Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Polyacrylamides”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36Linked to original sources

Separation performance of single-stranded DNA electrophoresis in photopolymerized cross-linked polyacrylamide gels.

Considerable effort has been directed toward optimizing performance and maximizing throughput in ssDNA electrophoresis because it is a critical analytical step in a variety of genomic assays. Ultimately, it would be desirable to quantitatively determine the achievable level of separation resolution directly from measurements of fundamental physical properties associated with the gel matrix rather than by the trial and error process often employed. Unfortunately, this predictive capability is currently lacking, due in large part to the need for a more detailed understanding of the fundamental parameters governing separation performance (mobility, diffusion, and dispersion). We seek to address this issue by systematically characterizing electrophoretic mobility, diffusion, and dispersion behavior of ssDNA fragments in the 70-1,000 base range in a photopolymerized cross-linked polyacrylamide matrix using a slab gel DNA sequencer. Data are collected for gel concentrations of 6, 9, and 12%T at electric fields ranging from 15 to 40 V/cm, and resolution predictions are compared with corresponding experimentally measured values. The data exhibit a transition from behavior consistent with the Ogston model for small fragments to behavior in agreement with the biased reptation model at larger fragment sizes. Mobility data are also used to estimate the mean gel pore size and compare the predictions of several models.

Acrylic Resins↗

Polyacrylamide derivatives to the service of bioseparations.

Though acrylamide polymers are widely used in electrophoretic and chromatographic techniques, many research works aim at optimizing these media. As polyacrylamide presents some drawbacks, new acrylic monomers with particular properties are proposed. In this paper, we describe some approaches for obtaining polymers which are more porous, more hydrophilic and more resistant in alkaline solutions. Moreover, we also detail the synthesis of particular functionalized monomers, explaining the concept of 'polymer design' applicable to the techniques of protein separation.

Acrylic Resins↗

Method for long-term preservation of thin-layer polyacrylamide gels by producing a gelatine coating.

Thin-layer polyacrylamide gels can be preserved and stored for unlimited periods by covering them with a gelatine coating. The method is inexpensive and simple. After air-drying, the gel is immersed in an aqueous 10% solution of highly viscous gelatine between 55 and 60 degrees C. The coated gel is dried by hanging it in air. The method was checked successfully with gels of different thicknesses (0.15-0.50 mm) and after using different staining methods, e.g., with silver, Coomassie Brilliant Blue and pseudoperoxidase.

Acrylic Resins↗

Effects of linear polyacrylamide concentrations and applied voltages on the separation of oligonucleotides and DNA sequencing fragments by capillary electrophoresis.

Oligonucleotides and DNA sequencing fragments have been separated by capillary electrophoresis employing linear polyacrylamide (LPA) as a sieving matrix. A commercially available apparatus equipped with a laser-induced fluorescence (LIF) detection system has been utilized, but the capillary cartridge has been modified to position the capillaries without coiling. The performance of the separation, the relationship between resolution and analysis time, has been examined using poly(dT)16-500 by changing LPA concentration, capillary length, and electric field strength. It was found that, for large DNA fragments, the migration time interval between bands decreases linearly as DNA fragment size increases. This implies that there exists a maximum base number to be resolved, irrespective of the band width (we named the maximum base number Nmax). The higher value of Nmax is obtained when the applied field strength is lower, but this accompanies longer analysis time with a concomitant increase in band width. Simple experimental equations have been proposed to calculate resolution and migration times of DNA fragments separated in our system at given electrophoretic conditions. Using 9% T LPA and an electric field strength of 100 V/cm, single-base resolution of M13mp10 DNA fragments up to 520 nucleotides has been obtained.

Acrylic Resins↗

Routine DNA sequencing of 1000 bases in less than one hour by capillary electrophoresis with replaceable linear polyacrylamide solutions.

