Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “RADIOGRAPHY”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36Linked to original sources

Outcome of endoscopy and barium radiography for acute upper gastrointestinal bleeding: controlled trial in 1037 patients.

A study was conducted to find whether the higher diagnostic yield of endoscopy compared with barium radiography improves management or survival in patients with acute upper gastrointestinal bleeding. A total of 1037 patients were entered into a randomised study comparing the outcomes after each investigation. The diagnostic yield in patients who underwent endoscopy was 73% (382 of 526 cases) and in those examined by radiography 55% (280 of 511 cases). A fifth of the patients in the radiology group and a tenth of those in the endoscopy group subsequently underwent the alternative investigation; in most cases, however, no additional diagnostic information was obtained. Operation rates were similar in two groups, though patients in the endoscopy group were generally operated on sooner. Mortality rates were also similar in the two groups, though postoperative mortality was higher in the endoscopy group. Endoscopy may be a more accurate means of diagnosis than radiography, but it offers no short-term benefits in management.

Clinical Trials as Topic↗

Ultrasonography and abdominal radiography versus intravenous urography in investigation of urinary tract infection in men: prospective incident cohort study.

OBJECTIVES: To compare ultrasonography and abdominal radiography with intravenous urography in the investigation of urinary tract infection in men. DESIGN: Prospective study in two hospital departments. Radiological procedures and urological assessments performed on different days by different clinicians SETTING: District general hospital. PARTICIPANTS: Consecutive series of men (n=114) referred to the department of urology for investigation of proved urinary tract infection. INTERVENTIONS: Ultrasonography and intravenous urography of renal tract and assessment of urinary flow rate. Clinical assessment, cystoscopy, urodynamic studies, and transrectal ultrasonography with biopsy. MAIN OUTCOME MEASURES: Sensitivity and specificity of ultrasonography and abdominal radiography compared with intravenous urography. RESULTS: Important abnormalities were seen in 53 of 100 fully evaluated patients, the most common being a poorly emptying bladder (34). The combination of plain radiographs of kidneys, ureter, and bladder and ultrasonography detected more abnormalities than intravenous urography alone. No important abnormality was missed by this combination (sensitivity 100% and specificity 93%). CONCLUSIONS: Ultrasonography with abdominal radiography is as accurate as intravenous urography in detecting important urological abnormalities in men presenting with urinary tract infection. This combination is safer than intravenous urography and should be the initial investigation for such patients. Additional determination of urinary flow rate is useful for the assessment of an incompletely emptying bladder.

Adolescent↗

Cervical spine injuries to children under 11: should we use radiography more selectively in their initial assessment?

OBJECTIVES: To assess the effectiveness of cervical spine radiography in injured children under 11 years old, and suggest improvements. METHODS: Retrospective survey of radiographs and accident and emergency records for children examined during a one year period in a large teaching hospital. RESULTS: No cervical spine fractures occurred in this age group during the year. The recorded clinical findings did not always justify radiography. CONCLUSIONS: Clinical examination appears undervalued by those assessing injured children and is poorly recorded. Radiography can be used more selectively. Initial assessment using a single lateral projection can be followed in doubtful cases by cross sectional imaging.

Age Distribution↗

Estimation of cardiac chamber size by routine chest radiography and echocardiography.

The size of the left atrium and both ventricles was estimated by routine chest radiography and compared to echocardiographic single-chamber measurements. Left atrial size correlated well, but echocardiography appeared to be considerably more sensitive in detecting enlargement. Estimates of left ventricular size by radiography and echocardiography showed considerable discrepancy, since the single-dimension echocardiographic technique does not reflect lateral or inferior enlargement, which is readily visible on the radiography; however, ultrasound can distinguish left ventricular hypertrophy from dilatation. Right ventricular size cannot be assessed accurately using the single-diameter technique. The authors suggest that a combination of both techniques would be more accurate than either modality alone and that two-dimensional cardiac studies should prove more reliable than the single-diameter method.

Cardiomegaly↗

Radiation dose in hysterosalpingography: modern 100mm fluorography vs. full-scale radiography.

