Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CHROMATOGRAPHY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37Linked to original sources

Coupling of nanoflow liquid chromatography to matrix-assisted laser desorption/ionization mass spectrometry: real-time liquid chromatography run mapping on a MALDI plate.

The major obstacle in the use of matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) instruments in the analysis of complex proteome samples is the lack of a direct coupling of a highly resolving separation technique with the mass spectrometer itself. To overcome this drawback, a spotting device for capillary and nanoflow liquid chromatography (LC) with a special liquid deposition principle for lowest volumes was developed. The instrument is able to perform MALDI spotting in real time in order to deposit the LC run on the MALDI plate, and therefore couples the high resolution power of nano-RP-HPLC separation directly with MALDI-MS. This work describes the development and optimization of a method for spotting with online matrix addition, and illustrates its use in the analysis of a complex proteome sample.

Chromatography, High Pressure Liquid↗

Separation and quantitation of cytochrome c oxidase subunits by Mono-Q fast protein liquid chromatography and C18 reverse-phase high-performance liquid chromatography.

Mono-Q fast protein liquid chromatography (FPLC) combined with C18 reverse-phase HPLC was used for quantitative subunit analysis of bovine heart cytochrome c oxidase, a multisubunit membrane complex. By this approach normal cytochrome c oxidase preparations were shown to be a mixture of enzyme that has all 13 subunits and complexes that are missing 1-3 subunits. A distinct advantage of this procedure is that homogeneous 13- or 11-subunit enzyme can be easily isolated from heterogeneous cytochrome c oxidase mixtures. The method involves: (1) separation of complexes that are depleted of subunits using Mono-Q FPLC and (2) quantitative subunit analysis of the purified complexes by C18 reverse-phase HPLC with a water/acetonitrile gradient in 0.1% trifluoroacetic acid. The approach has four distinct advantages over other methods of analysis, e.g., sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) or C4 reverse-phase HPLC. (1) The reproducible yield and the baseline resolution between each eluting subunit permits quantitative determination of the subunit content with an accuracy of +/- 5%. (2) Subunits that are very difficult to separate by SDS-PAGE, e.g., subunits VIa, VIb, and VIc, are completely resolved by this system. (3) The combination of Mono-Q purification and C18 reverse-phase HPLC analysis permits an accurate assessment of both homogeneity and subunit content. (4) The quantitative nature of the reverse-phase HPLC system also makes it a powerful method for analyzing the specificity and extent of chemical modification of specific subunits as is shown by the difference in reactivity of subunit VIa toward N-iodoacetylamidoethyl-1-aminonaphthalene-5-sulfonate and 4,4'-dipyridyl disulfide.

Animals↗

Artifact-free quantification of free 3-chlorotyrosine, 3-bromotyrosine, and 3-nitrotyrosine in human plasma by electron capture-negative chemical ionization gas chromatography mass spectrometry and liquid chromatography-electrospray ionization tandem mass spectrometry.

Halogenation and nitration of biomolecules have been proposed as key mechanisms of host defense against bacteria, fungi, and viruses. Reactive oxidants also have the potential to damage host tissue, and they have been implicated in disease. In the current studies, we describe specific, sensitive, and quantitative methods for detecting three stable markers of oxidative damage: 3-chlorotyrosine, 3-bromotyrosine, and 3-nitrotyrosine. Our results indicate that electron capture-negative chemical ionization-gas chromatography/mass spectrometry (EC-NCI GC/MS) is 100-fold more sensitive than liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-MS/MS) for analyzing authentic 3-chlorotyrosine, 3-bromotyrosine, and 3-nitrotyrosine. Using an isotopomer of tyrosine to evaluate artifactual production of the analytes during sample preparation and analysis, we found that artifact generation was negligible with either technique. However, LC-MS/MS proved cumbersome for analyzing multiple samples because it required 1.5 h of run and equilibration time per analysis. In contrast, EC-NCI GC/MS required only 5 min of run time per analysis. Using EC-NCI GC/MS, we were able to detect and quantify attomole levels of free 3-chlorotyrosine, 3-bromotyrosine, and 3-nitrotyrosine in human plasma. Our results indicate that EC-NCI GC/MS is a sensitive and specific method for quantifying free 3-chlorotyrosine, 3-bromotyrosine, and 3-nitrotyrosine in biological fluids in a single, rapid analysis and that it avoids generating any of the analytes ex vivo.

