Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Bone Substitutes”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37Linked to original sources

Influence of pore dimensions on bone ingrowth into porous hydroxylapatite blocks used as bone graft substitutes. A histometric study.

The aim of the present study was to determine the influence of pore dimensions of porous hydroxylapatite (HA) blocks on bone ingrowth when used as interposed grafts in alveolar ridge bone defects. HA blocks with pore diameters of 150 microns and 260 microns were used. Ten animals received one implant each with small pore sizes, whilst in 10 other animals blocks with larger pore sizes were used. The blocks were examined histometrically and spatially reconstructed for determination of 3-dimensional distribution of bone ingrowth. In the group of implants with 150 microns pore diameter a high rate of implant loss occurred. The blocks with 260 microns pore diameter had 3 times more bone ingrowth compared with the 150 microns group with uniform distribution.

Animals↗

Novel hydroxyapatite ceramics with an interconnective porous structure exhibit superior osteoconduction in vivo.

Calcium hydroxyapatite ceramics (CHA) are nontoxic materials, provoke little reaction from tissues, and by virtue of these properties represent a good starting point for creating bone substitutes. Although several porous CHAs have been used clinically, there have been few reports that CHA is fully replaced by newly formed bone, which may be due to its structure and the limited connectivity between pores. We recently developed a fully interconnected porous CHA (IP-CHA) by adopting a "foam-gel" technique. Structural analysis by scanning electron microscopy revealed that IP-CHA had spherical pores of uniform size that were interconnected by window-like holes. The surface of the wall structure was smooth, and hydroxyapatite particles were bound tightly to one another. Most of the interpore connections of IP-CHA ranged from 10 to 80 microm in diameter (average, 40 microm). When the cylindrical IP-CHA (diameter, 6 mm; height, 15 mm) was implanted into a rabbit femoral condyle, bone, and bone marrow with abundant vessels formed deep in the pores through the interpore connections. Within a period of 6 weeks, new bone had formed and penetrated to a distance of 3 mm from the surface of the IP-CHA implant. Furthermore, a compression test at 9 weeks revealed that the implanted IP-CHA steadily increased in strength to more than double the value of the initial test. These results indicate that the IP-CHA may have clinical utility as a superior bone substitute.

Animals↗

Biomechanical comparison of inside-outside screws, cables, and regular screws, using a sawbone model.

Our aim was to conduct a biomechanical comparison of the pull-out strengths of inside-outside (I/O) screws, cables, and bone screws to determine whether I/O screws provide greater pull-out resistance than cables or bone screws, and their effectiveness with the screw diameter. There is no remarkable biomechanical experimental study comparing the I/O technique with conventional spinal techniques. The diameter of the screw heads were also biomechanically tested to determine the optimal size that can be used. In this study, 45 blocks of 50x50x5 mm of "sawbone" (synthetic bone, model 1137, Pacific Research Laboratories, Vashon, WA, USA) were used as bone substitutes. Fifteen sets of 14-mm inside-outside Dynalok screws and nuts, 15 wire cables, and 15 bone screws were inserted into a separate sawbone block. An MTS Bionx materials testing machine was used to measure the load to failure of each implant. The mean values and standard deviations of each group were calculated and Student's t-test was used for comparison. The load to failure of the inside-outside screws was significantly greater than that of the cables (p<0.0000004) and the regular bone screws (p<0.000002). The results also revealed that increasing the diameter of the head of the screw also increases the resistance against the pull-out strengths. Thus, using a larger screw in occipitocervical stabilization provides safe and stable fixation of the occipital bone to the cervical spine. This study also proved that sawbone is a useful and reliable alternative to allogenic fresh cadaveric bone grafts or animal bones for certain biomechanical testing.

Atlanto-Occipital Joint↗

Synchrotron radiation microtomography of bone engineered from bone marrow stromal cells.

Osteoprogenitor cells expanded in vitro and associated with porous ceramic scaffolds have been proposed as bone substitutes. Animal models have been developed to test the efficacy of various cell populations and scaffolds in promoting bone repair. Qualitative analysis of the new bone formed within the ceramic scaffold is relatively easy by conventional histology. On the other hand, quantitative data are difficult to obtain. X-ray computed microtomography was used as a possible experimental technique to obtain quantitative data on the three-dimensional structure of newly formed bone and of remaining scaffold in implants after 8 weeks in vivo. Measurements were performed at the European Synchrotron Radiation Facility on beamline ID19 with a spatial resolution of about 5 microm. This study clearly indicates the possibility of nondestructive quantitative analysis of bone-engineered constructs. The technique appears suitable to compare different scaffolds (and possibly different cell populations) with regard to bone formation efficiency and reabsorbability of biomaterials in the immunodeficient mouse model.