Radiation doses of modern 100mm fluorography and full-scale radiography were compared experimentally and applied to hysterosalpingography. It was determined that 100mm fluorography reduced the doses by 28-29% per exposure and 37-47% per examination compared with full-scale radiography performed with fast tungstate screens in identical conditions (70-80 kV, 400 mA). The dose during one minute of videofluoroscopy was equivalent to the doses produced by one exposure in full-scale filming and three to four exposures in 100mm filming. Although electronic magnification in 100mm fluorography increases the doses by two or threefold, these are still less than the doses in full-scale radiography.

Female↗

Laser alignment system for high-quality portable radiography.

In portable radiography, image quality is degraded by scattered radiation. Use of an accurately aligned, antiscatter grid can provide consistently high image quality, but the necessary precision for grid alignment is difficult to achieve with conventional techniques. The authors developed a simple laser alignment method for bedside radiography. A compact laser device is mounted on the collimator housing of a mobile radiography machine, so that the laser beam is precisely parallel to the central x-ray beam. A small reflector device, which attaches to the edge of the grid cassette, indicates beam centering and alignment in a clear, intuitive way. In clinical use, the laser alignment technique provided uniformly high image quality, equivalent to that of fixed equipment. The system has the advantages of being simple to use and inexpensive to implement with existing equipment.

Adult↗

Clinical experience with an advanced laser digitizer for cost-effective digital radiography.

Film digitization has not been widely pursued in clinical settings mainly because of perceived limitations involving film latitude and image quality. However, a high-quality laser digitizer can be combined with wide-latitude film and specially developed digital processing techniques to achieve image quality comparable or superior to that of storage phosphor computed radiography (SPR) over a wide range of exposure. This film digitization system provides the operational advantages of digital radiography, such as consistent image density, high-quality inexpensive duplicates, and digital storage and retrieval capability. The reliability and monetary costs of the system also compare favorably with those of SPR. In the long term, technologies that employ reusable plates and do not require chemical processing to produce diagnostic images may well replace screen-film systems. Presently, however, film digitization remains a practical and cost-effective approach to digital radiography.

Cost-Benefit Analysis↗

Comparative scatter and dose performance of slot-scan and full-field digital chest radiography systems.

PURPOSE: To evaluate the scatter, dose, and effective detective quantum efficiency (DQE) performance of a slot-scan digital chest radiography system compared with that of a full-field digital radiography system. MATERIALS AND METHODS: Scatter fraction of a slot-scan system was measured for an anthropomorphic and a geometric phantom by using a posterior beam-stop technique at 117 and 140 kVp. Measurements were repeated with a full-field digital radiography system with and without a 13:1 antiscatter grid at 120 and 140 kVp. For both systems, the effective dose was measured on posteroanterior and lateral views for standard clinical techniques by using dosimeters embedded in a female phantom. The effective DQEs of the two systems were assessed by taking into account the scatter performance and the DQE of each system. The statistical significance of all the comparative differences was ascertained by means of t test analysis. RESULTS: The slot-scan system and the full-field system with grid yielded scatter fractions of 0.13-0.14 and 0.42-0.48 in the lungs and 0.30-0.43 and 0.69-0.78 in the mediastinum, respectively. The sum of the effective doses for posteroanterior and lateral views for the slot-scan system (0.057 mSv +/- 0.003 [+/- standard deviation]) was 34% lower than that for the full-field system (0.086 mSv +/- 0.001, P < .05) at their respective clinical peak voltages (140 and 120 kVp, respectively). The effective DQE of the slot-scan system was equivalent to that of the full-field system in the lung region but was 37% higher in the dense regions (P < .05). CONCLUSION: The slot-scan design leads to marked scatter reduction compared with the more conventional full-field geometries with a grid. The improved scatter performance of a slot-scan geometry can effectively compensate for low DQE and lead to improved image quality.

Phantoms, Imaging↗

Multi-institutional analysis of computed and direct radiography: part I. Technologist productivity.

