44 and 0.32, respectively, and specificity was 0.7 and 1.0, respectively. If only subjects with a positive skin test response to wheat flour were considered, sensitivity of both tests was 0.65. With more stringent criteria for the gold standard, there was a trend for a higher sensitivity but a lower specificity of the extract inhalation. Both methods were safe. CONCLUSION: The validity of bronchial challenge tests with wheat flour dust inhaled from Spinhaler capsules was superior to that of tests done with a commercially available aqueous wheat flour extract. The higher specificity of the Spinhaler method might be an advantage if bronchial challenge tests are used as confirmation tests.

Administration, Inhalation↗

Occupational exposure to metal or wood dust and aetiology of cryptogenic fibrosing alveolitis.

BACKGROUND: We have previously suggested that cryptogenic fibrosing alveolitis (CFA) may be caused by occupational exposures, particularly to metal or wood dust. We have specifically investigated this hypothesis in a case-control study of patients with CFA. METHODS: We obtained lifetime occupational histories by postal questionnaire from 218 patients with CFA and 569 controls matched for age, sex, and community, living in the Trent region of the UK. Information was subsequently verified by telephone interview in 165 cases and 408 controls. Serum IgE, rheumatoid factor, and antinuclear antibodies and skin sensitivity to common allergens were measured in cases and in one matched control for each. FINDINGS: The relative risk of CFA, after adjustment for smoking, was significantly increased in relation to questionnaire-reported exposure to metal dust (odds ratio 1.68 [95% CI 1.07-2.65], p = 0.024) or to wood dust (1.71 [1.01-2.92], p = 0.048). Similar results were obtained with the telephone interview data. Significant exposure-response effects were found for both metal-dust and wood-dust exposure. CFA was also associated with the presence of rheumatoid factor or antinuclear antibodies, but not with positive allergen skin tests or raised IgE concentrations. There was no evidence of interaction between the effects of rheumatoid factor, antinuclear antibodies, positive skin allergen tests, or IgE concentrations and exposure to metal or wood dust. The combined aetiological fraction attributable to exposure to metal or wood dust was of the order of 20%. INTERPRETATION: Occupational exposures to metal or wood dust are independent risk factors for CFA. Avoidance or limitation of these exposures may provide an opportunity to prevent the disease.

Autoantibodies↗

Determination of heavy metal concentrations in street dusts in Istanbul E-5 highway.

Components and quantity of street dust are environmental pollution indicators especially in big cities. Street dust is generally composed of car exhaust gas originated particles and wind-transported particles. Heavy metals, which are found in street dust, such as Pb, Cu, Mn, Zn, Cd and Ni are significant for environmental pollution. According to the kind of vehicle in traffic, quantity and type of heavy metals vary in street dust. The use of leaded gasoline gives a boost to the importance of lead level especially in street dust even at the start of 21st century. These metals possess bioaccumulation property, and the possibility of the amount of these metals reaching a critical value and threatening human health increases the importance of this issue. In this study, street dusts have been collected from E-5 Highway from Topkapi to Avcilar regions that spans about 18 km in Istanbul, Turkey, and Pb, Cu, Mn, Zn, Cd and Ni concentrations have been detected in street dust. Twenty-two street dust samples were taken from a total of 22 different points at previously decided 14 main areas. Analyses were conducted using Leeds Public Analyst method. According to the results of this study, Pb, Cu and Zn concentrations in E-5 Highway between Topkapi and Avcilar region in Istanbul were higher than maximum concentration levels of these heavy metals in normal soil. This situation indicates that there is heavy metal pollution in the inspected area in E-5 Highway in Istanbul.

Biological Availability↗

Mite fauna in the home and sensitivity to house-dust and storage mites.

In search of potential new indoor allergen sources, all mites in dust from homes of 55 asthmatic children living in three climatic regions in Sweden were counted and identified by light microscope. Antibodies of the IgE class against three house-dust mites and three storage mites were measured in corresponding serum samples. Mites were found in all but two homes from the northernmost area, where levels also were lower than in the other regions. The highest mite densities were most often found in bedrooms (50%) and living rooms (40%). Mite density was increased in homes with high humidity and was higher in bungalows than in flats. House-dust mites predominated in the south and storage mites in the east central area, particularly in kitchens and bathrooms. Mite-density and IgE-antibody levels against house-dust mites were significantly associated. The same association applied to storage mites. Other species numbered around 100 mites/g dust in some homes. Microscopy helps to identify potentially important mites. Analysing home dust only for house-dust mites will underestimate mite exposure. Storage mites may be as relevant to sensitivity as house-dust mites. As other species occasionally were found in high numbers, their relevance should also be assessed.

Allergens↗

Persistent organic pollutants in dusts that settled indoors in lower Manhattan after September 11, 2001.

The explosion and collapse of the World Trade Center (WTC) was a catastrophic event that produced an aerosol impacting many residents, workers, and commuters after September 11, 2001. In all, 12 bulk samples of the settled dust were collected at indoor locations surrounding the epicenter of the disaster, including one sample from a residence that had been cleansed and was once again occupied. Additionally, one sample was collected from just outside a fifth story window on the sill. These samples were analyzed for many components, including inorganic and organic constituents as well as morphology of the various particles. The results of the analyses for persistent organic pollutants on dusts that settled at indoor locations are described herein, including polycyclic aromatic hydrocarbons, polychlorinated biphenyls, and select organo-chlorine pesticides. The Sigma(86)-PCB concentrations, comprising less than one part per million by mass of the bulk in the two samples analyzed, indicated that PCBs were of limited significance in the dust that settled at indoor locations across lower Manhattan. Likewise, organo-chlorine pesticides, Hexachlorobenzene, Heptachlor, 4,4'-DDE, 2,4'-DDT, 4,4'-DDT and Mirex were found at even lower concentrations in the bulk samples. Conversely, Sigma(37)-PAHs comprised up to 0.04% (<0.005-0.036%) by mass of the bulk indoor dust in the 11 WTC impacted bulk indoor samples. Analysis of one sample of indoor dusts collected from a vacuum cleaner of a rehabilitated home shows markedly lower PAH concentrations (<0.0005 mass%), as well as differing relative contributions for individual compounds. In addition to similar concentrations, comparison of PAH concentration patterns (i.e. chemical fingerprints) shows that dusts that settled indoors are chemically similar to previously measured WTC dusts found at outdoor locations and that these PAH analyses may be used in identifying dusts of WTC origin at indoor locations, along with ascertaining further needs for cleaning.

