Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “AUTOMATION”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37Linked to original sources

Automation of specific human gene detection.

An instrument/chemistry system is described that automates a new chemical procedure functionally equivalent to Southern blotting. A fluorescence gel scanner that detects migrating DNA fragments in real-time analyzes the samples produced by a prototype liquid-handling instrument that automates a solution-phase hybridization/solid-phase capture chemistry for DNA analysis. The combination of this chemistry, the gel scanner, and robotic automation eliminates the tedium encountered in traditional manual methods for specific gene detection and reduces analysis time from days to hours. Restriction fragment lengths are measured with high precision by comparison with in-lane standards to minimize effects attributable to migration anomalies. The utility of this automated system is demonstrated by executing a clinical research application involving hybridization to a multi-copy repeat sequence on the Y chromosome and its detection.

Automation↗

Cognitive demands in automation.

As the nature of a task changes with increasing automation, so do the cognitive demands on the human operator. The present study examines the implications of such changes on subjective workload and automation design issues. A variety of tasks (continuous flight control, discrete target acquisition, and decision making) was used to tax the different cognitive systems. Each task could be performed alone or in combination with other tasks. Performance and subjective workload ratings, obtained by three workload scales, were examined as a function of the level of automation. Results demonstrated the usefulness of the multiple resource approach to task analysis. All three workload scales were found to be sensitive to the task demands. The Bedford scale was particularly impressive in distinguishing the different types of resources in demand. Both the multiple resource model's performance predictions and the subjective workload ratings were shown to be invaluable for decisions on how and what to automate.

Adolescent↗

[A computer-based microscope as the foundation for automated prescreening systems].

The prototype of an automated screening system for cytological preparations is under development. The conditions concerning the handling of such system require the development of a special microscope with certain adjustment functions to be automated. The main specifications of this microscope are: --1 Splitting the light path into two synchronously usable channels for low and high magnification; whereby both images are projected onto two tv-cameras --Additional light path for visual observation --Automated focusing via movement of the microscope objective --Automated supply of immersion oil --Positioning and loading unit for slides --Microprocessor control --Closed and dust-protected design. Besides the mentioned specifications different microscopical observation methods, i. e. transmitted light bright field, incident fluorescence, are possible. The system can be used for all samples which are prepared on standard slides.

Autoanalysis↗

Automated intelligent microscopy (AIM) and its potential application in the clinical laboratory.

The microscope is the most ubiquitous instrument in the clinical laboratory. We discuss improvements in its use, in terms of "front-end" automation of specimen handling and "back-end" automation of image analysis: automated intelligent microscopy. Examples of spatial and spectral differentiation illustrate the potential of this automated version of microscopy as a useful tool with very powerful analytical capabilities for the clinical laboratory.

Animals↗

Implementing hospital library automation: the GaIN project. Georgia Interactive Network for Medical Information.

The GaIN (Georgia Interactive Network for Medical Information) Hospital Libraries' Local Automation Project was a one-year, grant-funded initiative to implement an integrated library system in three Georgia hospitals. The purpose of the project was to install the library systems, describe the steps in hospital library automation, and identify issues and barriers related to automation in small libraries. The participating hospitals included a small, a medium, and a large institution. The steps and time required for project implementation were documented in order to develop a decision checklist. Although library automation proved a desirable approach for improving collection accessibility, simplifying daily routines, and improving the library's image in the hospital, planners must be sure to consider equipment as well as software support, staffing for the conversion, and training of the library staff and end users.

Catalogs, Library↗

MultiMap: an expert system for automated genetic linkage mapping.

With the advent of the Human Genome Project, the ability to rapidly construct comprehensive and accurate linkage maps based on genetic marker data from family studies is an absolute necessity. In addition to their usefulness in localizing genes for both simple and complex disorders, linkage maps are invaluable tools for genetic counseling using linked marker genes. Several computer program packages are publicly available which aid in the construction of linkage maps by computing multipoint likelihoods for specified locus orders. However, these programs work in a step-by-step fashion, requiring intensive user-intervention and analysis at each step. Such a repetitive process is amenable to computerized automation. We have developed and tested an expert system computer program, MultiMap, for automated genetic linkage mapping. This program greatly reduces the amount of user-computer interaction, increasing the accuracy and speed with which a map can be constructed. In addition, because the total mapping time is greatly reduced through automation, it is now feasible to explore and compare various mapping heuristics and mapping criteria in order to develop the most appropriate approach, or set of approaches, for genetic linkage mapping. MultiMap need not be restricted to the construction of genetic maps, but could be adapted to aid in the automated construction of physical maps as well.