PURPOSE: To assess whether it is feasible to measure and compare work-flow times across institutional variations, and to apply such a comparison to technologist productivity in the performance of general radiographic examinations with computed radiography (CR) and direct radiography (DR). MATERIALS AND METHODS: The study received internal review board exemption. Participants were informed about the study and willingly participated. Observational time-motion analyses were performed at four sites at which CR and DR are used concurrently. The time taken by the technologist for patient preparation, positioning, exposure, and postacquisition processing, and for the examination as a whole, was recorded. Data collected reflect unique elements at each clinical center, and no standardized work flow was imposed. Work-flow performance times were correlated with each site profile. Preliminary statistical analyses included examination of distributions of original and combined variables. Descriptive statistics were presented as means or frequencies, depending on whether the data were continuous or categorical. Continuous variables were compared by using the Student t test. Timing differences between CR and DR for each clinical center were compared, and all data were analyzed by using commercially available statistical software. RESULTS: For all four study sites, statistically significant total examination time differences were observed when comparing CR and DR (P < .001). The single step in the examination that was found to be the largest contributor to time difference was postacquisition processing, which accounted for 30%-100% of the total time difference between the two technologies. The most time-efficient sites were those that had in-room postacquisition processing capability and fully functional integration with the radiology information system. Investigators at two study sites compared times for two-view chest radiography only, and those at the other two study sites compared times for multiview general radiographic examinations. Only the results of two-view comparisons were reported for each site. CONCLUSION: Overall technologist time was significantly shorter when performing tasks associated with DR than when performing comparable tasks associated with CR, a difference that appears to result largely from technology configuration, staffing, and patient management.

Efficiency↗

Multi-institutional analysis of computed and direct radiography: part II. Economic analysis.

PURPOSE: To compare economic aspects of equipment configurations, productivity levels, and patient waiting times in the performance of computed radiography (CR) and direct radiography (DR). MATERIALS AND METHODS: The study received internal review board exemption status, without the need for informed patient consent. Data from four study sites were used to calculate the CR-DR crossover point (defined as the point at which the cost-effectiveness of DR equals that of CR) and CR-DR annual cost differentials. Analyzed variables included equipment and operating costs, examination volumes, and productivity. A program was developed to simulate patient arrival times, number of patient examinations, and patient waiting times on the basis of average annualized parameters for each of the four clinics. Sensitivity analyses were conducted to assess utilization rates and determine cost optimization. Utilization rates were compared with the number of excess long-stay CR patients (ie, patients who spent more than 30 minutes waiting in the radiology department prior to CR examination) and with the cost (per excess long-stay CR patient who waited more than 60 minutes) averted by using DR. RESULTS: Excess annual costs for DR over CR at the four sites ranged from $50,757 to $75,303. At extrapolated levels of economic penalties for long waiting times, the crossover point at which the DR cost became justifiable was when CR capacity utilization rates approached or exceeded 80%. CONCLUSION: In the current practice environment, with capacity utilization rates well below 80%, CR is likely to be a more cost-effective technology for the majority of general radiography providers.

Costs and Cost Analysis↗

Radiography and US of os peroneum fractures and associated peroneal tendon injuries: initial experience.

