Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “SILICATE CEMENT”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36Linked to original sources

Electron beam irradiation of dental composites.

OBJECTIVES: Electron beam irradiation can be used to influence the mechanical properties of polymers. It was the aim of this study to investigate whether dental composites can benefit from irradiation in order to achieve increased fracture toughness, work of fracture, hardness or less wear. METHODS: Two hundred rectangular specimens of five veneering composites were electron beam irradiated with 25, 100 and 200 kGy using an electron accelerator of 10 MeV. Fracture toughness, work of fracture, Vickers hardness, color changes and three-medium wear were measured and compared with non-irradiated specimens. RESULTS: Visible color changes (DeltaE>3) were observed with all composites and with all dose rates. Fracture toughness, work of fracture, Vickers hardness and resistance against wear increased significantly with few exceptions. Composites with a simple curing process needed higher dose rates while systems with a more complex curing procedure should be irradiated with lower dose rates. SIGNIFICANCE: Electron beam irradiation can significantly change the mechanical properties of dental composites. However, color changes can limit the use of irradiation for dentistry.

Chemical Phenomena↗

Enamel fluoride uptake from orthodontic cements and its effect on demineralization.

This study was undertaken to determine the in vitro enamel fluoride uptake and distribution from fluoride-containing orthodontic cements after 21 days' exposure and the effect on acid demineralization. Three successive acid-etch biopsy specimens were taken from tne facial middle third of thirty maxillary central incisors. Orthodontic bands were cemented to these teeth, ten each with (A) zinc phosphate, (B) zinc phosphate containing 5 percent SnF2, and (C) silicophosphate cement, respectively. The teeth were suspended individually in synthetic saliva at 37 degrees C. in a shaking incubator for 21 days. The bands were removed, the cement was cleaned off, and three successive biopsies were carried out electrometrically and for calcium by atomic absorption spectroscopy. Fluoride concentrations were adjusted to depths of 10.0, 20.0, and 30.0 micron for the three biopsies, respectively. The acquired fluoride was calculated and the data were analyzed statistically. In addition, six teeth each with bands cemented with cements A, B, and C, respectively, were incubated in synthetic saliva for 21 days, after which the bands were loosened and the teeth were suspended for a further 3 months in a caries-producing medium. After careful cleaning, the enamel surfaces were examined by microradiography and scanning electron microscopy for demineralization. Results showed that acquired fluoride at the first depth was highest with cement C, followed by cement B, with cement A producing a net loss of fluoride. Further, the greater the fluoride uptake, the more resistant the enamel was to demineralization.

Dental Caries↗

Investigation of microleakage at the interface between a Co-Cr based alloy and four polymeric veneering materials.

STATEMENT OF PROBLEM: . Marginal adaptation and resistance to microleakage are important factors for clinical success in fixed prosthodontics. Alloy corrosion that sometimes occurs under a veneer in the cervical area may result in cervical staining, a metallic taste, or even failure of the interface. PURPOSE: This study investigated cervical microleakage between a Co-Cr alloy and 4 indirect polymeric veneering materials used with different conditioning systems. MATERIAL AND METHODS: Sixteen metallic frameworks (copings) were obtained by fabricating 0.6-mm calibrated wax patterns on a master cast abutment. The wax patterns were provided with 0.4-mm beaded retention on the veneering surfaces and cast in a Co-Cr based alloy (Biosil F) used for fixed partial dentures. The Co-Cr copings were divided equally into 4 groups and veneered with 4 polymeric materials (Signum, Solidex, Superpont C+B, and Targis). Three chemical conditioning systems (Siloc, Targis-Link, and Silicoater MD) were used with the respective veneering system recommended by the manufacturer; Conolar opaque was used for Superpont C+B. No control group was created. After 2 weeks of storage in distilled water at 37 degrees C, 2000 cycles at 5-55 degrees C, and 24 hours of storage in 0.5% basic fuchsine, specimens were embedded in clear liquid casting resin and sectioned along a perpendicular cervical-incisal plane through the middle of the cervical collar. The surfaces of the resulting sections were examined in the cervical area with a metallurgical microscope to detect dye penetration. Leakage was quantitatively evaluated with the use of a scoring system (established by the authors) that indicated the presence/absence of dye in 3 regions of the cervical interface from the collar to the incisal margin. Scores were compared and analyzed with the use of 1-way analysis of variance followed by post-hoc Tukey's honestly significant difference test (P=.05). RESULTS: Superpont C+B was associated with the highest microleakage scores (3.75 +/- 0.5). The least microleakage at the interface was produced by Targis (1 +/- 0.816), followed by Solidex (2.5 +/- 1.0) and Signum (2.25 +/- 0.975). Only the difference between Targis and Superpont C+B was significant (P<.05). CONCLUSION: Within the limitations of this in vitro study, the extent of cervical microleakage between the coping and veneer depended on the particular polymeric material used for veneering. The extremes of the study were Targis/Targis-Link (lowest leakage scores) and Superpont C+B (highest leakage scores). Differences among the chemical retention systems tested were not significant.

