Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Multiplex”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35Linked to original sources

Application of a multiplex polymerase chain reaction assay for the simultaneous confirmation of Listeria monocytogenes and other Listeria species in turkey sample surveillance.

A multiplex polymerase chain reaction was developed to simultaneously identify Listeria monocytogenes and species of the genus Listeria. Two sets of primers were used, with the first amplifying a 938-bp region of the 16S rRNA gene that is highly conserved in all Listeria species and the second amplifying a 174-bp region of the listeriolysin (hlyA) gene of L. monocytogenes. Thus, isolates of Listeria spp. yield a single 938-bp product, whereas L. monocytogenes isolates yield both the 938-bp product and a 174-bp product. The specificity of the assay was verified with all six Listeria species and 11 serotypes of L. monocytogenes, as well as nonrelated bacteria. The multiplex PCR assay was used to determine the incidence of Listeria spp., especially L. monocytogenes, in mechanically separated turkey samples (n = 150 samples). L. monocytogenes strains were selected by using the University of Vermont two-step enrichment protocol and plating to selective Palcam agar. The multiplex PCR assay was used for verification of presumptive Listeria colonies. Approximately 38% of mechanically separated turkey samples (57 of 150) yielded L. monocytogenes; an additional 18% of these samples (27 of 150) harbored other Listeria spp. Fifty-one percent (29 of 57) of the L. monocytogenes isolates were of serogroup 1, 44% (25 of 57) were of serogroup 4, and 2% (1 of 57) were assigned to serogroups other than 1 and 4.

Animals↗

Multiplex PCR for simultaneous detection of Salmonella spp., Listeria monocytogenes, and Escherichia coli O157:H7 in meat samples.

A multiplex PCR method was developed for simultaneous detection of Salmonella spp., Listeria monocytogenes, and Escherichia coli O157:H7 in meat samples. DNA detection sensitivity for this method was 10(3) CFU/ml for each pathogen. When this protocol was used for the detection of each of the above pathogenic bacteria in spiked pork samples, 1 cell per 25 g of inoculated sample could be detected within 30 h. In the samples of naturally contaminated meat, Salmonella spp., L. monocytogenes, and E. coli O157:H7 were detected over the same time period. Excellent agreement was obtained for the results of multiplex PCR and the conventional culture method, which suggests that the multiplex PCR is a reliable and useful method for rapid screening of meat products for Salmonella spp., L. monocytogenes, and E. coli O157:H7 contamination.

Animals↗

Detection of viable enterohemorrhagic Escherichia coli O157 using the combination of immunomagnetic separation with the reverse transcription multiplex TaqMan PCR system in food and stool samples.

Enterohemorrhagic Escherichia coli O157:H7 is an infectious pathogen and outbreaks have been reported all over the world, specifically in Australia, Canada, Japan, the United States, and in various countries in Europe and South Africa. Therefore, it is necessary to develop rapid methods to determine the target pathogens for food sanitation and disease. Three combinations of primers and probes were designed to detect and identify E. coli O157 using the TaqMan detection system which focuses on the specific genes eae, rfb(O157, and stxII. Reverse transcription (RT) multiplex TaqMan PCR was carried out to accurately detect viable target cells correctly. Furthermore, the acidic pretreatment and immunomagnetic separation (IMS) of food and stool samples also improved the specificity and accuracy of the RT multiplex TaqMan PCR. The developed multiplex TaqMan PCR was effective in differentiating E. coli O157, enterovirulent E. coli, and non-E. coli pathogens from 100 strains which were isolated from clinical patients and the environment. Viable and nonviable cells were also distinguished by this assay. The pretreatment protocol, which included IMS to concentrate and purify the E. coli O157, was developed and the sensitivity of the assay was improved to 10(0) CFU/ml in pure culture, food, and stool samples. The TaqMan PCR assay is a rapid test for the detection of E. coli O157 in food and stool matrices. It shortens the process time and increases the specificity of the pathogens detected. This is critical for improving the safety and sanitation of our food supply.

