Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Motion”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36Linked to original sources

Letter recognition reveals pathways of second-order and third-order motion.

How are second-order (texture-defined) and third-order (pattern-tracking) motions processed in our brains? As shown here in the context of an ambiguous motion task involving a nominal second-order stimuli first devised by Werkhoven et al., [Werkhoven, P., Sperling, G. & Chubb, C. (1993) Vision Res. 33, 463-485.], the observers fell into two distinct groups based on the direction of perceived motion. The differences were interpreted in terms of the algorithms used to extract motion: one group by using a second-order motion process and the other by using a third-order motion process. This was investigated further using a dual-task paradigm in which the interference between two tasks indicated the nature of processing involved. Observers who used third-order motion processing experienced interference with letter recognition and a more severe interference in dual third-order motion tasks. Observers who used second-order motion processing experienced interference with another second-order motion detection but not with letter recognition. Insofar as task interference implies the need for attention, the complex interference effects and the apparently paradoxical interference effects of second-order motion perception imply that there are multiple forms of attention. Whether two tasks interfere depends on whether they require the same form of attention. Insofar as spatio-temporal processing is assumed to be carried out in the dorsal stream and pattern recognition in the ventral stream, the interference patterns suggest that second-order motion may be computed entirely in the dorsal stream, and third-order motion may involve two computational processes, one of which shares computational resources with the letter recognition task in the ventral stream.

Attention↗

The design and implementation of a motion correction scheme for neurological PET.

A method is described to monitor the motion of the head during neurological positron emission tomography (PET) acquisitions and to correct the data post acquisition for the recorded motion prior to image reconstruction. The technique uses an optical tracking system, Polaris, to accurately monitor the position of the head during the PET acquisition. The PET data are acquired in list mode where the events are written directly to disk during acquisition. The motion tracking information is aligned to the PET data using a sequence of pseudo-random numbers, which are inserted into the time tags in the list mode event stream through the gating input interface on the tomograph. The position of the head is monitored during the transmission acquisition, and it is assumed that there is minimal head motion during this measurement. Each event, prompt and delayed, in the list mode event stream is corrected for motion and transformed into the transmission space. For a given line of response, normalization, including corrections for detector efficiency, geometry and crystal interference and dead time are applied prior to motion correction and rebinning in the sinogram. A series of phantom experiments were performed to confirm the accuracy of the method: (a) a point source located in three discrete axial positions in the tomograph field of view, 0 mm, 10 mm and 20 mm from a reference point, (b) a multi-line source phantom rotated in both discrete and gradual rotations through +/- 5 degrees and +/- 15 degrees, including a vertical and horizontal movement in the plane. For both phantom experiments images were reconstructed for both the fixed and motion corrected data. Measurements for resolution, full width at half maximum (FWHM) and full width at tenth maximum (FWTM), were calculated from these images and a comparison made between the fixedand motion corrected datasets. From the point source measurements, the FWHM at each axial position was 7.1 mm in the horizontal direction, and increasing from 4.7 mm at the 0 mm position, to 4.8 mm, 20 mm offset, in the vertical direction. The results from the multi-line source phantom with +/- 5 degrees rotations showed a maximum degradation in FWHM, when compared with the stationary phantom, of 0.6 mm, in the horizontal direction, and 0.3 mm in the vertical direction. The corresponding values for the larger rotation, +/- 15 degrees, were 0.7 mm and 1.1 mm, respectively. The performance of the method was confirmed with a Hoffman brain phantom moved continuously, and a clinical acquisition using [11C]raclopride (normal volunteer). A visual comparison of both the motion and non-motion corrected images of the Hoffman brain phantom clearly demonstrated the efficacy of the method. A sample time-activity curve extracted from the clinical study showed irregularities prior to motion correction, which were removed after correction. A method has been developed to accurately monitor the motion of the head during a neurological PET acquisition, and correct for this motion prior to image reconstruction. The method has been demonstrated to be accurate and does not add significantly to either the acquisition or the subsequent data processing.

Algorithms↗

Residual motion of lung tumours in gated radiotherapy with external respiratory surrogates.