Artifacts↗

High-performance liquid chromatography of amino acids, peptides and proteins. CXXXIX. Impact of operating parameters in large-scale chromatography of proteins.

Large-scale chromatography has been playing an important role in downstream treatment processing in biotechnology. In order to improve the productivity, the throughput of the chromatographic equipment was often increased by increasing the flow-rate and/or by increasing the column sample loading. This paper reports the results of a study on the impact of these and other operating parameters in affinity and ion-exchange chromatographic columns when used for protein purification. A sectional model was developed to predict protein adsorption processes in a packed column. The formulations of this mathematical model are presented in the Appendix. The present study was carried out with computer simulation based on this model and using data obtained from laboratory-scale columns. This model can simulate both the adsorption and washing stages of the protein purification process for both porous and non-porous particles. The effects of changing operating parameters were simulated and contour plots were generated for the easy identification of these effects. It was shown that both flow-rate and column loading can have a considerable impact on the processing rate and the yield of the column. As for the column capacity utilization, the impact of changing flow-rate is not significant at column loading of less than 80% in the test case. It was suggest that the present investigation provides a systematic predictive strategy which will greatly reduce the need for expensive, labour-intensive and time-consuming experimental work during process scale-up.

Adsorption↗

Determination of polycyclic aromatic hydrocarbons in edible oils and fats by on-line donor-acceptor complex chromatography and high-performance liquid chromatography with fluorescence detection.

Various off-line methods for clean-up and sample enrichment are available for the analysis of polycyclic aromatic hydrocarbons (PAHs) in edible oils and fats. These methods consist of laborious and time consuming procedures. This study reports an on-line method using LC-LC coupling. After clean-up of the sample on a donor-acceptor complex chromatography (DACC) column the PAHs are transferred to and separated on an analytical HPLC column. Quantification is carried out with fluorescence detection. The DACC column clean-up is fast and is carried out during the HPLC run of the previous sample. Compared to the traditional methods this automated on-line method saves considerable time and significantly reduces the amount of solvent waste. The method uses common HPLC equipment and its performance has been evaluated.

Carcinogens↗

Application of multidimensional affinity high-performance liquid chromatography and electrospray ionization liquid chromatography-mass spectrometry to the characterization of glycosylation in single-chain plasminogen activator. Initial results.

Preliminary results are presented using a combination of affinity chromatography, reversed-phase HPLC and electrospray ionization mass spectrometry to produced peptide maps for N-linked, O-linked and non-glycosylated peptides from an endoproteinase LysC digest of DSPA alpha 1, a recombinant DNA derived glycoprotein. Although the system was used to identify a number of major N-linked structures, notably complex biantennary structures attached to asparagine 362, no O-linked glycopeptides from the possible 4 attachment sites were identified. The system did, however, demonstrate the feasibility of the approach and the applicability of the instrumental system.

Carbohydrate Sequence↗

Gas chromatography-mass spectrometry and gas chromatography-tandem mass spectrometry of cyclic fatty acid monomers isolated from heated fats.

The analysis of hydrogenated cyclic fatty acid monomers isolated from heated linseed and sunflower oils is achieved by gas chromatography-tandem mass spectrometry of their pentafluorobenzyl esters. Collisionally activated dissociation of the carboxylate anions produced by electron-capture ionization shows remote charge-site fragmentation that allows location of cyclopentane and cyclohexane rings by examining the resulting mass-analysed ion kinetic energy spectra. Oxidative ozonolysis of the methyl esters of the unsaturated cyclic fatty acid monomers allows location of some double bonds. However, preliminary results obtained with remote charge fragmentation of synthetic unsaturated models make this approach an alternative for double bond location in the cyclic fatty acid monomers isolated from heated fats.

Cyclopentanes↗

Chemical synthesis of dioxygen-18 labelled omega-/beta-oxidized cysteinyl leukotrienes: analysis by gas chromatography-mass spectrometry and gas chromatography-tandem mass spectrometry.