Analysis of Variance↗

In vitro wear of indirect composite restoratives.

STATEMENT OF PROBLEM: Indirect composite restoratives have been improved in their wear resistance and physical properties. Several new indirect composites claim to be successfully used for full coverage crowns, but there is limited information for wear values of these new indirect composites. PURPOSE: The purpose of this study was to evaluate the wear characteristics of 7 indirect composite restoratives and to compare them with a type III gold alloy by means of an in vitro wear test. MATERIAL AND METHODS: Seven indirect composites (2 photopolymerized and 5 photo/heat-polymerized types) and a type III gold alloy (control) were used. Cylindrical Class I cavities (4-mm diameter and 3-mm depth) were prepared in occlusally flattened extracted human molars. Inlays with respective materials were fabricated on duplicated stone casts according to the manufacturers' instructions. Three types of in vitro wear tests were completed by use of the University of Alabama wear simulator. The wear tests included generalized wear as simulation of the wear during mastication, localized wear as simulation of attrition by occlusal contact, and antagonistic enamel wear, which simulated the wear of enamel created by direct contact with the restorative materials. Seven specimens were tested for each material and wear mode, and the wear depths were measured on profilometric tracings with a 2-dimensional profilometer with 1-microm accuracy. All data were analyzed by 1-way analysis of variance, and multiple comparisons were performed with Fisher's test, for which the significant level was set at.05. RESULTS: The gold alloy control exhibited a very small amount of wear in both generalized wear (0.2 +/- 0.1 microm) and localized wear (13.8 +/- 5.0 microm) as compared with all composite specimens. The antagonistic enamel wear of gold alloy was similar with the value of Sculpture. The material group, which was post polymerized or post heat-treated, included BelleGlass, Sculpture, Estenia, and Cristobal+ and showed small values ranging from 1.6 to 2.2 microm in the generalized wear. For the localized wear, Estenia exhibited the minimum value (12.8 +/- 4.9 microm) that was statistically the same as the value of the gold alloy control. However, Estenia exhibited the greatest antagonistic enamel wear value (66.0 +/- 14.0 microm) of all materials tested in this study. It was statistically significant with other materials (P</=.05). CONCLUSION: Within the limitations of this study, it was concluded that some indirect composite restoratives have similar wear resistance to the type III gold alloy tested. Antagonistic enamel was abraded more by highly filled composite materials.

Analysis of Variance↗

The adaptation and sealing ability of light-cured glass ionomer retrograde root fillings.

The adaptation and sealing ability of a light-cured glass ionomer cement when used as a retrograde root filling was assessed using a confocal optical microscope with and without a fluorescent dye. This material was compared with a conventional glass ionomer cement and amalgam. The root canals of 60 extracted human single-rooted teeth were prepared and filled with gutta-percha and sealer. All the teeth were apicected, retrograde cavities were prepared, and then divided into three groups of 20 teeth each and filled with the test materials. The light-cured glass ionomer cement was well adapted to the retrograde cavity and apicected root surface. Within the retrograde cavity the cement was often well adapted to one wall, but gaps were found on the opposite cavity wall. This was probably caused by the polymerization contraction of the material. In contrast, the amalgam retrograde root fillings were poorly adapted to the cavities, with gaps between the cavity walls and amalgam. This group exhibited the poorest sealing ability as measured by the extent of dye penetration. The conventional glass ionomer cement was often found smeared over the root face, and there were unfilled voids at the base of some retrograde cavities. The results of the dye leakage study were analysed statistically. The sealing ability of the light-cured glass ionomer cement was significantly better than that of amalgam (P less than 0.001). The dye penetration around the light-cured glass ionomer cement and the conventional glass ionomer cement was not significantly different (P greater than 0.05). However, the sealing ability of the conventional glass ionomer cement was significantly better than that of amalgam (P less than 0.05).

Analysis of Variance↗

Bond strengths of two dental bonding systems.

A new bonding system named Kevloc has been introduced. It is based on acrylization of the metal surface with the goal of preventing the occurrence of a marginal gap between the metal and the resin. The purpose of this investigation was to determine the values of the shear bond strength achieved using the Kevloc technique on Ag-Pd (Auropal SE) and Co-Cr (Basil S) alloys and to compare them with those obtained with the OVS technique. The shear bond strengths were measured with the Smitz-Schulmayer shear test in a universal testing machine for polymer materials. A microscope image analyzer was used to measure the thickness of bonding layers and to reveal the possible occurrence of the marginal gap with both techniques. No marginal gap was detected with either technique. Kevloc provided better results than OVS only in a group of specimens tested after polymerization. Immersion in water and thermocycling reduced the initially high bond strength values of Kevloc specimens, whereas the bond strength values of OVS specimens remained unchanged regardless of which aging treatment was used. Microscopic examination did not reveal the existence of the marginal gap for either bonding system. According to the results obtained, it can be concluded that the Kevloc bonding system does not provide better shearing bond strength than the OVS bonding system.