Adhesins, Bacterial↗

[Contribution to the problem of Arthrogryposis multiplex (author's transl)].

A case of Arthrogryposis multiplex appearing after birth and of no characteristical course is described. It is shown that in respect to existing works for diagnosis of Arthrogryposis multiplex the insufficiency of the hitherto existing valid diagnostic criterions is obvious. This especially because the pathogenesis of Arthrogryposis multiplex is unknown. Trying to look for the condition of the connective tissue of our patient, it was found that the collagen of skin shows a young matter of polymerisation and a nearly correlating electron microscopical picture.

Adult↗

Multiplexed single nucleotide polymorphism genotyping by oligonucleotide ligation and flow cytometry.

BACKGROUND: We have developed a rapid, high throughput method for single nucleotide polymorphism (SNP) genotyping that employs an oligonucleotide ligation assay (OLA) and flow cytometric analysis of fluorescent microspheres. METHODS: A fluoresceinated oligonucleotide reporter sequence is added to a "capture" probe by OLA. Capture probes are designed to hybridize both to genomic "targets" amplified by polymerase chain reaction and to a separate complementary DNA sequence that has been coupled to a microsphere. These sequences on the capture probes are called "ZipCodes". The OLA-modified capture probes are hybridized to ZipCode complement-coupled microspheres. The use of microspheres with different ratios of red and orange fluorescence makes a multiplexed format possible where many SNPs may be analyzed in a single tube. Flow cytometric analysis of the microspheres simultaneously identifies both the microsphere type and the fluorescent green signal associated with the SNP genotype. RESULTS: Application of this methodology is demonstrated by the multiplexed genotyping of seven CEPH DNA samples for nine SNP markers located near the ApoE locus on chromosome 19. The microsphere-based SNP analysis agreed with genotyping by sequencing in all cases. CONCLUSIONS: Multiplexed SNP genotyping by OLA with flow cytometric analysis of fluorescent microspheres is an accurate and rapid method for the analysis of SNPs.

Chromosomes, Human, Pair 19↗

An automated heteroduplex assay for the Pi(A) polymorphism of glycoprotein IIb/IIIa, multiplexed with two prothrombotic genetic markers.

Screening for the PIA polymorphism has been made faster and simpler with the advent of heteroduplex technology. Simultaneous screening for three common prothrombotic polymorphisms pl(A), factor V Leiden, and MTHFR(C677T) has been achieved with multiplex heteroduplex analysis. We describe a quick and simple method for PlA heteroduplex probe production. The probe was multiplexed with heteroduplex probes for MTHFR(C677T) and factor V Leiden polymorphisms in a one tube assay, allowing rapid automated genotyping of all three. This automated multiplex assay was applied to a cohort of 165 patients and showed excellent correlation with gel-based assays, both PAGE and RFLP. This approach will facilitate the analysis of multiple polymorphisms in complex disease in large populations.

Cohort Studies↗

Rapid and specific differentiation of enterotoxin-producing Escherichia coli strains from other gram-negative enteric bacteria using multiplex PCR.

Enterotoxigenic Escherichia coli (ETEC) may produce heat-labile (LT) and heat-stable (STI or STII) enterotoxins. Differentiation between ETEC and other pathogenic and non-pathogenic E. coli as well as other Gram-negative bacteria responsible for induction of diarrhoea, requires isolation, biochemical identification and determination of toxins (or their genes--elt, estI, estII). A multiplex polymerase chain reaction (PCR) system for the rapid and specific detection of enterotoxin-gene-positive E. coli was developed. The primers described by other authors, specific for the universal stress protein A (UspA) of E. coli and enterotoxin genes were used and allowed a simultaneous amplification of the E. coli-specific uspA and the respective toxin genes. The specificity of this multiplex PCR system was confirmed by testing ETEC, non-ETEC and other non-E. coli bacteria. The specific 884 bp uspA gene and 280 bp (eltI), 166 bp (estI) or 278 bp (estII) amplification products were generated with the respective ETEC strains whereas no amplification was detected with non-E. coli bacteria. The multiplex PCR developed allowed the rapid and specific identification of enterotoxin-producing E. coli colonies directly grown from faecal samples of pigs with diarrhoea. The test may be used as a method for the determination of ETEC among other pathogenic groups of E. coli and other Gram-negative enteric isolates.

