Intraprostatic temperature monitoring during transurethral microwave thermotherapy: status and future developments.

Transurethral microwave thermotherapy is being applied as a minimally invasive treatment for alleviating the symptoms of urinary outlet obstruction associated with benign prostatic hyperplasia. Treatment progress has traditionally been guided in its effective power by rectally and urethrally measured temperatures, whereas intraprostatic temperatures would be preferred for feedback purposes. A critical evaluation is presented of intraprostatic thermometry techniques that have been suggested, the techniques currently being used and investigated, and the problems that remain to be solved. Techniques for noninvasive temperature measurement and detecting tissue response during thermal therapy are discussed in more detail. Results presented in the literature have shown magnetic resonance imaging and ultrasonic imaging to be adequate thermometry modalities. For treatment monitoring of transurethral microwave thermotherapy, ultrasonic imaging is especially promising. Future research will indicate whether the promise evolves into a sound clinical technique.

Body Temperature↗

Noninvasive determination of core temperature during anesthesia.

A noninvasive, zero heat flux method of determining core (intracardiac blood) temperature was studied in ten anesthetized patients having whole body hyperthermia for the treatment of cancer. True intracardiac blood temperature was determined by a calibrated pulmonary artery thermistor. Accuracy, precision, and responsivity for the noninvasive system were comparable to conventional esophageal thermometry in reflecting intracardiac blood temperatures. This method of contact thermometry is convenient and independent of environmental influence, and it rapidly reflects the small changes in arterial blood temperature which evoke vasomotor responses.

Anesthesia, General↗

Ocular surface temperature: a review.

PURPOSE: To review the evolution in ocular temperature measurement during the last century and examine the advantages and applications of the latest noncontact techniques. The characteristics and source of ocular surface temperature are also discussed. METHODS: The literature was reviewed with regard to progress in human thermometry techniques, the parallel development in ocular temperature measurement, the current use of infrared imaging, and the applications of ocular thermography. RESULTS: It is widely acknowledged that the ability to measure ocular temperature accurately will increase the understanding of ocular physiology. There is a characteristic thermal profile across the anterior eye, in which the central area appears coolest. Ocular surface temperature is affected by many factors, including inflammation. In thermometry of the human eye, contact techniques have largely been superseded by infrared imaging, providing a noninvasive and potentially more accurate method of temperature measurement. Ocular thermography requires high resolution and frame rate: features found in the latest generation of cameras. Applications have included dry eye, contact lens wear, corneal sensitivity, and refractive surgery. CONCLUSIONS: Interest in the temperature of the eye spans almost 130 years. It has been an area of research largely driven by prevailing technology. Current instrumentation offers the potential to measure ocular surface temperature with more accuracy, resolution, and speed than previously possible. The use of dynamic ocular thermography offers great opportunities for monitoring the temperature of the anterior eye.

Body Temperature↗

Comparison of temporal artery thermometer to standard temperature measurements in pediatric intensive care unit patients.

