Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “atomic force microscopy”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36Linked to original sources

Effects of sodium hypochlorite and chlorhexidine solutions on Resilon (synthetic polymer based root canal filling material) cones: an atomic force microscopy study.

The aim of the present study is to evaluate the effects of 2% chlorhexidine and 5.25% sodium hypochlorite on the surface properties of Resilon cones with the atomic force microscopy. The Resilon cones were immersed in disinfecting agents (5.25% sodium hypochlorite and 2% chlorhexidine) at 1 and 5 min time intervals. Atomic force microscopy was used to evaluate topographical deviations of Resilon cones. Root mean square (RMS) parameters for topographic amplitudes were calculated. The cones exhibited statistically significant low RMS values at 5-min immersion in sodium hypochlorite and chlorhexidine groups compared to the all other groups (p < 0.05). One-minute immersion did not show any significant deterioration on the Resilon surface (p > 0.05). In conclusion, sodium hypochlorite and chlorhexidine solutions used for disinfection significantly decreased (p < 0.05) the RMS values of Resilon cones at 5-min applications.

Chlorhexidine↗

Static magnetic fields affect cell size, shape, orientation, and membrane surface of human glioblastoma cells, as demonstrated by electron, optic, and atomic force microscopy.

BACKGROUND: It is common knowledge that static magnetic fields (SMF) do not interact with living cells; thus, fewer studies of SMF compared with variable magnetic fields are carried out. However, evidence demonstrated that SMF affect cellular structures. To investigate the effect of exposure to increasing doses of SMF on cell morphology, human glioblastoma cells were exposed to SMF ranging between 80 and 3,000 G (8 and 300 mT). METHODS: Cell morphology of human glioblastoma cells, derived from a primary culture, was studied by electron and optic microscopy. FITC-phalloidin staining of actin filaments was also investigated. Finally, cell surface structure changes were detected by atomic force microscopy. RESULTS: Scanning electron microscopy demonstrated a dose-dependent cell shape modification, progressive cell detachment, loss of the long villi, and appearance of membrane roughness and blebs. FITC-phalloidin staining confirmed the villi retention and cell dimension decrease. At 3,000 G, the appearance of apoptotic morphology was also observed by transmission electron microscopy. Cell exposed to SMF showed different orientation and alignment when compared with nonexposed cells. The atomic force microscopy of the exposed cells' membrane surfaces demonstrated the disappearance of the ordered surface ripples and furrows typical of the unexposed cells, and the occurrence of surface membrane corrugation at increasing dose exposure CONCLUSIONS: Our experimental procedures demonstrated that exposure to SMF affects not only cell size, shape, and orientation but also human glioblastoma cells' membrane surfaces.

Apoptosis↗

Versatile cloning system for construction of multimeric proteins for use in atomic force microscopy.

This manuscript introduces a versatile system for construction of multimeric proteins to be used as substrates for atomic force microscopy. The construction makes use of a cassette system that allows modules to be cut and ligated in any combination in eight different positions. The modules can be sequenced in situ after construction. A three-module fragment can be produced that is of a size amenable to structural and biophysical analysis to check the effect of placing a protein into a multimeric construct. We show that if the parent titin modules are retained in a construct, they can act both as linkers and as an internal standard for the force measurements. Proteins that cannot be expressed solubly in an eight-module homopolymer have been expressed and subject to force measurements using this system.

Cloning, Molecular↗

Observation of the helical structure of the bacterial polysaccharide acetan by atomic force microscopy.

A method has been developed that has been found to give reproducible images of uncoated polysaccharides by Atomic Force Microscopy (AFM). Aqueous solutions of the polysaccharide are deposited as drops onto freshly cleaved mica surfaces, air dried, and then imaged under butanol. The method has been used to obtain images of the bacterial polysaccharide acetan. In regions within the deposited sample, where the molecules are aligned side-by-side, it has been possible to observe a periodic structure along the polysaccharide chain, attributable to the helical structure of acetan.

Acetobacter↗

[Investigation of ribosomes of E. coli and T. maritima by atomic force microscopy].

Subunits 70S, 50S, and 30S of ribosomes of E. coli and T. maritima have been studied by atomic force microscopy. A considerable heterogeneity of structures was visualized when 70S and 30S subunits were sorbed on mica. The linear size and the height of molecules were estimated. It was found that the heights of ribosomes of E. coli and T. maritima substantially differ. The average height of 70S ribosomes of E. coli was 9.4 + 0.01 nm and that of T. maritima was 10.35 +/- 0.02 nm. The differences in the dimensions were probably determined by special organization of the mobile ribosomal element the L7/L12-stalk.

Escherichia coli↗

Atomic force microscopy of nonhydroxy galactocerebroside nanotubes and their self-assembly at the air-water interface, with applications to myelin.

Myelin is one of the few biological membranes to contain the lipid galactocerebrosides, although their role in myelin is unclear. To explore its structural role, we used fluorescence and atomic force microscopy (AFM) to study nonhydroxy galactocerebrosides (NCer) at the air-water interface of a Langmuir-Blodgett trough. Fluorescence microscopy at the air-water interface indicated that NCer forms micrometer scale domains of varying radii with six fractal-like extensions. Atomic force microscopy using TappingMode in water on samples transferred to mica confirmed the fractal-like domain structure in the absence of dye and showed that the domains consisted of many aggregated nanotubes with a diameter of 30 nm. The Hausdorf fractal dimension was estimated to be 1.26 and 1.11 for two domains imaged with AFM. This evidence indicates that NCer forms a bulk phase of nanotubes at the air-water interface, unlike the liquid-condensed phase of a phospholipid monolayer. That NCer forms bilayer nanotubes that aggregate strongly suggests NCer helps maintain the stability of myelin by contributing to the curvature and adhesion of the membrane. We found that NCer appears to be decreased in myelin from multiple sclerosis normal appearing white matter, which could be an important event in the loss of myelin stability.