Long, accurate reads are an important factor for high-throughput de novo DNA sequencing. In previous work from this laboratory, a separation matrix of high-weight-average molecular mass (HMM) linear polyacrylamide (LPA) at a concentration of 2% (w/w) was used to separate 1000 bases of DNA sequence in 80 min with an accuracy close to 97% (Carrilho, E.; et al. Anal. Chem. 1996, 68, 3305-3313). In the present work, significantly improved speed and sequencing accuracy have been achieved by further optimization of factors affecting electrophoretic separation and data processing. A replaceable matrix containing a mixture of 2.0% (w/w) HMM (9 MDa) and 0.5% (w/w) low-weight-average molecular mass (50 kDa) LPA was employed to enhance the separation of DNA sequencing fragments in CE. Experimental conditions, such as electric field strength and column temperature, as well as internal diameter of the capillary column, have been optimized for this mixed separation matrix. Under these conditions, in combination with energy-transfer (BigDye) dye-labeled primers for high signal-to-noise ratio and a newly developed expert system for base calling, the electrophoretic separation of 1000 DNA sequencing fragments of both standard (M13mp18) and cloned single-stranded templates from human chromosome 17 could be routinely achieved in less than 55 min, with a base-calling accuracy between 98 and 99%. Identical read length, accuracy, and migration time were achieved in more than 300 consecutive runs in a single column.

Acrylic Resins↗

Replaceable cross-linked polyacrylamide for high performance separation of proteins.

An alternative sieving matrix, replaceable cross-linked polyacrylamide (rCPA), was developed for sodium dodecyl sulfate capillary gel electrophoresis (SDS-CGE) separation of proteins. This rCPA could be conveniently pressurized into separation capillaries under a pressure of 80 psi. SDS-CGE separations using this matrix generated high resolutions for a wide range (approximately 4 kD to approximately 300 kD) of proteins. When compared to the most frequently used sieving matrixes, the rCPA permitted the highest resolutions with comparable or increased separation speed for protein separations.

Acrylic Resins↗

Reuse of denaturing polyacrylamide gels for short tandem repeat analysis.

Denaturing polyacrylamide gel electrophoretic analysis of amplified polymorphic short tandem repeat (STR) loci using fluorescent markers is a mainstay of forensic and paternity testing. To reduce the drawback of preparing gels or using expensive precast gels, we have developed a simple and rapid method to reuse gels between 2 and 8 times over a period of several days. Following the initial electrophoresis and scan, the original samples are removed from the gel by a 1-1.5-h reverse-electrophoresis step. This step heats the gel for the next set of samples and can be performed several days after the initial electrophoresis. Sample bands remain sharp on subsequent runs, but edge effects (frowning of the outside lanes) become progressively worse and ultimately limit gel reuse. Well distortions and separation of the gel from the plates become problems if the gel is used more than twice. However, degassing the gel solution and bonding the gel to both plates eliminate these problems. Precast gels also can be used multiple times. Using this technique, we have successfully analyzed samples amplified with a nine-locus multiplex system and characterized the separated products using a fluorescent scanner and software.

Acrylic Resins↗

Modified polyacrylamide microspheres as immunosorbent.

Extracorporeal immunoadsorption system has been used for the specific removal of immunologically active substances from the blood. In this study, an attempt is made to utilise polyacrylamide microspheres as a matrix for immunoadsorption. Phenyl alanine is coupled onto the polymer beads using glutaraldehyde. These modified beads exhibit a high binding affinity for gamma-globulin compared to bare beads. The surface modified ones showed selective adsorption of immunoglobulins of IgG class. The C3 adsorption pattern is not altered significantly upon modification. Modified beads are found to be less hemolytic after modification. However, more studies are to be conducted for the development of a hemoperfusion column based on this modified matrix.

Acrylic Resins↗

Production of polyacrylamide gradient gels for the electrophoretic resolution of lipoproteins.