Due to respiration, many tumours in the thorax and abdomen may move as much as 3 cm peak-to-peak during radiation treatment. To mitigate motion-induced irradiation of normal lung tissue, clinics have employed external markers to gate the treatment beam. This technique assumes that the correlation between the external surface and the internal tumour position remains constant inter-fractionally and intra-fractionally. In this work, a study has been performed to assess the validity of this correlation assumption for external surface based gated radiotherapy, by measuring the residual tumour motion within a gating window. Eight lung patients with implanted fiducial markers were studied at the NTT Hospital in Sapporo, Japan. Synchronized internal marker positions and external abdominal surface positions were measured during the entire course of treatment. Stereoscopic imaging was used to find the internal markers in four dimensions. The data were used retrospectively to assess conventional external surrogate respiratory-gated treatment. Both amplitude- and phase-based gating methods were investigated. For each method, three gating windows were investigated, each giving 40%, 30% and 20% duty cycle, respectively. The residual motion of the internal marker within these six gating windows was calculated. The beam-to-beam variation and day-to-day variation in the residual motion were calculated for both gating modalities. We found that the residual motion (95th percentile) was between 0.7 and 5.8 mm, 0.8 and 6.0 mm, and 0.9 and 6.2 mm for 20%, 30% and 40% duty cycle windows, respectively. Five of the eight patients showed less residual motion with amplitude-based gating than with phase-based gating. Large fluctuations (>300%) were seen in the residual motion between some beams. Overall, the mean beam-to-beam variation was 37% and 42% from the previous treatment beam for amplitude- and phase-based gating, respectively. The day-to-day variation was 29% and 34% from the previous day for amplitude- and phase-based gating, respectively. Although gating reduced the total tumour motion, the residual motion behaved unpredictably. Residual motion during treatment could exceed that which might have been considered in the treatment plan. Treatment margins that account for motion should be individualized and daily imaging should be performed to ensure that the residual motion is not exceeding the planned motion on a given day.

Dose-Response Relationship, Radiation↗

The impact of acquisition protocol on the incidence of patient motion in 99mTc based myocardial perfusion SPECT.

BACKGROUND: Myocardial perfusion single photon emission computed tomography (SPECT) artefacts introduced as a result of patient motion are known to produce artefacts that mimic the appearances of coronary artery disease. The advent of 99mTc based radiopharmaceuticals permits greater flexibility in patient scheduling, but variable physical demands of protocols may be associated with variations in the likelihood of patient motion. METHODS: A prospective cross-sectional study of 177 myocardial perfusion SPECT patients using 99mTc tetrofosmin was used to compare the incidence of visually detectable motion for three protocol variations. The rotating cinematic display and sinograms of the datasets were visually assessed by two experienced technologist observers blinded to the second observer's responses and the clinical outcome. RESULTS: Among the 354 individual studies analysed, 43.8% contained visually detectable motion. 36.2% of rest studies demonstrated visually detectable motion compared to 51.4% for stress (P<0.05). Fifty per cent of 1 day rest/stress studies demonstrated motion, 39.3% of 2 day rest/stress studies demonstrated motion, and 46.8% of 2 day stress/rest studies demonstrated motion. CONCLUSION: One day 99mTc based myocardial perfusion SPECT studies are 1.3 times more likely to contain motion than the 2 day rest/stress protocol. The 2 day stress/rest protocol is 1.2 times more likely to contain motion than the 2 day rest/stress. The stress study is 1.4 times more likely to contain motion than the rest study while the stress study performed first in the sequence is 1.4 times more likely to contain motion than the stress study performed second. The 2 day rest/stress protocol is the preferred protocol to minimize patient motion.

Adult↗

Motion characteristics of the lumbar spine in the normal population.