Animals↗

Development of a set of multiplex PCR assays for the simultaneous identification of enterotoxigenic, enteropathogenic, enterohemorrhagic and enteroinvasive Escherichia coli.

Diarrheagenic E. coli comprise a diverse group of microorganisms responsible for gastrointestinal diseases in humans. On the basis of their virulence traits they are distinguished from the non-pathogenic E. coli and classified in several categories. Molecular methods represent the most reliable techniques for distinguishing pathogenic from non-pathogenic E. coli and characterising their pathogenic features. In this paper we report the development of a set of three multiplex PCR assays for the simultaneous and rapid identification of diarrheagenic E. coli belonging to ETEC, EPEC, EHEC and EIEC groups. Assay 1 utilizes primer pairs specific for genes coding for ST and LT toxins of ETEC, and for the E. coli beta-glucuronidase (uidA); assay 2 detects the presence of the eae and bfpA genes of EPEC, and assay 3 recognizes stx1 and stx2 of EHEC, and ial of EIEC. This technique has been validated on 190 E. coli isolated in Angola, Italy and Mozambique from feces of children with diarrhea. Results obtained with the set of multiplex PCR demonstrated 100% accordance with those obtained for the same isolates by PCR on single target genes. The proposed set of multiplex PCRs is the first reported assay that allows the simultaneous characterization of the four categories of diarrheagenic E. coli.

Angola↗

Determination of RhD zygosity: comparison of a double amplification refractory mutation system approach and a multiplex real-time quantitative PCR approach.

BACKGROUND: Rh isoimmunization and hemolytic disease of the newborn still occur despite the availability of Rh immunoglobulin. For the prenatal investigation of sensitized RhD-negative pregnant women, determination of the zygosity of the RhD-positive father has important implications. The currently available molecular methods for RhD zygosity assessment, in general, are technically demanding and labor-intensive. Therefore, at present, rhesus genotype assessment is most commonly inferred from results of serological tests. The recent elucidation of the genetic structure of the prevalent RHD deletion in Caucasians, as well as the development of real-time PCR, allowed us to explore two new approaches for the molecular determination of RhD zygosity. METHODS: Two methods for RhD zygosity determination were developed. The first was based on the double Amplification Refractory Mutation System (double ARMS). The second was based on multiplex real-time quantitative PCR. For the double ARMS assay, allele-specific primers were designed to directly amplify the most prevalent RHD deletion found in RhD-negative individuals in the Caucasian population. The multiplex real-time quantitative PCR assay, on the other hand, involved coamplification and quantification of RHD-specific sequences in relation to a reference gene, albumin, in a single PCR reaction. A ratio, DeltaCt, based on the threshold cycle, was then determined and reflects the RHD gene dosage. RESULTS: The allele-specific primers of the double ARMS assay reliably amplified the RHD-deleted allele and therefore accurately distinguished homozygous from heterozygous RhD-positive samples. The results were in complete concordance with serological testing. For the multiplex real-time quantitative PCR assay, the DeltaCt values clearly segregated into two distinct populations according to the RHD gene dosage, with mean values of 1.70 (SD, 0.17) and 2.62 (SD, 0.29) for the homozygous and heterozygous samples, respectively (P: <0.001, t-test). The results were in complete concordance with the results of serological testing as well as with the double ARMS assay. CONCLUSION: Double ARMS and real-time quantitative PCR are alternative robust assays for the determination of RhD zygosity.

Albumins↗

Validation of short tandem repeats (STRs) for forensic usage: performance testing of fluorescent multiplex STR systems and analysis of authentic and simulated forensic samples.

