Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Pulse”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36Linked to original sources

Skills of lay people in checking the carotid pulse.

American Heart Association as well as European Resuscitation Council require the carotid pulse check to determine pulselessness in an unconscious victim and to decide whether or not cardiopulmonary resuscitation (CPR) should be initiated. Recent studies on the ability of health professionals to check the carotid pulse have called this diagnostic tool in question and led to discussions. To contribute to this discussion we performed a study to evaluate skills of lay people in checking the carotid pulse. A group of 449 volunteers (most had participated in a first aid course) were asked to check the carotid pulse in a young healthy, non-obese person by counting aloud the detected pulse rate. Time intervals until correct detection of the carotid pulse were registered. Overall the volunteers needed an average of 9.46 s, ranging from 1 to 70 s. Only 47.4% of the volunteers were able to detect a pulse within 5 s, and 73.7% within 10 s. A level of 95% volunteers detecting the pulse correctly was reached only after 35 s. Based on these findings we conclude that the intervals established for carotid pulse check may be too short and that perhaps the value of pulse check within in the scope of CPR needs to be reconsidered.

Adult↗

Determination of appropriate recording force for non-invasive measurement of arterial pressure pulses.

1. Non-invasive recording techniques of the arterial pressure pulse will distort the arterial wall and may alter pulse wave measurements. We hypothesized that intersubject variability of these measurements would be reduced if recording forces were normalized to reflect individualized arterial occlusion forces. 2. In 10 normal male subjects (age 24 +/- 1 years), brachial, radial and finger arterial pressure pulses were recorded simultaneously using volume displacement pulse transducers (Fukuda TY-303) and a finger pressure monitoring system (Finapres, Ohmeda 2300) and were made at 2, 5 and 10-100% (10% increments) of the brachial arterial force associated with marked distortion of finger pulsations. Forces were applied at the brachial site in a randomized order while a constant 1.8 N force was applied at the radial artery site. Pressure pulses were analysed using the discrete fast Fourier transform. 3. Pulse amplitude, contour, wave velocity and relative transmission ratios remained relatively constant until the branchial artery recording force exceeded 59.9 +/- 0.3% of the largest recording force used in each subject (7.14 +/- 0.75 N). The finger pulse pressures (P < 0.0001), radial pulse amplitudes (P < 0.0001) and contours (harmonics 2-6, P < 0.003), pulse wave velocity (P < 0.021) and relative transmission ratios (harmonics 3-7, P < 0.01) then decreased with higher recording forces. 4. To avoid distortion, non-invasive recordings of arterial pressure pulse amplitude, contour, pressure wave velocity and relative transmission ratios along a peripheral arterial segment should use recording forces of less than 60% of the force associated with marked distortion of finger pulsations.

Adult↗

Effect of destructive pulse duration on the detection of myocardial perfusion in myocardial contrast echocardiography: In vitro and in vivo observations.

UNLABELLED: Myocardial perfusion is detected with contrast echocardiography by comparing a contrast-enhanced image with a baseline obtained before contrast injection (true baseline) or after myocardial bubble destruction after a high-power destructive pulse (postdestructive pulse baseline). Although it is assumed that all bubbles are destroyed by a destructive pulse insuring optimal contrast detection, this assumption has not been tested. In 18 participants we compared the videointensity (VI) differences among the contrast-enhanced image, the postdestructive pulse baseline, and the true baseline using both triggered high-mechanical index imaging and real-time imaging. VI difference was significantly greater for the true baseline with both techniques at all ventricular levels. The benefit of using a true baseline was less when the duration of the destructive pulse was increased. Similarly, we quantified VI in a flow phantom using continuous Optison (commercially available perfluoropropane-filled albumin microbubbles) (Amersham, Princeton, NJ) infusion and variable durations of destructive pulses. VI decreased with the duration of the destructive pulse and reached a plateau after a duration of 8 to 15 frames. The plateau reached after a long destructive pulse was dependent on flow rate and concentration and never reached a true baseline, unless concentration (<100 microL/L) and flow rate (<0.5 cm/s) were very low. IN CONCLUSION: (1) in clinical studies, the difference in VI between contrast-enhanced and baseline images is greater when true baseline is used; (2) the longer the destructive pulse, the closer the postdestructive pulse baseline to true baseline; and (3) this effect exists in all regions of the left ventricle.