Absorptiometry, Photon↗

[Regeneration instead of reparation: a critical review of the autogenous bone transplant as "golden standard" of reconstructive oral surgery].

Autogenous bone transfer is still regarded as the "golden standard" for many indications in oral and cranio-maxillofacial surgery. In this overview, the status of the autogenous bone is re-evaluated under consideration of current research results, clinical long-term studies, risks and safety of the patient as well as the costs. Due to the further development of modern bone substitute materials, which reveal in parts superior long-term results for special indications, the routine use of autogenous bone has to be critically reviewed.

Bone Regeneration↗

Fixation principles in metaphyseal bone--a patent based review.

Osteoporotic changes start in cancellous bone due to the underlying pathophysiology. Consequently, the metaphyses are at a higher risk of "osteoporotic" fracture than the diaphysis. Furthermore, implant purchase to fix these fractures is also affected by the poor bone quality. In general, researchers and developers have worked on three different approaches to address the problem of fractures to osteoporotic bone: adapted anchoring techniques, improved load distribution as well as transfer with angular stable screws, and augmentation techniques using bone substitutes. A patent-based review was performed to evaluate which ideas were utilized to improve fixation in osteoporotic, metaphyseal bone, especially in the proximal femur, and to analyze whether the concept had entered clinical use. Anchoring devices that are either extramedullary or intramedullary have a long clinical history. However, demanding surgical techniques and complications, especially in poor quality bone, are justification that such implants and their corresponding surgical techniques need to be improved upon. Expanding elements have been evaluated in the laboratory. The results are promising and the potential of this approach has yet to be fully exploited in the clinics. Internal fixators with angular stable screws open the door for many new anchorage ideas and have great potential for further optimization of load distribution and transfer. Augmentation techniques may improve anchorage in osteoporotic bone. However, the properties of bone substitute materials will need to be modified and improved upon in order to meet the demanding requirements. If we summarise the development process and the clinical use of implants to date, we have to clearly state that more factors than simply biomechanical advantage will determine the clinical success of a new fixation principle or a new implant. Instead, fracture treatment of patients with osteoporosis really needs an interdisciplinary approach!

Bone Nails↗

Calcium hydroxyapatite ceramic implants in bone tumour surgery. A long-term follow-up study.

We reviewed the results of 51 patients with benign bone tumours treated by curettage and implantation of calcium hydroxyapatite ceramic (CHA). The mean follow-up was 11.4 years (10 to 15.5). Post-operative fractures occurred in two patients and three had local recurrences; three had slightly limited movement of the adjacent joint and one had mild osteoarthritis. There were no allergic or neoplastic complications. In all cases, radiographs showed that the CHA was well incorporated into the host bone. Statistical analysis showed that absorption of the implanted CHA was greater in males (odds ratio, 6.2; 95% CI, 1.6 to 23.7) and younger patients (odds ratio, 0.6 for increase in age of 10 years; 95% CI, 0.91 to 0.99). However, the implanted CHA was not completely absorbed in any patient. We conclude that CHA is a useful and safe bone substitute for the treatment of benign bone tumours.

Adolescent↗

New regenerative technologies: rationale and potential for periodontal regeneration: 1. New advances in established regenerative strategies.

Regenerative techniques have been clinically available for over a decade, but with limited success in promoting new bone, cementum and connective tissue attachment. New understanding of the tissues involved in regeneration and of the materials used to promote regeneration have led to new advances. This is the first of two articles that discusses new regenerative technologies with respect to their rationale and potential for periodontal regeneration and focuses on root conditioning, bone grafts and bone substitutes, and guided tissue regeneration.

Acid Etching, Dental↗

Characterization and osteoblast-like cell compatibility of porous scaffolds: bovine hydroxyapatite and novel hydroxyapatite artificial bone.

Three different porous scaffolds were tested. The first two were prepared by sintering bovine bone. The third scaffold was prepared using three-dimensional gel-lamination, a new rapid prototyping method, and was named as hydroxyapatite artificial bone. X-ray diffraction and Fourier transform infrared spectroscopy analysis confirmed that the samples were mainly highly crystalline hydroxyapatite ceramics. Scanning electron microscopy and mercury intrusion porosimetry measurement showed that the pores were interconnected and pore sizes ranged from several microns to hundreds of microns. Mouse osteoblast-like cells grown on the three scaffolds retained their characteristic morphology. Cell proliferation and differentiation, analyzed by methylthiazol tetrazolium (MTT) and alkaline phosphatase activity assays, were significantly higher on the hydroxyapatite artificial bone than on the other two scaffolds tested. All the scaffolds provided good attachment, proliferation and differentiation of bone cells. These results indicate that the scaffolds have a favorable interaction with cells, they support cell growth and functions, and therefore these scaffolds may have great potential as bone substitutes. The three-dimensional gel-lamination method is proven to be an attractive process to design and fabricate bone scaffolds with favorable properties, and therefore, has promising potential for bone repair applications.