STUDY DESIGN: The present study investigated the dynamic motion characteristics of the lumbar spine in the normal population using a potentiometric analysis system. OBJECTIVES: To assess the ability of a triaxial potentiometric analysis system to measure dynamic motion in the lumbar spine, and to use this system to form a database of dynamic motion characteristics from which normal parameters of motion and the factors affecting this motion could be defined. SUMMARY OF BACKGROUND DATA: Spinal motion has been studied using a variety of different methods, the majority of which have been limited either in terms of reliability, accuracy, or invasiveness and many have been only of a static nature. There has been no previous study into the normal dynamic motion characteristics of the lumbar spine. METHODS: The accuracy of the system was determined by a series of tests against a calibrated engineering mill, and the reliability of the system was assessed on 10 subjects with repeated measurements over a 3-day period. Values of range of motion and angular velocity were obtained from 203 normal subjects during flexion and extension, lateral flexion, and rotation. RESULTS: The results of the calibration testing revealed excellent accuracy, and it was shown that the system was repeatable. Initial analysis of the results indicated that sex differences did exist with men having 58.4 degrees of flexion and women having 53.4 degrees. Age appeared to have an influence on motion, and a gradual reduction was seen with each decade (P < 0.001), with the 20-29-year age range having 59.5 degrees mean flexion, the 30-39-year group having 58.1 degrees, the 40-49-year group having 53.7 degrees, the 50-60-year group having 57.5 degrees, and the 60-70-year group having 45.9 degrees. Multiple regression techniques revealed that only a few factors are important with respect to motion and that these varied according to the characteristic being defined. CONCLUSIONS: Range of motion tended to be affected by age and sex, whereas velocity was only affected by distance moved, with occupation and body mass index having little or no influence on the motion. The factors identified could only account for a small proportion of the variation seen, suggesting that it is difficult to predict the motion characteristics with any degree of sensitivity.

Adult↗

Dynamic motion study of the whole lumbar spine by videofluoroscopy.

STUDY DESIGN: Dynamic lumbar flexion-extension motion was assessed by videofluoroscopy. OBJECTIVES: To identify the motion patterns of the whole lumbar spine in normal subjects and in patients with low back pain or spondylolisthesis during actual movement. SUMMARY OF BACKGROUND DATA: Assessment of lumbar instability on terminal radiographs is controversial. Information regarding spinal kinematics during actual movement in vivo is scarce. METHODS: Fluoroscopic lumbar sagittal motion videos were recorded in volunteers (n = 13; mean age, 22.3) and in patients with chronic low back pain (n = 8; mean age, 43.5) and degenerative spondylolisthesis (n = 8; mean age, 63.1) while the subjects bent forward from a standing neutral position (eccentric motion) and then returned to the original position (concentric motion). The videos recorded approximately 8 seconds of motion and were converted to still images at 5 frames per second. Disc angles from the horizontal line were measured to estimate sagittal rotation of each segment. Disc degeneration was evaluated on T2-weighted midsagittal magnetic resonance image. RESULTS: In the volunteer group, six exhibited sequentially spreading motion, four exhibited simultaneous motion, and three showed an altered motion-spreading pattern in the eccentric phase. The first two patterns were considered normal. Six (67%) of the patients with chronic low back pain also showed normal patterns, but seven (88%) of the patients with degenerative spondylolisthesis showed disordered patterns. The order of motion in the concentric phase was also different among the three groups. Prolonged deflection of the slipped segment was observed more frequently in the patients with degenerative spondylolisthesis. Disc degeneration was not always associated with motion-spreading order and the motion patterns. CONCLUSION: Segmental instability influences the whole lumbar motion in patients with degenerative spondylolisthesis. The patients with chronic low back pain did not show a significant difference when compared with the volunteers.

Adult↗

Use of percutaneous transpedicular external fixation pins to measure intervertebral motion.

STUDY DESIGN: Direct measurement of intervertebral motion was compared to motion determined by measuring the position of the exposed ends of the external fixation pins. OBJECTIVES: To verify the accuracy of this technique, so that this protocol can be used to study intervertebral motion in the clinical setting. SUMMARY OF BACKGROUND DATA: The transpedicular external fixation test has been shown to be a test that can predict the outcome of spinal fusion. In patients who are candidates for this test, intervertebral motion can be calculated from motion at the external ends of these pins. METHODS: Six fresh cadaveric spinal segments from L2 to L5 were instrumented with titanium Schanz screws. Reflective markers were placed on the tips of the pins, and intervertebral motion was measured using a noncontacting camera system. Computed tomography data were used to determine the position of the vertebra relative to the reflective markers. Intervertebral distances were calculated and compared with direct measurements obtained using a three-dimensional digitizing arm. RESULTS: There was an excellent correlation (r2 = 0.931) between the directly measured intervertebral motions and those that were indirectly calculated from measurements of motion at the end of the Schanz screws. CONCLUSIONS: Intervertebral motion can be measured by monitoring motion of the ends of transpedicular external fixation pins. Motion of anatomic landmarks on the vertebrae can be calculated from the pin end's motion if computed tomography data are used to determine the geometric relation between the vertebrae and the external fixation pins. This validation study supports the use of this method in clinical investigations of intervertebral motion in patients with low back pain and external fixation.

