Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Fixatives”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36Linked to original sources

Mechanical property analysis of small bone fixators.

The purpose of this study is to establish a database and to compare mechanical properties between various types of small bone fixators. Hollow maple dowels are uniformly produced to simulate small bones in this study. Furthermore, transverse osteotomy, transverse osteotomy with 2 mm gap, and 45 degrees oblique osteotomies are created to simulate stable, unstable, and spiral fractures. Each fracture pattern is then approximated with four types of fixators: (1) Aesculap mini external fixator, (2) mini A-O plate and screw, (3) cross pin, and (4) self-assembled mini external fixator. Finally, tension, torsion, and bending tests are performed with INSTRON. In three different fracture patterns, dorsal plating has the strongest tensile rigidity and lateral bending rigidity. In stable and unstable fractures, Aesculap mini external fixator has the strongest torsional rigidity. However, mini A-O plate has the strongest torsional rigidity in 45 degrees oblique fractures. In stable fractures, dorsal plating, lateral plating, and mini external fixator all have good anterior bending rigidity without significant differences. Nevertheless, only lateral plating and mini external fixator show good anterior bending rigidity in unstable and 45 degrees oblique fractures. Except in torsional rigidity, Aesculap mini external fixator is not significantly stiffer than the self-assembled external fixator. As expected, cross pin is the weakest fixator. Differences in mechanical stiffiness between the four types of small bone fixators are provided in this study. Additionally, one should also consider the indication when choosing a proper fixator. Complication rate can then be lowered to achieve successful surgery in treating small bone fractures.

Bone Substitutes↗

Reliability of fixation preference testing in diagnosing amblyopia.

We evaluated the sensitivity and specificity of standard fixation preference testing and the 10-prism diopter (PD) fixation test in 427 patients. Standard fixation preference testing showed good sensitivity and specificity for than 10 PD. Patients with small angle tropias, however, had a high false-positive rate, with 40% of nonamblyopic patients inappropriately responding with strong fixation preference. The 10-PD fixation test reduced this high false-positive rate and showed only 1.5% false-positive results. Unfortunately, this shift to equal fixation preference was also seen in some patients with amblyopia, as five of 19 patients with three or more lines difference alternated fixation with the 10-PD fixation test. Retesting disclosed that, although these children would briefly alternate to the amblyopic eye while viewing a stationary target, they would not hold fixation with the amblyopic eye through smooth pursuit. Our conclusion is that standard fixation preference testing can be used to diagnose moderate to severe amblyopia in patients with tropias greater than 10 PD. Patients with small angle deviations or straight eyes should be examined with the 10-PD fixation test, with the criterion for equal vision being the ability to hold fixation well with either eye through smooth pursuit.

Amblyopia↗

Calibration and standardization of microwave ovens for fixation of brain and peripheral nerve tissue.

Rapid and reproducible fixation of brain and peripheral nerve tissue for light and electron microscopy studies can be done in a microwave oven. In this review we report a standardized nomenclature for diverse fixation techniques that use microwave heating: (1) microwave stabilization, (2) fast and ultrafast primary microwave-chemical fixation, (3) microwave irradiation followed by chemical fixation, (4) primary chemical fixation followed by microwave irradiation, and (5) microwave fixation used in various combinations with freeze fixation. All of these methods are well suited to fix brain tissue for light microscopy. Fast primary microwave-chemical fixation is best for immunoelectron microscopy studies. We also review how the physical characteristics of the microwave frequency and the dimensions of microwave oven cavities can compromise microwave fixation results. A microwave oven can be calibrated for fixation when the following parameters are standardized: irradiation time; water load volume, initial temperature, and placement within the oven; fixative composition, volume, and initial temperature; and specimen container shape and placement within the oven. Using two recently developed calibration tools, the neon bulb array and the agar-saline-Giemsa tissue phantom, we report a simple calibration protocol that identifies regions within a microwave oven for uniform microwave fixation.