OBJECTIVES: To determine the accuracy of noninvasive infrared temporal artery thermometry compared with rectal, axillary, and pulmonary artery catheter measurements in pediatric intensive care patients, and to determine whether temporal artery temperatures are affected by circulatory shock or by vasopressor use. We hypothesized that temporal artery temperatures do not differ from axillary and rectal temperatures in critically ill children, but temporal artery accuracy is decreased by shock or vasopressor use. DESIGN: Observational study, unblinded. SETTING: Pediatric intensive care unit of a quarternary referral children's hospital. PATIENTS: Seventy-five temperature comparison pairs were obtained in 44 pediatric intensive care unit patients. INTERVENTIONS: Temperature measurements were made using a temporal artery thermometer with simultaneously obtained rectal, axillary, and, when available, pulmonary artery catheter measurements. MEASUREMENTS AND MAIN RESULTS: Mean bias was calculated between comparison pairs using each temperature method. Bland-Altman analysis demonstrated wide variability between methods. No significant differences in mean bias were seen between method pairs for all temperatures, but bias was significantly less in pulmonary artery catheter-rectal pairs compared with other method pairs. In febrile (> 38 degrees C) patients, bias in rectal-temporal artery and rectal-axillary was significantly greater than in temporal artery-axillary pairs (p < .001). Mean bias in pulmonary artery catheter-rectal pairs was also significantly smaller than in other pairs for all patients (p = .008) and febrile patients (p = .049). Presence of shock or vasopressor use did not significantly increase bias in any comparison pair. Sensitivity and specificity of both temporal artery and axillary for diagnosing fever were similar and improved with fever definition at temperatures > 38.5 degrees C. CONCLUSIONS: Temporal artery and axillary temperature measurements showed variability to rectal temperatures but had marked variability in febrile children. Neither was sufficiently accurate to recommend replacing rectal or other invasive methods. As temporal artery and axillary provide similar accuracy, temporal artery thermometers may serve as a suitable alternative for patients in whom invasive thermometry is contraindicated.

Axilla↗

Detecting fever in young infants: reliability of perceived, pacifier, and temporal artery temperatures in infants younger than 3 months of age.

OBJECTIVES: Fever in young infants frequently triggers a laboratory evaluation because of the increased likelihood of serious bacterial infections. Reported fever by methods other than rectal thermometry is of concern. This study evaluates the validity of perceived, pacifier, and temporal artery (TA) temperatures. METHODS: A convenience sample of 200 babies younger than 3 months of age presenting to an emergency department was evaluated for parental perception of fever and with TA, pacifier, and rectal temperatures. RESULTS: The sensitivity and specificity of perceived and TA detection of fever were similar at 91 and 79, and 83 and 86, respectively. Febrile pacifier readings had a sensitivity of 99, but a specificity of only 46. CONCLUSIONS: Rectal thermometry must remain the standard for infants younger than 3 months of age.

Caregivers↗

Temperature measurement: comparison of non-invasive methods used in adult critical care.

AIMS AND OBJECTIVES: To assess accuracy and reliability of two non-invasive methods, the chemical (Tempa.DOT) and tympanic thermometer (Genius First Temp M3000A), against the gold standard pulmonary artery catheter, and to determine the clinical significance of any temperature discrepancy using an expert panel. BACKGROUND: There is continued debate surrounding the use of tympanic thermometry in clinical practice. DESIGN: Prospective study. METHODS: A total of 160 temperature sets were obtained from 25 adult intensive care patients over a 6-month period. RESULTS: About 75.2% (n = 115) of chemical and 50.9% (n = 78) of tympanic readings were within a +/-0.0-0.4 degrees C range of the pulmonary artery catheter. Both the chemical and tympanic thermometers were significantly correlated with temperatures derived from the pulmonary artery catheter (r = 0.81, P < 0.0001 and r = 0.59, P < 0.0001) and limits of agreement were -0.5-0.9 degrees C and -1.2-1.2 degrees C respectively. The chemical thermometer was associated with a mean temperature difference of 0.2 degrees C, which increased 0.4 degrees C when used in conjunction with a warming blanket. With regard to clinical significance 15.3% (n = 26) of chemical and 21.1% (n = 35) of tympanic readings might have resulted in patients receiving delayed interventions. Conversely 28.8% (n = 44) of chemical and 37.8% (n = 58) of tympanic readings might have resulted in patients receiving unnecessary interventions. CONCLUSIONS: The chemical thermometer was more accurate, reliable and associated with fewer clinically significant temperature differences compared with the tympanic thermometer. However, compared with the pulmonary artery catheter both methods were associated with erroneous readings. In the light of these findings and previous research evidence, it is becoming increasingly difficult to defend the continued use of tympanic thermometry in clinical practice. However, as chemical thermometers are not without their limitations, further research needs to be undertaken to evaluate the accuracy and reliability of other non-invasive methods. RELEVANCE TO CLINICAL PRACTICE: Chemical and tympanic thermometers are used in both adults and children in a wide variety of settings ranging from community to intensive care. As such these findings have significant implications for patients, users and budget holders.