Adult↗

Influence of left ventricular filling profile during preceding control beats on pulse pressure during ventricular premature contractions.

We investigated whether the left ventricular filling profile, defined as the early to late diastolic left ventricular filling volume ratio, during the preceding control beats actually affects the pulse pressure during a ventricular premature contraction (PVC). Twenty patients underwent invasive electrophysiological study for sinus bradycardia. VPCs with various coupling intervals were induced by right ventricular electrical stimulation, and the mitral filling flow velocity by pulsed Doppler echocardiography, the femoral arterial pressure curve and the electrocardiogram were simultaneously recorded. The early to late diastolic velocity-time integral ratio (Ei/Ai ratio) of the mitral filling flow velocity during the control beats which preceded the VPC was measured as an index characterizing left ventricular filling profile. The coupling interval of each VPC and the extrasystolic beat pulse pressure were measured. The ratio of the extrasystolic beat pulse pressure to the control beat pulse pressure was expressed in % (% extrasystolic beat pulse pressure). The correlation between the coupling interval and the % extrasystolic beat pulse pressure was investigated. Coupling intervals of 0.80, 0.70, 0.60, 0.50, and 0.45 s were used. At a coupling interval of 0.80 or 0.45 s, the % extrasystolic beat pulse pressure showed no significant correlation with the Ei/Ai ratio. In contrast, the % extrasystolic beat pulse pressure with coupling intervals of 0.70, 0.60, and 0.50 s showed a significant positive correlation with the Ei/Ai ratio (r = 0.67, 0.74, and 0.66, P < 0.01, respectively). In addition to the prematurity and the site of origin of the VPCs, the left ventricular filling profile during the preceding control beats may significantly affect the height of the pulse pressure during extrasystoles with medium length coupling intervals.

Adolescent↗

Contour analysis of the photoplethysmographic pulse measured at the finger.

Analysis of the contour of the peripheral pulse to assess arterial properties was first described in the nineteenth century. With the recognition of the importance of arterial stiffness there has been a resurgence of interest in pulse wave analysis, particularly the analysis of the radial pressure pulse acquired using a tonometer. An alternative technique utilizes a volume pulse. This may conveniently be acquired optically from a finger (digital volume pulse). Although less widely used, this technique deserves further consideration because of its simplicity and ease of use. As with the pressure pulse, the contour of the digital volume pulse is sensitive to changes in arterial tone induced by vasoactive drugs and is influenced by ageing and large artery stiffness. Measurements taken directly from the digital volume pulse or from its second derivative can be used to assess these properties. This review describes the background to digital volume pulse contour analysis, how the technique relates to contour analysis of the pressure pulse, and current and future applications.

Blood Pressure↗

Variation associated with measurement of retinal vessel diameters at different points in the pulse cycle.