The amplification and typing conditions for the 13 core CODIS loci and their forensic applicability were evaluated. These loci are CSF1PO, FGA, TH01, TPOX, vWA, D3S1358, D5S818, D7S820, D8S1179, D13S317, D16S539, D18S51, and D21S11. Results were obtained using the multiplex STR systems AmpFlSTR Profiler Plus and AmpFlSTR COfiler (Applied Biosystems, Foster City, CA), GenePrint PowerPlex (Promega Corporation, Madison, WI), and subsets of these kits. For detection of fluorescently labeled amplified products, the ABI Prism 310 Genetic Analyzer, the ABI Prism 377 DNA Sequencer, the FMBIO II Fluorescent Imaging Device, and the Fluorlmager were utilized. The following studies were conducted: (a) evaluation of PCR parameter ranges required for adequate performance in multiplex amplification of STR loci, (b) determination of the sensitivity of detection of the systems, (c) characterization of non-allelic PCR products, (d) evaluation of heterozygous peak intensities, (e) determination of the relative level of stutter per locus, (f) determination of stochastic PCR thresholds, (g) analysis of previously typed case samples, environmentally insulted samples, and body fluid samples deposited on various substrates, and (h) detection of components of mixed DNA samples. The data demonstrate that the commercially available multiplex kits can be used to amplify and type STR loci successfully from DNA derived from human biological specimens. There was no evidence of false positive or false negative results and no substantial evidence of preferential amplification within a locus. Although at times general balance among loci labeled with the same fluorophore was not observed, the results obtained were still valid and robust. Suggested criteria are provided for determining whether a sample is derived from a single source or from more than one contributor. These criteria entail the following: (a) the number of peaks at a locus, (b) the relative height of stutter products, and (c) peak height ratios. Stochastic threshold levels and the efficiency of non-templated nucleotide addition should be considered when evaluating the presence of mixtures or low quantity DNA samples. Guidelines, not standards, for interpretation should be developed to interpret STR profiles in cases, because there will be instances in which the standards may not apply. These instances include (a) a primer binding site variant for one allele at a given locus, (b) unusually high stutter product, (c) gene duplication, and (d) translocation.

DNA Fingerprinting↗

[Clinical application of the medial multiplex flap pedicled with the posterior tibial vessel].

OBJECTIVE: To investigate the clinical results of the medial multiplex flap pedicled with the posterior tibial vessel. METHODS: Twelve cases with soft tissue defects and bone defects of limbs were treated with the medial multiplex flap pedicled with the posterior tibial vessel from September 1992 to May 1999. Among them, bone and soft tissue defects following opened fracture in 7 cases, chronic ulcer following chronic osteomyelitis in 2 cases, melanoepithelioma in 2 cases, bone and soft tissue defects following osteoma resection in 1 case. The bone defect area was from 2.5 cm x 5.0 cm to 4.5 cm x 11.0 cm. Free graft was performed in 5 cases, bridged transposition in 3 cases and reversal transposition in 4 cases, among them, periosteal myocutaneous flap with autogenous or allogeneic bone grafting in 8 cases, myocutaneous flap in 4 cases. The area of the flaps from 6 cm x 8 cm to 12 cm x 25 cm. RESULTS: All flaps were healed by first intention, but in the distal fragments of bigger flaps were partially necrosed in 2 cases. In 10 cases bone healing were obtained after 16 weeks of operation according to the X-ray photos. All cases were followed up from 6 to 18 months. All cases achieved satisfactory result but 1 case died because of lung metastasis of osteoma. CONCLUSION: The multiplex graft pedicled with the posterior tibial vessel is an ideal graft for repairing the large soft tissue defects and bone defects, because it has such advantages as adequate blood supply, big vascular diameter, long pedicle and big dermatomic area.

Adolescent↗

Temperature-controlled primer limit for multiplexing of rapid, quantitative reverse transcription-PCR assays: application to intraoperative cancer diagnostics.