PURPOSE: To retrospectively evaluate the imaging features of os peroneum fractures and associated peroneus longus tendon injuries at radiography and ultrasonography (US) and to retrospectively compare these imaging features with those of multipartite os peroneum. MATERIALS AND METHODS: Institutional review board approval was obtained and informed consent was waived for this HIPAA-compliant study. Retrospective review of findings in nine patients (five men, four women; age range, 35-59 years) with os peroneum fracture at radiography and lateral foot pain after injury who had undergone US of the foot was performed. Three patients underwent magnetic resonance (MR) imaging, and two underwent surgery. Os peroneum fragment separation and displacement relative to the calcaneocuboid joint were measured on radiographs. Os peroneum fracture and peroneus longus tendon injuries were characterized with US and MR imaging. Review of 43 foot radiographs obtained in 36 control subjects (eight men, 28 women; age range, 18-84 years) who were found to have an os peroneum at radiography but were asymptomatic in that area was completed to measure os peroneum distance from the calcaneocuboid joint and bipartite os peroneum fragment distraction. RESULTS: Os peroneum fragment separation of 6 mm or more or displacement of the proximal fragment by 10 mm or more on a lateral radiograph or 20 mm or more on an oblique radiograph was associated with full-thickness peroneus longus tendon tear in seven of seven patients (100%). Os peroneum fragment separation of 2 mm or less or proximal displacement of 8 mm or less was associated with normal tendons, partial-thickness tears, or tendinosis. In the control subjects, os peroneum location ranged from 7 mm proximal to 8 mm distal to the calcaneocuboid joint on lateral radiographs and from 9 mm proximal to 8 mm distal to the joint on oblique radiographs. Bipartite os peroneum fragment separation was 2 mm or less. CONCLUSION: Os peroneum fragment separation of 6 mm or more suggests os peroneum fracture and associated full-thickness peroneus longus tendon tear. Separation of 2 mm or less may be seen with nondisplaced os peroneum fractures and bipartite os peroneum.

Adolescent↗

An assessment of the contribution of chest radiography in outpatients with acute chest complaints: a prospective study.

The contribution of chest radiography to diagnosis was assessed in 1,102 consecutive patients with chest complaints at the Emergency Ward and Ambulatory Screening Clinic of a large hospital. The goal of this prospective study was to identify selective indications for chest radiography in this population with relation to the patient's age, the symptoms, and the results of physical examination. Although in patients over 40 years old chest symptoms are a sufficient indication for chest radiography, 96% of the patients below age 40 had a normal physical examination of the chest, no hemoptysis, and no acute radiographic abnormalities. If chest radiographs in the below-40 group had been limited to patients to patients with abnormal physical examinations and/or hemoptysis, 58% of the patients in that group would have been spared the examination. Under these conditions, 2.3% of the acute radiographic abnormalities in the entire population of patients under 40 would have gone undetected.

Adult↗

Detection of gastritis by single- and double-contrast radiography.

Sixty-eight patients with various types of gastritis, 23 patients with normal stomachs, and four patients with other gastric diseases were examined in a prospective study to assess the sensitivity and specificity of single-contrast (SC) and double-contrast (DC) upper gastrointestinal examinations in the evaluation of gastritis. All patients underwent endoscopy with biopsy followed first by DC and then by SC radiography. The respective sensitivities of SC and DC radiography were 58% and 72% for all examinations and 59% and 77% for adequate examinations only. The respective specificities were 59% and 55% based on all examinations. Both methods were slightly more sensitive in the detection of moderate-to-severe disease, with sensitivities of 60% for SC and 74% for DC examinations as compared with sensitivities of 53% for SC and 70% for DC in the detection of mild gastritis. Useful radiographic features included polypoid defects and erosions detected by both methods, abnormal folds and flattened margins detected by the SC technique, and narrowed lumen and crenulated margins detected by the DC technique. In 93% of all cases, the correct diagnosis was based on two or more of these radiographic features. According to this study, the radiographic sensitivity in the detection of gastritis is reliable only in cases of moderate-to-severe disease and only when based on findings of the DC examination. Neither SC nor DC radiography should be used as the primary screening method for patients with suspected gastritis, and the radiographic diagnosis should be restricted to the terms "erosive" or "nonerosive gastritis."

Adult↗

Preoperative chest radiography: value as a baseline examination for comparison.

An important use of the preoperative chest radiograph is as a baseline for comparison when complications occur after surgery. Many authors have commented on the value of preoperative chest radiography as a screening examination, but no statistics have been presented regarding its impact on postoperative management. In 369 consecutive general surgical patients, the need for a baseline chest radiograph was evaluated. In 65 patients undergoing chest radiography postoperatively, a preoperative baseline was essential in making an accurate interpretation in 33 (51%). The value of preoperative chest radiography proved to be twofold. Some minimal abnormalities on postoperative radiographs were demonstrated to be clearly new, necessitating treatment or further evaluation. Second, significant abnormalities detected on postoperative radiographs that may have otherwise been subjected to expensive evaluation were often shown to have been present preoperatively. In approximately 9% of patients the preoperative chest radiograph had a significant impact on postoperative management.