BACKGROUND/AIMS: To assess the variability in retinal vessel measurements at different points in the pulse cycle. METHODS: A healthy white male aged 19 years had 30 digitised images taken at three distinct points in the pulse cycle over a one hour period. A pulse synchronised ear clip trigger device was used to capture images at the desired point in the pulse cycle. Two trained graders measured the retinal vessel diameter of one large arteriole, one large venule, one small arteriole, and one small venule 10 times in each of these 30 images. RESULTS: Within an image, variability was similar between graders, pulse point, and vessel type. Across images taken at the same point in the pulse period, the change from the minimum to maximum measurement was between 6% and 17% for arterioles and between 2% and 11% for venules. In addition, measurements of small vessels had greater changes than large vessels and no point in the pulse period was more variable than another. Ignoring pulse cycle increased variability across images in the large venule, but not in the other vessel types. Mixed effect models were fit for each of the vessel types to determine the greatest source of variability. Controlling for pulse point and grader, the largest source of variability for all four vessels measured was across images, accounting for more than 50% of the total variability. CONCLUSION: Measurements of large retinal venules is generally less variable than measurements of other retinal vessels. After controlling for pulse point and grader, the largest source of variation is across images. Understanding the components of variability in measuring retinal vessels is important as these techniques are applied in epidemiological studies.

Adult↗

Long-term efficacy of dexamethasone-cyclophosphamide pulse therapy in pemphigus.

BACKGROUND: Corticosteroids are used as a daily oral therapy or in a pulse form with or without various adjuvant drugs for the treatment of pemphigus. Our long-term experience with the use of dexamethasone-cyclophosphamide pulse therapy as a first-line treatment modality for pemphigus is presented. METHODS: A retrospective analysis of records of pemphigus patients treated by dexamethasone-cyclophosphamide therapy was carried out. The treatment regimen consisted of the monthly administration of intravenous dexamethasone (136 mg) for 3 consecutive days with addition of intravenous cyclophosphamide (500 mg) on the second day. Oral cyclophosphamide (50 mg) daily and oral corticosteroids (low tapering doses) were given in the intervals between the pulses, till partial remission was achieved. Pulse therapy was then continued for another 6 months followed by daily oral cyclophosphamide (50 mg) for 1 year, which produced a complete remission. RESULTS: A total of 36 patients, 32 with pemphigus vulgaris and 4 with pemphigus foliaceus, were treated with this regimen. Two to 8 pulses were required to achieve a partial remission, while the total number of pulses given for complete remission ranged from 8 to 32. The duration of pulse therapy correlated with both the disease severity and the time to achieve remission. All patients are now in complete remission with a follow-up of 0.5-12 years. Four patterns of remission were observed, related to the severity of disease. The response to pulse therapy was faster in the milder form of disease. The severe form of disease required more pulses as well as higher doses of intervening oral corticosteroids. CONCLUSIONS: Dexamethasone-cyclophosphamide pulse therapy is an effective form of treatment in pemphigus and results in long-lasting remissions.

Adult↗

Association between local pulse pressure, mean blood pressure, and large-artery remodeling.

BACKGROUND: The aim of the present study was to determine the respective influences of local pulse pressure and mean blood pressure on arterial remodeling in humans at 2 arterial sites: a central, predominantly elastic artery (the common carotid artery) and a peripheral muscular artery (the radial artery). METHODS AND RESULTS: Forty-three healthy subjects and 124 never-treated hypertensive patients were included in the study. Intima-media thickness and internal diameter of the carotid and radial arteries were noninvasively determined with high-definition echo-tracking devices. Pulse pressure was measured locally with applanation tonometry. Multivariate regression models including mean blood pressure and local pulse pressure were established in the whole population. Carotid internal diameter and intima-media thickness were strongly influenced (P<0.0001) by carotid pulse pressure but not by mean blood pressure or brachial pulse pressure, independently of age and sex. Radial artery internal diameter was correlated with age but not with mean blood pressure or radial pulse pressure. Radial artery intima-media thickness was correlated with mean blood pressure (P<0.001) but not with radial pulse pressure. CONCLUSIONS: Carotid pulse pressure was a strong independent determinant of carotid artery enlargement and wall thickening, whereas mean blood pressure and brachial pulse pressure were not, indicating the prominent influence of local pulsatile mechanical load on arterial remodeling. These relationships were observed at the site of an elastic artery but not at the site of a muscular artery, suggesting the contribution of cyclic stretching to the pulse pressure-induced arterial remodeling.