Acrylic Resins↗

Use of photographs for communicating with the laboratory in indirect posterior restorations.

This article presents a single onlay case that was significantly enhanced through a detailed communication process between the clinician and the laboratory technician. By using colour slides as part of the dentist-technician communication process, the author found that the technician was better able to create an esthetic, accurate and successful restoration that addressed the patient's needs.

Adult↗

Adhesive properties of modified glass-ionomer cements.

The incorporation of water-soluble polymers and/or vinyl monomers into glass-ionomer cements can yield toughened "hybrid cement-composites". This study compared a commercial water-hardening glass-ionomer cement and seven experimental hybrids in their bonding to both dentin and Silar composite. The cements were sanded and phosphoric-acid-etched or left with an unaltered matrix-formed surface when adhesion to composite was tested. The seven hybrids included: 15% 2-hydroxyethyl methacrylate (HEMA) with appropriate initiators/activators, 29% HEMA, 27% HEMA + 0.5% polyacrylic acid (PAA), 0.5% PAA, 1.5% PAA, 2.5% polyvinyl alcohol, and 2.5% gelatin. Acceptable bond strengths to applied composite and to dentin were observed for most of the modified hybrid cements. There were higher bond strengths with composite when the hybrids were left unetched. Bonding of some unetched, HEMA-containing cements achieved bond strengths (29% HEMA, 10.09 MPa) significantly higher than those of the unmodified cement (4.92 MPa). Resin-modified cements may promote better bonding by improved interaction and compatibility with the resin component of the composite.

Acid Etching, Dental↗

Effect of cement type on retention of a tapered post with a self-cutting double thread.

OBJECTIVES: The aim of this in vitro study was to examine the effect of varying the cement type on the retention of a prefabricated tapered titanium post with a self-cutting double thread (Perma-tex activ). METHODS: A total of 130 suitable roots from extracted human permanent teeth were selected. Post holes were prepared using the instruments supplied with the post system. One-hundred-twenty posts (medium size) were luted with one of four luting agents: a zinc-phosphate cement (Harvard), a glass-ionomer cement (Ketac Cem), a compomer luting agent (Dyract Cem), and a new capsulated composite luting system (Compolute). The cement groups were subdivided into three treatment groups with 10 posts each: group 1 (4-week water storage at 37 degrees C), group 2 (4-week water storage at 37 degrees C, 4000 cycles 5-55 degrees C), group 3 (4-week water storage at 37 degrees C, 4000 cycles 5-55 degrees C, 3 x 4 min mechanical stress: 40N vibrations). Another 10 posts inserted without cement and stored like group 1 served as a control. Retention was measured on a universal testing machine (Zwick Z050/TH3A) with a crosshead speed of 0.1cm/min. Data were analyzed using ANOVA with a Bonferroni or Tamhane adjustment for multiple comparisons (significance level alpha=0.05). RESULTS: In group 1, Dyract Cem was significantly more retentive than the other three cements and the control group (no cement). In group 2, Compolute demonstrated significantly higher retention than Harvard and Ketac Cem. In group 3, Compolute, Dyract Cem, and Ketac Cem obtained higher retentive values than Harvard without differing from one another. Within the cement groups, thermocycling (group 2) caused a significant decrease in retention compared to group 1 only for Dyract Cem. All cements except Compolute were different from group 1 after a combination of thermocycling and mechanical stress (group 3). CONCLUSIONS: The retention of the tapered post with a self-cutting double thread was significantly influenced by the cement type used.

Analysis of Variance↗

Attritional wear and abrasive surface alterations of composite resin materials in vitro.