We describe a protocol to cast nondenaturing polyacrylamide gradient gels (SFBR3/31) for the size resolution of lipoproteins. The protocol yields gels with minimal lot-to-lot variation in length and electrophoretic properties. Absorbance profiles of cholesterol-stained lipoproteins in baboon sera were used to estimate the relative amounts of stain in four lipoprotein size classes (VLDL+LDL, HDL1, HDL2, and HDL3). When compared with gels from a commercial source, the SFBR3/31 gels gave very similar results in terms of precision (coefficients of variation) and of estimated amounts of lipoproteins in the four size classes. In other studies, we estimated peak diameters of protein-stained human lipoproteins after calibrating the gels with size standards. Peak diameters estimated using SFBR3/31 gels were highly correlated (r2 = 0.99, n = 33) with those estimated using gels from a commercial source. We conclude that the protocol reliably produces gradient gels that are suitable for the analysis of lipoprotein phenotypes.

Acrylic Resins↗

Micromethod for detection of oligoclonal IgG in unconcentrated CSF by polyacrylamide gel electrophoresis.

A micromethod to detect oligoclonal IgG from 50 microL of unconcentrated CSF was developed by using polyacrylamide gel electrophoresis in sodium dodecyl sulfate (SDS-PAGE). Of 17 patients with multiple sclerosis, oligoclonal bands were demonstrated in 16 instances (94%) by micro-SDS-PAGE and in 13 (76%) by agarose gel electrophoresis. The corresponding figures among 30 patients with optic neuritis were 16 (54%) and five (17%), respectively, and among ten patients with other neurological disease the figures were two (20%) and none, respectively. Thus, micro-SDS-PAGE is more sensitive than agarose gel electrophoresis for detection of oligoclonal IgG. The small volume of unconcentrated CSF that is required enhances the usefulness of this test.

Adolescent↗

Matrix-assisted laser desorption/ionization mass spectrometric peptide mapping of the neural cell adhesion protein neurolin purified by sodium dodecyl sulfate polyacrylamide gel electrophoresis or acidic precipitation.

Neurolin is a cell surface protein involved in the neural regeneration and neogenesis of the central nervous system of goldfish. Its theoretical molecular mass, based on the amino acid sequence translated from the cDNA, is 58 kDa, but in SDS-PAGE it shows an apparent MW of 86 kDa. Neurolin is stated to be a glycoprotein and it contains five potential N- and 96 potential O-glycosylation sites. The complete characterization of the primary structure and initial investigations on the postulated glycosylation of neurolin, immunopurified from goldfish brains, are described. The protein was either digested in situ in the sodium dodecyl sulfate polyacrylamide gel matrix or digested after trichloroacetic acid precipitation. Trypsin and endoprotease Glu-C were used as proteases and matrix-assisted laser desorption/ionization mass spectrometry was applied for direct peptide mapping analysis of the proteolytic mixtures. Various sample preparation techniques were performed and the mass spectra were recorded in both positive- and negative-ion modes.

Activated-Leukocyte Cell Adhesion Molecule↗

Matrix-assisted laser desorption/ionization mass spectrometry of proteins extracted directly from sodium dodecyl sulphate-polyacrylamide gels.

A new strategy for the characterization of Coomassie Brilliant Blue stained SDS-PAGE separated proteins by UV-MALDI-MS is reported. The proteins are extracted directly from the polyacrylamide gel by treatment with an organic solvent mixture consisting of formic acid, acetonitrile, isopropanol and water in an ultrasonic bath. A fraction of the supernatant is then mixed directly with the matrix solution and measured by MALDI-MS. High quality spectra could be obtained from gels which were loaded with 6 pmol of myoglobin. Compared to other methods based on electroblotting or electroelution this method is much simpler and less time consuming. The sensitivity is higher than or comparable to the Coomassie Blue staining procedure for proteins up to about 25 kDa. Another advantage is that mass shifts due to charging effects of the membranes, which are common if membranes are mounted directly on the sample target, can be avoided. However, all proteins studied showed slightly higher masses than expected which reduces mass accuracy to 0.2-0.3%. This is presumably partly due to formylation of serine or threonine residues during incubation in formic acid. Gel electrophoresis induced modifications can contribute as well. The possibility of further characterizing the remaining part of the supernatant after extraction by means of proteolytic digestion is also demonstrated. The knowledge of both molecular weight of the whole protein and of the proteolytic fragments increases specificity for protein identification by searching in sequence databases.