Automation↗

Cervical smears prepared by an automated device versus the conventional method. A comparative analysis.

An automated, fluid-based method for the preparation of cervical Papanicolaou smears/slides was compared to the conventional Papanicolaou smear (CPS) method used for the screening of neoplasia. We determined diagnostic agreement and sources of error for diagnostic disagreement. For 665 patients, one cervical sample was collected to make one CPS. The collection devices, a wooden Ayre spatula and endocervical brush, were rinsed into a vial with fluid medium to be processed in the automated device. All slides were distributed among five cytotechnologists in a blind fashion. Exact diagnostic agreement was 94.6%. The results were not statistically significant (P > or = .70, McNemar's test) but were clinically important, as evidenced by the detection of low grade lesions (LGL), during initial screening, on three slides prepared by the automated device but not on their matched-pair CPSs (0.5% of all specimens). After reevaluation, the three matched CPSs demonstrated LGL. Sources of diagnostic error on the CPSs were: air-drying artifact, obscuring blood/inflammation, crowding/overlapping of cells and/or absence of diagnostic cells. The only source of error in the automated-method smears was absence of diagnostic cells.

Adolescent↗

A comparison of the effects of automated percutaneous diskectomy and conventional diskectomy on intradiscal pressure, disk geometry, and stiffness.

Diskectomy, chemonucleolysis, percutaneous diskectomy, and laser ablation are used to treat patients with sciatica. The effects of percutaneous diskectomy on the intradiscal pressure of the human disk are not known. Our aims were to determine (a) whether removal of nucleus through automated percutaneous diskectomy significantly reduces intradiscal pressure without altering the disk geometry and stiffness, and if so, how much nucleus removal is required to achieve these goals; and (b) whether the effects of conventional diskectomy on these same parameters are equivalent to removal of nucleus through automated percutaneous diskectomy. Cyclic compressive loads of 20-900 N were applied to lumbar disks. Conventional diskectomy or automated percutaneous diskectomy (performed for 40 min with biomechanical measurements made four times at 10-min intervals) was then performed under zero load and the specimens retested under the same cyclic compressive loading. There were significant (p < 0.01) decreases in intradiscal pressure (by 7% under 900 N) after 10 min of automated percutaneous lumbar diskectomy. There were no further significant decreases in pressure during the next 30 min of percutaneous diskectomy. There were also significant decreases in pressure due to a puncture hole made with the Nucleotome trephine alone, without removal of disk material, and there was no difference in pressure after trephining alone and after percutaneous diskectomy. Decreases in disk height were significant, ranging from 5% at 10 min to 7% at 40 min of treatment. There were equivalent decreases in intradiscal pressure and disk height due to removal of similar amounts of nucleus during conventional diskectomy and during 40 min of percutaneous diskectomy.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

[Discrepancy of platelet numbers between automated blood cell analysis and manual counting in the patients with thrombocytopenia].

Automated blood cell analyzer can measure the numbers of blood cell and a histogram patterns of WBC, RBC and Platelet (PLT), and calculate the blood cell indices (RDW, MPV, PDW, etc). It is important clinically in the patients with thrombocytopenia (below 10 x 10(4)/microliter) to measure correct platelet number. However platelet number with automated blood cell analyzer was influenced by the changes in erythrocyte morphology or various PLT conditions. We subclassified the patients with thrombocytopenia into 5 groups according to the histogram pattern of PLT, and compared platelet numbers among NE-8000 analysis (Sysmex), H*2 analysis (Bayer's) and manual method in each group. In the group of abnormal histogram pattern of PLT, platelet numbers obtained with NE-8000 or H*2 were significantly low comparing to manual numbers. About 70% of samples of which Platelet Distribution Width (PDW) was abnormal showed discrepant values between automated analysis and manual eye count. In conclusion, discrepant low platelet count would be obtained by automated analysis and therefore should be carefully interpreted in the patients with thrombocytopenia and abnormal platelet histogram pattern.