Aged↗

The effect of anterior cervical fusion on neck motion.

STUDY DESIGN: Prospective cohort study. OBJECTIVE: To precisely measure the effect of anterior cervical fusion on neck motion. SUMMARY OF BACKGROUND DATA: Anterior cervical decompression and stabilization procedures are successful in treating recalcitrant cervical radiculopathy and cervical myelopathy. Most assume that these "fusion" procedures result in a loss of neck motion, although changes in overall motion following anterior cervical fusion have never been precisely quantified. METHODS: Twenty-five consecutive patients undergoing anterior cervical fusion of one to four levels underwent cervical range of motion testing in three planes using an unconstrained instrumented linkage before surgery and more than 3 months after surgery. These data were compared with that of 10 volunteers with no prior history of neck complaints. Motion data were compared between patients and volunteers, and between the patients before surgery and at last follow-up, using RMANOVA and Fisher's PLSD post hoc test. RESULTS: Before surgery, the patients had significantly less motion than the volunteers in all directions. Following surgical fusion, patients gained a statistically significant amount of motion in all planes, although they did not achieve the motion seen among the volunteers. Gains in motion were seen among all patients, including those undergoing four-level fusions, and there was no correlation between postoperative motion and the number of levels fused. CONCLUSIONS: Patients undergoing anterior cervical fusion have diminished neck motion compared with normal volunteers. Following surgery, they may be expected to gain motion, even when undergoing multilevel fusions. However, these patients are unlikely to regain the neck motion seen among normal individuals without neck complaints.

Adult↗

The management of respiratory motion in radiation oncology report of AAPM Task Group 76.

This document is the report of a task group of the AAPM and has been prepared primarily to advise medical physicists involved in the external-beam radiation therapy of patients with thoracic, abdominal, and pelvic tumors affected by respiratory motion. This report describes the magnitude of respiratory motion, discusses radiotherapy specific problems caused by respiratory motion, explains techniques that explicitly manage respiratory motion during radiotherapy and gives recommendations in the application of these techniques for patient care, including quality assurance (QA) guidelines for these devices and their use with conformal and intensity modulated radiotherapy. The technologies covered by this report are motion-encompassing methods, respiratory gated techniques, breath-hold techniques, forced shallow-breathing methods, and respiration-synchronized techniques. The main outcome of this report is a clinical process guide for managing respiratory motion. Included in this guide is the recommendation that tumor motion should be measured (when possible) for each patient for whom respiratory motion is a concern. If target motion is greater than 5 mm, a method of respiratory motion management is available, and if the patient can tolerate the procedure, respiratory motion management technology is appropriate. Respiratory motion management is also appropriate when the procedure will increase normal tissue sparing. Respiratory motion management involves further resources, education and the development of and adherence to QA procedures.

Guidelines as Topic↗

Effect of motion contrast on human cortical responses to moving stimuli.

The cortical areas activated by motion-defined contours were studied in humans using positron emission tomography (PET). Subjects observed four types of random dot fields, displayed through a 21 degrees diam aperture: unidirectional motion of a translating dot field, motion in opposing directions of two superimposed translating fields, motion in opposing directions of dots in contiguous spatial regions (motion contrast), producing a square wave grating defined by motion, and luminance variation of stationary dots in contiguous spatial regions, producing a square wave grating defined by luminance. Relative to a static dot field, the unidirectional motion condition activated areas previously described, including areas 17/18, lateral temporal-occipital-parietal cortex (MT/MST), and the superior temporal sulcus. Motion-defined gratings increased the activation of areas 17/18 and MT/MST, but not the superior temporal sulcus, and added more dorsal areas in the cuneus, roughly corresponding to V3/V3a, and ventral areas in the lingual gyrus/collateral sulcus, roughly corresponding to V2/VP. Luminance defined gratings, relative to a static dot field, activated areas 17/18, regions in the dorsal cuneus similar to those activated by motion defined gratings, and a region near the left collateral sulcus, slightly lateral to the motion grating activation. They also activated a region in the right fusiform gyrus that was more weakly activated by the motion grating. These results indicate that adding motion contrast to large moving fields increases activity in areas 17/18 and MT/MST and adds both dorsal and ventral regions that are similar for motion and luminance defined contours.

