Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Suction”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36Linked to original sources

Obesity can be treated by suction lipoplasty when combined with other procedures.

The development of serial suction lipoplasty enables us to remove substantial amounts of subcutaneous fat safely and dependably on an outpatient basis, and free our patients of the worry of exogenous blood transfusion. Many practitioners and researchers do not advocate suction for the treatment of obesity, but rather regard it as a means of treating localized small deposits of fat or "figure faults." The reason for their caution is that the amounts of fat to be removed from the obese patient would require extensive hospitalization, transfusion, and increased risk of complications. Liposuction, when performed as a series, can make the treatment of obesity as safe as the treatment of smaller figure faults. We now use serial suction as an adjunct to other surgical and dietary methods for the control of obesity.

Adult↗

Functional applications of suction-assisted lipectomy: a new treatment for old disorders.

Ever since the introduction of suction-assisted lipectomy in the United States in 1981, the technique has been applied to an increasing number of disorders of the subcutaneous tissues. Indeed, suction-assisted lipectomy has evolved into the method of choice in the treatment of certain pathological entities. While the extraction of lipomas is the most common functional application, suction-assisted lipectomy has also been used successfully to treat such conditions as gynecomastia, axillary hyperhidrosis, benign symmetric lipomatosis (Madelung's disease), congenital body asymmetry, congenital or acquired lymphedema, flap defatting, traumatic or postoperative hematomas, and fat necrosis. We have successfully treated patients presenting with the above disorders. No morbidities or mortalities were encountered in our series of 18 patients. The final results were considered favorable by the majority of patients. Acceptance by the patients of this treatment modality was extremely high because of the smaller incisions required, the exactness in contouring, the simple and minimal postoperative care needed, and the ease with which the procedure can be repeated to refine the results. A comprehensive review of the literature is presented along with our own patient management and long-term results.

Adult↗

Plasma and skin suction-blister-fluid pharmacokinetics and time course of the effects of oral mizolastine.

OBJECTIVE: To investigate plasma and skin suction-blister-fluid pharmacokinetics of oral mizolastine in order to determine whether the drug concentration in the fluid of suction-induced skin blisters could better predict the antihistamine activity than the plasma concentration. SETTING: Department of Internal Medicine, Université Paris 6. SUBJECTS: Ten healthy male volunteers. METHODS: The volunteers (mean age 26.8 years, mean weight 75.8 kg) received a single 10-mg oral dose of mizolastine at 1000 hours. The pharmacokinetic study included 11 plasma and 9 blister fluid samples and blister epidermal-roof specimens. Mizolastine was assayed by high-performance liquid chromatography (HPLC). Each volunteer also received nine intradermal injections of 5 micrograms histamine. Antihistamine activity was assessed as the post-treatment percentages of changes in the histamine-induced relative wheal and flare areas versus baseline. RESULTS: Mizolastine mean Cmax (SD) and median tmax were, respectively, 380 ng.ml-1 and 0.8 h in plasma, and 21.8 ng.ml-1 and 10 h in blister fluid. Mizolastine could not be quantified in the epidermis. The maximal histamine-induced relative flare inhibition was 72.5% and was attained at the median time of 3 h post-dosing and therefore was delayed by 2.2 h with respect to the plasma tmax. Mean relative wheal inhibition, although lower, showed the same time profile. A direct relationship could not be found between drug concentrations in blister fluid and antihistamine activity. Simulated concentrations in the peripheral compartment better explain the maximum inhibition effect on flare, observed 3 h post-dosing, with a flatter hysteresis loop obtained when plotting relative flare inhibition versus plasma or blister-fluid drug concentrations. CONCLUSION: The mizolastine concentrations in the skin suction-blister fluid were not predictive of the antihistamine activity.

Administration, Oral↗

Diastolic suction in the human ventricle: observation during balloon mitral valvuloplasty with a single balloon.

Diastolic suction has been demonstrated experimentally as a ventricular negative pressure when the ventricle is allowed to relax completely in the absence of filling, but it has not been extensively studied in the in vivo human heart. In balloon mitral valvuloplasty with a single balloon, the mitral orifice is occluded and inflow is considered to be completely obstructed during a balloon inflation. To demonstrate diastolic suction in the human ventricle, we measured left ventricular pressure during valvuloplasty with a high-fidelity catheter tip manometer in 17 patients. Left ventricular pressure fell below zero during a balloon inflation in all patients (-2 to -12 mm Hg). The peak negative diastolic pressure showed significant correlations with end-systolic volume index (r = 0.53, p = 0.03) and with the ejection fraction (r = 0.80, p = 0.0001). Thus diastolic suction was demonstrated in the human beating heart, and the sucking effect was potent in the heart with small end-systolic volume and high-ejection fraction.