Adult↗

Artificial urinary sphincters: plain radiography of malfunction and complications.

Inflatable artificial urinary sphincters provide excellent voluntary continence. Eighty-four consecutive patients underwent implantation of artificial urinary sphincters for intractable urinary incontinence; 33 patients had 58 episodes of sphincter malfunction, and eight patients had eight complications involving a functional prosthetic sphincter. Retrospective analysis was performed to determine the value of plain radiography of the pelvis in patients with sphincter malfunction or complication. The cause of malfunction in the majority of patients was a system leak and subsequent loss of hydraulic fluid (31 occurrences; 53%). Plain radiography permitted correct identification of all instances of fluid leakage in patients with opacified prostheses. Plain radiographs were of no value in examining patients with nonopacified prostheses or the complications of cuff erosion or wound infection. Due to the low cost and noninvasive nature of plain radiography of the pelvis, we conclude that it should be used as the initial diagnostic modality in patients with previously opacified but currently dysfunctional artificial urinary sphincters.

Female↗

Improved pulmonary nodule detection with scanning equalization radiography.

The potential for improved pulmonary nodule detection with scanning equalization radiography (SER) was evaluated by means of observer performance testing during the interpretation of posteroanterior conventional radiographs and SER images of an anthropomorphic chest phantom with simulated nodules. A test set of 200 conventional and 200 SER radiographs of phantoms containing either one nodule or none was interpreted by four radiologists attempting to detect a nodule and indicate a confidence value. Their ability to detect nodules positioned over the lung was slightly improved with SER compared with conventional radiography (sensitivity, .56 vs .70); for nodules over the mediastinum or diaphragmatic areas, it was much improved (sensitivity, .29 vs .64). The results were also analyzed with receiver-operating characteristic methods, which revealed a significant improvement in lesion detect-ability over the thicker body parts with SER images. The capability of equalized chest radiographs to provide improved lesion detectability suggests that SER may set a new standard for film-based chest radiography and have a large clinical application.

Humans↗

Comparison of scanning equalization and conventional chest radiography.

A clinical comparison study of scanning equalization radiography (SER) and conventional chest radiography was performed with the latest prototype SER system. Conventional chest radiography was performed at 120 kVp with Lanex regular screens (Eastman Kodak, Rochester, NY) and Kodak Ortho-G or Ortho-C film (Eastman Kodak). The 253 volunteer patients were examined with both techniques. The chest radiographs were interpreted by four radiologists. The study group was composed of 58 normal and 195 abnormal posteroanterior and lateral chest radiographs. In 31 cases there were two major radiologic diagnoses. The number of correct interpretations increased when the SER images were examined, compared with the conventional Ortho-G (chi 2 = 4.17, P less than .05) and conventional Ortho-C (chi 2 = 16.9, P less than .001) radiographs. The overall accuracy of disease detection improved for all radiologists with the SER system. There was no disease category in which the accuracy of interpretation decreased when the SER system was used. The SER system is a clinically reliable method of improving image quality and increasing diagnostic accuracy.

Humans↗

Dynamic probabilistic model for determination of optimal timing of surveillance chest radiography in pediatric Hodgkin disease.

A dynamic probabilistic model based on hazard rate analysis, Monte Carlo modeling, and lead-time estimation techniques was developed to determine the optimal timing and frequency of chest radiography in the monitoring for relapse of children with treated Hodgkin disease. The analysis incorporates the performance characteristics of chest radiography, the natural history of the disease process, and therapeutic efficacy as a function of earliness of detection in the determination of optimal strategy. Examples of the model applied to the experiences of Stanford Medical Center and St. Jude Children's Research Hospital illustrate the utility of such a model in customizing an optimal monitoring strategy for a specific institution and clinical experience. The results suggest that monitoring protocols significantly overutilize chest radiography in the evaluation for recurrent Hodgkin disease in children.

Child↗