Velocity encoding using ghost artifacts.

Motion artifacts represent a significant limitation of MRI, and an ideal solution to that problem has proved elusive. However, in this paper, motion artifacts are not considered as the usual enemy and are not suppressed; on the contrary, they are deliberately created to encode flow information. In MRI, velocity is encoded readily into the phase of a pixel. However, if the pixel contains overlapping signals, the phase of one of these signals now has consequences on both the magnitude and phase of the resulting pixel. It is shown here that an overlap of information may be used to encode velocity both in the phase and in the magnitude of an image, making the velocity-encoding process faster. The overlap of information is obtained by superposing ghosting artifacts of different orders and information is retrieved about complex intensity and velocity in two dimensions using the equivalent of two images instead of the usual three images. The price to pay to do so is some loss of simplicity in the equations involved, an increase in reconstruction computing time requirements, and a factor of 4 decrease in signal-to-noise ratio in the velocity measurements.

Artifacts↗

Characterization of and correction for artifacts in linogram MRI.

Chemical shift differences, field inhomogeneity, and gradient nonlinearity result in artifacts in magnetic resonance imaging. Three artifacts are characterized for linogram imaging and it is shown that, based on computer simulations and theory, linogram MRI behaves similarly to 2DFT. A correction technique similar to a scheme for 2DFT imaging based on the Dixon technique and coordinate transform methods is proposed. The algorithm is applied to correct for field inhomogeneity and gradient nonlinearity-induced artifacts in both simulations and images of a clinical phantom. The results show good correlation with the theory. It is concluded that linogram imaging offers certain attractive features of both 2DFT and PR imaging techniques, and is a potentially viable alternative to PR imaging in the presence of field inhomogeneity.

Adipose Tissue↗

Characterization of and correction for eddy current artifacts in echo planar diffusion imaging.

Magnetic resonance diffusion imaging is potentially an important tool for the noninvasive characterization of normal and pathological tissue. The technique, however, is prone to a number of artifacts that can severely affect its ability to provide clinically useful information. In this study, the problem of eddy current-induced geometric distortions that occur in diffusion images acquired with echo planar sequences was addressed. These geometric distortions produce artifacts in computed maps of diffusion parameters and are caused by misalignments in the individual diffusion-weighted images that comprise the diffusion data set. A new approach is presented to characterize and calibrate the eddy current effects, enabling the eddy current distortions to be corrected in sets of interleaved (or snapshot) echo planar diffusion images. Correction is achieved by acquiring one-dimensional field maps in the read and phase encode direction for each slice and each diffusion step. The method is then demonstrated through the correction of distortions in diffusion images of the human brain. It is shown that by using the eddy current correction scheme outlined, the eddy current-induced artifacts in the diffusion-weighted images are almost completely eliminated. In addition, there is a significant improvement in the quality of the resulting diffusion tensor maps.

Artifacts↗

Artifacts induced by concomitant magnetic field in fast spin-echo imaging.

It has been observed that fast spin-echo (FSE) images with a large field of view (>40 cm) in certain directions exhibit unusual ghosting artifacts that cannot be eliminated with existing ghost removal methods. These artifacts have been related to a higher-order magnetic field perturbation (known as the concomitant field, or Maxwell field) concomitant to the linear imaging gradient, in accordance with the Maxwell equations V z B = 0 and V x B approximately 0. Several methods have been developed to eliminate or minimize the effects of the concomitant magnetic field by redesigning the FSE pulse sequences. In the slice-selection direction, the gradient waveforms are made symmetrical about the refocusing RF pulses wherever possible. Surrounding the first refocusing pulse, such symmetry cannot be achieved due to the slice-refocusing gradient, which is often combined with the left crusher. In this case, it is shown how crusher gradients can be reshaped to nullify the phase due to the concomitant field. In the phase-encoding direction, the gradient amplitude is reduced and its duration is prolonged. Artifacts due to the readout gradient are eliminated by reshaping the prephasing lobe, while keeping its area fixed. In all the three directions, the gradient waveforms are adjusted so that they have minimal overlap. Selected methods have been implemented on a clinical scanner, and typically reduce the ghost intensities in phantom and human images by a factor of 3.

Artifacts↗

Artifact reduction in undersampled projection reconstruction MRI of the peripheral vessels using selective excitation.