Animals↗

[Photodynamic therapy of subfoveal choroid neovascularization. Analysis of fixation behavior].

BACKGROUND: In a prospective, randomized, placebo-controlled clinical trial, we have analyzed the pattern of fixation in patients with subfoveal choroidal neovascularization in age-related maculopathy, who have been treated with photodynamic therapy (Verteporfin). MATERIALS AND METHODS: The patients in this study were participating in the TAP trial at a study center (Lübeck). The TAP study inclusion criteria have been applied and photodynamic therapy was carried out by the TAP study standard protocol. For microperimetric analysis we used the Scanning Laser Ophthalmoscope 101 (Rodenstock). Fixation was classified into foveal and excentric fixation. In addition we quantified the area of fixation (mm2). All patients had a follow-up of 2 years. RESULTS: Out of 33 patients in the Verteporfin group, 29 showed central fixation at baseline and only 11 out of 33 had foveal fixation after 24 months. The area of fixation in this group was measured at baseline at 0.44 mm2, at 1.76 mm2 after 6 months and at 2.4 mm2 after 12, 18 and 24 months, respectively. In the placebo group 11 out of 13 patients had foveal fixation at baseline and after 24 months 2 out of 13 demonstrated central fixation. The area of fixation increased from 0.76 mm2 at baseline up to 2.4 mm2 after 6 months, to 4.9 mm2 after 12 months, to 7.1 mm2 after 18 months and finally after 24 months up to 9.61 mm2. CONCLUSIONS: Photodynamic therapy with Verteporfin does not prevent loss of central fixation in patients with subfoveal choroidal neovascularization in age-related maculopathy, however PDT has a significant stabilizing effect on the development of the area of fixation.

Aged↗

[Fixation behavior in Stargardt disease. Fundus-controlled studies].

UNLABELLED: Patients with Stargardt's disease often show a significantly reduced ability to read despite fairly good visual acuity. We evaluated whether fundus perimetry with simultaneous observation of the point of fixation can help to explain these difficulties. METHODS: A total of 40 eyes in 21 patients with Stargardt's disease were examined by means of automatic fundus threshold perimetry and special fixation tasks using a scanning laser ophthalmoscope (SLO). RESULTS: During fundus perimetry 19 eyes showed a movement of the mean fixation point towards the top, and five to the right of the central scotoma. At the same time, the variation around the mean fixation point was orientated vertically. We observed an alternation between two different points of fixation in another eight eyes. While one fixation point was usually located in the center inside an area of reduced light sensitivity, the second new locus of fixation was at the top of the scotoma (six of eight eyes). Patients tried to fix small targets inside the scotomatous area. CONCLUSION: Our results demonstrate that patients with Stargardt's disease exhibit a typical pattern of fixation. The development of eccentric fixation occurs in three steps: The initial phase is characterized by central fixation with decreased stability. In the intermediate phase, we observed alternation between central and eccentric fixation. Finally, patients develop a constant eccentric fixation. These results may explain the difficulties in reading which many Stargardt's patients experience and the problems in prescribing corrective devices for these patients.

Adult↗

Suppression of the human vestibulo-ocular reflex by visual fixation or forced convergence in the dark, with a model interpretation.