Adult↗

Can training improve the results with infrared tympanic thermometers?

BACKGROUND: Infrared tympanic thermometry (ITT) is a method for body temperature measurement. Correct measuring technique is said to be important to achieve good results with this method. The objective of this study was to investigate the accuracy and effect of training in the use of infrared tympanic thermometry (ITT) on the measurement results. METHOD: Nurses trained in the use of ITT, and nurses not trained performed measurement sequences on 65 patients: one rectal and two ITT measurements in each sequence. RESULTS: Mean rectal temperatures were significantly (P < 0.01) higher than with ITT (0.44 +/- 0.42 (SD) degree C for trained, 0.56 +/- 0.4 (SD) degree C for untrained). Coefficient of repeatability for ITT measurements was +/- 0.54 degree C for trained nurses, and +/- 0.48 degree C for untrained. With ITT temperatures adjusted upwards of 0.5 degree C, the sensitivity of ITT for detecting fever as defined by rectal measurements would be 70% for trained, and 54% for untrained nurses. Repeatability and sensitivity for trained and untrained nurses were not significantly (P > 0.05) different. CONCLUSION: Training had little effect on the accuracy of the measurements. According to our results, ITT is often unreliable and should be used with caution.

Adult↗

Discretizing large traceable vessels and using DE-MRI perfusion maps yields numerical temperature contours that match the MR noninvasive measurements.

The success of hyperthermia treatments is dependent on thermal dose distribution. However, the three-dimensional temperature distribution remains largely unknown. Without this knowledge, the relationship between thermal dose and outcome is noisy, and therapy cannot be optimized. Accurate computations of thermal distribution can contribute to an optimized therapy. The hyperthermia modeling group in the Department of Radiotherapy, University Medical Center Utrecht devised a Discrete Vasculature [Kotte et al., Phys. Med. Biol. 41, 865-884 (1996)] model that accounts for the presence of vessel trees in the computational domain. The vessel tree geometry is tracked using magnetic resonance (MR) angiograms to a minimum diameter between 0.6 and 1 mm. However, smaller vessels (0.2-0.6 mm) are known to account for significant heat transfer. The hyperthermia group at Duke University Medical Center has proposed using perfusion maps derived from dynamic-enhanced magnetic resonance imaging to account for the tissue perfusion heterogeneity [Craciunescu et al., Int. J. Hyperthermia 17, 221-239 (2001)]. In addition, techniques for noninvasive temperature measurements have been devised to measure temperatures in vivo [Samulski et al., Int. J. Hypertherminal, 819-829 (1992)]. In this work, a patient with high-grade sarcoma has been retrospectively modeled to determine the temperature distribution achieved during a hyperthermia treatment. Available for this model were MR depicted geometry, angiograms, perfusion maps, as necessary for accurate thermal modeling, as well as MR thermometry data for validation purposes. The vasculature assembly through modifiable potential program [Van Leeuwen et al., IEEE Trans. Biomed. Eng. 45, 596-604 (1998)] was used in order to incorporate the traceable large vessels. Temperature simulations were made using different approaches to describe perfusion. The simulated cases were the bioheat equation with constant perfusion rates per tissue type, perfusion maps alone, tracked vessel tree and perfusion maps, and generated vessel tree. The results were compared with MR thermometry data for a single patient data set, concluding that a combination between large traceable vessels and perfusion map yields the best results for this particular patient. The technique has to be repeated on several patients, first with the same type of malignancy, and after that, on patients having malignancies at other different sites.

Algorithms↗

64-element intraluminal ultrasound cylindrical phased array for transesophageal thermal ablation under fast MR temperature mapping: an ex vivo study.