OBJECTIVES: A laboratory study was performed with 232 specimens and 72 human enamel, 24 gold, 24 ceramic and 12 composite antagonists in 22 groups to test attritional and abrasive wear behavior of composite materials compared to wear behavior of human enamel. METHODS: Belleglass HP, Concept Inlay/Onlay, Targis and Targis Upgrade 99 composite resin for lab-made restorations was tested as well as Tetric Ceram and FHC Merz light as resins for direct restorations. Natural human enamel specimens served as control. All specimens were subjected to long-term thermo-mechanical loading in a computer-controlled masticator, chemical degradation and toothbrush/toothpaste abrasion. Wear of specimen in occlusal contact area (OCA), contact-free occlusal area and wear of natural enamel cusps as well as antagonists made of gold, ceramic and composite in identical form was measured after 120,000, 240,000, 640,000 and 1200,000 load cycles. A qualitative SEM analysis was performed to support quantitative data. RESULTS: Belleglass HP and Targis Upgrade 99 restorative materials showed wear resistance comparable to human enamel when loaded with enamel cusps. Wear of Targis versus composite and gold antagonists was significantly higher (p<0.0001). Analysis of surface alterations showed hygroscopic expansion in all composite resins during the test. CONCLUSIONS: As a consequence of this study, necessity to further improve physical properties of composites for long lasting restorations was obvious. Beside of attritional wear in OCA, attention must be given to stable filler-matrix interfaces and prevention of water sorption.

Analysis of Variance↗

Adhesive bond of veneering composites on various metal surfaces using silicoating, titanium-coating or functional monomers.

OBJECTIVES: This study compared the shear bond strength (SBS) between veneering composites and titanium (grade 1), a cobalt-chromium-alloy and a high precious-alloy, which were pretreated using silicoating systems, functional monomers or an experimental titanium-dioxide coating system. METHOD: The specimens were sized to rectangular plates of 20 x10 x 2mm(3) (l,w,h) and a composite cylinder (height of 4mm, diameter 5mm) was axially polymerized to the middle of the plates. After aging (24h or 150 d storage in distilled water at 37 degrees C, or thermal-cycling: 6000 x 5 degrees /55 degrees C) the SBS was determined. RESULTS: Independent of the type of metal and the conditioning/coating techniques the lowest SBSs were found after thermal-cycling. Titanium. The SBS of the silica coating systems and the functional monomers did not differ statistically on titanium. However, the titanium-dioxide coating method had significantly higher values than the other methods. Cobalt-chromium. The highest mean values were observed with the titanium-dioxide coating system and the phosphate acid ester. Precious alloy. No statistical significant different SBS was found for the silicoating and the titanium-dioxide coating methods, while the functional monomers were statistically significant (lower) different to both systems. CONCLUSION: Generally, the titanium-dioxide coating system achieved the highest SBS under different aging conditions and on all three different metal-surfaces.

Adhesives↗

Abrasion resistance of restorative glass-ionomer cements with a light-cured surface coating.

This is a comparative study of the Knoop hardness number and the toothbrush wear of a surface coating agent applied to the surface of a glass-ionomer restorative cement. A reduction in surface hardness of the coating agent resulted in an increase in brush wear. The light-cured glazing agent (Bellfeel Brightener) proved to be significantly harder than those coated with a light-cured bonding agent (Occlusin). Occlusin bonding agent was removed by comparatively rapid abrasion; however, the Bellfeel Brightener was significantly more resistant to such abrasion. The analysis of the surface hardness and scanning electron microscopy observations of the brushed surfaces of the samples suggested that Bellfeel Brightener was effective as a glazing material for glass-ionomer cement restorations.

Composite Resins↗

Comparison of three types of fiber-reinforced composite molar crowns on their fracture resistance and marginal adaptation.

UNLABELLED: Three types of fiber-reinforced composite (FRC) molar crowns were tested on their fracture resistance and marginal adaptation under simulated oral stress conditions. Two glass fiber systems, one processed with a vacuum/pressure system, the other by manual fiber adaptation, and a polyethylene fiber system were evaluated. Every group consisted of 12 crowns. All crowns were luted adhesively on human molars and exposed to thermal cycling and mechanical loading (TCML: 6000 x 5 degrees C/55 degrees C; 1.2 x 10(6) x 50N; 1.66Hz). The marginal adaptation was evaluated through dye-penetration and analyzed semi-quantitatively with a scanning electron microscope. The fracture resistance was measured using a Zwick universal testing machine. The highest fracture resistance was observed on the glass-fiber systems (FibreKor/Sculpture 1875N +/- 596; Vectris/Targis 1726+/-542), though statistically, the polyethylene system (belleGlass/Connect 1388+/-620) was not significantly weaker. All systems exceeded the fracture resistance required to withstand the maximum masticatory forces expected in the molar region. The marginal adaptation generally had a tendency towards larger gaps after TCML. The crown/composite-cement bond deteriorated significantly after TCML with the manual fiber adaptation and the polyethylene fiber system. The cement/tooth bond strength depended on which composite-cement/dentin-adhesive system was used. CONCLUSION: The fracture resistance of molar crowns made of glass-fiber reinforced composite was higher than those of polyethylene fiber-reinforced composite crowns. However, there was no statistically significant difference. The marginal adaptation seems to depend on the fiber systems and composite-cement/dentin adhesive system used.

Analysis of Variance↗