Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “GLOVES”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36Linked to original sources

Test of the Fishbein and Ajzen models as predictors of health care workers' glove use.

The aim of this study was to identify predictors of health care workers' glove use when there is a potential for blood exposure. The study hypothesis was that an extension of the theory of planned behavior would explain more of the variance in glove use behavior than the theory of reasoned action or theory of planned behavior. A random sample of nurses and laboratory workers (N = 527) completed a 26-item questionnaire with acceptable content validity and reliability estimates. Using structural equation modeling techniques, intention, attitude, and perceived risk were significant predictors of behavior. Perceived control and attitude were the significant determinants of intention. The theory of reasoned action was the most parsimonious model, explaining 70% of the variance in glove use behavior. The theory of planned behavior extension was a viable model to study behavior related to glove use and reducing workers' risks to bloodborne diseases.

Adult↗

Effect of laundering on ability of glove fabrics to decrease the penetration of organophosphate insecticides through in vitro epidermal systems.

Two knit glove fabrics, one of 100% cotton and one of 100% polypropylene, were examined for their capability to decrease the penetration of the organophosphate insecticides (OPs), azinphos-methyl and paraoxon after 4 h at field concentrations (3000 and 15 ppm, respectively) through an in vitro epidermal system (Skin2, Advanced Tissue Systems, LaJolla, CA). The glove fabrics were examined under three different conditions of use: new, after they had been abraded and after they had been abraded and then laundered. New and laundered cotton fabric was also examined for its capability to decrease the penetration of azinphos-methyl through another in vitro epidermal system (Epiderm, MatTek Corp., Ashland, MA), after 4 and 24 h of exposure. Capability of the media under the in vitro epidermal systems to inhibit brain acetylcholinesterase (AChE) was used as the indicator of penetration. Results were compared to OP-caused inhibitions seen in media under the fabric alone and in media under the in vitro epidermal systems alone. Incubations of azinphos-methyl suspensions and the in vitro epidermal systems covered with fabric indicated that both the epidermal cells and fabric provided protection against AChE inhibition caused by this OP and that the protective effects were additive, whether measured after 4 or 24 h of exposure. Therefore, neither laundering nor abrasion followed by laundering altered the capability of the in vitro epidermal systems to absorb azinphos-methyl suspension. For paraoxon solution, however, new cotton glove fabric prevented absorption, and this protective effect, noted after 4 h of exposure, was lost when the fabric was laundered. Abrading the fabric did not cause a greater effect than laundering alone. These results suggest that the pesticide as well as its formulation may be factors of consideration when protective fabrics are chosen, and that, for cotton glove fabric, the protection against some OPs may best be provided before the fabric is laundered.

Absorption↗

Surgical gloves as a mechanical barrier against human immunodeficiency viruses.

A wide variety of surgical gloves are presently available. Seven different types of gloves were investigated for the ability to prevent transmission of the human immunodeficiency virus (HIV), the causative agent of AIDS. Six types of gloves withstood severe compression tests and also exhibited direct antiviral properties. No penetration of HIV through the intact glove was detected.

Acquired Immunodeficiency Syndrome↗

Randomized trial of blunt-tipped versus cutting needles to reduce glove puncture during mass closure of the abdomen.

Eighty-five consecutive patients were randomized to undergo mass closure of the abdomen with no. 1 polydioxanone mounted on either a blunt-tipped (n = 46) or cutting (n = 39) needle. Gloves were changed before closure and tested for perforation afterwards using standard air or water techniques. Fourteen pairs of gloves were punctured when using a cutting needle, and three pairs when a blunt-tipped needle was used. The majority of punctures were to the non-dominant glove. The surgeon was aware of the puncture in eight of the 14 instances involving a sharp needle and in one of the three involving a blunt-tipped needle. Blunt-tipped needles, while not eliminating the risk, significantly reduced the incidence of surgical glove puncture (P < 0.001, Fisher's exact test). The use of cutting needles for abdominal closure should be abandoned.

Abdomen↗

In vitro evaluation of the efficacy of skin barrier creams and protective gloves on percutaneous absorption of industrial solvents.