Air Pollution, Indoor↗

Exposure to wood dust and endotoxin in small-scale wood industries in Tanzania.

Workers in small-scale wood industries (SSWI) have increased risks of developing asthma and other respiratory diseases. Wood dust and microbial agents have both been suggested to play a role, but few studies have measured endotoxin exposure in SSWI in Africa. We assessed inhalable dust levels in 281 samples from 115 workers and bacterial endotoxins levels in 157 samples from 136 workers from SSWI in Dar es Salaam, Tanzania. The overall geometric mean of personal exposure was 3.3 mg/m(3); geometric standard deviation (GSD) 2.5; range 0.45-67.0 mg/m(3)) and 91 EU/m(3) (GSD 3.7; range 9-4914.8 EU/m(3)) for wood dust and endotoxins, respectively. Dust and endotoxin levels were weakly correlated (r = 0.44, n = 157, P < 0.0001). Between- and within-worker variances and percentages explained by the differences among job titles and seasons were 0.31 (9%) and 0.35 (30%), respectively, for wood dust exposure, and 0.35 (0%) and 0.35 (38%) for endotoxin exposure. Higher dust and endotoxin exposure levels were observed in the dry compared to the wet season, after correcting for differences in exposure between jobs. Carving and manual cleaning were associated with the highest dust exposures. Sewing seat covers and manual cleaning were associated with the highest endotoxin exposures. Dust and endotoxin exposure levels in SSWI are high and appropriate control measures are necessary.

Air Pollution↗

Evaluation of interference to conventional and real-time PCR for detection and quantification of fungi in dust.

Advances in polymerase chain reaction (PCR) have permitted accurate, rapid and quantitative identification of microorganisms in pure cultures regardless of viability or culturability. In this study, a simple sample processing method was investigated for rapid identification and quantification of fungal spores from dust samples using both conventional and real-time PCR. The proposed method was evaluated for susceptibility to interference from environmental dust samples. Stachybotrys chartarum and Aspergillus fumigatus were used as test organisms. The sensitivity of detection in pure culture was 0.1 spore DNA equivalents per PCR reaction corresponding to 20 spores ml(-1) in the sample. However, 1 spore DNA equivalent per PCR reaction corresponding to 200 spores ml(-1) in the sample was the lowest amount of spores tested without interference in dust samples spiked with spores of either fungal species. The extent of inhibition was calculated using conventional and real-time PCR reactions containing fungal spores, specific primers, specific probes (for real-time PCR) and various amounts of dust. The results indicate that the extent of inhibition by dust on PCR varies with the type and amount of dust, and number of spores. No interference in the analysis of spiked samples was detected from 0.2 mg ml(-1) of four real-life dust samples at p-value >0.05 using 2 x 10(4) spores for conventional PCR and 2 x 10(5) spores for real-time PCR. However, samples containing >0.2 mg ml(-1) real-life dust compromised the PCR assay. These results suggest the potential usefulness of a simple sample processing method in conjunction with PCR for monitoring the fungal content of aerosols collected from indoor environments.

Air Pollution, Indoor↗

Influence of fluticasone and salmeterol on airway effects of inhaled organic dust;an in vivo and ex vivo study.

Inhalation of dust from swine confinement buildings induces airway inflammation with an increase in both inflammatory cell numbers and secretion of proinflammatory cytokines in the lungs. It is not known whether anti-asthma drugs, which influence airway inflammation in asthma, also influence the airway reaction to inhaled organic dust. In the present study we examined the effects of a ss2-agonist (salmeterol) and an inhaled steroid (fluticasone) on the swine dust-induced cell and cytokine content of the lower airways, and cytokine release in cultured alveolar macrophages. Healthy volunteers were pretreated with inhaled salmeterol (n = 8), fluticasone propionate (n = 8) or placebo (n = 8) for about 2 weeks and exposed to dust in a pig house. Bronchoalveolar lavage was performed both before medication and after dust exposure. Cell differential counts and cytokine analyses in bronchoalveolar lavage fluid (BALF) were examined. Alveolar macrophages were cultured and cytokine release was studied, both in unstimulated cells and after lipopolysaccharide (LPS) stimulation. Unstimulated alveolar macrophages from swine dust-exposed individuals released less IL-6, IL-8 and tumour necrosis factor-alpha (TNF-alpha) after, than before, exposure (P < 0.01). Medication did not influence basal cytokine production. Fluticasone inhibited LPS-induced IL-6 and IL-8 release (P < 0.05). There was no significant difference between the groups. There was a large and significant increase (P < 0.05) in alveolar macrophage, granulocyte, lymphocyte numbers, and IL-6 and TNF-alpha content in BALF in all three groups following dust exposure, with no significant difference between the groups. These findings suggest that drugs which are known to influence and control airway inflammation in asthma do not have major effects on airway inflammation induced by the inhalation of organic dust.

Adrenergic beta-Agonists↗