Adult↗

Sensitivity to simulated directional sound motion in the rat primary auditory cortex.

Sensitivity to simulated directional sound motion in the rat primary auditory cortex. This paper examines neuron responses in rat primary auditory cortex (AI) during sound stimulation of the two ears designed to simulate sound motion in the horizontal plane. The simulated sound motion was synthesized from mathematical equations that generated dynamic changes in interaural phase, intensity, and Doppler shifts at the two ears. The simulated sounds were based on moving sources in the right frontal horizontal quadrant. Stimuli consisted of three circumferential segments between 0 and 30 degrees, 30 and 60 degrees, and 60 and 90 degrees and four radial segments at 0, 30, 60, and 90 degrees. The constant velocity portion of each segment was 0.84 m long. The circumferential segments and center of the radial segments were calculated to simulate a distance of 2 m from the head. Each segment had two trajectories that simulated motion in both directions, and each trajectory was presented at two velocities. Young adult rats were anesthetized, the left primary auditory cortex was exposed, and microelectrode recordings were obtained from sound responsive cells in AI. All testing took place at a tonal frequency that most closely approximated the best frequency of the unit at a level 20 dB above the tuning curve threshold. The results were presented on polar plots that emphasized the two directions of simulated motion for each segment rather than the location of sound in space. The trajectory exhibiting a "maximum motion response" could be identified from these plots. "Neuron discharge profiles" within these trajectories were used to demonstrate neuron activity for the two motion directions. Cells were identified that clearly responded to simulated uni- or multidirectional sound motion (39%), that were sensitive to sound location only (19%), or that were sound driven but insensitive to our location or sound motion stimuli (42%). The results demonstrated the capacity of neurons in rat auditory cortex to selectively process dynamic stimulus conditions representing simulated motion on the horizontal plane. Our data further show that some cells were responsive to location along the horizontal plane but not sensitive to motion. Cells sensitive to motion, however, also responded best to the moving sound at a particular location within the trajectory. It would seem that the mechanisms underlying sensitivity to sound location as well as direction of motion converge on the same cell.

Acoustic Stimulation↗

Spatial receptive fields of inferior colliculus neurons to auditory apparent motion in free field.

We examined responses from 91 single-neurons in the inferior colliculus (IC) of anesthetized guinea pigs to auditory apparent motion in the free field. Apparent motion was generated by presenting 100-ms tone bursts, separated by 50-ms silent intervals, at consecutive speaker positions in an array of 11 speakers, positioned in an arc +/-112.5 degrees around midline. Most neurons demonstrated discrete spatial receptive fields (SRFs) to apparent motion in the clockwise and anti-clockwise directions. However, SRFs showed marked differences for apparent motion in opposite directions. In virtually all neurons, mean best azimuthal positions for SRFs to opposite directions occurred at earlier positions in the motion sweep, producing receptive fields to the two directions of motion that only partially overlapped. Despite this, overall spike counts to the two directions were similar for equivalent angular velocities. Responses of 28 neurons were recorded to stimuli with different duration silent intervals between speaker presentations, mimicking different apparent angular velocities. Increasing the stimulus OFF time increased neuronal discharge rates, particularly at later portions of the apparent motion sweep, and reduced the differences in the SRFs to opposite motion directions. Consequently SRFs to both directions broadened and converged with decreasing motion velocity. This expansion was most obvious on the outgoing side of the each SRF. Responses of 11 neurons were recorded to short (90 degrees ) partially overlapping apparent motion sweeps centered at different spatial positions. Nonoverlapping response profiles were recorded in 9 of the 11 neurons tested and confirmed that responses at each speaker position were dependent on the preceding response history. Together these data are consistent with the suggestion that a mechanism of adaptation of excitation contributes to the apparent sensitivity of IC neurons to auditory motion cues. In addition, the data indicate that the sequential activation of an array of speakers to produce apparent auditory motion may not be an optimal stimulus paradigm to separate the temporal and spatial aspects of auditory motion processing.

Acoustic Stimulation↗

Contrast gain control in first- and second-order motion perception.