Alkaline Phosphatase↗

Effect of various properties of hydroxyapatite ceramics on osteoconduction and stability.

Hydroxyapatite ceramics (HA) are widely used for clinical applications as a bone substitute or dental implant because they have been shown to be biocompatible and exhibit excellent osteoconductivity when grafted into the bone tissue. However, the influence of the physical properties of HA on the osteoconduction and stability remains unclear. We examined here the effect of various properties of HA granules on osteoconduction and stability using 6 types of HA granules. The HA granules were grafted into the rabbit tibia and the initial bone formation and long-term stability of the new bone were studied histologically. The following results were obtained; 1. Osteoconduction of the HA granule was influenced by the shape. Multi-nuclear granules with continuous pores ranging from 30 to 200 microns in diameter showed both excellent osteoconduction and stability. 2. Solubility behavior of HA granules, which was effected by the relative surface area sizes, also seemed to be an important factor for osteoconduction and stability. 3. Stable bi-phase ceramics with HA and beta TCP were produced at the sintering temperature of 1200 degrees C when Mg was added. The beta TCP and Mg content did not negatively influence the initial osteoconduction or long-term stability.

Animals↗

Calcium phosphate cement in musculoskeletal tumor surgery.

BACKGROUND AND OBJECTIVES: Calcium phosphate cement (CPC) is an injectable biocompatible bone substitute that has been used for various applications in orthopedic surgery. However, no extensive clinical studies of the use of CPC to fill bone cavities after curettage of musculoskeletal tumors have been reported. The present study reviewed the results for 56 musculoskeletal tumors treated by curettage and CPC implantation. METHODS: Assessment was based on clinical examination and radiographic findings. Variables for clinical assessment included pain, limb function, and complications. Median follow-up was 18.5 months (range 6-47 months). RESULTS: One patient experienced post-operative fractures. Three patients displayed local recurrence. One patient developed post-operative superficial wound infection, and two patients with large bony defect exhibited non-infectious serous discharge. No serious adverse effects such as deep venous thrombosis, pulmonary embolism were encountered. In all cases, CPC was radiographically well adapted to the surrounding host bone as of final follow-up. CONCLUSIONS: CPC appears to offer a useful bone substitute for the treatment of musculoskeletal tumors. As the follow-up period for this study was short, further long-term follow-up studies are needed.

Adolescent↗

[Bone resection-reconstruction of the diaphyseal zone in animals. Development of an experimental model, application to the study of biomaterials compared with allografts].

The aim of this work was to develop an animal model of bony resection-reconstruction of the diaphyseal zone and to test the different bone substitutes in comparison with allografts. Eighteen 2-cm diaphyseal resections of the femur were performed in Beagle dogs. Reconstruction was performed using a bone substitute (5 cryopreserved allografts, 5 blocks of polymethylmetracylate with PMH hydroxyapatite, 8 blocks of phosphocalcium ceramic materials with biphased macropores) associated with centromedullar lockek nail. The PMH blocks gave radiographically and histologically unsatisfactory results. Allografts consolidated in two-thirds of the junctions, consolidating with an exuberant periosteal callus contrasting with minimal intracortical repair. No stress fractures were observed despite normal activity. BCP blocks consolidated in three-fourths of the junctions but pseudoarthrosis at the centre of the block was observed in cases in which the fixation was not perfectly stable. Bone occupied 20 and 24% of the surface of the ceramic block in the central and junctional zones respectively. These findings demonstrated the reliability of internal fixation material in the animal model and allowed us to evaluate the different methods for analysing bone repair on histographic and microradiographic images. In addition, the potential of synthetic material such as MBC might be useful in large resections in mechanically stressed zones.

Animals↗

Bioactivation of an anorganic bone matrix by P-15 peptide for the promotion of early bone formation.