Adult↗

Electrocardiographic changes induced by suction curettage for elective termination of pregnancy.

To determine if significant electrocardiographic changes occur during suction curettage for elective termination of pregnancy, continuous electrocariogram tracings were obtained from 103 patients prior to, during, and after suction curettage. Sixty-eight of 103 patients (66%) demonstrated transient sinus techycardia presumably attributable to pain (P < 0.001). Eleven of 103 patients (10.6%) demonstrated premature atrial contractions or premature ventricular contractions during suction curettage (P < 0.005). When more rigid (8 or 9 mm) curets were used, a threefold increased incidence of extrasystoles was noted. In a comparison of the incidents of electrocardiographic changes in parous versus nulliparous patients, no statistically significant differences could be demonstrated. (Unlike in previous published reports on intrauterine manipulation, bradycardia was not noted.)

Abortion, Induced↗

Unsuccessful eccentric perilimbal suction after filtering surgery.

Eccentric suction was applied over the surgical site in 47 eyes thought to have unsuccessful external filtering procedures. Referrals for suction were made either because the postoperative intraocular pressure was uncontrolled or because blebs were becoming progressively flatter. Patients had an average of seven such treatment sessions. No discernible benefit from eccentric suction in failing filtering surgery was noted one year postoperatively.

Epinephrine↗

Compound action potential of nerve recorded by suction electrode: a theoretical and experimental analysis.

Suction electrodes are widely used for recording compound action potentials (CAPs) from peripheral nerves or central tracts. Unfortunately, the recordings obtained with suction electrodes often vary over time, making quantitative measurement of CAP amplitude difficult. We developed an equivalent electrical model which predicts that the magnitude of a recorded potential will be linearly related to the resistance of the electrode with a nerve inserted. Mathematical procedures were developed that allow correction of virtually all variability inherent in this type of recording; this variability may arise from resistance drift, variable stimulus artifact, or potentials generated as a result of the current of injury. The validity of the theoretical analysis was confirmed experimentally using rat optic nerves. The magnitude of the CAP and electrode resistance varied spontaneously by as much as 100% over time, due to changes in electrode resistance and size of the stimulus artifact. Because the CAP was linearly related to resistance, it was therefore best quantified by the slope computed from this relationship. The stimulus artifact, unlike the CAP itself, was shown to be independent of recording electrode resistance and therefore only resulted in a variable offset to the area vs resistance linear relationship; the slope of this relationship was unaffected. In the absence of stimulation, a steady negative DC potential was recorded from the optic nerve, which was greatest immediately after dissection, and was also a linear function of electrode resistance. In contrast to CAP amplitude, the latencies of the component peaks within the CAP were not significantly altered by changes in electrode resistance. The experimental results confirmed the validity of the electrical model and demonstrated that suction electrodes can be a very reliable and quantitative recording method if the signals are properly corrected.

Action Potentials↗

Endometrial suction in luteal phase as a method of late postcoital contraception.

In a pilot study group of 25 women presenting in our clinic after exposure at ovulation to undesired pregnancy, endometrial suction by means of a Pipelle catheter was performed. Sixteen of the 25 women had proven fertility and 9 had never tried to conceive. The women were aged 18 to 38 years. Pathological dating of endometrial sampling verified that the patients were actually post-ovulation in all cases studied. hCG tests were performed 10 to 14 days after endometrial suction and all were negative. We conclude that endometrial suction in the luteal phase is a possible means of postcoital non-hormonal contraception, and we are currently expanding our study.

Adolescent↗

The effect of suction during die fill on a rotary tablet press.

Die fill on a rotary tablet press involves complex powder flow phenomena. Conventional techniques for measuring flowability do not normally provide information that is directly relevant to the design of powder feed systems or to the selection of press parameters for the die filling process. Sinka et al. [I.C. Sinka, L.C.R. Schneider, A.C.F. Cocks, Measurement of the flow properties of powders with special reference to die fill, in: International Journal of Pharmaceutics 280 (1-2) (2004) 27-38] used an experimental shoe-die system to characterise the flow behaviour of pharmaceutical powders. A rigorous data analysis procedure was developed by Schneider et al. [L.C.R. Schneider, I.C. Sinka, A.C.F. Cocks, Characterisation of the flow behaviour of pharmaceutical powders using a model die-shoe filling system, in: Powder Technology (in press)] to evaluate the experimental results, however, when scaling the results to a rotary tablet press, the die fill efficiency was underpredicted by a factor of approximately 2, because the experimental system did not capture major features of the rotary press flow process. The suction effect, whereby the lower punch is moved downwards while the top of the die is exposed to powder in the feed system, is a key element of the process. In this note we describe the development of a model shoe-die system that allows the effect of suction to be investigated. The results demonstrate the improvement offered by suction and illustrate how a fundamental understanding of die fill phenomena could assist the selection of process parameters to maximise the operational speed of a rotary press.