Adult↗

Use of pulse transit time as a measure of inspiratory effort in patients with obstructive sleep apnoea.

Pulse transit time (PTT) is the time taken for the arterial pulse pressure wave to travel from the aortic valve to a peripheral site. For convenience, it is usually measured from the R wave on the electrocardiogram to the pulse wave arrival at the finger. Pulse transit time is inversely proportional to blood pressure, and the falls in blood pressure which occur with inspiration (pulsus paradoxus) correspond to rises (lengthening) in pulse transit time. In awake normal subjects, the size of these inspiratory rises in pulse transit time correlate well with the degree of inspiratory effort. The aim of this study was to investigate whether inspiratory rises in pulse transit time could provide a quantitative measure of inspiratory effort in patients with obstructive sleep apnoea. Eight patients with obstructive sleep apnoea, attending the laboratory for institution of nasal continuous positive airway pressure, took part in the study. Once asleep, airway pressure was varied between optimal treatment level and minimum pressure, to produce a range of inspiratory efforts whilst continuous recordings of oesophageal pressure and pulse transit time were made. There was an excellent correlation between the size of the swings in oesophageal pressure and the size of the swings in pulse transit time (mean r = 0.94). Pulse transit time may, therefore, provide a clinically useful noninvasive and quantitative measure of inspiratory effort in patients with sleep-related breathing disorders.

Adult↗

[Diagnostic value of the systolic part of the arterial pulse curve, registered using a bloodless technic].

Left ventricular contractility of 20 patients, measured by heart catheterization was compared with simultaneously but unbloody registrated pulse wave of A. carotis. Furthermore the crest time of femoralis and dorsalis pedis pulse wave was correlated to ejection time, pulse wave velocity, blood pressure and the length of the arteries between heart and foot of 1112 patients suffering from hypertension, arteriosclerosis, circulatory dysregulation and of 182 healthy sportsmen. The indices of left ventricular contractility: dp/dtmax, dp/dtmax/IP and t-dp/dt correlated highly significant with the time between the onset of the systolic upstroke and the first peak in the carotis pulse wave. No correlation was found with ejection time and the last systolic peak of the carotis pulse. Crest time is always shorter in the pulse wave of the foot arteries than in the femoral artery. The crest time in the femoral- and foot pulse correlates in all groups significantly with ejection time, patients with hypertension have the shortest, patients with arteriosclerosis the longest crest times, the last independent from the ejection time. The time between the start of the systolic upstroke and the first systolic peak in the unbloody registrated carotis pulse wave gives indication to the pressure development in the left ventricle. A long crest time in the peripheral pulse (pulsus tardus) is a typical symptom of generalized arteriosclerosis. The combination of slow pulse wave velocity in the leg and long crest time in the foot arteries (quotient greater than 20.5) indicates a stenosis in the arteries of the leg.

Adult↗

[Postural changes in finger and toe pulse waves].

Finger and toe pulse waves were simultaneously recorded in medical students and outpatient hypertensive patients. The delay of the rise of toe pulse to that of finger pulse (t) was almost halved in students on postural change from the supine position to the sitting position. This was mainly due to an increase in the pulse wave velocity in the aorta, which was thought to be induced by the increase in hydrostatic pressure in the aorta. In students a marked dicrotic wave was observed in both finger and toe pulse waves. That the interval between the main and dicrotic waves (T) was shorter for finger pulse than toe pulse also seems to be ascribable to the influence of the intraaortic pressure: Pulse was transmitted faster in the systolic phase than in the diastolic phase. The features of pulse waves of hypertensive patients were that (t) was short even in the supine position, and that dicrotic wave was small or absent especially for toe pulse. These differences were considered to be accounted for by the high blood pressure and the structural change of arterial wall in the hypertensive patients.

Aged↗

Should we palpate foot pulses?