Automation↗

FISH and chips: automation of fluorescent dot counting in interphase cell nuclei.

Fluorescence in situ hybridization allows the enumeration of chromosomal abnormalities in interphase cell nuclei. This process is called dot counting. To estimate the distribution of chromosomes per cell, a large number of cells have to be analyzed, especially when the frequency of aberrant cells is low. Automation of dot counting is required because manual counting is tedious, fatiguing, and time-consuming. We developed a completely automated fluorescence microscope system that can examine 500 cells in approximately 15 min to determine the number of labeled chromosomes (seen as dots) in each cell nucleus. This system works with two fluorescent dyes, one for the DNA hybridization dots and one for the cell nucleus. After the stage has moved to a new field, the image is automatically focused, acquired by a Photometrics KAF 1400 camera (Photometrics Ltd., Tuscon, AZ, USA), and then analyzed on a Macintosh Quadra 840AV (Apple Computer, Inc., Cupertino, CA, USA) computer. After the required number of cells has been analyzed, the user may interact to correct the computer by working with a gallery of the cell images. The automated dot counter has been tested on a number of normal specimens where 4,'6-diamidino-2-phenylindole (DAPI) was used for the nucleus counterstain and a centromeric 8 probe was used to mark the desired chromosome. The slides contained lymphocytes from cultured blood. We compared the results of the dot counter with manual counting. Manually obtained results, published in the literature, were used as the "ground truth." For a normal specimen, 97.5% of cells will have two dots. Fully automated scanning of 13 slides showed that an average of 89% of all nuclei were counted correctly. In other words, an average of 11% has to be interactively corrected, using a monitor display. The machine accuracies, after interactive correction, are comparable to panels of human experts (manual). The fully automatically obtained results are biased with respect to manual counting. An error analysis is given, and different causes are discussed.

Algorithms↗

[Principles of creating software and equipment for automating the workplace of laboratory physician].

Automation of laboratory tests is a pressing problem of today, for examinations of the hemopoietic system is a priority in the diagnosis of the majority of diseases and in detecting the effects of unfavorable ecological factors on man; in addition, laboratory studies are time- and labor-consuming. A system "Automated Work Place of a Laboratory Physician" has been developed, which permits automated scanning of a routinely stained blood smear with automated focussing on the detected objects. A preset number of objects is filed in the archive for further identification by a morphologist. The results can be stored in the information database for each patient and be transferred through telecommunication network. The system includes a computer hypertext Blood Atlas.

Automation↗

Evaluation of automated methods of measuring hemoglobin and hematocrit in horses.

OBJECTIVE: To evaluate the accuracy of 3 automated methods of determining Hct and hemoglobin (Hb) concentration, compared with manual methods. Animals-22 clinically normal adult horses of various breeds. PROCEDURE: A blood sample was obtained from each horse. Six dilutions (representing Hct of 0, 10, 20, 40, 60, or 70%) were prepared from each sample and analyzed, using 1 of 2 blood gas analyzers or a hemoximeter (for automated determinations) or the Wintrobe macrohematocrit and cyanmethemoglobin methods (for manual determinations). Regression analysis was used to determine mean slope relationships between Hct and Hb measurements obtained by use of manual versus automated methods. Slopes were compared, using Student's t-test. RESULTS: Of the 3 automated methods examined, only 1 blood gas analyzer reported Hct and Hb values that were not significantly different from those determined by use of manual methods; however, this analyzer could not report Hb concentrations below 2.5 g/dl. The other blood gas analyzer reported values for Hct and Hb concentrations that were consistently higher than those obtained by use of manual methods at Hct < or = 20% and Hb < or = 6.6 g/dl. The hemoximeter yielded more accurate results if the Hb concentration was between 6.6 and 20 g/dl. CONCLUSION: Although there were some limitations in measuring at low Hb concentrations, the method of determining Hb concentration and Hct with blood gas analyzer 2 was more accurate than that with blood gas analyzer 1 (Hct and Hb concentration) or the hemoximeter (Hb only).