Cysteinyl leukotrienes (LT) C4, LTD4 and LTE4 are potent mediators of anaphylaxis and inflammation. LTE4 is extensively metabolized in man mainly by omega-oxidation followed by subsequent beta-oxidation to more polar and biologically inactive metabolites. This paper describes a method for the synthesis of [1,20-18O2]-carboxy-LTE4, [1,18-18O2]-carboxy-dinor-LTE4, and [1,16-18O2]-carboxy-14,15-dihydro-tetranor-LTE4 starting from the unlabelled dimethyl esters of 20-carboxy-LTA4, 18-carboxy-dinor-LTA4 and 16-carboxy-14,15-dihydro-tetranor-LTA4, respectively, by separate chemical conjugation with cysteine hydrochloride in H2-18O-methanol followed by alkaline hydrolysis with Li18OH. The isotopic purity of the isolated reaction products was 94% at 18O for all three preparations while only 0.3% remained unlabelled as confirmed by negative-ion chemical-ionization gas chromatography-mass spectrometry (GC-NICI-MS) after their catalytical reduction/desulphurization and derivatization. The 18O2-labelled compounds are demonstrated to be suitable internal standards for quantification by GC-NICI-MS and GC-NICI-tandem MS. We found by GC-NICI-tandem MS that the excretion rate of 20-carboxy-LTE4 is comparable to that of LTE4 (both in nmol/mol creatinine, mean +/- S.E.) in healthy children (26.7 +/- 4.7 vs. 32.0 +/- 6.0, n = 9) and adults (13.9 +/- 1.1 vs. 27.2 +/- 5.4, n = 3).

Adult↗

Determination of benzylpenicillin in milk at the pg ml-1 level by reversed-phase liquid chromatography in combination with digital subtraction chromatography technique.

A method for the determination of benzylpenicillin in milk at very low levels by a pre-column derivatisation LC-method is described. Nine millilitres of milk were precipitated and extracted. The sample was concentrated 40 times and the recovery of benzylpenicillin was about 90%. The derivatisation of benzylpenicillin was made by the beta-lactam ring specific formation of the mercuric mercaptide of the penicillenic acid in the presence of imidazole. A technique called digital subtraction chromatography (DSCh), which uses the built-in background compensation programme of the chromatographic data processor, was applied to the chromatographic step of the analysis. The blank sample required for this technique was obtained by the beta-lactam ring specific hydrolysis of benzylpenicillin by penicillinase. By this technique it was possible to reduce interfering background peaks on the chromatograms and to increase the specificity of the method. Standard curves were made in the range 0.2-1000 ng benzylpenicillin ml-1 milk. The relative standard deviation (RSD) at 1 ng ml-1 milk, corresponding to an injection of 3.9 ng benzylpenicillin-sodium converted to the mercuric mercaptide of the penicillenic acid, was +/- 7.8% and RSD at 10 ng ml-1 milk was +/- 1.6%.

Animals↗

Determination of a process intermediate of celiprolol and its potential impurities by gradient high-performance liquid chromatography--application of high-low chromatography.

3-(3-acetyl-4-hydroxyphenyl)-1,1-diethylurea (A-1354), is a synthetic intermediate of the beta-adrenergic blocker, celiprolol hydrochloride. A liquid chromatographic method has been developed and validated for the determination of bulk A-1354 and its potential impurities. High-low chromatography was used to improve the detectability of trace impurities. Enhanced chemical detectability was achieved by comparing the detector response of trace-impurity peaks from a stock sample solution (high-concentration) with the detector response for the A-1354 peak in a quantitatively diluted working sample solution (low-concentration). Chromatographic separation was achieved by gradient elution of A-1354 and its known impurities using an Ultrasphere C18 analytical column (5 microns, 250 x 4.6 mm i.d.). The gradient mobile phase components were methanol and 0.1% triethylammonium phosphate, pH = 4.0. The flow rate was 0.9 ml min-1 with UV absorbance detection at 236 nm. The method was determined to be specific, linear, precise and accurate for A-1354 and its known impurities. Known impurities of A-1354 are quantitated to 0.05% (w/w).

Chromatography, High Pressure Liquid↗

On-line identification of tropane alkaloids from Erythroxylum vacciniifolium by liquid chromatography-UV detection-multiple mass spectrometry and liquid chromatography-nuclear magnetic resonance spectrometry.

The bark of catuaba (Erythroxylum vacciniifolium Martius, Erythroxylaceae), a tree native to the northern part of Brazil, was investigated for its alkaloid content. With the aim of obtaining preliminary structure information on-line, the alkaloid extract was analysed by high-performance liquid chromatography coupled to diode array UV detection, to mass spectrometry and to nuclear magnetic resonance. Interpretation of on-line spectroscopic data obtained from this extract led to structural elucidation of six new alkaloids and partial identification of 18 potentially original alkaloids bearing the same tropane skeleton esterified in positions 3 and 6 by 1-methyl-1H-pyrrol-2-carboxylic acid and/or 4-hydroxy-3,5-dimethoxybenzoic acid.