The projection reconstruction (PR)-HyperTRICKS (time resolved imaging of contrast kinetics) acquisition integrates the benefits of through-plane Cartesian slice encoding and in-plane undersampled PR. It provides high spatial resolution both in-plane (about 1 mm(2)) and through-plane (1-2 mm), as well as relatively high temporal resolution (about 0.25 frames per second). However, undersampling artifacts that originate from anatomy superior or inferior to a coronal imaging FOV may severely degrade the image quality. In coronal MRA acquisitions, the slice coverage is limited in order to achieve high temporal resolution. In this report we describe an artifact reduction method that uses selective excitation in PR-HyperTRICKS. This technique significantly reduces undersampling streak artifacts while it increases the slice coverage.

Artifacts↗

UNFOLD-SENSE: a parallel MRI method with self-calibration and artifact suppression.

This work aims at improving the performance of parallel imaging by using it with our "unaliasing by Fourier-encoding the overlaps in the temporal dimension" (UNFOLD) temporal strategy. A self-calibration method called "self, hybrid referencing with UNFOLD and GRAPPA" (SHRUG) is presented. SHRUG combines the UNFOLD-based sensitivity mapping strategy introduced in the TSENSE method by Kellman et al. (5), with the strategy introduced in the GRAPPA method by Griswold et al. (10). SHRUG merges the two approaches to alleviate their respective limitations, and provides fast self-calibration at any given acceleration factor. UNFOLD-SENSE further includes an UNFOLD artifact suppression scheme to significantly suppress artifacts and amplified noise produced by parallel imaging. This suppression scheme, which was published previously (4), is related to another method that was presented independently as part of TSENSE. While the two are equivalent at accelerations < or = 2.0, the present approach is shown here to be significantly superior at accelerations > 2.0, with up to double the artifact suppression at high accelerations. Furthermore, a slight modification of Cartesian SENSE is introduced, which allows departures from purely Cartesian sampling grids. This technique, termed variable-density SENSE (vdSENSE), allows the variable-density data required by SHRUG to be reconstructed with the simplicity and fast processing of Cartesian SENSE. UNFOLD-SENSE is given by the combination of SHRUG for sensitivity mapping, vdSENSE for reconstruction, and UNFOLD for artifact/amplified noise suppression. The method was implemented, with online reconstruction, on both an SSFP and a myocardium-perfusion sequence. The results from six patients scanned with UNFOLD-SENSE are presented.

Artifacts↗

Reduction of artifacts by optimization of the sensitivity map in sensitivity-encoded spectroscopic imaging.

Sensitivity-encoded spectroscopic imaging (SENSE-SI) reduces scanning time by using multiple coils for parallel signal acquisition. Significant artifacts could be induced by SENSE-SI, mainly due to the low-resolution nature of spectroscopic imaging. The present study introduces a novel method to reduce the artifacts. High-resolution sensitivity maps are used in low-resolution SENSE reconstruction. An intermediate unaliased image is obtained after SENSE reconstruction. Based on the intermediate image, the sensitivity maps are optimized and then the SENSE reconstruction is performed again. The final unaliased image has significantly reduced artifacts.

Algorithms↗

Real-time display of artifact-free electroencephalography during functional magnetic resonance imaging and magnetic resonance spectroscopy in an animal model of epilepsy.

Simultaneous recording of electroencephalogram (EEG) and functional MRI (fMRI) or MR spectroscopy (MRS) can provide further insight into our understanding of the underlying mechanisms of neurologic disorders. Current technology for simultaneous EEG and MRI recording is limited by extensive postacquisition processing of the data. Real-time display of artifact-free EEG recording during fMRI/MRS studies is essential in studies that involve epilepsy to ensure that they address specific EEG features such as epileptic spikes or seizures. By optimizing the EEG recording equipment to maximize the common mode rejection ratio of its amplifiers, a unique EEG system was designed and tested that allowed real-time display of the artifact-free EEG during fMRI/MRS in an animal model of epilepsy. Spike recordings were optimized by suppression of the background EEG activity using fast-acting and easily controlled inhalational anesthesia. Artifact suppression efficiency of 70-100% was achieved following direct subtraction of referentially recorded filtered EEG tracings from active electrodes, which were located in close proximity to each other (over homologous occipital cortices) and a reference electrode. Two independent postacquisition processing tools, independent component analysis and direct subtraction of unfiltered digital EEG data in MATLAB, were used to verify the accuracy of real-time EEG display.

Algorithms↗

Correction of through-plane deformation artifacts in stimulated echo acquisition mode cardiac imaging.

Attempts to use a stimulated echo acquisition mode (STEAM) in cardiac imaging are impeded by imaging artifacts that result in signal attenuation and nulling of the cardiac tissue. In this work, we present a method to reduce this artifact by acquiring two sets of stimulated echo images with two different demodulations. The resulting two images are combined to recover the signal loss and weighted to compensate for possible deformation-dependent intensity variation. Numerical simulations were used to validate the theory. Also, the proposed correction method was applied to in vivo imaging of normal volunteers (n = 6) and animal models with induced infarction (n = 3). The results show the ability of the method to recover the lost myocardial signal and generate artifact-free black-blood cardiac images.