OBJECTIVES: The aim of the experiments was to evaluate the efficacy of skin barrier creams (SBCs) and protective gloves and its potential for reduction of percutaneous absorption of industrial solvents. METHODS: We assessed percutaneous absorption of ethylene glycol (EG), isopropyl alcohol (IA) and 1,2,4-trimethylbenzene (TMB), using static diffusion cells. These solvents were applied neat (EG, TMB) as well as in 10% and 50% aqueous solution (EG, IA) or in 10% and 50% ethanol-diluted solution (TMB). Furthermore, we tested the percutaneous absorption of IA mixed in one cleaning agent (CA), used in newspaper printing shops to clean the rollers of printing machines. Additionally, the penetration behaviour of 10% and 50% solutions of EG, IA and TMB was tested. The experiments were carried out on untreated and on SBC-treated excised human skin from one donor, and on protective gloves. Saline was used as receptor fluid for EG and IA, and neat ethanol for TMB. RESULTS: The penetration of 50% EG, IA and TMB solutions through SBC-treated skin was higher than in untreated skin (factor 3.9 for EG, 0.32 for IA and 0.06 for TMB). The penetration of IA in the IA-CA mixture was five-times higher through untreated skin as for the single compound in 10% aqueous solution. In skin, treated with SBC, we found a 17-fold penetration enhancement of IA in the IA-CA mixture. No appreciable penetration of EG and IA was observed through nitrile rubber gloves. CONCLUSIONS: Our in vitro experiments could not demonstrate an efficacy of SBC to protect skin penetration for the tested solvents. The percutaneous absorption of all solvents in 50% solution was increased through skin treated with SBCs. Furthermore, SBCs enhance the penetration rates of solvents from complex mixtures compared with the single solvents. The tested gloves showed sufficient protection for the hydrophilic solvents, but not for TMB.

2-Propanol↗

Is the use of boxed gloves in an intensive care unit safe?

PURPOSE: To identify the type, rate, burden, and pattern of contamination of boxed, clean but nonsterile gloves in our intensive care unit (ICU). MATERIALS AND METHODS: The fingertips of the first, middle, and last two pairs of gloves in 29 boxes in routine service in our ICU were cultured. The first of each of these three sets were removed aseptically, the second in a routine fashion. RESULTS: We found 16 of 29 (55%) first pairs removed aseptically to be contaminated with a mean bioburden of 1.8 colony-forming units (CFU). The percentage contamination and bioburden did not change significantly with position in the box. Use of routine compared with strict aseptic technique increased the rate of contamination by only 11% (95% confidence interval [CI] -0.05 to +0.27 percentage points) and bioburden by only a mean of 3.4 colonies per pair (CI -0.51 to +4.90 CFU). The length of the time the boxes were open and in use was unrelated to whether the final aseptically removed pair was sterile or contaminated. The predominant organisms were coagulase-negative staphylococci. CONCLUSIONS: One half the pairs of latex examination gloves in our ICU were sterile despite repeated barehanded access to the boxes. Those contaminated exhibited a small bioburden of low pathogenic potential. No pattern of contamination or unsafe duration of box use were observed. The use of boxed, clean, nonsterile gloves appears safe for routine use in an ICU.

Bacterial Infections↗

The cytotoxic effect of surgical glove powder particles on adult human vascular endothelial cell cultures: implications for clinical uses of tissue culture techniques.

Clinical use of autogenous endothelial cell (EC) seeding of vascular prostheses (VP) would require reliable methods for EC harvest for immediate seeding or primary culture in a hospital or operating room setting. Observation of glove powder particles (GPP) in failed primary adult human saphenous vein EC (AHSVEC) cultures led us to study the effect of surgical GPP on cultured AHSVEC. Addition of GPP to the culture medium of growing ASHVEC cultures reduced the cell counts in a dose-dependent fashion; the mean concentration of GPP required to produce a greater than 50% decrease in cell number was 1.5 +/- 0.8 (SD) X 10(4) GPP/ml (N = 10 experiments), equivalent to a mean dose of 36 micrograms glove powder per milliliter. The effect was seen within 24 hr of addition of GPP and was not due to interference with EC attachment and spreading or to changes in medium osmolality, pH, glucose, electrolyte, Ca2+, or Mg2+ content. Instead, the effect appeared to be due to a filterable toxin added during the final rubber-vulcanizing stage of glove manufacture, since pure cornstarch particles and epichlorhydrin-treated pure cornstarch did not prevent culture growth, whereas 0.2 micron filtrates of medium incubated with GPP taken directly from gloves were lethal. We conclude that filterable cytotoxic substances from GPP may be an avoidable cause of failure in EC seeding of VP, and may affect surgical wound healing as well.