Animals↗

Short-wavelength automated perimetry and retinal nerve fiber layer evaluation in suspected cases of glaucoma.

OBJECTIVES: To determine if short-wavelength automated perimetry (SWAP) provides evidence that indicates early functional losses in ocular hypertensive subjects and to establish a direct comparison with early structural abnormalities in the retinal nerve fiber layer (RNFL). METHODS: A total of 160 eyes belonging to 83 patients with ocular hypertension (intraocular pressure >21 mm Hg and normal results on standard automated perimetry evaluation), on which a SWAP and RNFL study were performed, were examined. One hundred twenty-eight age-matched subjects without ocular hypertension were evaluated to establish the 95% and 99% confidence intervals at each of the 76 exploration points of the SWAP test. RESULTS: The RNFL study results were normal in 83 cases (51.8%) and pathologic in 77 cases (48.1%). The SWAP results were pathologic in 57 cases (35.6%). Significant differences (P<.001) were observed when comparing the distribution of normal and pathologic SWAP results among the types of defects in the RNFL (focal wedge, diffuse atrophy, and mixed atrophy). CONCLUSIONS: Short-wavelength automated perimetry is a useful test for the early detection of visual field losses. It is more sensitive than standard automated perimetry and provides a high association with RNFL assessment, which has proved capable of detecting signs of glaucomatous damage several years before the onset of the typical visual field defects.

Adult↗

Motion automated perimetry identifies early glaucomatous field defects.

OBJECTIVE: To determine if motion automated perimetry can identify early glaucomatous visual field defects in patients with suspected glaucoma (by disc), those with ocular hypertension, and those with primary open-angle glaucoma. METHODS: Motion automated perimetry, a foveally centered motion test, and standard visual field tests were conducted on one randomly selected eye of normal patients (n = 38), patients with suspected glaucoma (by disc) (n = 28), patients with ocular hypertension (n = 18), and patients with primary open-angle glaucoma (n = 21). Subjects' performance on both motion tests were compared with their performance on standard perimetry. RESULTS: Perimetric motion thresholds significantly distinguished the groups (P< or =.001), while the foveally centered motion test was unable to separate them (P< or =.32). Of the total patients, 90.5% of those with glaucoma, 39.3% of those with suspected glaucoma, 27.8% of those with ocular hypertension, and 5.3% of the normal subjects had abnormal results on motion automated perimetry testing. Perimetric motion thresholds were significantly correlated with standard visual field thresholds (P< or =.001). CONCLUSION: Motion automated perimetry identifies visual field defects in patients who already show standard visual field loss as well as in a moderate percentage of those with suspected glaucoma and ocular hypertension, indicating that the testing of discrete locations might be necessary for increased diagnostic utility.

Aged↗

Automated location of dysplastic fields in colorectal histology using image texture analysis.

Automation in histopathology is an attractive concept and recent advances in the application of computerized expert systems and machine vision have made automated image analysis of histological images possible. Systems capable of complete automation not only require the ability to segment tissue features and grade histological abnormalities, but, must also be capable of locating diagnostically useful areas from within complex histological scenes. This is the first stage of the diagnostic process. The object of this study was to develop criteria for the automatic identification of focal areas of colorectal dysplasia from a background of histologically normal tissue. Fields of view representing normal colorectal mucosa (n = 120) and dysplastic mucosa (n = 120) were digitally captured and subjected to image texture analysis. Two features were selected as being the most important in the discrimination of normal and adenomatous colorectal mucosa. The first was a feature of the co-occurrence matrix and the second was the number of low optical density pixels in the image. A linear classification rule defined using these two features was capable of correctly classifying 86 per cent of a series of training images into their correct groups. In addition, large histological scenes were digitally captured, split into their component images, analysed according to texture, and classified as normal or abnormal using the previously defined classification rule. Maps of the histological scenes were constructed and in most cases, dysplastic colorectal mucosa was correctly identified on the basis of image texture: 83 per cent of test images were correctly classified. This study demonstrates that abnormalities in low-power tissue morphology can be identified using quantitative image analysis. The identification of diagnostically useful fields advances the potential of automated systems in histopathology: these regions could than be scrutinized at high power using knowledge-guided image segmentation for disease grading. Systems of this kind have the potential to provide objectivity, unbiased sampling, and valuable diagnostic decision support.