Animals↗

Correcting for artifacts in complex aqueous solutions when using the pH-sensitive dye 2',7'-bis-(2-carboxyethyl)- 5-(and -6)carboxyfluorescein.

The pH-sensitive fluorescent indicator dye 2', 7'-bis-(2-carboxyethyl)-5-(and -6)carboxyfluorescein (BCECF) is routinely used to measure intracellular pH within cells. Surprisingly, no studies have been performed to see if various solution parameters modulate the fluorescence intensity of BCECF even though viscosity artifacts have been reported for particular Ca2+ selective dyes. In this report we demonstrate that even minor increases in the concentration of a number of different agents significantly decrease the excitation fluorescence intensity at two wavelengths routinely used to determine solution pH. Solution viscosity was varied using a number of different agents including glycerol, sucrose, polyethylene glycol, polyvinylpyrrolidone, and methylcellulose. In general, there was a detectable and significant decrease in the maximum fluorescence excitation ratio as the viscosity was increased, although the effect was more dramatic with Newtonian solutions than with non-Newtonian solutions. This same general effect was seen at pH 6.5, 7.0, and 7.3, a range of pH levels where BCECF is found to be particularly sensitive. To correct for these artifactually low values we used different combinations of excitation wavelengths to determine which could be used to accurately measure pH while minimizing the artifact. Choosing excitation wavelengths so that excitation ratios were collected at 470 and 435 nm allowed a significant signal to quantitatively measure pH while the artifact was nearly abolished.

Artifacts↗

Solvent magnetization artifacts in high-field NMR studies of macromolecular hydration.

With the use of high magnetic fields and improved quality factor ratings of the probeheads in modern NMR spectrometers, radiation damping becomes more and more important. In addition, the demagnetizing field effect from protonated solvents gains significance with the increase of the magnetic field strength. During a typical NMR pulse sequence the magnetic fields caused by these effects become time-dependent, which makes the system nonlinear and may, for example, measurably influence the precession frequencies of all nuclei in the sample. Since radiation damping can affect signals that are several kilohertz away from the solvent resonance, the amplitude, phase, and frequency of the desired signals can be disturbed so as to give rise to spectral artifacts. In particular when difference methods are used to obtain the final spectrum, the data sets may be severely deteriorated by such artifacts. This paper investigates effects from the demagnetizing field and from radiation damping with a selection of pulse sequences in use for studies of macromolecular hydration, and strategies are described for the detection and elimination of the ensuing artifacts.

Artifacts↗

Clean TROSY: compensation for relaxation-induced artifacts.

TROSY pulse sequences for recording, e.g., (1)H-(15)N chemical shift correlation spectra of proteins are designed to select only one of four two-dimensional multiplet components. However, all of the variants published so far are prone to relaxation-induced artifacts at the positions of two of the other multiplet components. This article introduces modifications to the two spin-state-selective coherence transfer building blocks of the TROSY mixing sequence resulting in a clean TROSY spectrum with the artifacts largely suppressed. It works by having the new mixing sequence generate peaks of opposite phase at the positions of the relaxation artifacts. The clean TROSY pulse sequence is marginally shorter than the original one and contains the same pulses. Experimental demonstration is presented for the (15)N-labeled proteins RAP 17-97 (N-terminal domain of alpha(2)-macroglobulin receptor associated protein) and EQT, equinatoxin II, from the Mediterranean anemone Actinia equina.

Animals↗

Clinical functional image analysis: artifact detection and reduction.

Rapid improvements in functional magnetic resonance neuroimaging technology have resulted in impressive advances in our understanding of structure/function relationships in the human brain. The application of this new technology to the understanding of human brain disease is currently limited by difficulties in extracting task-related signal change from signal intensity time series that have been contaminated by artifacts arising from various intrinsic and extrinsic sources. Effects induced by interscan head motion are a major source of these artifacts. The correction of these artifacts by registration of pairs of reconstructed images has been a focus of research for the past few years and there are now a number of effective means to compensate for this source of noise. This paper discusses issues concerning the prevention and correction of interscan head motion as well as other sources of error variation in fMRI time series.

Artifacts↗

Echo time dependence of BOLD contrast and susceptibility artifacts.