A novel pedestal-plus-test paradigm is used to determine the nonlinear gain-control properties of the first-order (luminance) and the second-order (texture-contrast) motion systems, that is, how these systems' responses to motion stimuli are reduced by pedestals and other masking stimuli. Motion-direction thresholds were measured for test stimuli consisting of drifting luminance and texture-contrast-modulation stimuli superimposed on pedestals of various amplitudes. (A pedestal is a static sine-wave grating of the same type and same spatial frequency as the moving test grating.) It was found that first-order motion-direction thresholds are unaffected by small pedestals, but at pedestal contrasts above 1-2% (5-10 x pedestal threshold), motion thresholds increase proportionally to pedestal amplitude (a Weber law). For first-order stimuli, pedestal masking is specific to the spatial frequency of the test. On the other hand, motion-direction thresholds for texture-contrast stimuli are independent of pedestal amplitude (no gain control whatever) throughout the accessible pedestal amplitude range (from 0 to 40%). However, when baseline carrier contrast increases (with constant pedestal modulation amplitude), motion thresholds increase, showing that gain control in second-order motion is determined not by the modulator (as in first-order motion) but by the carrier. Note that baseline contrast of the carrier is inherently independent of spatial frequency of the modulator. The drastically different gain-control properties of the two motion systems and prior observations of motion masking and motion saturation are all encompassed in a functional theory. The stimulus inputs to both first- and second-order motion process are normalized by feedforward, shunting gain control. The different properties arise because the modulator is used to control the first-order gain and the carrier is used to control the second-order gain.

Contrast Sensitivity↗

Anisotropies in visual motion perception: a fresh look.

We measured motion-detection and motion-discrimination performance for different directions of motion, using stochastic motion sequences. Random-dot cinematograms containing 200 dots in a circular aperture were used as stimuli in a two-interval forced-choice procedure. In the motion-detection experiment, observers judged which of two intervals contained weak coherent motion, the other internal containing random motion only. In the direction-discrimination experiment, observers viewed a standard direction of motion followed by comparison motion in a slightly different direction. Observers indicated whether the comparison was clockwise or counterclockwise, relative to the standard. Twelve directions of motion were tested in the detection task and five standard directions (three cardinal directions and two oblique directions) in the discrimination task. Detection thresholds were invariant with direction of motion, but direction-discrimination thresholds were significantly higher for motion in oblique directions, even at low-coherence levels. Results from control conditions ruled out monitor artifacts and indicate that the oblique effect is relative to retinal coordinates. These results have broad implications for computational and physiological models of motion perception.

Anisotropy↗

Motion artifact seen on slot-scanning direct digital mammography.

OBJECTIVE: Our goal was to determine the appearance of motion artifact when imaging an anthropomorphic breast phantom using a digital slot-scanning system compared with a screen-film system. MATERIALS AND METHODS: Digital and screen-film images were obtained during both brief and continuous manually induced motion of an anthropomorphic phantom in four directions. Continuous motion was further characterized using a syringe pump to induce motion artifact. RESULTS: On screen-film images, brief motion caused degradation of the entire image, simulating a double exposure. Conversely, on digital images using a slot-scanning system, brief motion caused degradation of only a small portion of the image. Continuous motion resulted in smearing of phantom details with both systems, although the smearing was more strongly influenced by the direction of motion when the slot-scanning system was used. With the slot-scanning system, motion in the direction of the detector sweep resulted in elongated distortion, whereas motion in the opposite direction resulted in foreshortening; diagonal smearing was seen with perpendicular phantom motion. The magnitude of distortion for continuous motion at a set velocity was substantially less with the slot-scanning system. CONCLUSION: Motion artifact with a slot-scanning direct digital mammography unit differs significantly from that seen with a conventional screen-film unit and, despite a relatively long overall exposure, may prove to be less of a problem than with conventional units because any given part of an object is exposed only briefly.

Artifacts↗

Segmental cervical spine motion during orotracheal intubation of the intact and injured spine with and without external stabilization.