UNLABELLED: Palpation of foot pulses is traditionally used to evaluate patients with arterial disease. This study investigated observer variation in assessment of pedal vessels by pulse palpation and Doppler auscultation. A series of 33 claudicant patients and five controls were examined by a consultant, registrar, SHO and nurse. Dorsalis pedis (DP) and posterior tibial (PT) pulses were palpated and were then examined by Doppler with measurement of systolic pressures. CONTROL GROUP: No disagreement in DP pulses. However, all observers agreed on the presence of a PT pulse in only 70% of limbs. Claudicants: There was better agreement in palpation of the DP pulse (all observers agreed in 67% of limbs), than the PT pulse (all agreed in 53%). This suggests that the DP pulse is easier to palpate than the PT (P less than 0.05). By contrast there was better agreement on Doppler signals from the PT artery, all agreed in 78% of limbs; compared with the DP artery, all agreed in 58% (P less than 0.01). Pressure measurements by the observers agreed to within +/- 0.15 in 88% of claudicant and 100% of control limbs. Pedal pulse palpation in patients with arterial disease is subject to substantial observer error. Doppler pressure measurement is preferable unless pulses are bounding.

Adult↗

Optimal truncation of defibrillation pulses.

The statement that the optimal pulse for defibrillation has not yet been discovered implies that an ideal pulse exists, but that it is different in shape, duration, and energy as compared to pulses of today. The optimum pulse is that which can defibrillate with lowest energy. Reduction of energy can be reached twofold: by looking for a pulse duration with lowest energy threshold, and by finding the optimal truncation with lowest refibrillating effect. Assuming that there is also a rheobase in defibrillation below which no defibrillating but probably a refibrillating effect exists, the exponential pulse should be truncated if it intersects with the rheobase. Combining the fundamental law of electrostimulation with this boundary condition allows for the mathematical solution of the above problem of optimal energy. Defibrillation can be optimized with respect to pulse duration or tilt and to energy efficiency. The most important parameter in determining other optimized parameters such as output capacitor is the chronaxie. The calculations reveal that the "concept of constant energy" does not accurately describe defibrillation, that today's implantable cardioverter defibrillator devices possess refibrillating tilts, that pulse durations should be programmed to values between 4 and 10 msec, and that smaller output capacitors around 30 microF would minimize the energy requirements. Whether optimized monophasic pulses are inferior or equal to biphasic pulses needs further experimental studies.

Defibrillators, Implantable↗

Association between pulse pressure and mortality in patients undergoing maintenance hemodialysis.

CONTEXT: Although increased blood pressure is associated with adverse outcomes in the general population, elevated blood pressure is associated with decreased mortality in patients with end-stage renal disease undergoing maintenance hemodialysis. Recent investigations in the general population have demonstrated the predictive utility of pulse pressure (systolic minus diastolic blood pressure), a measure reflecting the pulsatile nature of the cardiac cycle. OBJECTIVES: To estimate the relationship between pulse pressure and mortality in patients undergoing maintenance hemodialysis and to test our hypothesis that an increasing pulse pressure would be associated with increased risk of death up to 1 year despite the inverse relationship between conventional blood pressure measures and mortality in patients with end-stage renal disease. DESIGN, SETTING, AND PATIENTS: Retrospective cohort investigation of patients with end-stage renal disease undergoing maintenance hemodialysis at 782 hemodialysis facilities throughout the United States. Of 44 069 eligible patients as of January 1, 1998, 37 069 with complete demographic data were included in the analyses of clinical and laboratory data collected from October 1 through December 31, 1997. Patients were followed up through December 31, 1998. MAIN OUTCOME MEASURES: The primary study outcome was death at 1 year. A secondary outcome was the magnitude of the pulse pressure. RESULTS: The final patient cohort was similar to national averages with respect to age, sex, race, and diabetic status. Mean (SD) pulse pressures before dialysis were 75.0 (15.0) mm Hg and 66.9 (13.9) mm Hg after dialysis. By the end of the 1-year follow-up, 5731 patients (18.4%) died. After adjusting for level of systolic blood pressure, multivariable Cox proportional hazards modeling showed a direct and consistent relationship between increasing pulse pressure and increasing death risk. Each incremental elevation of 10 mm Hg in postdialysis pulse pressure was associated with a 12% increase in the hazard for death (hazard ratio, 1.12; 95% confidence interval, 1.06-1.18). Postdialysis systolic blood pressure was inversely related to mortality with a 13% decreased hazard for death for each incremental elevation of 10 mm Hg (hazard ratio, 0.87; 95% confidence interval, 0.84-0.90). In a multivariable linear regression model, important variables directly associated with elevated pulse pressure included age, diabetes, white race, female sex, and number of years receiving dialysis (all P<.001). CONCLUSIONS: Pulse pressure is associated with risk of death in a large, nationally representative sample of patients undergoing maintenance hemodialysis. The recognition of pulse pressure as an important correlate of mortality in patients receiving dialysis highlights the need to investigate the relationship between potential therapeutic implications of conduit vessel function and clinical outcomes in patients with end-stage renal disease.