Echo-planar imaging with gradient echo allows whole-brain images to be rapidly acquired. However, its main limitation is that magnetic field inhomogeneities in regions of the brain close to bone and air-filled sinuses result in reduced signal-to-noise ratio and signal loss. In particular this is a problem for imaging the temporal lobes, and can therefore affect the results of some language-related studies. Decreasing the echo time (TE) increases the signal-to-noise ratio and reduces the amount of signal loss in susceptible regions. In this study we investigate the TE dependence of BOLD (blood oxygenation level-dependent) contrast and, in particular, how it is influenced in regions with susceptibility artifacts. We use a dual echo-time sequence to compare brain activations measured with two different TEs, TE = 40 ms and TE = 27 ms. The paradigm involves comparing famous faces to scrambled faces, a low-level control condition. It was chosen because famous faces have been repeatedly shown to activate the fusiform gyri and anterior temporal lobes in both PET and fMRI. Our results show that it is possible to detect robust activations at a lower TE in brain regions not affected by susceptibility artifacts (i.e., fusiform gyri), allowing for faster scanning times. However, although the amount of signal loss is reduced at the lower TE, this does not appear to be sufficient to recover the BOLD signal in regions affected by susceptibility artifacts (i.e., anterior temporal lobes).

Adult↗

Artifacts in magnetic resonance imaging of the spine after surgery with or without implant.

Magnetic resonance (MR) imaging is often disturbed after spine surgical procedures with or without an implant. Artifacts are induced by ferromagnetic or nonferromagnetic implants and devices and by small metallic particles left by surgical instruments. All metallic artifacts can affect the quality and usefulness of postoperative spine MR examinations. The physical effects caused by the introduction of metal or other conductive materials into a magnetic field and their consequences are presented. The application to postoperative spine MR examinations and solutions to reduce artifacts are discussed.

Artifacts↗

Magneto-encephalogram artifacts caused by electro-encephalogram electrodes.

The electro-encephalogram (EEG) and magneto-encephalogram (MEG) are often measured simultaneously. By Faraday's law of induction, the changing magnetic field of the MEG can induce eddy currents in the EEG electrodes. These eddy currents produce their own magnetic field that adds to that produced by current sources in the brain, resulting in an artifact in the MEG recording. It is shown that, under typical conditions, this artifact is less than 1%, but, during measurements of high temporal frequency and high spatial resolution, the artifact can be as large as 3%.

Artifacts↗

Real-time ocular artifact suppression using recurrent neural network for electro-encephalogram based brain-computer interface.

The paper presents an adaptive noise canceller (ANC) filter using an artificial neural network for real-time removal of electro-oculogram (EOG) interference from electro-encephalogram (EEG) signals. Conventional ANC filters are based on linear models of interference. Such linear models provide poorer prediction for biomedical signals. In this work, a recurrent neural network was employed for modelling the interference signals. The eye movement and eye blink artifacts were recorded by the placing of an electrode on the forehead above the left eye and an electrode on the left temple. The reference signal was then generated by the data collected from the forehead electrode being added to data recorded from the temple electrode. The reference signal was also contaminated by the EEG. To reduce the EEG interference, the reference signal was first low-pass filtered by a moving averaged filter and then applied to the ANC. Matlab Simulink was used for real-time data acquisition, filtering and ocular artifact suppression. Simulation results show the validity and effectiveness of the technique with different signal-to-noise ratios (SNRs) of the primary signal. On average, a significant improvement in SNR up to 27 dB was achieved with the recurrent neural network. The results from real data demonstrate that the proposed scheme removes ocular artifacts from contaminated EEG signals and is suitable for real-time and short-time EEG recordings.

Artifacts↗

Suppression of the cardiac electric field artifact from the heart action evoked potential.

The study of heart action-related brain potentials is strongly disrupted by the presence of an inherent cardiac electric artifact. The hypothesis is presented that most of the electric current coupled to the cardiac field surrounds the skull and flows through the scalp tissue without crossing the cranial cavity. This pseudo two-dimensional conduction model contrasts with the volumetric conduction of the brain electrical activity, and this property is exploited to cancel the cardiac electric artifact. QRS loop vector-cardiographic projections on saggital planes were recorded in 11 healthy subjects in the head and neck areas. Comparative analysis of the projection eccentricities, estimated by the correlation coefficients of the paired data on each area, supported the hypothesis and allowed the handling of the cardiac electric field at the scalp as if enclosed in a two-dimensional wrapped space. This approach permitted the combination of different heart action-related brain potentials recorded at different electrode positions to cancel the cardiac electric artifact. The cancellation method, applied to the subjects' EEG data, yielded a slow cortical potential with a negligible cardiac electric residue and an amplitude of about 1.5-2 microV, with a maximum around 150 ms and a minimum at 400 ms post-R wave.

Adult↗