Six normal humans experienced yaw axis steps of velocity at 120 degrees /s in the dark. During the post-rotary period, subjects either had a null-task (do nothing); an ocular motor task (forced convergence: crossing the eyes); or a visual task (fixating a head-stationary target against a background of 10 degrees light/dark bars). Tasks started at 3 s post-rotation, and lasted either 2, 5, 10, or 15 s. Ocular motor and visual tasks were tested on different days. Five repetitions of each task duration were recorded for each subject. A mean VOR gain of 0.52 was observed, which did not vary with experimental conditions. Both convergence and fixation markedly suppressed nystagmus; in fact, the VORs obtained with the two different tasks are superficially similar in appearance. However, mean null-task time-constants were 9.4 s for convergence days, but 8.4 s for fixation days, and there was a small but significant reduction in overall null-task VOR amplitude on fixation days. Also, post-convergence slow-phase velocities were slightly enhanced, while post-fixation velocities were significantly reduced. The time-constant of velocity storage was found to be 10.1 s for convergence responses and 8.2 s for fixation responses. These differences can be understood in terms of modifications in central velocity storage during visual fixation which do not occur with convergence. The mean fixation data were analyzed in the context of a VOR model well-established for monkey data. With appropriate choice of parameters, this model accurately reproduces most features of the human data. An estimate for the human cupula time-constant of 3.3 s is obtained. Compared with the monkey, fixation suppression is greater and post-fixation velocity reduction less. Retinal slip alone accounts well for this; "velocity dumping" by an integrator shunt must be slight if present at all. The model correctly represents the post-fixation VOR for all durations of fixation.

Convergence, Ocular↗

An ex vivo mechanical evaluation of single versus double semitubular plate fixation of a transverse distal-third scapular osteotomy in the dog.

OBJECTIVE: To compare single versus double semitubular plate fixation for scapular body fractures. STUDY DESIGN: Ex vivo mechanical study. SAMPLE POPULATION: Eighteen paired cadaveric canine scapulae. METHODS: Transverse scapular body osteotomies were created in the distal third of 18 pairs of scapulae. One scapula of each pair was repaired with a single plate, whereas the contralateral scapula was repaired with 2 plates. Initial strength and stiffness of the constructs were measured in 10 pairs of scapulae. Eight pairs of scapulae underwent cyclic loading and then were subjected to failure testing. RESULTS: Double-plate fixation was significantly stronger (3,899 +/- 632 N) but not stiffer (614 +/- 130 N/mm) than the single-plate fixation (3,238 +/- 935 N and 537 +/- 202 N/mm, respectively). Cyclic loading variables were not significantly different between the 2 methods of fixation. After cyclic loading, double-plate fixation was significantly stronger (2,916 +/- 618 N) than single-plate fixation (2,347 +/- 495 N). There was no significant difference (P =.11) in stiffness between double- versus single-plate fixations: 734 +/- 247 N/mm and 595 +/- 139 N/mm, respectively. CONCLUSIONS: Double-plate fixation was generally stronger and stiffer than single-plate fixation. Because all constructs failed at loads that greatly exceeded those estimated to occur clinically, any difference between the 2 methods of fixation probably is not clinically relevant. CLINICAL RELEVANCE: Single-plate fixation may be of sufficient strength for fixation of scapular body fractures.

Animals↗

Comparison of early and delayed fixation of subcapital hip fractures in patients sixty years of age or less.

BACKGROUND: Subcapital hip fractures in younger patients are generally treated with internal fixation rather than with primary hemiarthroplasty, which is generally reserved for older, low-demand patients. Avascular necrosis can occur following this injury because of disruption of the femoral head blood supply. Some believe that emergent fracture reduction is necessary to minimize the risk of avascular necrosis. The purposes of this study were (1) to investigate the functional outcomes of subcapital hip fractures in patients sixty years old or younger and (2) to compare the rates of avascular necrosis after early and delayed fracture fixation. METHODS: This retrospective study included adults in whom a subcapital hip fracture had been treated with reduction and internal fixation when they were sixty years of age or less and who had been followed clinically for a minimum of two years. The patients were divided into two groups: those treated with early fixation (within twelve hours after the injury) and those treated with delayed fixation (more than twelve hours after the injury). Functional outcomes were assessed with use of the Short Form-36 and the Western Ontario and McMaster University (WOMAC) Osteoarthritis Index. The rates of avascular necrosis were compared between the two groups. RESULTS: Thirty-eight patients (average age, 46.4 years) participated in the study. Twenty-nine patients had a displaced subcapital hip fracture. Fifteen patients underwent early fracture fixation, and the remainder underwent delayed fixation. No differences in the Short Form-36 (p = 0.68) or WOMAC (p = 0.69) scores were seen between the early and delayed fixation groups. Radiographic evidence of avascular necrosis developed in six patients treated with delayed fixation, one of whom had had an undisplaced fracture preoperatively, and in no patient treated with early fixation. The difference in the rates of avascular necrosis was significant (p = 0.03). CONCLUSIONS: Although delayed surgical treatment of subcapital hip fractures was associated with a higher rate of avascular necrosis, this complication did not significantly affect functional outcome. Longer follow-up is required to assess the effect of avascular necrosis on the development of arthritis and on long-term patient function. Although the results could be biased because patients were not randomly assigned to delayed or early fixation, the data suggest that urgent reduction and fracture fixation within twelve hours after a displaced subcapital hip fracture in high-demand patients may be associated with a reduced rate of radiographic signs of avascular necrosis.