This work was undertaken to investigate the feasibility of using a cylindrical phased array for transoesophaeal thermal ablation under magnetic resonance (MR) imaging guidance. Sixty-four transducers (0.45 mm wide by 15 mm tall), operating at 4.6 MHz, were spread around the periphery of a 10.6-mm-diam cylinder. The head of the applicator was covered with a 65-microm thick latex balloon attached using watertight seals. This envelope was inflated with degassed water to provide acoustic coupling between the transducer and the tissues. The underlying operating principle of this applicator is to rotate a plane ultrasound beam electronically. For this purpose, eight adjacent transducers were excited with appropriate delay times so as to generate a plane wave. The exposure direction was changed by exciting a different set of eight elements. Ex vivo experiments conducted on 47 samples of pig liver under MR temperature monitoring demonstrated the ability of this applicator to generate cylindrical or sector-based coagulation necroses at depths up to 19 mm with excellent angular precision by applying 20 W/cm2. MR thermometry was performed in "real-time" with segmented echo-planar imaging gradient echo sequences. The temporal resolution was approximately 3 s/ image. The average value for the temperature baseline in liver tissue close to the applicator was 0.3 degrees C (+/- 0.6 degrees C). The thermal dose delivered in tissues was computed on-line during temperature imaging. Excellent MR compatibility was demonstrated, all MR acquisitions were performed without susceptibility artifacts or radio-frequency interferences with the ultrasound device. Thermal lesions identified on post-treatment follow up showed good correlation with online MR thermometry data. The individual differences between measurements performed visually and using MRI thermal dose maps were about 11% of volume. This study demonstrated the feasibility of thermal ablation using a phased array intraluminal ultrasound applicator and on-line MR monitoring.

Equipment Design↗

Thermal dosimetry of a focused ultrasound beam in vivo by magnetic resonance imaging.

Magnetic resonance imaging (MRI) thermometry has been utilized for in vivo evaluation of thermal exposure induced by a focused ultrasound beam. A simulation study of the focused ultrasound beam was conducted to select imaging parameters for reducing the error due to the spatial and temporal averaging of MRI. Temperature imaging based on the proton resonance frequency shift was utilized to obtain the temperature distribution during sonication in the skeletal muscle of eight rabbits. MRI-derived temperature information was then used to calculate the thermal dose distribution induced by the sonication and to estimate the coagulated tissue volume. The tissue changes were also evaluated directly by taking the T2-weighted and the contrast agent enhanced T1-weighted MR images. Errors in the temperature and thermal dose measurements were found to be minimal using the following parameters: slice thickness = 3 mm, voxel dimension = 0.6 mm, and scan time per image = 3.4 s. The estimated dimensions of the coagulated tissue volume were in good agreement with the tissue damages seen on the contrast agent enhanced T1-weighted images. The tissue damage seen on the histology was closely matched to the ones seen on the T2-weighted images. This study showed that MRI thermometry has significant potential for both monitoring the thermal exposure and evaluating the tissue damage. This would allow real-time control of the sonication parameters to optimize clinical treatments.

Animals↗

Neonatal hypothermia detection by ThermoSpot in Indian urban slum dwellings.

OBJECTIVE: To look at the performance of ThermoSpot liquid crystal thermometry in detecting neonatal hypothermia. DESIGN: A comparison was made between skin temperatures taken by ThermoSpot and axillary temperatures taken by digital electric thermometry. Non-medically trained local volunteers performed daily paired recordings on infants on days 1, 2, 3, 4, 5, 6, and 7 of life. SETTING: This is a non-hospital based study set in the homes of neonates in an underprivileged urban slum community in the developing world. SUBJECTS INCLUSION CRITERIA: babies born at home. EXCLUSION CRITERIA: hospital admission; parental refusal. INTERVENTIONS: The ThermoSpot was stuck to the neonate's abdomen over the liver area on day 1 and removed on day 7. MAIN OUTCOME MEASURES: Fixed test properties of ThermoSpot. RESULTS: Over 180 paired observations, the fixed test properties of ThermoSpot in the detection of hypothermia were: sensitivity 88%; specificity 97%; positive likelihood ratio 29; negative likelihood ratio 0.13. CONCLUSIONS: ThermoSpot performed well when used by non-medically trained volunteers for the detection of neonatal hypothermia in the homes of an urban slum community.