Cellulose↗

Treatment of viable cesarean scar ectopic pregnancy with suction curettage.

OBJECTIVE: Pregnancy in previous cesarean scar is the rarest form of ectopic pregnancy. All reported cases in the literature that were treated with uterine curettage either become unsuccessful or complicated. We aimed to present a case of cesarean scar ectopic pregnancy that was successfully treated with suction curettage without any additional therapy. CASE: A 32-year-old asymptomatic woman, gravida 2, para 1 was referred to our hospital with the possible diagnosis of cervical ectopic pregnancy. Transvaginal and transabdominal sonographic examination revealed the diagnosis of viable ectopic pregnancy in a previous cesarean scar. Suction curettage with carman canulles was performed under transabdominal ultrasonographic guidance. beta-hCG decreased progressively postoperatively. CONCLUSION: Suction curettage under ultrasonography guidance can be used in termination of selected cases (early diagnosed, without symptoms that necessitates emergency intervention) of cesarean scar pregnancy.

Adult↗

Is closed-suction drain necessary in unicompartmental knee replacement? A prospective randomised study.

In a prospective randomised trial we evaluated the use of a post-operative closed-suction drain in unicompartmental knee replacement (UKR). Seventy-eight patients were divided into two groups: one without a post-operative closed-suction drain (Group A) and one with a drain (Group B). Both groups were matched for age, sex and pre-operative haemoglobin. In group A we observed a lower day one post-operative analgesic requirement, smaller knee circumference 3 days post-operatively and less local wound complications. Drain usage in UKR resulted in no significant advantage in post-operative pain, range of motion and hospital stay. Post-operative drainage does, however, increase the cost of the procedure both in labour and equipment expenditure. No deep infections occurred in either group during the follow-up period. We conclude that avoiding post-operative closed-suction drainage in UKR does not influence the outcome.

Adult↗

Office hysteroscopy and suction curettage: can we eliminate the hospital diagnostic dilatation and curettage?

The hospital diagnostic dilatation and curettage is the most widely used method in investigating abnormal uterine bleeding. This procedure is expensive and inconvenient and poses some surgical and anesthetic risks. As an alternative to hospital dilatation and curettage, the procedure of office hysteroscopy and suction curettage was evaluated in 406 patients. The indications for the procedure are similar to the classic indications for a diagnostic dilatation and curettage. The method is convenient, safe, and relatively inexpensive. The diagnostic accuracy of office hysteroscopy and suction curettage surpasses prior reports of the accuracy of diagnostic dilatation and curettage. Office hysteroscopy and suction curettage should be the method of choice in the evaluation of abnormal uterine bleeding.

Adult↗

Incomplete and inevitable abortion: treatment by suction curettage in the emergency department.

Suction curettage for inevitable and incomplete spontaneous abortion has been performed by emergency physicians in the emergency department of the Central Group Health Hospital in Seattle for more than seven years. The equipment and techniques used in our practice are described, and guidelines for treatment are presented. Also presented is an analysis of 111 consecutive patients treated with suction curettage during an 18-month period with a minimum follow up of six months. The complication rate was minimal (4.5%), and compares favorably with previously published results of inpatient treatment. Several significant advantages of treating incomplete and inevitable abortion with suction curettage in the emergency department are described.

Abortion, Incomplete↗

Suction injuries in children leading to acute compartment syndrome of the interosseous muscles of the hand: case reports.

Compartment syndromes of the interosseous musculature in the hands of children is a relatively rare phenomenon and is usually associated with crush injury, severe burn, or ischemic events. Two cases of intrinsic compartment syndrome in children, secondary to suction injuries of the hand, are presented. Two children experienced suction injuries to the upper extremity when their hands were caught in a swimming-pool intake pipe filtration system. The filtration system intake suction developed enough negative pressure to induce an acute compartment syndrome of the interosseous muscles, requiring acute surgical decompression. Early diagnosis, prompt surgical decompression, and early postoperative rehabilitation of this unusual etiology of compartment syndrome of the hand provided a favorable and functional outcome.

Accidents↗

Cold water stress abolishes hyperactivity produced by cortical suction lesions without altering noradrenergic depletion.