Adult↗

Titanium miniplates or stainless steel wire for cranial fixation: a prospective randomized comparison.

OBJECT: The authors designed a study to compare low-profile titanium miniplate fixation to that in which stainless steel wire is used. METHODS: Before undergoing craniotomy, 40 patients gave informed consent and were randomized to receive either wire or miniplate fixation. After dural closure, bone flap fixation was timed. The bone flap was measured for inward or outward offset and mobility to manual pressure on its margin. Three months postoperatively the bone flap margins were graded for appearance or palpation of an offset and for the presence of burr hole depressions. Twenty-four patients were randomized to receive miniplate fixation and 16 to receive stainless steel wire fixation. The time required for wire fixation was approximately 40% longer than that for miniplates (11.8 +/- 5.1 minutes compared with 8.3 +/- 5 minutes, p = 0.02). The offset of bone flaps after wire fixation was significantly greater than that with miniplates (1.6 +/- 1 mm compared with 0.3 +/- 0.6 mm, p < 0.001), as was the mobility of the bone flap on digital pressure (1.2 +/- 0.9 mm compared with 0.2 +/- 0.5 mm, p < 0.001). At the 3-month follow-up review, two of 12 patients had suboptimal results after wire fixation, whereas none of 14 patients had suboptimal results after miniplate fixation. When dichotomized for excellent or less-than-excellent postoperative results, the data were significantly better for patients who underwent miniplate fixation (p < 0.05). CONCLUSIONS: Titanium miniplate cranial fixation provides more accurate and rigid reapproximation of the bone edges, with results that are significantly better on close inspection or palpation. The additional cost of miniplate fixation may thus be justified in many cases.

Adult↗

Biologic and biomechanic evaluation of posterior lumbar fusion in the rabbit. The effect of fixation rigidity.

STUDY DESIGN: The histologic and biomechanic characteristics of posterior lumbar fusion with varying rigidity of a novel internal fixation construct in the rabbit were analyzed. OBJECTIVES: To evaluate this rabbit model for future studies of fusion augmentation. SUMMARY OF BACKGROUND DATA: Previous studies in goats and dogs showed internal fixation enhances spinal arthrodesis. METHODS: Twenty eight New Zealand white rabbits underwent a posterior midline fusion from L4 to L6. Some animals received autogenous iliac crest bone graft, stabilized by wiring the superior facets bilaterally, and supplementation with polymethylmethacrylate. The experimental groups were iliac crest bone graft with either no fixation, wire fixation, or wire and polymethylmethacrylate fixation; and no graft and either no fixation, wire fixation, or wire and polymethylmethacrylate fixation. Animals were killed 2 months after surgery, and the specimens were nondestructively tested biomechanically for stiffness in six modes (flexion, extension, left and right bending, compression, and torsion) and histologically for evidence of fusion, revascularization, and new bone formation. RESULTS: Fusions with either wire or wire and polymethylmethacrylate fixation were significantly stiffer than those without fixation (P < 0.05). There was no statistical difference between the iliac crest bone graft and wire group and the iliac crest bone graft, wire, and polymethylmethacrylate group in the modes tested. Nine of 14 motion segments receiving the stiffest construct (iliac crest bone graft, wire, and polymethylmethacrylate) had evidence of solid bony fusion. None of the 12 motion segments receiving iliac crest bone graft and wire had evidence of bony fusion, but five had a fibrocartilage union with some ossification present. Eight of 12 motion segments receiving iliac crest bone graft and no fixation had predominantly fibrous unions with some fibrocartilage, and only one motion segment of 12 showed bony fusion. CONCLUSIONS: This study suggests that more rigid fixation produces more successful union in rabbit posterior spinal fusion. This model may be useful in evaluating the ability of various biomaterials to augment spinal arthrodesis.

