Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Atrioventricular Block”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36Linked to original sources

Electrophysiologic and pathologic correlations in two cases of chronic second degree atrioventricular block with left bundle branch block.

This study concerns two cases of chronic 2 degrees atrioventricular (A-V) block with left bundle branch block (LBBB). Pathological studies included serial section of the conduction systems. Case 1 had type I 2 degrees block with LBBB. Electrophysiological studies revealed type I 2 degrees block proximal to the His bundle recording site and a prolonged H-V interval (60 msec). Pathologically there was a moderate to marked fibrosis of the approaches to the A-V node and of the A-V node, marked fibrosis of the left bundle branch, and moderate involvement of the right bundle branch. The changes proximal to the His bundle were more marked than the changes distal to this bundle. Case 2 had type II and 2:1 2 degrees A-V block with LBBB. Electrophysiologically the site of block was distal to the His bundle recording site, and there was a prolonged A-V node and severe involvement of both bundle branches. The changes distal to the His bundle were more severe than the changes proximal to the His bundle. This study reveals that the electrophysiologic data more closely approximated the pathologic findings than did surface electrocardiographic data alone. It also emphasizes that there may be multiple sites of disease in chronic 2 degrees block with bundle branch block.

Aged↗

Pacemaker implantation in a ferret (Mustela putorius furo) with third-degree atrioventricular block.

A 7.5-year-old castrated male ferret (Mustela putorius furo) was diagnosed with third-degree atrioventricular (AV) block. A monopolar epicardial pacemaker system was implanted, resulting in a regular, paced cardiac rhythm with third-degree AV block at 140 beats per minute. Over the next 2 months, the ferret developed anorexia, interstitial pneumonia, intermittent diarrhea, and hind-limb weakness and had a slow and progressive recovery. The ferret developed clinical signs of congestive heart failure 4 months after the surgery, resulting in its death 3 weeks later. Necropsy results attributed the death to cardiac failure due to extensive myocardial mineralization. To the authors' knowledge this is the first published report of surgical report of surgical pacemaker implantation in a ferret.

Animals↗

Wenckebach's periods or alternating Wenckebach's periods during 4:1 atrioventricular block?

This article deals with the tracings of a patient having episodes of atrial flutter with 4:1 atrioventricular (AV) block increasing to 8:1 AV block. This phenomenon was attributed to the coexistence of 3-level block due to transverse dissociation with 2:1 AV block in the most proximal level, or first level as well as in the second level coexisting with a Wenckebach's period in the most distal, or third level. It is suggested that perhaps the term Wenckebach's periods during progression of 4:1 AV block best describes this arrhythmia so as to maintain the term alternating Wenckebach's periods only to those occurring when 2:1 block increases to higher degrees of AV block.

Aged↗

Electrophysiologic and histologic observations of chronic atrioventricular block induced by closed-chest catheter desiccation with radiofrequency energy.

Direct-current or laser energy has been used to induce atrioventricular (AV) block, but certain complications associated with this type of energy have been reported. We have previously documented that radiofrequency (RF) energy can effectively and safely induce acute AV block in closed-chest dogs during the 4-7 days of follow-up. This study was undertaken to determine if the ablation was permanent and to define the chronic pathology and site of AV block. Complete AV block was successfully achieved in four dogs immediately after ablation with a bipolar "standard" RF output (750 kHz) delivered between the tip electrode of a standard 7F USCI catheter and an external patch electrode on the left lateral chest wall. During 2 months of follow-up, three dogs had persistent complete AV block with a stable escape rhythm; the other had persistent 2:1 AV block. Repeat His bundle recordings were performed at 2 months prior to sacrifice of the dogs. Supra-His AV block was noted in two dogs; His bundle potential could not be recorded in another two. Histologically, the damaged area was well delineated. In all animals, the AV node and, in some dogs, part of the His bundle were completely replaced by granulation tissue and/or cartilage. There was fatty infiltration and also chronic inflammatory cells around the lesions. Neither perforation, hemorrhage nor vacuolation was seen in the adjacent area. Thrombus was not present. It is concluded that RF energy can effectively achieve chronic AV block and produce well-circumscribed pathological lesions.

Animals↗

A case of cardiac sarcoidosis with advanced atrioventricular block. Failure of endomyocardial biopsy diagnosis and success in detecting.

We present a case of cardiac sarcoidosis with advanced atrioventricular (AV) block in a 45-year-old female patient. Although endomyocardial biopsy and other diagnostic findings were inconclusive, gastrocnemial muscle biopsy indicated a definitive diagnosis of sarcoidosis. Whole-body gallium-67 scintigraphy was useful to confirm the suspicion of the presence of sarcoidosis. Thereafter, magnetic resonance imaging (MRI) was successful in detecting the space-occupying lesion in the skeletal muscle, leading to a positive diagnosis of sarcoidosis. It is concluded that the presence of myocardial disease, such as cardiac sarcoidosis, should be considered when advanced AV block is encountered. Even if endomyocardial biopsy and other conventional diagnostic approaches are inconclusive, the possibility of cardiac involvement in sarcoidosis cannot be denied. This case report stresses the importance of more advanced diagnostic approaches, such as whole-body gallium scanning and MRI, in clarifying the etiology of AV block. Establishing the diagnosis of cardiac sarcoidosis is important in determining whether or not to begin effective long-term treatment with corticosteroids.

Cardiomyopathies↗

Rare association of hypertrophic cardiomyopathy and complete atrioventricular block with prompt disappearance of outflow gradient after DDD pacing.

