Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “CEMENTATION”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36Linked to original sources

Microleakage of various cementing agents for full cast crowns.

OBJECTIVES: To evaluate microleakage and marginal gaps in full cast crown restorations bonded with six different types of cementing agents. METHODS: Sixty non-carious human premolars and molars were prepared in a standardized manner for full cast crown restorations. The mesial and distal margins were located in dentin, while the vestibular and palatal/lingual margins were located in enamel. Crowns were made from a high-gold alloy using a standardized technique. The specimens were randomized to six groups of cementing agents: one zinc-phosphate cement (Harvard cement), one conventional glass-ionomer cement (Fuji I), one resin-modified glass-ionomer cement (Fuji Plus), two standard resin cements (RelyX ARC, Panavia F), and one self-adhesive universal resin cement (RelyX Unicem). After 4 weeks of storage in distilled water at 37 degrees C, the specimens were subjected to 5000 thermocycles ranging from 5 to 55 degrees C. Then, they were placed in a silver nitrate solution, embedded in resin blocks, and vertically cut in buccolingual and mesiodistal direction. Subsequently, the objects were evaluated for microleakage and marginal gap using a high-resolution digital microscope camera. RESULTS: A number of inter-group differences were statistically significant. RelyX Unicem showed the smallest degree of microleakage both in enamel and in dentin. Panavia F und RelyX Unicem were associated with significantly larger marginal gaps than all other cementing agents. No association was observed between microleakage and marginal gap other than a weak direct correlation when using Harvard cement on enamel. SIGNIFICANCE: The cementing agents investigated revealed different sealing abilities. These differences were not associated with specific types of materials.

Bisphenol A-Glycidyl Methacrylate↗

Fracture resistance of metal-free composite crowns-effects of fiber reinforcement, thermal cycling, and cementation technique.

STATEMENT OF PROBLEM: The improved mechanical properties of contemporary composites have resulted in their extensive use for the restoration of posterior teeth. However, the influence of fiber reinforcement, cementation technique, and physical stress on the fracture resistance of metal-free crowns is unknown. PURPOSE: This in vitro study evaluated the effect of fiber reinforcement, physical stress, and cementation methods on the fracture resistance of posterior metal-free Sinfony crowns. MATERIAL AND METHODS: Ninety-six extracted human third molars received a standardized tooth preparation: 0.5-mm chamfer preparation and occlusal reduction of 1.3 to 1.5 mm. Sinfony (nonreinforced crowns, n=48) and Sinfony-Vectris (reinforced crowns, n=48) crowns restoring original tooth contour were prepared. Twenty-four specimens of each crown type were cemented, using either glass ionomer cement (GIC) or resin cement. Thirty-two crowns (one third) were stored in humidity for 48 hours. Another third was exposed to 10,000 thermal cycles (TC) between 5 degrees C and 55 degrees C. The remaining third was treated with thermal cycling and mechanical loading (TCML), consisting of 1.2 million axial loads of 50 N. The artificial crowns were then vertically loaded with a steel sphere until failure occurred. Significant differences in fracture resistance (N) between experimental groups were assessed by nonparametric Mann-Whitney U-test (alpha=.05). RESULTS: Fifty percent of the Sinfony and Sinfony-Vectris crowns cemented with glass ionomer cement loosened after thermal cycling. Thermal cycling resulted in a significant reduction in the mean fracture resistance for Sinfony crowns cemented with GIC, from 2037 N to 1282 N (P=.004). Additional fatigue produced no further effects. Fiber reinforcement significantly increased fracture resistance, from 1555 N to 2326 N (P=.001). The minimal fracture resistance was above 600 N for all combinations of material, cement and loading. CONCLUSION: Fracture resistance of metal-free Sinfony crowns was significantly increased by fiber reinforcement. Adhesive cementation may be recommended to avoid cementation failure.

Air Abrasion, Dental↗

Acidic solubility of luting cements.