The effect of forced cold water (15 degrees C) swimming on catecholamine depletions and behavioral hyperactivity produced by focal right hemispheric cortical suction lesions was assessed. Through the 30-day postoperative period, lesion and sham-operated control animals were placed in cold water for 5 min either four times at weekly intervals, once during the first postoperative week, or not at all. The effect of this cold water swim test was different for lesion and control animals. Stress at weekly intervals produced hyperactivity in control animals, but weekly stress in animals with focal suction lesions blocked the development of their expected hyperactivity. A single stress experience, 1 week postoperative, was also sufficient to block the development of hyperactivity in the lesion group. Stress, although affecting behavior, did not alter the pattern of norepinephrine depletions in animals receiving right hemispheric cortical suction lesions.

Animals↗

[Dual chamber safety vacuum--initial experiences with a new suction cup].

The main problem with vacuum extraction methods, alongside the cephalhaematoma produced, is the premature separation of the suction cup under traction, since the resulting sudden change in pressure can lead to severe intra-cerebral damage to the child. To reduce the risk of vaginal operative delivery, a new double-chamber safety vacuum extractor has been developed by Hepp/King. The basic feature of this instrument is an additional chamber with a thin overlapping area, which surrounds the actual suction cup and serves as a safety vacuum. If the suction cup starts to slip, the external vacuum is released and sounds an alarm. In addition, the inner vacuum has been designed to be convex and to reduce the volume of scalp, which is sucked into the vacuum, thus reducing the size of the cephalhaematoma produced. First experiences in clinical use demonstrated the reliability of the early warning signal, if the direction of traction is false or the applied traction is too strong. The inner vacuum remains constant at 0.8 atu, so that with care, the extraction can continue without interruption. We have used the new instrument in 18 deliveries. In 15 cases, the indication was failure to progress into the second stage of labour; in one case history of retinal detachment and in two cases signs of foetal asphyxia. In all cases, the child was delivered following one or two contractions with traction, without losing the vacuum. The average weight of the newborn was 3566 g. As expected, the cephalohaematoma produced was very much smaller than usual. Further clinical trials are necessary before the value of this new instrument can be assessed.

Asphyxia Neonatorum↗

Histochemical confirmation of the acetylcholinesterase-activity in rectal suction biopsy from neonates with Hirschsprung's disease.

Proliferating patterns of acetylcholinesterase (AChE) positive nerve fibres were investigated in 23 neonates with Hirschsprung's disease. All subjects were separated into three groups, according to age. In group A (0-10 days old) adn groups B (11-20 days old, no increase in AChE positive nerve fibres was evidenced in the lamina propria mucosae, whereas 7 out of 9 cases in group C (21-28 days old) showed a moderate or marked increase in AChE positive nerve fibres in the lamina propria mucosae. A typical pattern of this proliferation up to the lamina propria mucosae was seen in 30.4% only of all cases in the series, and was limited to group C, where the positive AChE reaction from the submucosa to the muscularis mucosae (including the submucosa only), the rate was 91.3%. Re-examination was preformed in 14 cases over sthe neonatal period. All showed a positive AChE reaction up to the lamina propria mucosae. Suction biopsy specimen from neonates is sometimes inadequate with respect to the lack of inclusion of the muscularis mucosae and submucosa, as a result of a weakly negative pressure by suction. The normal reactions of AChE activity in the lamina propria mucosae do not exclude Hirschsprung's disease in neonates. Therefore, when a histochemical diagnosis of Hirschsprung's disease using rectal suction biopsy for staining of AChE activity is required in the neonatal period, the diagnosis is safe and relatively easy at least over three weeks of age as mentioned above.

Acetylcholinesterase↗

Bronchopulmonary cross-colonization and infection related to mycobacterial contamination of suction valves of bronchoscopes.

Recurrent episodes of mycobacterial cross-contamination of bronchoscopy specimens were identified in a large, tertiary-care referral center. One episode was followed by active pulmonary infection due to Mycobacterium tuberculosis. Initial epidemiologic investigation implicated the flexible fiberoptic bronchoscopes. In experiments, bronchoscopes and related equipment were exposed to a saline suspension of M. fortuitum (10(5)-10(7)/mL). Bronchoscopes were readily sterilized by routine cleaning and disinfection procedures, but the spring-operated suction valves remained contaminated, even after a 30-min exposure to 2% glutaraldehyde or after passage through a commercial bronchoscope washer. These results indicate that suction valves that have been heavily contaminated with mycobacterial organisms cannot be reliably disinfected with commercially available glutaraldehyde. Suction valves have since been routinely autoclaved after each use. No additional episodes of cross-contamination or infection have occurred over 24 mo of surveillance.

Bronchoscopy↗