Animals↗

Biomechanics and biology of fracture repair under external fixation.

The major factors determining the mechanical milieu of a healing fracture under external fixation, and thereby the mechanism of union, are the rigidity of the selected fixation device, the fracture configuration, the accuracy of fracture reduction, and the amount of physiologic stresses dictated by functional activity and loading. Bone healing problems encountered in fractures stabilized externally merely reflect the severity of the local soft-tissue and periosteal injury and should not be attributed to the inherent features of the fixation modality. Although some surgeons have had reservations concerning the use of external fixation for fracture treatment, based mainly on concerns of pin-tract infection and fracture nonunion, much of the clinical experience and basic science research results have proven the reverse. Many of the potential benefits of external fixation, such as the change of fixation stiffness, are not yet fully appreciated. Additional research and well-organized clinical trials must be performed. Pin-tract problems can be controlled, but the surgeon using such a device must be familiar with the techniques and follow the established regimens during postoperative care. One common mistake is to assume that external fixators, especially those of the simpler unilateral configuration, are easy to use and do not require learning or mastering the surgical techniques until the time of application. Periodic examination and radiographic evaluations are also essential to adjust conditions of the fracture site. The importance of balancing the biomechanical properties and the biologic consequences of different external fixation modalities has been demonstrated. Understanding this knowledge and the techniques of application associated with external fixation is the prerequisite to successful treatment. Some of the basic biomechanical information related to external fixation and bone fracture union is still unknown. This lack should provide the impetus for surgeons, bioengineers, and medical scientists to continue collaborative basic and applied research. Furthermore, by recognizing the proper cell mediators and the physical means to stimulate these cellular elements, the bone fracture healing process may be modulated, regardless of the fixation technique. The result of such effort should provide new modalities to improve fracture management.

Animals↗

Soft-tissue graft fixation in posterior cruciate ligament reconstruction: evaluation of the effect of tibial insertion site on joint kinematics and in situ forces using a robotic/UFS testing system.

INTRODUCTION: Surgical reconstruction of the posterior cruciate ligament (PCL) is recommended in acute injuries that result in severe tibial subluxation and instability. The surgical outcome level may be affected by the tibial fixation site. In response to a 110-N posterior tibial load, kinematics and in situ forces of anatomical soft-tissue graft fixation in single-bundle PCL reconstruction using an interference screw fixation are significantly closer to those in the intact knee than with extracortical fixation with two staples. MATERIALS AND METHODS: Using a robotic/universal force moment sensor (UFS) testing system, we examined joint kinematics and in situ forces of porcine knees following single-bundle PCL reconstruction fixed at two different tibial fixation sites: anatomical interference screw and extracortical fixation. RESULTS: The site of the tibial graft fixation had significant effect on the resulting posterior displacement and in situ forces of the graft. Both PCL reconstruction techniques reduced the posterior tibial translation significantly. Proximal fixation techniques provided significantly less posterior tibial translation than extracortical fixation. Single-bundle PCL reconstruction with an interference screw showed higher in situ forces of the graft than the extracortical fixation. CONCLUSIONS: The kinematics and in situ forces of a single-bundle PCL reconstruction using an interference screw fixation technique are superior to the primary stability of an extracortical fixation with staples.

Animals↗

Comparison of the mechanical performance of three types of external fixators: linear, circular and hybrid.