OBJECTIVES: Chemical disintegration of luting cements can adversely affect their long term success. The aim of the present study was to assess the susceptibility of zinc phosphate cement, glass ionomer cement and resin cement to erosion at various pH values. METHODS: Zinc phosphate and glass ionomer cement samples were eroded in 0.3% citric acid adjusted to pH 3.0, 4.0, 5.0, 6.0 and 7.0 at a temperature of 35 degrees C. A control group was stored in saline. Profilometric readings were performed after 30 min and 1h erosion time. Resin cement samples were eroded at pH 3.0 with measurements after 30 min, 6h, 24h and 7 days. A saline control group was measured after 7 days. RESULTS: Erosion of zinc phosphate cement was significantly higher at all pH values than erosion of glass ionomer cement with erosion depth increasing with decreasing citric acid pH. No erosion was seen in the control groups. The resin cement did not show any change in surface profile after the 7 day erosion period compared to the control group. Comparison to dental tissues revealed that erosion of glass ionomer cement in vitro was slightly lower than erosion of enamel and dentine. In contrast, erosion of zinc phosphate cement was much higher.

Acids↗

Microleakage along Glassix glass fibre posts cemented with three different materials assessed using a fluid transport system.

AIM: To evaluate the microleakage along Glassix fibre posts cemented with three different materials. METHODOLOGY: The root canals of maxillary central incisor teeth were filled and restored with Glassix posts (Harald Nordin sa, Chailly/Montreux, Switzerland) cemented with either a zinc-phosphate Harvard cement (Richter & Hoffmann, Harvard Dental GmbH, Berlin, Germany), Fuji PLUS cement (GC Corporation, Tokyo, Japan) or Variolink II cement (Vivadent, Schaan, Lichtenstein) in three groups of 15 canals each. Twenty unrestored canals served as a control group, 10 filled with gutta-percha and sealer (negative control group), the remaining 10 with gutta-percha only (positive control group). Coronal microleakage was evaluated using a fluid transport system. The movement of an air bubble in a capillary glass tube connected to the apex of the experimental root section was measured over 5-min periods. Measurements were performed four times for each specimen and the mean values recorded. ANOVA and Duncan's test were performed. RESULTS: The positive control group had the highest values of microleakage. Amongst experimental groups, the highest values of microleakage occurred in the group with the posts cemented with Harvard cement, followed by Fuji PLUS and Variolink II cements. Groups with Fuji PLUS, Variolink II and the negative control group had significantly (P < 0.00001) less microleakage compared with the Harvard cement group and the positive control group. CONCLUSION: Canals with Glassix posts cemented with Variolink II and Fuji PLUS cement had the least leakage when assessed using a fluid transport system.

Air↗

Specification test for the solubility and disintegration of dental cements: a critical evaluation of its meaning.

The specification test for solubility and disintegration is an essential screening test for the quality control of certain cement types. No cement fails it can be considered for use; however, the test has only a limited clinical significance because it does not give an indication of the stability of the fully hardened cement matrix either in oral fluids or water. Instead, it gives a measure of the content of the soluble reaction intermediate present in cements that are still hardening and where the matrix has not fully formed. The test relates, therefore, to early vulnerability to aqueous attack and hardening rate. The period of test is, in fact, an atypical one and the true extent of the erosion of the cement matrix is obscured by the presence of soluble reaction intermediates. Long-term extrapolations cannot be made and so test results for broadly satisfactory cements within a category cannot be used for valid comparisons of clinical excellence, and they can be used even less to compare different cement types with different setting reactions. For example, in general, the dental silicate cement has a higher solubility and distinegration figure than the zinc phosphate cement because it contains soluble sodium salt and hardens more slowly. However, it is more stable under oral conditiont an indication of the vulnerability of the forming matrix to attack. The test is not valid when applied to zinc oxide-eugenol cements because the products of decomposition are either virtually water-insoluble or volatile and therefore not measured under the conditions of the test. A method is suggested for overcoming this deficiency. The test needs to be supplemented by other tests done on fully hardened cements for longer periods of time and in mediums that can represent oral conditions. One example would be to stimulate acid conditions developed in stagnation areas. A total estimation of decomposition products, both soluble and insoluble, is called for rather than the determination of soluble materials only.

Absorption↗

Effect of cement types on the tensile strength of metallic crowns submitted to thermocycling.

The relationship between metallic cast crowns and tensile strength according to cement types submitted to thermocycling was studied. Seventy-two metallic crowns were cast with Verabond II Ni-Cr alloy and cemented in standardized preparations with 10 masculine tapering. Three types of finishing line (45-degree chamfered, 20-degree bevel shoulder and right shoulder) were made with diamond burs on bovine teeth. Twenty-four metallic crowns in each group were randomly subdivided into three subgroups of 8 samples each according to the cement used: SS White zinc phosphate cement, Vitremer resin-modified glass ionomer cement, and Rely X resin cement and were submitted to thermocycling. Retention was evaluated according to tensile load required to displace the metallic cast crowns from tooth preparations with an Instron testing machine. ANOVA and Tukey's test showed a statistically significant difference among luting materials, with greater results for Rely X resin cement (24.9 kgf) followed by SS White zinc phosphate cement (13.3 kgf) and Vitremer resin-modified glass ionomer cement (10.1 kgf). The finishing line types did not influence the tensile resistance of the crowns fixed with the three cements. Increased tensile resistance of metallic crowns fixed on bovine teeth was obtained with resin cement, independent of the finishing line types.