Carbonic Anhydrases↗

Capillary electrophoresis/tandem mass spectrometry for analysis of proteins from two-dimensional sodium dodecyl sulfate polyacrylamide gel electrophoresis.

Capillary electrophoresis/time-of-flight mass spectrometry(CE/TOFMS) has been used for analysis of in-gel digests of protein spots excised from two-dimensional sodium dodecyl sulfate polyacrylamide gel electrophoresis (2-D SDS-PAGE). An off-line purification and preconcentration procedure with a Zip Tip is used before CE/TOFMS analysis which allows for detection of protein spots with <1 picomole of material from 2-D gels. The off-line procedure provides sufficient purification for analysis while maintaining the quality of the CE separation. Using this procedure, several proteins from Coomassie Blue and zinc negatively stained gels are identified by the peptide maps generated and database searching. CE/TOF tandem mass spectrometry is used for the confirmation of database searching results and structural analysis of peptides that do not match the expected peptide maps obtained from the database in order to identify structural modifications. Several modifications were pinpointed and identified by this method.

Adenocarcinoma↗

Effect of experimental conditions on the analysis of sodium dodecyl sulphate polyacrylamide gel electrophoresis separated proteins by matrix-assisted laser desorption/ ionisation mass spectrometry.

Two mixtures of proteins having molecular weights in the range approximately 8-97 kDa were separated by sodium dodecyl sulphate polyacrylamide gel electrophoresis (SDS-PAGE) and examined by delayed extraction matrix-assisted laser desorption/ionisation mass spectrometry (MALDI-MS). Part of our aim in this study is to gain more insight into the influence of the various experimental conditions on the overall quality of the acquired mass spectral data. Different protein extraction procedures, two staining agents, and extraction times, were among the parameters assessed. In terms of the overall quality of the acquired mass spectra and the speed of protein recovery, ultrasonic assisted passive elution, into a solvent mixture containing formic acid/acetonitrile/2-isopropanol/water, was found to be more efficient than other elution procedures. The higher resolution associated with the delayed extraction mode allowed the identification of a number of protein modifications, including multiple formylation provoked by formic acid, cysteine alkylation caused by unpolymerised acrylamide monomers, and complexation with the staining reagents. The detection of these modifications, however, was limited to proteins under 30 kDa. Analysis of a ubiquitin tryptic digest by reflectron MALDI time-of-flight (TOF) allowed reliable identification of a number of the formylation sites.

Animals↗

The use of polyacrylamide-based peptide synthesis resins for the generation of antipeptide antibodies.

Antibodies directed against specific amino acid sequences can serve as probes for the protein molecules from which the sequence was derived, as well as affinity purification reagents. One of the major uses of synthetic peptides is for the production of such antibodies. Typically, antigens for this purpose are prepared by coupling the peptide to a macromolecular carrier such as bovine serum albumin or keyhole limpet hemocyanin. The steps for this process are peptide synthesis, peptide purification or desalting, coupling to the carrier protein, and purifying the peptide-protein conjugate. Techniques have emerged in which the amino acid sequence of interest is synthesized on a solid support using a noncleavable linkage and the resulting peptidyl-resin is injected into animals to elicit the antipeptide immune response. These procedures reduce the number of steps required to prepare the peptidyl-antigen. Water-compatible resins based on polyacrylamide have been utilized for this purpose. In this paper the composition of these supports and their use in the generation of antipeptide antibodies is reviewed.