Cell Adhesion↗

Electric pulp testing with examination gloves.

The electric pulp test (EPT) is a valuable diagnostic aid in assessing the vitality of the dental pulp; however, its use with the operator wearing examination gloves is controversial. In this study, 15 female and 15 male subjects had two different clinically sound teeth tested with an Analytic Technology digital electric pulp tester, both with and without latex examination gloves being worn by the operator. Statistically significant differences between EPT results for the same teeth with the operator's hands being gloved and ungloved were noted. However, the mean differences in EPT results were small and were thought to be diagnostically insignificant for clinical situations. As long as the patient "completes the circuit" by also holding the metallic handle of the electric pulp tester's probe, dentists can easily, reliably, and accurately use the EPT while wearing examination gloves.

Adult↗

Contact dermatoses from disposable glove use: a review.

Contact dermatoses from disposable gloves are being reported with greater frequency. A variety of eruptions can occur. These have become increasingly relevant for dermatologists, who for most procedures now use disposable gloves. This article represents a review of the relevant issues about the use of disposable gloves by dermatologists. Methods of management and prevention of morbidity associated with disposable glove use will also be discussed.

Dermatitis, Contact↗

The effect of handling procedures on microbial contamination of enteral feeds--a comparison of the use of sterile vs non-sterile gloves.

The use of non-sterile disposable gloves to reduce the level of microbial contamination introduced into enteral feeds during the assembly of the feeding systems was investigated. No contamination was detected in any of the feed samples collected from the systems assembled wearing non-sterile gloves. The number of microorganisms transferred to the surface of agar plates used for fingerprint cultures was reduced from an average of 43-54 colony forming units (cfu) per plate for volunteers with bare hands to less than 1 cfu when they wore non-sterile gloves. No contamination was detected on plates touched by volunteers wearing sterile gloves.

Adolescent↗

Use of non-sterile gloves in clinical practice.

This paper reviews the use of non-sterile gloves in dental practice. It is now considered to be normal practice to wear gloves for all dental procedures and although there is considerable controversy regarding patterns of glove use, there is increasing evidence to the effect that single patient use is indicated. Careful use of gloves and proper hand care are key components to effective cross-infection control in clinical practice.

Attitude of Health Personnel↗

Considerations in the selection of surgical gloves for tape wound closure.

One of the reasons that tape closure of wounds is rarely used in the emergency department is that it is difficult for the emergency physician wearing powdered, latex gloves to handle skin closure tapes. Because the skin closure tapes adhere aggressively to powdered latex gloves, it is difficult for the emergency physician to separate the tape from his glove and apply the tape to the skin. The advent of a new powder free glove allows the emergency physician to handle the tapes and accomplish tape wound closure.

Adhesiveness↗

Bacterial contamination of nonsterile disposable gloves before use.

BACKGROUND: After Bacillus cereus recovery in opened boxes of disposable gloves, the bacteriological contamination of disposable nonsterile gloves kept stored in native packages was investigated prospectively. METHODS: Thirty-six commercially available nonsterile nonpowdered disposable gloves made of latex, vinyl, or nitrile were cultured. RESULTS: A large variety of spore-forming and non-spore-forming bacteria was recovered, including Bacillus cereus and Clostridium perfringens. CONCLUSION: This finding must be taken into consideration for care involving gloves in very immunocompromised patients.

Bacillus cereus↗

Effects of surgical gloves on postoperative peritoneal adhesions and cytokine expression in a rat model.