Although arrhythmias are common in hypertrophic cardiomyopathy (HCM), complete atrioventricular (AV) block is very unusual. A 27-year-old female presented with a recent history of syncope and exercise intolerance. ECG demonstrated complete AV block. Two-dimensional Doppler echocardiography revealed HCM with a 60 mmHg left ventricular outflow tract (LVOT) gradient. A temporary transvenous ventricular pacemaker was inserted urgently, and subsequently replaced by a permanent DDD pacemaker. All symptoms were eliminated. This symptomatic improvement was associated with complete disappearance of LVOT gradient at the time of implantation. No gradient was observed during early follow-up and at 6 months after DDD pacemaker implantation.

Adult↗

Physiologic VDD versus nonphysiologic VVI pacing in canine 3rd-degree atrioventricular block.

Historically, ventricular demand, nonphysiologic (VVI) pacing has been the most commonly used modality to treat 3rd-degree atrioventricular (AV) block. The goal of this study was to determine the feasibility of using a commercial, single-lead, physiologic (VDD) pacemaker in dogs with 3rd-degree AV block. Furthermore, we hoped to characterize and identify differences in the radiographic, echocardiographic, neurohormonal, and quality of life consequences of physiologic versus nonphysiologic pacing. We evaluated 10 dogs during a 12-week crossover study. Acutely, rate-matched physiologic pacing reduced pulmonary capillary wedge pressure by 19% compared with nonphysiologic pacing. VDD pacing significantly reduced left atrial size normalized to body weight, left atrial-to-aortic root ratio, and left ventricular end-systolic dimension and increased fractional shortening, aortic Doppler velocity, cardiac output, and stroke volume compared with VVI pacing. Variable rate VDD pacing resulted in a significantly slower heart rate (HR) during echocardiography than fixed-rate (100 bpm) VVI pacing. AV synchronous pacing reduced circulating N-terminal proatrial natriuretic peptide (ANP), norepinephrine (NOR), and epinephrine (EPI) concentrations compared with asynchronous pacing. There were no significant differences in systemic blood pressure, thoracic radiographs, or owner-perceived quality of life. The median percentage of AV synchronous pacing during the VDD modality was 99.8% (range, 1.2 to 99.9%). This study confirms the potential to achieve physiologic pacing with a commercial, single-lead system in dogs. VDD pacing improved hemodynamics and neurohormonal profiles over asynchronous pacing although the long-term clinical benefits of these changes remain to be determined.

Animals↗

Complete atrioventricular block with QRS complexes of variable amplitude.

Nonrespiratory QRS amplitude variations related to PR interval length were observed in a case of complete atrioventricular (AV) block with narrow QRS complexes. This electrocardiographic pattern was studied, taking into consideration the greater deflection of the ventricular complexes (R- or S-wave) on each standard lead and by analyzing three groups of QRS (A, B, C) divided in relation to the different timing of the atrial systole. A significant variation appears in the entity of the mitral flow, as assessed by Doppler echocardiography evaluation, related to PR interval length, and a significant inverse correlation was found between QRS variability and ventricular diastolic filling.

Adolescent↗

Advanced early and late atrioventricular block in acute inferior wall myocardial infarction.

Seventy-six patients with acute inferior acute myocardial infarction (AMI) and advanced atrioventricular (AV) block are described. According to pre-established ECG criteria and time of appearance of the advanced AV block, patients were divided into two groups. The early block group consisted of 31 patients who developed advanced AV block during the hyperacute ECG stage of AMI. Advanced AV block in these patients was characterized by early appearance, short duration, third-degree type block, poor response to atropine, and increased need for pacemaker therapy. The late block group consisted of 45 patients who developed advanced AV block during subsequent ECG stages of AMI. Advanced AV block in these patients was characterized by late appearance, longer duration, second-degree type block, positive response to atropine, and diminished need for pacemaker therapy. Morbidity and mortality also differed between both groups. Patients with early block had more syncope (32% vs 2%, p less than 0.0001), more left heart failure (36 vs 7%, p less than 0.005), and more cardiogenic shock (39% vs 2%, p less than 0.001) than patients with late block. The mortality rate in the early block group was high (23%) and similar to that reported in the literature, whereas the mortality rate in the late block group was low (7%, p less than 0.05) and similar to the mortality rate reported for acute inferior AMI without advanced AV block. These data identify a subgroup of patients with acute inferior AMI and advanced AV block, which accounts for the high mortality rate reported in this group of patients.

Adult↗

Atrioventricular block progression in patients with bifascicular block assessed by repeated electrocardiography and a bradycardia-detecting pacemaker.

Syncope may be due to intermittent high-degree atrioventricular (AV) block, but a cause-relation is sometimes difficult to prove. Diagnostic methods with high predictive value proven by instruments for safe and sensitive follow-up are needed. A bradycardia-detecting pacemaker was used in patients with bifascicular block, who had been the subjects of pharmacologic stress testing of the His-Purkinje system. Thirty-seven patients were included, of whom 26 had experienced at least 1 syncopal episode of suspected bradycardia origin, and 11 had previously documented transient high-degree AV block. The electrophysiologic study included injection of disopyramide 2 mg/kg (up to 150 mg) over 5 minutes. A positive test result was defined as spontaneous or pacing-induced His-Purkinje high-degree AV block after drug or a drug-induced HV prolongation of > or = 50%. Patients were followed an average 63 months with repeated electrocardiography and a diagnostic pacemaker (n = 23). Altogether, 24 patients had a significant bradycardia diagnosed by either or both methods. The sensitivity and positive predictive values were: HV interval > or = 70 ms at baseline, 47% and 88%; a positive disopyramide test result, 75% and 80%; and HV interval > or = 70 ms or a positive disopyramide test result, 93% and 74%, respectively. Thus, the diagnostic pacemaker is a safe and sensitive tool for evaluating the information obtained at electrophysiologic study, and pharmacologic stress testing with disopyramide has an informative value in patients with bifascicular block and syncope when results at baseline are inconclusive.

Aged↗