Age Factors↗

Variable pulse erbium:YAG laser skin resurfacing of perioral rhytides and side-by-side comparison with carbon dioxide laser.

BACKGROUND AND OBJECTIVE: Laser resurfacing of facial rhytides has become a popular treatment option for many patients with wrinkles, photoaging, and acne scarring. Laser wavelength/pulse duration options and new techniques continue to shorten the healing phase associated with laser skin resurfacing while maintaining clinical efficacy. Variable pulse erbium:YAG (Er:YAG) laser systems are now available that offer the surgeon the ability to vary the Er:YAG pulse duration from a pulse that is primarily ablative to one that is more thermal. The objective of this study was to evaluate the histologic effects created with a variable pulse Er:YAG laser. To study prospectively the clinical effects on upper lip rhytides with a variable pulse Er:YAG laser when compared side by side with pulsed carbon dioxide (CO(2)) laser resurfacing. STUDY DESIGN/MATERIALS AND METHODS: Forty-two treatment sites on 21 patients were randomized and evaluated after treatment of the upper lip region with CO(2) laser resurfacing on one side and a variable pulse Er:YAG laser on the other. Patient diaries were maintained to assess erythema, crusting, pain, and pigmentary changes. Blinded objective grading of improvement was performed. Chromometer measurements were obtained to analyze erythema. RESULTS: The variable pulse Er:YAG laser treatment reduced the duration of crusting on average from 7.7 days with CO(2) to 3.4 days. Chromometer measurements noted decreased postoperative erythema. Grading by physicians in a blinded manner showed 63% improvement for the CO(2) treatment site and 48% improvement in the variable pulse Er:YAG site. No cases of permanent hyperpigmentation, hypopigmentation, or scarring occurred. CONCLUSION: The variable pulse Er:YAG laser resurfacing is a safe and effective resurfacing tool, which combines ablative and thermal modalities. The protocol used in this study approaches but does not equal the results we have traditionally seen with CO(2) laser resurfacing.

Carbon Dioxide↗

Electromagnetic pulse propagation in dispersive planar dielectrics.

The responses of a plane-wave pulse train irradiating a lossy dispersive dielectric half-space are investigated. The incident pulse train is expressed as a Fourier series with summing done by the inverse fast Fourier transform. The Fourier series technique is adopted to avoid the many difficulties often encountered in finding the inverse Fourier transform when transform analyses are used. Calculations are made for propagation in pure water, and typical waveforms inside the dielectric half-space are presented. Higher harmonics are strongly attenuated, resulting in a single continuous sinusoidal waveform at the frequency of the fundamental depth in the material. The time-averaged specific absorption rate (SAR) for pulse-train propagation is shown to be the sum of the time-averaged SARs of the individual harmonic components of the pulse train. For the same average power, calculated SARs reveal that pulse trains generally penetrate deeper than carrier-frequency continuous waves but not deeper than continuous waves at frequencies approaching the fundamental of the pulse train. The effects of rise time on the propagating pulse train in the dielectrics are shown and explained. Since most practical pulsed systems are very limited in bandwidth, no pronounced differences between their response and continuous wave (CW) response would be expected. Typical results for pulse-train propagation in arrays of dispersive planar dielectric slabs are presented. Expressing the pulse train as a Fourier series provides a practical way of interpreting the dispersion characteristics from the spectral point of view.