Acrylic Resins↗

Novel application of PhastSystem polyacrylamide gel electrophoresis using restriction fragment length polymorphism--internal transcribed spacer patterns of individuals for molecular identification of entomopathogenic nematodes.

différences! [editorial] [editorial]onomic way of identifying and assigning nematodes to taxons, which had already been determined either by comparative sequence analysis of nuclear rDNA internal transcribed spacer (ITS) region or by other methods of molecular or conventional taxonomy, is provided. Molecular identification of entomopathogenic nematodes (EPN) can be upgraded by basing it on PhastSystem polyacrylamide gel electrophoresis (PAGE) analysis of restriction fragment length polymorphism (RFLP) patterns of polymerase chain reaction (PCR)-amplified DNA derived from single nematodes of Steinernema or Heterorhabditis spp. Although analysis from single worms has previously been made on agarose gel, the resolution on PhastSystem PAGE gel is much higher. The DNA sequences selected for analysis were those constituting the internal transcribed spacer region between the 18S and 26S rDNA genes within the rRNA operon. RFLP analysis was carried out by gel electrophoresis on the PhastSystem (Pharmacia) as detailed elsewhere (Triga et al., Electrophoresis 1999, 20, 1272-1277. The downscaling from conventional agarose to PhastSystem gels resulted in pattern of DNA fragments differing from those obtained with agarose gel electrophoresis under conventional conditions by increasing the number of detected fragments. The approach supported previous species identifications and was able to identify several unclassified isolates, such as those from Hungary and Ireland, and provides a method for identification of previously unclassified strains. We confirmed that Heterorhabditis "Irish Type", represented by two strains of different geographical origin, comprise a species different from H. megidis. We also confirmed that strain IS5 belongs to the species H. indicus rather than to H. bacteriophora, as had been suggested previously.

Animals↗

Detection of protease activities using specific aminoacyl or peptidyl p-nitroanilides after sodium dodecyl sulfate - polyacrylamide gel electrophoresis and its applications.

A general method for detecting protease activities on acrylamide or agarose gels after sodium dodecyl sulfate - polyacrylamide gel electrophoresis (SDS-PAGE) using specific aminoacyl p-nitroanilide (NA) or peptidyl NA as substrate is described. This method is extended from the spectrophotometric assay of p-nitroaniline, which is a chromogenic product liberated by protease action on aminoacyl NA or peptidyl NA. The acrylamide gel containing protein bands was dipped directly into a solution which contained specific synthetic aminoacyl NA or peptidyl NA as a substrate or had been overlaid with an agarose gel containing the same substrate. The p-nitroaniline released on the acrylamide or agarose gel by the specific protease was diazotized with sodium nitrite and then coupled to N-(1-naphthyl)-ethylenediamine to produce distinct activity band(s). The substrates used for protease activity staining on gels were identical to those used for spectrophotometric assays. Some applications are described.

Benzoylarginine Nitroanilide↗

Development of a sodium dodecyl sulfate-polyacrylamide gel electrophoresis reference method for the analysis and identification of fish species in raw and heat-processed samples: a collaborative study.

A collaborative study was carried out in seven European labs with the aim of achieving a sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) standard operation procedure to identify fish species in raw and cooked samples. Urea and SDS-containing solutions were evaluated as extractants. Several preelectrophoretic operations--such as treatment with RNase/DNase, ultrafiltration and desalting--and up to ten types of gels and three SDS-PAGE systems were considered. The SDS-containing solution allowed a higher protein extractability than urea. Unlike urea extraction, SDS extraction seemed not to be influenced so much by the state of the sample (raw, cooked at 60 degrees C, cooked at 85 degrees C). Desalting, ultrafiltration or treatment with RNase/DNase did not improve the discriminatory power of the protein patterns. Commercial homogeneous 15% ExcelGels, especially when they were silver stained, yielded good results and afforded higher reproducibility, thus allowing a better matching of results among the laboratories participating in this collaborative study. Under the optimized technical conditions described above, all the fish species tested, either raw and cooked, yielded reproducible and discriminant species-specific protein patterns.

Animals↗