Different configurations of the Monticelli-Spinelli and Ilizarov external fixation systems were tested to define their mechanical properties. In five configurations the external fixator consisted of rings with tensioned wires (circular), while in one configuration two pairs of the tensioned wires and their correspondent ring were replaced by threaded pins (hybrid). Testing was performed in axial compression, bending and torsion. The results were compared to the characteristics of a selected linear fixator group. Both the circular and the hybrid configurations were non-linear in compression. In bending, circular fixators had a similar pattern in both anteroposterior and oblique loading directions. The bending load-displacement pattern for the hybrid fixators was similar to the linear fixators, higher stiffness in the plane of the pins. Torsion was linear for both circular and hybrid fixators, as for the linear fixators. By combination of wires and pins (hybrid configuration), the mechanical behaviour had characteristics from both linear and circular fixators. It is concluded that the three studied groups own different mechanical performance and can be considered as different types of fixators. While it has been demonstrated that osteogenesis can be achieved independently of the mechanical behaviour of the fixator, this study supports the suggestion that some complications can be related to the mechanical behaviour of the fixator.

Journal Article↗

Biomechanical testing of hamstring graft tibial tunnel fixation with bioabsorbable interference screws.

PURPOSE: This study evaluated the failure mode, maximum load at failure, displacement at failure, and stiffness differences of quadrupled hamstring graft-tibial tunnel fixation using 28-mm, tapered 35-mm, or bicortical 17- and 20-mm bioabsorbable interference screws (Arthrex, Naples, FL). TYPE OF STUDY: Biomechanical study. METHODS: Nine matched pairs (18 specimens) of young cadaver tibias (mean bone mineral density [BMD] = 0.847 g/cm2, range, 0.689 to 1.11 g/cm2) were divided into 3 groups of 6 specimens. Kruskal Wallis analysis of variance and Mann-Whitney U tests post hoc comparisons were used to assess group differences (P <.05). RESULTS: Maximum load at failure for the 28-mm screw was 488.2 +/- 197 N, with a displacement of 18.4 +/- 7.5 mm and a stiffness modulus of 38.9 +/- 7.0 N/mm. Maximum load at failure for the tapered 35-mm screw was 844.8 +/- 121.4 N, with a displacement of 15.3 +/- 1.6 mm and a stiffness modulus of 70.5 +/- 21.1 N/mm. Maximum load at failure for bicortical screw fixation was 543.7 +/- 266.5 N, with a displacement of 17.7 +/- 6.6 mm and a stiffness modulus of 57.7 +/- 14.9 N/mm. Fixation using the tapered 35-mm screw displayed greater maximum load at failure than either 28-mm screw fixation (P =.015) or bicortical screw fixation (P =.037). Significant differences were not evident for displacement. Both tapered 35-mm (P =.016) and bicortical screw (P =.026) fixation displayed greater stiffness than 28-mm screw fixation. All constructs failed by pullout. CONCLUSIONS: Fixation using a single tapered 35-mm screw displayed increased maximum load at failure compared with the 28-mm screw or bicortical fixation. Both the tapered 35-mm screw and bicortical fixation showed greater stiffness than fixation using a 28-mm screw. Use of a single 35-mm screw for quadrupled hamstring graft-tibial tunnel fixation may be preferred for patients with poor tibial BMD.

Absorbable Implants↗

Selection of fixation devices in proximal femur rotational osteotomy: clinical complications and finite element analysis.