Adenomatous Polyps↗

High-throughput single-strand conformation polymorphism analysis by automated capillary electrophoresis: robust multiplex analysis and pattern-based identification of allelic variants.

Genetic diagnosis of an inherited disease or cancer often involves analysis for unknown point mutations in several genes; therefore, rapid and automated techniques that can process a large number of samples are needed. We describe a method for high-throughput single-strand conformation polymorphism (SSCP) analysis using automated capillary electrophoresis. The operating temperature of a commercially available capillary electrophoresis instrument (ABI PRISM 310) was expanded by installation of a cheap in-house designed cooling system, thereby allowing us to perform automated SSCP analysis at 14-45 degrees C. We have used the method for detection of point mutations associated with the inherited cardiac disorders long QT syndrome (LQTS) and hypertrophic cardiomyopathy (HCM). The sensitivity of the method was 100% when 34 different point mutations were analyzed, including two previously unpublished LQTS-associated mutations (F157C in KVLQT1 and G572R in HERG), as well as eight novel normal variants in HERG and MYH7. The analyzed polymerase chain reaction (PCR) fragments ranged in size from 166 to 1,223 bp. Seventeen different sequence contexts were analyzed. Three different electrophoresis temperatures were used to obtain 100% sensitivity. Two mutants could not be detected at temperatures greater than 20 degrees C. The method has a high resolution and good reproducibility and is very robust, making multiplex SSCP analysis and pattern-based identification of known allelic variants as single nucleotide polymorphisms (SNPs) possible. These possibilities, combined with automation and short analysis time, make the method suitable for high-throughput tasks, such as genetic screening.

Alleles↗

Automated MMPI interpretation based on a modification of Gilberstadt's codebook.

Several limitations to commercially available automated MMPI reports prompted the psychology staff at Topeka VA Hospital to develop its own automated interpretive system. The computer programs of the system require further modification, and local validity studies of the automated interpretations are needed. However, it is hoped that this project will encourage others to consider the development of a local automated interpretive system as an alternative to commercial interpretive services.

Computers↗

Comparison of reagents for shape analysis of fixed cells by automated fluorescence microscopy.

BACKGROUND: Cell size and shape have been implicated as potentiators of intracellular signaling events and as indicators of abnormal cell behavior. Automated microscopy and image analysis can provide quantitative information about the size and shape of cultured cells, but it requires that the edge of a cell be clearly identified. Generating adequate contrast at the edge of thin well-spread cells can be challenging. METHODS: We compared six (five chemically reactive and one lipophilic) fluorescent molecules--5-chloromethyl fluorescein diacetate (CMFDA, CellTracker green), fluorescein-5-maleimide, fluorescein-5-isothiocyanate (FITC), 5-iodoacetamidofluorescein, 5(6)-carboxy fluorescein-N-hydroxysuccinimidyl ester, and N-fluorescein-1,2-dihexadecanoyl-sn-glycerol-3-phosphoethanolamine--for their effectiveness as stains for automated morphology analysis of fixed cells. RESULTS: Formaldehyde-fixed rat aortic smooth muscle cells stained with fluorescein-5-maleimide or FITC exhibited an average intensity that was at least twofold greater than cells stained with CMFDA even when subjected to a 25-fold shorter exposure time. Cell area determined with the higher intensity stains was less sensitive to threshold settings during automated cell morphology analysis. CONCLUSION: A procedure that includes the use of fluorescein-5-maleimide or FITC for staining fixed cell provides sensitivity sufficient to permit rapid, automated, morphologic analysis of well-spread fixed cells.

Animals↗