Axilla↗

Heat-activated liposomal MR contrast agent: initial in vivo results in rabbit liver and kidney.

PURPOSE: To evaluate by using in vivo magnetic resonance (MR) imaging the functionality of a liposomal paramagnetic contrast agent with T1 relaxivity that rapidly and markedly increases at temperatures above the gel-to-liquid crystalline phase transition temperature (T(c)) of the liposome membrane. MATERIALS AND METHODS: Liposomal gadolinium diethylenetriaminepentaacetic acid bis(methylamide) was injected intravenously at a dose of 0.4 or 1.2 mL (containing 10 or 30 micromol of gadolinium, respectively) per kilogram of body weight shortly before the application of focused ultrasound in liver (seven rabbits) or kidney (three rabbits). VX2 tumors had been implanted in liver in four of the rabbits. Eighteen locations in liver (13 in normal tissue, five in tumor) and 12 locations in kidney were sonicated. MR thermometry was performed during sonications. Signal intensity enhancement was evaluated on T1-weighted images acquired after the tissue cooled, and enhanced zones were compared with isotherms at T(c) of the liposome membrane (approximately 57 degrees C) by using Bland-Altman analysis. In liver, enhanced zones also were compared with areas of histologically verified thermal damage. The threshold temperature of enhancement at T1-weighted imaging was verified by monitoring the signal intensity increase after 10 sonications at varied powers in two locations in normal liver tissue. RESULTS: Persistent enhancement was observed on T1-weighted images at all sonicated liver locations. In liver, enhanced zones on T1-weighted images were contiguous both with 57 degrees C isotherms (25 measurements; mean difference +/- SD, 0.4 mm +/- 1.2) and with histologically verified areas of necrosis (seven measurements; mean difference +/- SD, 0.1 mm +/- 0.9). The threshold temperature of enhancement at T1-weighted imaging in normal liver was 53 degrees -57 degrees C. In kidney, enhanced zones on T1-weighted images did not match the isotherms. CONCLUSION: The liposomal contrast agent was effective at in vivo MR thermometry in liver but not in kidney.

Animals↗

Microbubble contrast agent with focused ultrasound to create brain lesions at low power levels: MR imaging and histologic study in rabbits.

PURPOSE: To evaluate magnetic resonance (MR) imaging-based thermometry for predicting the onset and spatial extent of lesions produced by focused ultrasound combined with a microbubble contrast agent (Optison; GE Healthcare, Milwaukee, Wis) and to compare the resulting induced temperature increase and threshold for damage with those in studies performed without the agent. MATERIALS AND METHODS: The experiments were approved by the animal care committee. Fifty-three locations in the brains of 15 rabbits were sonicated with various exposure parameters by using a 1.5-MHz focused ultrasound transducer. MR imaging was used to map the temperature rise and, along with light microscopy, to examine the lesions. Diameters of isotherms created from thermometry were compared with the resulting lesions by using Bland-Altman analysis and linear regression. The minimum acoustic power necessary for lesion creation was determined, and the apparent temperature threshold for damage was calculated with probit analysis. These thresholds were compared with prior work performed without the contrast agent. The heating induced with the microbubbles was compared with that in sonications performed without them by using a t test. RESULTS: The MR imaging-mapped temperature distributions matched the shape of the lesions. The diameters of isotherms correlated well with diameters measured at contrast material-enhanced MR imaging (mean difference between measurements, 0.0 mm +/- 0.5; R = 0.93). The temperature increase with microbubbles was statistically larger (P < .01) than for sonications performed without microbubbles. In some locations (mostly continuous wave exposures), damage was observed along the ultrasound beam path. The time-averaged acoustic power damage threshold was reduced by 91% for 10-second exposures when compared with earlier studies performed without microbubbles. The probability of producing lesions was 50% at a temperature increase of 5.9 degrees C, 5.5 degrees C lower than was observed earlier without the agent. CONCLUSION: MR imaging-based temperature measurements appeared to correlate with focused ultrasound-induced lesions in the brain when microbubbles were present, even though the temperature appeared to be below the threshold for thermal damage.