OBJECT: The purpose of this study was to establish a cadaveric model for evaluating cervical spine motion in both the intact and injured states and to examine the efficacy of commonly used stabilization techniques in limiting that motion. METHODS: Intubation was performed in fresh human cadavers with intact cervical spines, following the creation of a C4-5 posterior ligamentous injury. Movement of the cervical spine during direct laryngoscopy and intubation was recorded using video fluoroscopy and examined under the following conditions: 1) without external stabilization; 2) with manual in-line cervical immobilization; and 3) with Gardner-Wells traction. Subsequently, segmental motion of the occiput through C-5 (Oc-C5) was measured from digitized frames of the recorded video fluoroscopy. The predominant motion, at all levels measured in the intact spine, was extension. The greatest degree of motion occurred at the atlantooccipital (Oc-C1) junction, followed by the C1-2 junction, with progressively less motion at each more caudal level. After posterior destabilization was induced, the predominant direction of motion at C4-5 changed from extension to flexion, but the degree of motion remained among the least of all levels measured. Traction limited but did not prevent motion at the Oc-C1 junction, but neither traction nor immobilization limited motion at the destabilized C4-5 level. CONCLUSIONS: Cadaveric cervical spine motion accurately reflected previously reported motion in living, anesthetized patients. Traction was the most effective method of reducing motion at the occipitocervical junction, but none of the interventions significantly reduced movement at the subaxial site of injury. These findings should be considered when treating injured patients requiring orotracheal intubation.

Aged↗

Cognitive representation of linear motion: possible direction and gravity effects in judged displacement.

The judged vanishing point of a target undergoing apparent motion in a horizontal, vertical, or oblique direction was examined. In Experiment 1, subjects indicated the vanishing point by positioning a crosshair. Judged vanishing point was displaced forward in the direction of motion, with the magnitude of displacement being largest for horizontal motion, intermediate for oblique motion, and smallest for vertical motion. In addition, the magnitude of displacement increased with faster apparent velocities. In Experiment 2, subjects judged whether a stationary probe presented after the moving target vanished was at the same location where the moving target vanished. Probes were located along the axis of motion, and probes located beyond the vanishing point evidenced a higher probability of a same response than did probes behind the vanishing point. In Experiment 3, subjects judged whether a stationary probe presented after the moving target vanished was located on a straight-line extension of the path of motion of the moving target. Probes below the path of motion evidenced a higher probability of a same response than did probes above the path of motion for horizontal and ascending oblique motion; probes above the path of motion evidenced a higher probability for a same response than did probes below the path of motion for descending oblique motion. Overall, the pattern of results suggests that the magnitude of displacement increases as proximity to a horizontal axis increases, and that in some conditions there may be a component analogous to a gravitational influence incorporated into the mental representation.

Adult↗

[Animal model of motion sickness in rats].

Complex accelerative stimuli can induce pica in rats as well as the treatment with poisons, which means eating of non-nutritive substances such as kaolin, in proportion to the severity of their sickness. For the purpose of using pica as an index of motion sickness in rats, we examined what kind of rotation was effective for inducing pica in rats with or without normal bilateral labyrinth functions. Clinically potent anti-motion sickness drugs, such as scopolamine, methamphetamine, diphenhydramine, were examined in reducing rotation-induced pica in rats. Rats ate more kaolin after double rotation with continuously changing acceleration, than after single rotation. Both the animals treated with anti-motion sickness drugs or labyrinthectomy ate less kaolin even after double rotation. Since the physiological and pharmacological mechanisms for inducing pica in rats were similar with those of motion sickness in humans, pica in rats should be an acceptable index of their motion sickness. In order to study neural mechanisms of motion sickness in rats, we examined the effects of an anti-cholinergic as a potent anti-motion sickness drug and cholinergics as an antagonistic drug treated during the 4th-7th day of rotation on both habituation to double rotation within daily rotations for 10-11 days, using pica as an index of motion sickness. Rats were separated into three groups according to their initial susceptibility, and rats with low susceptibility were omitted in these experiments. Scopolamine (TTS-scopolamine) as an anticholinergic facilitated habituation to motion, especially in rats with moderate susceptibility. Treatment of physostigmine suppressed residual habituation to motion sickness in rats, especially with moderate susceptibility, though neostigmine, peripherally acting anti-cholinesterase, had no effect. These results suggested that centrally acting acetylcholine play an important role in suppressing habituation of motion sickness. In conclusion, rats should be a convenient model for studying for motion sickness, as we examined one of the neural mechanisms in motion sickness using pica as an index.

Animals↗