This animal experiment compared the regenerative processes within defined bony defects of the porcine skull after delivery of routinely utilized bone graft materials: anorganic bone matrix (ABM) and an identical ABM carrying the cell binding peptide P-15. Particulated autogenous bone was used as a control group. The chosen porcine model guaranteed the transferability of the obtained results to clinical practice. A total observation period of 6 months was defined. The bone samples were examined microradiographically and histologically at 8 specific times. Sufficient osseointegration and osseoconduction could be demonstrated for both anorganic bone minerals. However, in the selected model significantly higher mineralization rates (p = 0.0286) were found in the microradiographic image at 12 weeks after application of the bioactive form. The histological examination confirmed this accelerating effect on bone formation starting at day 3. At the end of the study after 6 months, the mineralization values had equalized in both study groups. For the first time, the material was demonstrated to be suitable as a bone substitute material for the treatment of larger bony defects in a large animal model. The P-15 sequence accelerated the process of bone formation on the surface of the anorganic bone matrix as early as 3 days but was not traced over the whole term of the study.

Animals↗

Hydroxyapatite cement, a smart biomaterial for craniofacial skeletal tissue engineering.

Craniofacial skeletal surgery continues to command special interest from patients and clinicians dealing with skeletal defects. Autologous bone grafts remain the standard treatment by which bone substitutes are compared. A continued interest in avoiding donor sites and realizing "off the shelf convenience" has fostered the use of biomaterial bone substitutes. The first generation of implant materials used for cranial reconstruction were not specifically designed for biomedical applications. Methylmethacrylate was adopted for cranial applications after use in implant fixation for hip arthroplasty by Charnley, The development of this material did not employ sophisticated implant evaluation and mainly focused on standard mechanical properties demonstrated on the benchtop.

Journal Article↗

[Ceramic-like xenogeneic bone combining with bone marrow].

OBJECTIVE: This experimental study was aim to investigate the osteogenesis of ceramic-like xenogeneic bone (CXB) combining with bone marrow (BM). METHODS: The CXB combining BM was implanted into the sacrospinalis muscle of rabbits, and CXB implanted alone was used as control. Eighteen Japanese rabbits with long ear were used. The size of CXB was 5 mm x 5 mm x 5 mm, and the implanted materials were taken out at 2, 4, 8, 12, 16 and 24 weeks after implantation. The histological and histochemical characteristics were investigated. RESULTS: There existed cartilage and new bone in the groups of CXB combining BM in 2 weeks. Later, be cartilage turned out to the bone and in eight weeks the medullary cavity appeared. However, as the time went on, new bone formation increased and typical osteogenesis could be found. While in the groups of CXB alone, no formation of new bone or cartilage was found. CONCLUSION: The implantation of CXB combined with BM could result in new bone formation in the way of osteoconduation, osteoinduction, and providing, osteoblasts or chondroblasts. It could be an ideal bone substitute, and its clinical use in future seemed very hopeful.

Animals↗

[Bone transplantation methods].

Author sums on the basis of the literature of this country and of the international literature the more frequently used methods of bone substitution, their mechanical and biological characteristics. On the basis of the practice of their institute and of the international publications it can be stated that beside the usual transplantation of preserved bone the always increasing clinical claim makes the introduction and the knowledge of other methods also necessary. The advantages and disadvantages of the bone grafts of different types are detailed. It is stated that none of the implantates of different characteristics fulfils perfectly the ideal mechanical and biological requirements. To obtain the possibly best result it is recommended to choose, and on individual indication, the bone substitution method that will fulfil in the given case the requirements desired.

Bone Transplantation↗

Missing osteoconductive effect of a resorbable PEO/PBT copolymer in human bone defects: a clinically relevant pilot study with contrary results to previous animal studies.

PEO/PBT 70/30 (POLYACTIVE(R) 70/30), a degradable porous copolymer with elastic properties, was found to be osteoconductive in many animal studies. The aim of this study was to determine the osteoconductive effect in a human paired control iliac defect model. In seven patients undergoing anterior spinal interbody fusion surgery, two bicortical iliac defects for autograft harvesting were created. The defect size was identical for both defects measuring about 40 x 15 mm (group I). One defect was filled with the degradable implants, whereas the remaining one was left untreated as a control. The defect site for treatment was chosen randomly. In three further patients, only one defect measuring about 40 x 35 mm was created (group II). All patients were examined clinically and radiologically by spiral-CT after 1, 6, 12, 24, and 52 weeks. Three-dimensional reconstructions as well as CT-volumetric measurements using 1 mm sections were used as evaluation methods. In group I, a two-tailed paired t-test showed that the treated defects had significantly less formation of new bone than the untreated ones (p < 0.05 after 12 weeks, p < 0.01 after 52 weeks). Also, in group II, not much bone ingrowth could be observed. The histological evaluation of one patient in group I revealed no bone within the pores, and a fibrous layer between bone and implant was always present. Therefore, PEO/PBT 70/30 cannot be recommended as a bone substitute for clinical use. Differences in bone regeneration between humans and certain animal species as well as inapplicable defect models in previous animal studies are discussed as possible reasons for the failure.

Animals↗