Animals↗

Recurrent nasopharyngeal tumors: preliminary clinical results with interventional MR imaging--controlled laser-induced thermotherapy.

PURPOSE: To evaluate magnetic resonance (MR) imaging-controlled laser-induced thermotherapy (LITT) in the treatment of recurrent head and neck tumors. MATERIALS AND METHODS: Six patients with recurrent nasopharyngeal tumors (squamous cell carcinoma [n = 4], pleomorphic adenoma [n = 2]) underwent LITT with local anesthesia. A 7-F introducing sheath was inserted into the center of the tumor followed by a specially designed laser emitter. Therapy was monitored on-line with MR thermometry, and the amount of necrosis was estimated with dynamic and static contrast material-enhanced sequences. RESULTS: All procedures were well tolerated with use of local anesthesia, with no clinically relevant side effects. MR thermometry depicted up to 15-mm-diameter areas of less signal intensity near the laser tip. Coagulative necrosis was achieved in all patients (volume range, 4-28 cm3), and clinical symptoms were reduced in four. CONCLUSION: MR imaging-controlled LITT may be a safe, minimally invasive alternative in the treatment of recurrent head and neck tumors.

Adenoma, Pleomorphic↗

Heat storage regulation in exercise during thermal transients.

Rate of heat storage (S) was measured by using direct and indirect calorimetry simultaneously in 11 subjects during rest and exercise at three ambient temperatures (Ta of 20, 25, and 30 degrees C), and at two work intensities (40 and 90 W). At rest, the mean value of S was -64.9 W at 20 degrees C, -26.1 W at 25 degrees C, and +9.9 W at 30 degrees C. After 50 min of exercise at 40 or 90 W, S tended toward zero at the three ambient temperatures. This indicates that thermal equilibrium was reached. In addition, at the end of the exercise periods total heat losses (R + C + E) measured at a Ta of 20, 25, and 30 degrees C were similar, i.e., independent of Ta. During the thermal transients and the steady state of exercise, the calorimetric method allows immediate measurement of S to be made, since all the physical terms of the body heat balance equation are determined. The changes in mean body temperature (delta Tb) measured by thermometry showed a delay of 5-10 min when compared with delta Tb measured by calorimetry. Thus, determination of delta Tb by thermometry is not directly applicable during thermal transients, unless the observed delay is taken into account. Our results also support the concept that Tb may be the regulated variable of the thermoregulatory system, since we obtained a very significant and uniform correlation between Esk and delta Tb at the three Ta and the two work intensities which were studied.

Adult↗

Selected contribution: ambient temperature for experiments in rats: a new method for determining the zone of thermal neutrality.