Air↗

Nanodissection of single- and double-stranded DNA by atomic force microscopy.

Nanodissection of single-stranded DNA (ssDNA) and double-stranded DNA (dsDNA) has been investigated by atomic force microscopy (AFM). It is found that both ss- and dsDNA can be repeatedly dissected by an AFM tip. However, a comparison study indicates that ssDNA is a little bit more easily broken by the AFM tip than dsDNA. This is supported by the fact that the time requested to break ssDNA is shorter than that of dsDNA in the same dissection procedure under the same load. Our experiment also shows that dissection of the DNA strand is very sensitive to the load applied, and a small change of the load lead to different results.

DNA↗

Atomic force microscopy of the erythrocyte membrane skeleton.

The atomic force microscope was used to examine the cytoplasmic surface of untreated as well as fixed human erythrocyte membranes that had been continuously maintained under aqueous solutions. To assess the effects of drying, some membranes were examined in air. Erythrocytes attached to mica or glass were sheared open with a stream of isotonic buffer, which allowed access to the cytoplasmic membrane face without exposing cells to non-physiological ionic strength solutions. Under these conditions of examination, the unfixed cytoplasmic membrane face revealed an irregular meshwork that appeared to be a mixture largely of triangular and rectilinear openings with mesh sizes that varied from 35 to 100 nm, although few were at the upper limit. Fixed ghosts were similar, but slightly more contracted. These features represent the membrane skeleton, as when the ghosts were treated to extract spectrin and actin, these meshworks were largely removed. Direct measurements of the thickness of the membrane skeleton and of the lateral dimensions of features in the images suggested that, especially when air dried, spectrin can cluster into large, quite regularly distributed aggregates. Aggregation of cytoskeletal components was also favoured when the cells were attached to a polylysine-treated substrate. In contrast, the membrane skeletons of cells attached to substrates rendered positively charged by chemical derivatization with a cationic silane were much more resistant to aggregation. As steps were taken to reduce the possibility of change of the skeleton after opening the cells, the aggregates and voids were eliminated, and the observed structures became shorter and thinner. Ghosts treated with Triton X-100 solutions to remove the bilayer revealed a meshwork having aggregated components resembling those seen in air. These findings support the proposition that the end-to-end distance of spectrin tetramers in the cell in the equilibrium state is much shorter than the contour length of the molecule and that substantial rearrangements of the spectrin-actin network occur when it is expanded by low ionic strength extraction from the cell. This study demonstrates the applicability of AFM for imaging the erythrocyte membrane skeleton at a resolution that appears adequate to identify major components of the membrane skeleton under near-physiological conditions.

Actins↗

Atomic force microscopy as an innovative tool for nanoanalysis of native stratum corneum.

This study demonstrates an innovative application of atomic force microscopy (AFM). The combination of high-resolution AFM technology and tape stripping is presented as a tool for the structure analysis of human stratum corneum (SC) at a nanometer scale. Topographic images with a vertical resolution of about 10 nm of the SC are presented. Topographical and structural differences between aged and young skin can be observed. Aged skin SC is characterized by an increased single-cell surface area, prominent intercellular gaps and enhanced cell surface roughness. The use of AFM in combination with other already established methods, e.g. tape stripping in the field of dermatological research will give new insights to the structure, function and morphodynamics of SC.

Adult↗

Chloroplast F0F1 ATP Synthase Imaged by Atomic Force Microscopy

The F0F1 ATP synthase of chloroplasts was imaged using atomic force microscopy (AFM) in contact mode under physiological conditions. Chloroplast (CF0F1) ATP synthases were reconstituted into liposomes. Liposomes were adsorbed on a mica surface where they spread and formed lipid bilayers containing CF0F1 ATP synthases which could be imaged. From these reconstituted CF0F1 ATP synthases, the CF1 part could be removed either by application of a chemical denaturant or less efficiently by mechanical stripping with the AFM tip. Embedded in the lipid bilayer were seen ring-like structures with a central dimple with outer diameters of 20 +/- 3 nm (chemical denaturant) and ca. 7 nm (mechanical stripping), respectively. Ring-like structures were also observed in a protein-free lipid bilayer. These had diameters of 30 +/- 5 nm and could be clearly distinguished from the structures observed after mechanical stripping. Hence, the ring-like structures observed after mechanical stripping might represent the intrinsic membrane domain CF0 or the oligomer of its subunit III. In addition, isolated CF1 adsorbed directly onto the mica surface was imaged. In accordance with the size known from electron microscopy, a diameter of 13 +/- 4 nm was measured.

Journal Article↗

In-plane contributions to phase contrast in intermittent contact atomic force microscopy.

Contrast in the phase response of intermittent-contact atomic force microscopy (IC-AFM) reveals in-plane structural and mechanical properties of polymer monolayers. This result is unexpected, as IC-AFM has previously only been considered as a probe of out-of-plane properties. Until now, AFM measurements of nanoscale in-plane properties have employed contact mode techniques. In-plane property measurements are possible with intermittent contact AFM because there is a small but significant component of tip motion parallel to the sample surface. This in-plane component of tip displacement is virtually universal in AFM, implying that oscillating-tip techniques generally are sensitive to in-plane material properties. We present a simple Hertzian model of intermittent-contact AFM that includes such an in-plane displacement.

Journal Article↗