Alkaloids↗

Comparison of high-speed counter-current chromatography and high-performance liquid chromatography on fingerprinting of Chinese traditional medicine.

Active constituents of Chinese traditional medicine (CTM) are influenced by soils, climates, and growth stages. Therefore, fingerprint is important in quality control of CTM. Our studies showed for the first time that high-speed counter-current chromatography (HSCCC) could be applied in the development of fingerprint of CTM. Twelve components were separated from extracts of three crude samples of Salvia miltiorrhiza Bunge, which were collected from different growth locations. All 12 components of each sample were isolated within 13 h coming with good correspondence by using HSCCC. Relative standard deviation (R.S.D.) values of the retention time in HSCCC separation was less than 3% satisfied the precision requirements of national standards in the fingerprint development. As a new approach, HSCCC was compared to the conventional approach-HPLC in our experiments. The fingerprint developed by HPLC comprised 11 peaks that collected within 45 min. R.S.D. values of retention times of the corresponding peaks in HPLC analysis were very small (maximum 0.66% and average 0.10%). In conclusion, HSCCC was a feasible method to be used in the development of fingerprint of CTM.

Chromatography, High Pressure Liquid↗

Characterisation of beeswax in works of art by gas chromatography-mass spectrometry and pyrolysis-gas chromatography-mass spectrometry procedures.

Pyrolysis (Py) with in situ derivatisation with hexamethyldisilazane-gas chroma-break tography-mass spectrometry (GC-MS) and a gas chromatography-mass spectrometry procedure based on microwave-assisted saponification were used to identify the organic components in small sized beeswax samples. With the latter procedure quantitative recoveries can be made and hydrocarbons, alcohols and omega-1-diols in the neutral fraction, and fatty acids and omega-1-hydroxy acids in the acidic fraction can be efficiently separated and detected. Both procedures were used to characterise a wax anatomic sculpture "The Plague" (1691-1694) by Gaetano Zumbo, resulting in the identification of beeswax and a Pinaceae resin. The GC-MS analysis brought to light some essential differences in beeswax composition between the raw material and the old modelled wax thus giving some clear indications about the recipe used by the sculptor.

Alcohols↗

Affinity chromatography with monolithic capillary columns I. Polymethacrylate monoliths with immobilized mannan for the separation of mannose-binding proteins by capillary electrochromatography and nano-scale liquid chromatography.

Monolithic capillary columns with surface-immobilized mannan have been introduced for affinity-based micro-column separations by nano-liquid chromatography (nano-LC) and capillary electrochromatography (CEC). Two kinds of polymethacrylate monoliths were prepared, namely poly(glycidyl methacrylate-co-ethylene dimethacrylate) and poly(glycidyl methacrylate-co-ethylene dimethacrylate-co-[2-(methacryloyloxy)ethyl]trimethyl ammonium chloride) to yield neutral and cationic macroporous polymer, respectively. While neutral monoliths with immobilized mannan were only useful for affinity nano-LC, the cationic monoliths with surface-bound mannan were useful in both affinity nano-LC and affinity CEC. The cationic monoliths allowed a relatively high electro-osmotic flow (EOF) when mannan was immobilized to the epoxy monolith via a positively charged spacer arm, triethylenetetramine. The neutral monoliths exhibited lower permeability under pressure-driven flow (PDF) than the cationic monoliths indicating that the latter had wider flow-through pores than the former. Both types of monoliths with immobilized mannan exhibited strong affinity toward mannose-binding proteins (MBP) such as the plant lectins concanavalin A and Lens culinaris agglutinin and a mammalian lectin (e.g. rabbit serum mannose-binding protein). Due to the strong binding affinity, the monoliths with surface bound mannan allowed the injection of large volume of rabbit serum and to isolate in a single run the mannose-binding protein in an amount sufficient to run with it sodium dodecylsulfate-polyacrylamide gel electrophoresis (SDS-PAGE) and matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS), thus demonstrating their capability in "nano-proteomics".

Animals↗

Capillary liquid chromatography-microcoil 1H nuclear magnetic resonance spectroscopy and liquid chromatography-ion trap mass spectrometry for on-line structure elucidation of isoflavones in Radix astragali.