Adipose Tissue↗

Effect of adenosine on bicuculline-resistant paired-pulse inhibition in the rat hippocampal slice.

This study extends previous investigations into the effect of adenosine on bicuculline-resistant paired-pulse inhibition between field potentials evoked 300 ms apart in the CA1 area of the rat hippocampal slice. A direct assessment of the effect of adenosine on paired-pulse inhibition is complicated by the facts that adenosine directly depresses evoked potentials and bicuculline-resistant paired-pulse inhibition is greater between pairs of small potentials than between pairs of larger potentials. Adenosine increased bicuculline-resistant paired-pulse inhibition when stimulus strength was constant between adenosine and control but paired-pulse inhibition of responses in adenosine was markedly less than paired-pulse inhibition of control responses of the same size. Furthermore, adenosine decreased the size of conditioned potentials to a significantly lesser extent than unpaired potentials of the same initial size. Taken together the results indicate that adenosine can decrease bicuculline-resistant paired-pulse inhibition in the hippocampus. A possible mechanism for this effect is that adenosine is suppressing transmission at excitatory terminals onto interneurones which would suggest that these receptors are more sensitive to adenosine than those on the Schaffer collateral/CA1 pyramidal cell synapses. In this case adenosine should reduce paired-pulse inhibition at lower concentrations than are required for depression of single evoked potentials. A comparison of the concentration-response relationships for the effects of adenosine on paired-pulse inhibition and on single evoked potentials ruled out greater sensitivity of adenosine receptors at excitatory terminals onto interneurones as an explanation for adenosine's action on bicuculline-resistant paired-pulse inhibition.(ABSTRACT TRUNCATED AT 250 WORDS)

Adenosine↗

Improved solvent suppression and increased spatial excitation bandwidths for three-dimensional PRESS CSI using phase-compensating spectral/spatial spin-echo pulses.

Dual phase-compensating spectral/spatial echo-planar (EP) spin-echo (SE) pulses were incorporated into the point resolved spectroscopy (PRESS) excitation sequence to improve water and lipid suppression for 1H chemical shift imaging (CSI) and to decrease the dependence of the PRESS box location upon chemical shift. The asymmetric EPSE pulses (either minimum or maximum phase in the chemical shift domain) were substituted for the two PRESS SE pulses to yield zero phase spectra. Three different pulses were designed and tested at 1.5 T. Pulse 1, targeted for brain CSI (TE > 85 msec), passed choline to lipid resonances, suppressed water, and rephased the methyl lactate doublet independently of TE. Pulse 2, targeted for general purpose shorter TE PRESS, possessed both high chemical shift and spatial domain bandwidths. Pulse 3, designed for prostate CSI, passed choline to citrate resonances while suppressing lipids and water. The three pulses possessed spatial bandwidths ranging between 3.3 and 5.0 kHz, more than three times higher than that offered by one-dimensional SE pulses of equivalent maximum B1 amplitude. Phantom and in vivo experimental results demonstrated that, for EPSE pulses 1 and 2, suppression factors higher than 10(4) were achieved. The increased spatial bandwidths resulted in less contamination by signals from outside the designated PRESS excited region and a significant improvement in the uniformity of metabolite intensities for voxels located near edges of the PRESS box.

Aged↗