BACKGROUND: Postoperative intraperitoneal adhesions are a major cause of morbidity. We studied the effects of synthetic and latex gloves, and their powders, on postoperative adhesions and cytokine expression in a rat model. METHODS: Rats underwent laparotomy and cecal abrasion. Rats were grouped based on the glove type used: synthetic powder-free (SPF), synthetic powdered (SP), latex powder-free (LPF), and latex powdered (LP). Serum cytokine (tumor necrosis factor [TNF], interleukin-1 [IL-1], and IL-6) levels were measured. Animals were killed and peritoneal adhesions were graded. RESULTS: The SPF group had no adhesions. Adhesions were increased similarly in the SP and LPF groups, and further increased in the LP group. Postoperative serum cytokine levels showed a similar pattern of increases. CONCLUSIONS: The presence of latex or powder on surgical gloves promoted increased adhesions. Serum cytokine levels correlated with the degree of adhesion formation. Strategies to use latex-free, powder-free gloves and/or limit cytokine expression may decrease peritoneal adhesions in the clinical setting.

Analysis of Variance↗

Efficacy of three surface disinfectants for dental radiographic films and gloves.

Contaminated radiographic films and gloves may transmit infectious diseases. Objective. To determine whether Pre Sept (NaDC), a sodium dichloroisocyanurate based disinfectant; Bronocide SP (AIP) an alcohol-phenol-iodine disinfectant and polyvinyl pyrrolidine iodine (PVPI) can be used to disinfect radiographic films and gloves. Study design. Radiographic films were contaminated with Candida albicans, Streptococcus mutans, Lactobacilli or saliva and placed in either 0.1, 0.25 or 0.5 NaDC for 1, 2 or 5 min; PVPI for 5 min or sprayed with AIP. Gloves contaminated with C. albicans, S. mutans or Lactobacilli were sprayed with AIP. After treatment the films and gloves were tested for viable microorganisms. Results. A 0.5% solution of NaDC killed all microorganisms after one-minute exposure. PVPI killed 99.8% and AIP spray between 95.8 and 99% of microorganisms. Conclusions. NaDC was the most successful disinfectant in the laboratory and clinical setting followed by PVPI and AIP.

Benzyl Alcohols↗

Using gloves coated with a dermal therapy formula to improve skin condition.

Thirty-one health care workers, of whom 24 (77%) were perioperative nurses, evaluated a new nonlatex surgical glove with a coating consisting of ingredients clinically proven to have beneficial effects on skin health. In this one-day, clinical self-assessment study, nurses and other health care workers compared the condition of the skin on their hands before and after wearing these surgical gloves. Eighty-one percent of the perioperative nurses and health care workers rated the skin on the hand that had worn the glove as less dry than it had been at baseline. Sixty-five percent rated their skin as more hydrated, and 58% rated their skin as smoother and more supple after wearing a surgical glove coated with a dermal therapy formulation.

Adult↗

The risks and challenges of surgical glove failure.

The relationship between infection control standards and surgical gloving practices is an important issue in combating infectious disease. For their own and their patients' protection, health care personnel must rely on the barrier qualities of gloves more than ever before. Both surgical and examination gloves fail frequently, which puts health care providers and patients at risk of acquiring fluid-borne pathogens. This paper discusses current guidelines, the risk of infection by viral and bacterial pathogens, controversial issues involving gloving practices, and recommendations to improve infection control practices.

Adult↗

Influence of blunt needles on surgical glove perforation and safety for the surgeon.

BACKGROUND: Round-tipped blunt needle (BN) may decrease the risk of needlestick injuries and hand contamination. We prospectively determined the incidence of glove perforations in emergency abdominal procedures and the efficacy of BN in increasing the safety for surgeons. METHODS: Two hundred patients were randomized to undergo closure of the abdominal fascia using sharp needle (SN) or BN. Gloves were tested at the end of the procedure. RESULTS: Surgeons had 14 needlestick injuries and 76 perforations recorded in 69 pair of gloves. Sharp needles were responsible for all injuries and 58 (76%) perforations (P < 0.00004 and P < 0.00001, respectively). This difference was still higher when considering the perforations related to the abdominal fascia closure (BN 7% versus SN 50%; P < 0.0006). CONCLUSION: The risk of glove perforation is sevenfold greater if SN are used. Blunt needles reduce sharp injuries and improve safety for surgeons.

Accidents, Occupational↗