There is a misbelief that the same animal has the same thermoneutral zone (TNZ) in different experimental setups. In reality, TNZ strongly depends on the physical environment and varies widely across setups. Current methods for determining TNZ require elaborate equipment and can be applied only to a limited set of experimental conditions. A new, broadly applicable approach that rapidly determines whether given conditions are neutral for a given animal is needed. Consistent with the definition of TNZ [the range of ambient temperature (T(a)) at which body core temperature (T(c)) regulation is achieved only by control of sensible heat loss], we propose three criteria of thermoneutrality: 1) the presence of high-magnitude fluctuations in skin temperature (T(sk)) of body parts serving as specialized heat exchangers with the environment (e.g., rat tail), 2) the closeness of T(sk) to the median of its operational range, and 3) a strong negative correlation between T(sk) and T(c). Thermocouple thermometry and liquid crystal thermography were performed in five rat strains at 13 T(a). Under the conditions tested (no bedding or filter tops, no group thermoregulation), the T(a) range of 29.5-30.5 degrees C satisfied all three TNZ criteria in Wistar, BDIX, Long-Evans, and Zucker lean rats; Zucker fatty rats had a slightly lower TNZ (28.0-29.0 degrees C). Skin thermometry or thermography is a definition-based, simple, and inexpensive technique to determine whether experimental or housing conditions are neutral, subneutral, or supraneutral for a given animal.

Animals↗

Thermoregulation during transurethral microwave thermotherapy: experimental and clinical fundamentals.

Transurethral microwave thermotherapy of 340 patients treated at our center for benign prostatic hypertrophy shows the importance of the role played by two thermoregulation processes during the procedure. The first one is artificial and automatically driven by the machine (the power output and cooling rate are adjusted to the urethral and rectal temperature safety thresholds). The second one is natural thermoregulation; the latter is species specific, organ specific, zone specific and even cell specific. Thermoregulation variability is linked to the geometry of the gland, vessel distribution, histology and tissue conductivity. This variability has been demonstrated by interstitial thermometry and histological study. Interstitial thermometry was performed during treatment in 30 dogs and 35 patients; a histological study of prostate specimens was performed 1-12 weeks after treatment in 30 dogs and 15 patients. The human prostate is more resistant to heat than the dog prostate of a comparable volume and treated with the same thermal dose. The prostate of a young patient requires a higher thermal dose than that of an old patient with the same prostate volume in order to achieve a comparable intraprostatic temperature, probably due to a more viable blood supply. The transition zone is more sensitive to heat than the peripheral zone, as demonstrated by temperatures recorded at the same distance from the antenna of up to 60 versus 42 degrees C, respectively. Acinar cells seem to be more resistant to heat than smooth muscle cells when exposed to the same temperature level, as demonstrated by microscopic examination at the periphery of the treated area.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Tear film dynamics in floppy eyelid syndrome.

PURPOSE: Floppy eyelid syndrome (FES) presents nonspecific ocular surface irritation. The hypothesis for the current study was that one contributing factor is the abnormality in tear film dynamics. METHODS: Sixteen patients with FES were consecutively examined. Tear film dynamics were evaluated by kinetic tear interference images, infrared thermometry, water evaporation rate, tear break-up time, and fluorescein clearance test. Data showing evaporation rate and thermometry were compared with those of 10 normal subjects. RESULTS: There was a high correlation between the eye with the worse symptoms and the eyes with the more severe floppy lids (P < 0.01) and with ocular surface evaporation rate (P = 0.02). Except for one patient, all others showed abnormal tear film, with an average tear break-up time of 2.9 +/- 3.7 seconds. Kinetic analysis of tear interference images revealed that lipid spread in a vertical or mixed pattern in 18 eyes (75%) with a delayed spread time (P = 0.0007), indicating that most of the patients had lipid tear deficiency. The ocular skin temperature and water evaporation rate were higher in the FES group (P = 0.0003 and 0.026, respectively). Nearly all patients with FES showed eyelid hyperpigmentation. The ocular surface evaporation rate in the FES group was also higher than that of the normal subjects (P < 0.0001). Multiple regression analysis showed that a vertical pattern of lipid spread had a significant influence on ocular surface evaporation rate (P = 0.003). CONCLUSIONS: Tear film abnormality is prevalent in patients with FES and is characterized by lipid tear deficiency, leading to rapid tear evaporation. The FES lid skin is also characterized by high temperature, high water evaporation rate, and hyperpigmentation. Studies directed to investigating the linkage of lid changes and meibomian gland dysfunction may shed new lights on the pathogenesis of FES.

Adult↗