Animals↗

A retrospective observational study of the effect of surface treatments and cementing media on the durability of gold palatal veneers.

This paper reports on the results of a retrospective observational study that sought to determine both the longevity and effects of surface treatments of gold palatal veneers used to restore tooth surface loss. Details of all gold palatal veneers fabricated from Mattident 60 were sourced from hospital records spanning 11 years and 9 months. The case notes of each individual were accessed and, for each restoration, a note was made of the date and method of cementation, together with the period of patient follow-up. When patients continued their routine checkups, the records were scrutinized closely for evidence of restoration failure. This yielded a data set of 151 palatal gold veneer cementations for which the surface treatments and/or cementing media were known. Survival analysis by the Kaplan-Meier method of alumina blasted veneers revealed median survival times of 4,663 days when cemented with Panavia 21 and 687 days if cemented with Aquacem. Veneers that were alumina blasted, oxidized and cemented with Panavia 21 had a survival probability of 1.0. A Logrank test revealed highly statistically significant differences between the survival curves (p<0.0001). It was concluded that: (1) Alumina blasting the fit surface of a gold veneer prior to cementation with Panavia 21 resulted in a significantly more durable restoration compared to alumina blasting and cementation with Aquacem and no etching of tooth substance. (2) Due to low MST cementing, gold palatal veneers with a conventional glass polyalkenoate cement are not recommended. (3) Pre-treatment of gold palatal veneers by alumina blasting and oxidation prior to cementing with Panavia 21 appears to improve the chances of obtaining a dependable restoration. A greater number of restorations would be required to statistically test this trend.

Acid Etching, Dental↗

Laser ablation of dyed acrylic bone cement.

Revision surgery of cemented implants is indicated when mechanical failure causes severe pain and/or loss of function for the patient. Successful revision arthroplasty of cemented implants requires complete removal of the existing cement. Removal of old cement is an arduous task often causing damage to the surrounding bone tissue. In this study, the authors investigate the use of an Argon laser and the addition of dyes to enhance the laser ablation of bone cement. Methylene blue and red dye #13 were each added separately to polymethylmethacrylate (PMMA) bone cement powder. A continuous wave Argon ion laser (lambda = 514 nm) was used for cement ablation. Cement samples were ablated at different power levels (1.5, 2.3, and 3.0 W) and exposure times (30, 60, 90, 120 sec). The results show that the Argon laser was unable to ablate undyed PMMA. However, the addition of either methylene blue or red dye #13 greatly improved cement ablation by altering the cements' absorption characteristics. Results of Student's t-tests show a statistical difference between red and blue dyed PMMA mean ablation areas at all energy levels tested (P < .0002). As expected, all red ablation areas were greater than blue ablation areas at each energy level tested since red dye absorbs more energy at 514 nm than methylene blue dye. The results of this study suggest that by selectively altering the absorption characteristics of PMMA, laser removal of bone cement can be achieved. In addition, this study also shows that bone tissue does not absorb visible light energy at 514 nm, suggesting that bone cement may be removed with minimal damage to the surrounding bone tissue.

Bone Cements↗

Mechanical and biological properties of two types of bioactive bone cements containing MgO-CaO-SiO2-P2O5-CaF2 glass and glass-ceramic powder.