BACKGROUND: Rapid-cycling, real-time PCR instruments bring the opportunity for improved intraoperative detection of metastasis to sentinel lymph nodes. Rapid, standardized, and internally controlled assays need to be developed that are sensitive and accurate. METHODS: We describe rapid, multiplexed, internally controlled, quantitative reverse transcription-PCR (QRT-PCR) assays for tyrosinase and carcinoembryonic antigen mRNAs on the SmartCycler (Cepheid). We used a temperature-controlled primer-limiting approach to eliminate amplification of the endogenous control gene as soon as its signal had reached threshold. Positive-control oligonucleotide mimics were incorporated into all reactions to differentiate failed reactions from true negative samples. RESULTS: The optimized assays for rapid QRT-PCR yielded results with threshold cycle values that were only 1-2 cycles higher than slower, more conventional protocols. In rapid PCR, the temperature-controlled multiplex assay was quantitative over a dynamic range of at least 15 cycles, compared with only 6 cycles for conventional multiplexing methods. All histologically positive lymph nodes examined were also QRT-PCR positive for the appropriate marker, and the exogenous, internal positive-control mimics produced signals in all negative samples. CONCLUSION: Internally controlled, rapid QRT-PCR assays can be performed in an intraoperative time frame and with sufficient sensitivity to detect histologically identified metastases to lymph nodes.

Base Sequence↗

Multiplexed, targeted gene expression profiling and genetic analysis on electronic microarrays.

BACKGROUND: Electronic microarrays comprise independent microelectrode test sites that can be electronically biased positive or negative, or left neutral, to move and concentrate charged molecules such as DNA and RNA to one or more test sites. We developed a protocol for multiplexed gene expression profiling of mRNA targets that uses electronic field-facilitated hybridization on electronic microarrays. METHODS: A multiplexed, T7 RNA polymerase-mediated amplification method was used for expression profiling of target mRNAs from total cellular RNA; targets were detected by hybridization to sequence-specific capture oligonucleotides on electronic microarrays. Activation of individual test sites on the electronic microarray was used to target hybridization to designated subsets of sites and allow comparisons of target concentrations in different samples. We used multiplexed amplification and electronic field-facilitated hybridization to analyze expression of a model set of 10 target genes in the U937 cell line during lipopolysaccharide-mediated differentiation. Performance of multiple genetic analyses (single-nucleotide polymorphism detection, gene expression profiling, and splicing isoform detection) on a single electronic microarray was demonstrated using the ApoE and ApoER2 genes as a model system. RESULTS: Targets were detected after a 2-min hybridization reaction. With noncomplementary capture probes, no signal was detectable. Twofold changes in target concentration were detectable throughout the ( approximately 64-fold) range of concentrations tested. Levels of 10 targets were analyzed side by side across seven time points. By confining electronic activation to subsets of test sites, polymorphism detection, expression profiling, and splicing isoform analysis were performed on a single electronic microarray. CONCLUSIONS: Microelectronic array technology provides specific target detection and quantification with advantages over currently available methodologies for targeted gene expression profiling and combinatorial genomics testing.

Alternative Splicing↗

Preclinical validation of a monochrome real-time multiplex assay for translocations in childhood acute lymphoblastic leukemia.