Miniaturization and hyphenation of chromatographic separation techniques to nuclear magnetic resonance spectroscopy is being increasingly demanded in the field of biomedical, drug metabolite and natural product analysis. Herein, capillary liquid chromatography was coupled on-line to microcoil 1H nuclear magnetic resonance spectroscopy (capLC-NMR) equipped with a 1.5 microL solenoidal probe for structure elucidation of isoflavones in Radix astragali. The extract was screened by HPLC-UV-MS as the preliminary step and four major peaks were identified tentatively by ion trap mass spectrometry molecular weights and characteristic fragments. Then, stopped-flow capLC-UV-NMR was performed using 33 microg extract injected on-column. The four peaks were parked manually in the micro probe one by one and corresponding 1H NMR spectra were recorded with good resolutions under the applied capLC-NMR conditions (120 and 220 ng injected on-column for peaks 2 and 4, respectively). All aromatic regions of 1H NMR spectra correlated well to the characteristic signals of isoflavone aglycone protons. And the signal corresponding to the anomeric proton of the glucopyranoside of isoflavone glycoside was also obtained for peak 1. Therefore, these four peaks are determined as calycosin-7-O-beta-D-glucopyranoside (1), ononin (2), calycosin (3) and formononetin (4) unambiguously. The capLC-NMR results indicate that this hyphenated technique could be used for the determination of a great variety of natural products from small sample amounts, e.g., only 5 g R. astragali in this study.

Aconitum↗

Separation and characterization of underivatized oligosaccharides using liquid chromatography and liquid chromatography-electrospray ionization mass spectrometry.

Native cyclodextrin-based columns are particularly useful for the analysis of oligosaccharides because the retention of these carbohydrates is based mainly on the hydrogen bonding interactions of oligosaccharide hydroxyl groups with the stationary phase. Thus, the retention time predictably increases with the number of analyte hydroxyl groups, which corresponds to the elongation of the oligosaccharide chain. High-performance liquid chromatography (HPLC) coupled to electrospray ionization (ESI) mass spectrometry (MS) was used for the separation and characterization of underivatized oligosaccharide mixtures. With the limits of detection as low as 50 pg, all individual components of oligosaccharide mixtures (up to 11 glucose units long) were baseline resolved on a Cyclobond I 2000 column and detected using ESI-MS. Low flow rates and narrow I.D. columns increase the ESI-MS sensitivity significantly. The method showed potential usefulness for the sensitive and quick analysis of hydrolysis products of polysaccharides, and for trace levels of individual oligosaccharide or oligosaccharide isomers from biological systems.

Acetonitriles↗

High temperature liquid chromatography and liquid chromatography-mass spectroscopy analysis of octylphenol ethoxylates on different stationary phases.

Temperature was investigated as active parameter in the liquid chromatography (LC) analysis of octylphenol ethoxylates. Significant differences in selectivity were observed when the oligomers were analyzed by reversed phase LC (RPLC) on silica-, zirconia- and polystyrene/divinylbenzene based stationary phases at low (ambient), medium and elevated temperature with acetonitrile/water as mobile phase. As ascertained by LC-mass spectroscopy (MS), in most cases the elution order of the oligomers was completely reversed comparing ambient and high temperature separations. On a graphitized carbon type column, the selectivity remained unchanged, regardless the analysis temperature. Also in normal phase LC, the elution order remained unaffected by temperature variations both for acetonitrile/water and methanol/water mixtures as mobile phase. Surprisingly, when reversed phase LC on a octadecylsilicagel column at different temperatures was repeated with methanol instead of acetonitrile as mobile phase ingredient, the reversal of elution order did not take place. Results are evaluated in terms of thermodynamic parameters.

Chromatography, Liquid↗

Epoxidized soy bean oil migrating from the gaskets of lids into food packed in glass jars. Analysis by on-line liquid chromatography-gas chromatography.

The migration of epoxidized soy bean oil (ESBO) from the gasket in the lids of glass jars into foods, particularly those rich in edible oil, often far exceeds the legal limit (60 mg/kg). ESBO was determined through a methyl ester isomer of diepoxy linoleic acid. Transesterification occurred directly in the homogenized food. From the extracted methyl esters, the diepoxy components were isolated by normal-phase LC and transferred on-line to gas chromatography with flame ionization detection using the on-column interface in the concurrent solvent evaporation mode. The method involves verification elements to ensure the reliability of the results for every sample analyzed. The detection limit is 2-5 mg/kg, depending on the food. Uncertainty of the procedure is below 10%.

Chromatography, Liquid↗