In this study two types of bioactive bone cement containing either MgO-CaO-SiO2-P2O5-CaF2 glass (type A) or glass-ceramic powder (type B) were made to evaluate the effect of the crystalline phases on their mechanical and biological properties. Type A bone cement was produced from glass powder and bisphenol-a-glycidyl methacrylate (BIS-GMA) resin, and type B from glass-ceramic powder containing apatite and wollastonite crystals and BIS-GMA resin. Glass or glass-ceramic powder (30, 50, 70, and 80 by wt %) was added to the cement. The compressive strength of type A (153-180 MPa) and B (167-194 MPa) cement were more than twice that of conventional polymethylmethacrylate (PMMA) cement (68 MPa). Histological examination of rat tibiae showed that all the bioactive cements formed direct contact with the bone. A reactive layer was seen at the bone-cement interface. In specimens with type A cement the reactive layer consisted of two layers, a radiopaque outer layer (Ca-P-rich layer) and a relatively radiolucent inner layer (low-calcium-level layer). With type B cement, although the Ca-P-rich layer was seen, the radiolucent inner layer was absent. Up to 26 weeks there was progressive bone formation around each cement (70 wt %) and no evidence of biodegradation. The mechanical and biological properties of the cements were compared with those of a previously reported bone cement containing MgO-free CaO-SiO2-P2O5-CaF2 glass powder (designated type C).

Animals↗

Mechanical and biological properties of bioactive bone cement containing silica glass powder.

Silica glass powder (SG-P) made by a fusing-quenching method was added as a second filler to a bioactive bone cement consisting of MgO-CaO-SiO2-P2O5-CaF2 apatite and wollastonite containing glass-ceramic powder (AW-P) and bisphenol-a-glycidyl methacrylate (Bis-GMA)-based resin, to achieve a higher mechanical strength and better handling properties in use. Five types of cement were used, containing different weight ratios of AW-P/SG-P (Group 1 = 100/0; Group 2 = 75/25; Group 3 = 50/50; Group 4 = 25/75; and Group 5 = 0/100) as filler, to evaluate the effect of SG-P content on the biological, mechanical, and handling properties. The total proportion of filler added to the cements was 85% w/w. The compressive, bending, and tensile strengths and fracture toughness of the cements increased with SG-P content. The viscosity of cements also increased with SG-P content, and every cement could be handled manually. The cements were evaluated in vivo by packing the intramedullary canals of rat tibiae. An affinity index was calculated for each cement; this was the length of bone directly apposed to cement expressed as a percentage of the total length of the cement surface. Histological examination of implanted tibiae for up to 26 weeks showed that the affinity indices decreased with SG-P content and that those of all the cement groups increased with time. At 26 weeks, Groups 1 and 2 had almost identical affnity indices (79% and 75%; no significant difference) but those of the other groups remained at <50%. Group 2 had better mechanical and handling properties than Group 1, and an SG-P content in the filler of no more than 25% w/w did not interfere strongly with the bioactivity of the cement.

Animals↗

Comparison of diametral shrinkage of centrifuged and uncentrifuged Simplex P bone cement.

Reducing the porosity of bone cement substantially strengthens the cement in fatigue. However, concern has been raised that reducing the porosity of the cement would increase the shrinkage of the cement and thus compromise the cement-bone interface. We measured diametral shrinkage of cement mantles prepared with and without centrifugation of the cement. Four cement preparations (centrifuged and uncentrifuged mixed with monomer at either room temperature or 0 degrees C) were used to form cement mantles of four different thicknesses (2, 4, 6, and 8 mm) around a stainless steel rod. We conclude that porosity reduction dramatically increases the fatigue strength of bone cement without substantially changing the diametral dimensions of the polymerized cement when studied in the shape and volume of a cement mantle that would be used for total hip replacement.

Biocompatible Materials↗

Use of injectable calcium-phosphate cement for the fixation of titanium implants: an experimental study in goats.

This in vivo study evaluated the fixation of two types of titanium implants with the use of an injectable calcium-phosphate (CaP) cement. The cement was either used to create a cement mantle (Type A implant) or as an additive to press-fit placed titanium plasma sprayed implants (Type B implant). The implants were placed in trabecular bone of the medial femoral condyle of goats and left in place for 2 and 10 weeks. Mechanical evaluation of the implant fixation was done by torque testing. This showed that for the Type A implants the calcium-phosphate cement's performance was significantly inferior (P < 0.05) to that of polymethylmethacrylate cement fixation. For the two-week Type B implants a significant increase (P < 0.05) in failure load was found for calcium-phosphate cemented implants compared with just press-fitted Type B implants. Histological evaluation revealed that for Type A implants, failure during torque testing occurred at the implant-cement interface. In contrast, for Type B implants, failure occurred in the bone-implant interface for press-fit-placed devices and in the cement layer for CaP-cemented devices. Further, the CaP cement was found to be overgrown with new formed bone already after 2 weeks of implantation. The cement showed resorption due to regular bone remodeling. On the basis of these observations, it was concluded that the use of injectable CaP cement might facilitate earlier loading of press-fit inserted titanium implants. Nevertheless, the results have to be confirmed in dynamical mechanical as well as loaded in vivo studies.