OBJECTIVE: To compare the postoperative stability between large cancellous screws fixation and dynamic hip screws fixation in transtrochanteric rotational osteotomy. DESIGN: Finite element analysis was designed to validate the clinical outcomes of fixation failure in transtrochanteric rotational osteotomy. BACKGROUND: From 1997 to 2000, transtrochanteric rotational osteotomy had been done in 20 osteonecrotic hips. Fixation with large cancellous screws as suggested by Sugioka had been used in the first five hips. Unfortunately, fixation failures were encountered in all of the five cases. The fixation mode was then shifted to a combination of plate and screws, no fixation failure had been observed postoperatively. A finite element analysis was designed to investigate the causes of fixation failure. METHODS: Finite element models for four dynamic hip screw instrumented femora and four large screws instrumented femora simulating four different levels of bone cut were created. The von Mises stress distributions of each model were analyzed and compared for a loading condition simulating single-legged stance. RESULTS: Analysis results confirmed our clinical observation that fixation with screws had higher stress concentration on the proximal femur. Improper bone cut, especially those that are too distal from the intertrochanteric line, had higher risks of fixation failure. CONCLUSIONS: Transtrochanteric rotational osteotomy is a technically demanding procedure such that surgical principles should be abided carefully to avoid catastrophic complications. RELEVANCE: Finite element analysis results demonstrated that dynamic hip screw fixation provides better stability and prevents fixation failure that corresponds with the clinical observation.

Adult↗

The role of aortic neck dilation and elongation in the etiology of stent graft migration after endovascular abdominal aortic aneurysm repair with a passive fixation device.

OBJECTIVE: Endovascular repair of abdominal aortic aneurysm (AAA) is complicated by the potential for stent graft migration over time. Factors including the type of fixation, initial proximal fixation length, and dilation and elongation of the infrarenal aortic neck may contribute to device migration. We sought to determine when device migration is a real phenomenon with actual device movement that compromises aneurysm exclusion. METHODS: Computed tomographic (CT) scans and computer reconstructions of all patients undergoing endovascular AAA repair with a passive fixation device at our institution from June 1996 to October 2004 were retrospectively reviewed. The distance from the distal renal artery to the proximal end of the stent graft at the time of initial deployment was determined for each patient. Migration was defined as a distance increase greater than 5 mm in the follow-up period; proximal fixation length, aortic neck enlargement and elongation, and neck angle were then measured. Data were further analyzed with respect to AAA growth, development of endoleak, AAA rupture, and the need for reintervention. RESULTS: A total of 308 patients with endovascular AAA repairs using a passive fixation device had complete postoperative imaging data sets; 48 patients (15.6%) with stent graft migration of 5 mm or more were identified, and 25 (8.1%) of these had a migration of 10 mm or more. Seventeen (35.4%) of 48 migration patients had a total loss of the proximal seal zone (loss patients); their average migration distance was 17.7 +/- 12.0 mm, with a mean neck shortening of 13.6 +/- 14.2 mm, and the average proximal fixation length loss was 14.0 +/- 7.6 mm. Those 31 patients with an intact proximal seal zone (nonloss patients) showed an average migration of 9.4 +/- 3.7 mm, with a mean neck lengthening of 9.6 +/- 8.4 mm and an average proximal fixation length change of 0.7 +/- 8.0 mm. Univariate analysis demonstrated significant differences between the loss and nonloss patients in follow-up duration (65.9 +/- 20.4 months vs 45.9 +/- 26.4 months; P = .01), neck dilatation at the distal renal artery (4.6 +/- 4.5 mm vs 1.8 +/- 1.9 mm; P = .026), stent graft migration distance (17.7 +/- 12.0 mm vs 9.4 +/- 3.7 mm; P = .001), change in aortic neck length (-13.6 +/- 14.2 mm vs 9.6 +/- 8.4 mm; P < .0001), change in proximal fixation length (-14.0 +/- 7.6 mm vs 0.7 +/- 8.0 mm; P < .0001), change in AAA size (1.8 +/- 7.1 mm vs -3.6 +/- 9.7 mm; P = .033), and use of a stiff body stent graft (47.1% vs 19.4%; P = .043). However, only change in aortic neck length was statistically significant on multivariate analysis (odds ratio, 0.75; 95% confidence interval, 0.591-0.961; P = .022). There were no differences between the loss and nonloss patients in time to migration discovery, initial AAA size, initial aortic neck diameter or length, initial device oversizing, initial neck angle, neck angle increase, type II endoleak, or AAA rupture. Eight of the 17 loss patients have been treated with proximal aortic cuffs; the remainder have refused reintervention, died of unrelated causes, or elected to have open repair. CONCLUSIONS: Postoperative elongation of the infrarenal aortic neck may create the radiographic perception of migration without necessarily causing a loss of proximal stent graft fixation. Patients with a total loss of the proximal seal zone actually have infrarenal aortic neck shortening, with a degree of neck dilatation beyond initial device oversizing that may compromise proximal fixation length. Conversely, those with an intact proximal seal zone demonstrate aortic neck elongation equivalent to migration, with no loss of proximal fixation length; these patients have a benign natural history without intervention. Thus, aortic neck dilatation beyond oversizing, aortic neck shortening, and loss of proximal fixation length are more clinically relevant predictors of proximal stent graft failure than simple migration distance.