Animals↗

Graft copolymers of methyl methacrylate and poly([R]-3-hydroxybutyrate) macromonomers as candidates for inclusion in acrylic bone cement formulations: Compression testing.

Graft copolymers of methyl methacrylate and biodegradable, biocompatible bacterial poly([R]-3-hydroxybutyrate) (PHB) blocks were synthesized and evaluated as possible constituents in acrylic bone cements for use in orthopaedic applications. The copolymers were produced by conventional free radical copolymerization and incorporated in one commercially available acrylic bone cement brand, Antibiotic Simplex (AKZ). Cements with formulations containing 6.7 and 13.5 wt % of PMMA-graft-PHB were prepared. The morphology of the graft copolymer particles was suggested to influence the ability of the modified cement to be processed. Formulations containing more than about 20 wt % of the graft copolymer resulted in cement doughs that, both after first preparation and several hours later, were either sandy or soft spongy in texture and, thus, would be unacceptable for use in orthopaedic applications. The morphologies of the powders and the volumetric porosity (p) and ultimate compressive strength (UCS) of the cured cements were determined. Micro computed tomography showed that the cements presented average porosities of 13.5-16.9%. It was found that, while the powder particle shape and size for the experimental cements were markedly different from those of AKZ, there was no significant difference in either p or UCS for these cements. The latter was determined to be about 85 MPa for the modified cements and 84 MPa for Antibiotic Simplex. Furthermore, the UCS of all the cements exceeded the minimum level for acrylic bone cements, as stipulated by ASTM F-451.

Biocompatible Materials↗

Contrast bone cement.

The effects of adding 1.0 cc of aqueous methylene blue dye as a visual contrast agent to a standard 40 g pack of acrylic bone cement are determined. These cements are evaluated: Simplex P (Radiopaque), Zimmer Bone Cement, and Zimmer LVC Bone Cement. Seven tests were performed. Leach out is less than 2.0% and was undetectable after day 8. Biocompatibility using a rabbit model shows contrast and white cement to be equivalent. Tension, compression, and 3- and 4-point bending strengths are not significantly altered except for a slight increase in 4-point bending strength for contrast Zimmer (regular) bone cement. Dough, set, and working times are decreased by 30-150 s. The ASTM F451 intrusion standards are met for all three contrast cements. Viscosity increases more rapidly for contrast cement, but remains sufficiently low (less than 100 N-s/m2) early after mixing to allow good penetration into bone. Ease of removal and visualization of contrast cement are shown by revision of cemented femoral total hip components in synthetic and cadaver femurs and by debriding cement particles from a soft tissue background coated with blood. The use of contrast bone cement appears to be both safe and efficacious for use in initial and revision total joint replacements. Because of the decreased working times, its use is recommended only by experienced surgeons.

Animals↗

Pre-yield and post-yield shear behavior of the cement-bone interface.

Aseptic loosening of cemented total hip replacements is thought to involve mechanical failure of the cement-bone interface. However, the mechanical response of the interface, particularly the post-yield behavior, is not well understood. The purpose of this study was to determine the constitutive behavior of the cement-bone interface for loading in shear using a combination of experimental and finite element methods. A total of 55 cement-bone specimens (5 x 10 x 15-20 mm) from the proximal femur of human cadavers were loaded to failure under displacement control with use of a custom shear test jig. Finite element models of the test specimens were made and included provision for a two-parameter nonlinear interface model at the cement-bone interface. The experimental tests revealed a complicated load versus displacement response with an initial linear region and a reduction in slope until the ultimate strength (2.25+/-1.49 MPa) was reached, followed by an exponential decrease in load with increasing displacement until the entire interface debonded. Failure most often occurred at the cement-bone interface, where the cement penetrated into the bone with bone remaining in the cement in 30 specimens and with bone remaining in the cement and cement spicules remaining in the bone in 22 specimens. The adjacent bulk bone and cement did not appear to be permanently deformed. Finite element models of the test specimens revealed that failure initiated at the base of the test specimen before the peak load had been reached. The two interface parameters, interface strength (2.71+/-1.90 MPa) and interface-softening exponent (4.96+/-3.47 1/mm), could be determined directly from the experimental data and provided a good fit with the experimental structural response for a wide range of interface strengths. These results show that the cement-bone interface does not fail abruptly when the shear strength is reached but absorbs a substantial amount of energy with post-yield strain-softening behavior.