Angioplasty↗

Adjusting intraocular lens power for sulcus fixation.

PURPOSE: To determine the appropriate correction of predicted intraocular lens (IOL) power for sulcus fixation and to prospectively assess the validity of the obtained correction value in patients having sulcus fixation. SETTING: Department of Ophthalmology, Saiseikai Kurihashi Hospital, Saitama, Japan. METHODS: The postoperative refraction, virtual in-the-bag IOL power for the same postoperative refraction, predicted refraction with an increase in in-the-bag IOL power by 0.50 to 2.00 diopters (D), and effective lens position (ELP) in 30 eyes with a normal axial length after sulcus fixation were retrospectively evaluated. The results were confirmed prospectively in 16 other eyes requiring sulcus fixation. RESULTS: A significant myopic shift (mean 0.78 D +/- 0.47 [SD]) from the predicted refraction occurred after sulcus fixation (P<.0001). The mean virtual IOL power was 1.11 +/- 0.67 D higher than that of the actual sulcus-fixated IOL. The difference between the predicted refraction and the refraction after sulcus fixation was less when the difference in IOL power was 1.00 D. The ELP of the IOLs was 0.75 mm shorter using A-mode measurement and 0.62 mm shorter using back calculation from the theoretical formula with sulcus fixation than with in-the-bag fixation. In the prospective study, there was a small refractive error (mean -0.06 +/- 0.19 D) when the planned IOL power was reduced by 1.00 D for sulcus fixation. CONCLUSION: For sulcus fixation in eyes with a normal axial length, the IOL power should be 1.00 D less than the power for in-the-bag fixation.

Aged↗

Why abaxial illumination limits photosynthetic carbon fixation in spinach leaves.

Limitations of carbon fixation within spinach leaves due to light and CO2 were investigated. Under equivalent photon fluxes, carbon fixation was higher when leaves were irradiated adaxially compared to abaxially. Maximal carbon fixation occurred in the middle of the palisade mesophyll under adaxial illumination, whereas, maximal carbon fixation occurred in the spongy mesophyll under abaxial illumination. Total carbon fixation and the pattern of carbon fixation across leaves were similar, when leaves were irradiated with 800 micromol quanta m(-2) s(-1) either adaxially alone or adaxially plus abaxially (1,600 micromol quanta m(-2) s(-1)). In contrast, when both leaf surfaces were irradiated simultaneously with 200 micromol quanta m(-2) s(-1), total carbon fixation increased and carbon fixation in the middle of the leaf was higher compared to leaves irradiated unilaterally with the low light. Feeding 14CO2 through either the adaxial or abaxial leaf surface did not change the pattern of carbon fixation across the leaf. Increasing 14CO2 pulse-feeding times from 5 s to 60 s allowed more 14CO2 to be fixed but did not change the pattern of 14CO2 fixation across the leaf. We concluded that in spinach, the distribution of both light and Rubisco activity within leaves has significant effects on the patterns of carbon fixation across leaves; whereas CO2 diffusion does not appear to affect the carbon fixation pattern within spinach leaves.

Carbon Dioxide↗