Adult↗

In vitro analysis of the cement mantle of femoral hip implants: development and validation of a CT-scan based measurement tool.

We developed, validated and assessed inter- and intraobserver reliability of a CT-scan based measurement tool to evaluate morphological characteristics of the bone-cement-stem complex of hip implants in cadaver femurs. Two different models were investigated: the stem-cavity model using a double tapered polished femoral-stem that is removed after cement curing and the plastic-replica model using a stereolithographic stem replica that is left in place during CT-scanning. Software was developed to segment and analyze connective CT-images and identify the contours of bone, cement, and stem based on their respective gray values. Volume parameters (whole specimen, cement, stem, air contents of bone and cement), concentricity parameters (distances between centroids of stem and cement, cement and bone, stem and bone), contact surfaces (bone/air and cement/bone) and bone cement mantle thickness parameters were calculated. A three-dimensional protocol was developed to evaluate the minimal mantle thickness out of the CT-plane. The average accuracy for surfaces within CT-images was 7.47 mm2 (1.80%), for bone and cement mantle thickness it was 0.51 mm (9.39%), for distances between centroids it was 0.38 mm (18.5%) and contours: 0.27 mm (2.57%). The intra- and interobserver reliability of air content in bone and cement was sub-optimal (intraclass-correlation coefficient (ICC) as low as 0.54 with an average ICC of 0.85). All other variables were reliable (ICC>0.81, average ICC: 0.96). This in vitro technique can assess characteristics of cement mantles produced by different cementing techniques, stem types or centralizers.

Arthroplasty, Replacement, Hip↗

Pre-clinical validation of a new partially cemented femoral prosthesis by synergetic use of numerical and experimental methods.

The present work reports the pre-clinical validation of an innovative partially cemented femoral prosthesis called cement-locked uncemented (CLU) prosthesis. The inventors of the device under investigation claimed that, when compared to a comparable fully cemented stem, the new stem would present various advantages. Two previous experimental studies confirmed that primary stability and stress shielding were comparable to those of cemented stems. Aim of the present study was to investigate if the remaining claims were confirmed as well. A complete finite element model of the bone-implant complex was created from CT data. The model was validated against in vitro measurements of bone surface strains as well as against primary stability measurements. The peak stresses predicted in the CLU cement mantle were not found significantly lower than those reported in other studies on fully cemented stems. However, once the cement inlet geometry is optimised and the associated stress risers are eliminated, the CLU cement mantle should be subjected to much lower stresses. The stress induced in the stems by both load cases was well below the fatigue limit of the Ti6Al4V alloy. Finite element models predicted for all load cases relative motion between cement and metal lower than 60 microm. This amplitude may be fully accommodated by elastic deformations of the cement micro-ridges. The experimental and numerical results showed the validity of the new fixation concept, although a further optimisation of the geometry of the cement pockets is needed in order to further reduce the stresses in the cement.

Alloys↗

Mechanical properties and biochemical activity of remineralizing resin-based Ca-PO4 cements.

OBJECTIVE: This study examined strength and bioactive (remineralizing) properties of a powder/liquid formulation (Cement I) and a more practical two-paste formulation (Cement II) of a fluoride-releasing resin-based Ca-PO(4) cement. METHODS: For the remineralization potential, the dissolution of calcium, total ionic phosphate and fluoride from set cement specimens were determined in buffered saline and saliva-like solution (SLS). Artificial caries lesions were produced on coronal dentin of extracted human molars. On each tooth, two defined areas were coated, one with a composite resin (calcium-free control), the other with either Cement I or II. After incubation in SLS, the mineral loss under the cement was analyzed by digitized microradiography and compared to that under the control. RESULTS: The diametral tensile strength of Cement II of approximately 30 MPa after 24 h and 23 MPa after 4 weeks was 2 to 3 times higher than that of Cement I (ANOVA, t-test, p<0.05). Calculations of the ion-activity products and Gibb's free energy from solution ion concentrations indicated a significant potential for the formation of fluor- and/or hydroxyapatite. Concurrently, both cements caused increases of 47% (Cement I) and 38% (Cement II) in the lesion mineral content over that underneath the corresponding controls. SIGNIFICANCE: These in vitro results suggest that the stronger Cement II could serve as a restoration-supporting lining material and could remineralize dentin in areas where complete removal of carious tissue is contra-indicated.

Apatites↗