PURPOSE: The purpose is to develop a real-time multiplex reverse transcription-PCR assay for detection and quantification of leukemia-specific chimeric transcripts that identify the genetic subgroups of acute lymphoblastic leukemias (ALLs) proposed by the WHO classification. EXPERIMENTAL DESIGN: Real-time multiplex assay for t(12;21), t(4;11), and t(1;19) with hypoxanthine phosphoribosyltransferase as internal standard used in tandem with a new real time quantitative-RT-PCR assay for the t(9;22). This new strategy was designed to yield an amplicon from each translocation with a distinct melting peak allowing dependable identification using only Sybr green I, without any need for expensive hybridization probes. RESULTS: We validated this method with 92 primary ALLs and identified 4 E2A-PBX1, 4 mBCR-ABL and 10 TEL-AML1. When compared with conventional RT-PCRs and Southern blot analyses, 100% concordance was obtained. During the course of these studies, we found marked variations in the levels of the TEL-AML1 transcripts in individual patients. We, therefore, extended the study to accurately and reproducibly determine TEL-AML1 mRNA levels in 47 additional patients with t(12;21). The results indicated that the level of expression of TEL-AML1 varied among individual patients, and it was independent of the WBC count. CONCLUSIONS: Our new real-time multiplex assay can be used for rapid, simple, and reliable classification of pediatric ALL. Its reproducible quantification results should also facilitate studies on minimal residual disease. The observed variation in TEL-AML1 transcript levels is of interest because it could reflect biological and/or clinical heterogeneity in the behavior of these leukemias.

Blotting, Southern↗

[Application of multiplex semi-nested polymerase chain reaction in detection of pathogens in cerebrospinal fluid].

OBJECTIVE: To establish a new method of multiplex semi-nested polymerase chain reaction (PCR) to detect pathogens in cerebrospinal fluid (CSF). METHODS: According to the analysis of the conservative and variable regions in bacterial 16S rRNA genes, we designed universal primers for all bacteria and specific primers for most gram-positive and gram-negative bacteria. All primers were added into the same reaction systems successively of a two-step PCR assay to amplify the different bacterial DNA in CSF, and the results were compared with common culture method with sensitivity and the specificity both detected at the same time. RESULTS: Both gram-positive and gram-negative bacteria amplified DNA fragment about 1,032 bp after first-step amplification with universal primers. In the second step, specific fragments of 336 bp and 127 bp were amplified in gram-positive and gram-negative bacteria respectively besides fragments of 1,032 bp; The detection limit for E. coli was 8 cfu/ml. The comparison of 62 CSF samples detected by both multiplex semi-PCR and conventional culture method revealed sensitivity, specificity, positive and negative values of 93.8%, 95.7%, 88.2%, and 97.8% respectively for PCR. CONCLUSION: The result suggested that the multiplex semi-nested PCR we established was sensitive, specific and rapid method for clinical laboratory to detect pathogens in CSF.

Cerebrospinal Fluid↗

Design of degenerate primers for multiplex nested-PCR detection of human lymphotropic herpesviruses.

To develop the rapid diagnosis and typing of human lymphotropic herpesviruses by using multiplex nested-PCR, the primary PCR (1(o) PCR) primers were redesigned as degenerate primers based on a highly conserved sequences of each DNA polymerase gene of EBV, CMV, HHV-6, HHV-7 and HHV-8. The forward degenerate primer (HHV/1+) contained 12 different sequences, whereas there were 8 different sequences in the reverse degenerate primer (HHV/ 1-). Optimization of multiplex nested-PCR assay conditions were performed to search for the appropriate amount of degenerate primers, dNTP, Taq DNA polymerase, template of secondary PCR (2(o) PCR) and annealing temperature used in 1(o) PCR reaction. Detection sensitivity was the same as described in previous report (approximately 10-100 genome copies). To ensure a true negative result, PCR detection of hepatitis B virus genome was used as internal control. Our presented results, the designed degenerate primers could be used to detect various types of HHV by multiplex nested-PCR.

DNA Primers↗

Fluorescent multiplex linkage analysis and carrier detection for Duchenne/Becker muscular dystrophy.

We have developed a fast and accurate PCR-based linkage and carrier detection protocol for families of Duchenne muscular dystrophy (DMD)/Becker muscular dystrophy (BMD) patients with or without detectable deletions of the dystrophin gene, using fluorescent PCR products analyzed on an automated sequencer. When a deletion is found in the affected male DMD/BMD patient by standard multiplex PCR, fluorescently labeled primers specific for the deleted and nondeleted exon(s) are used to amplify the DNA of at-risk female relatives by using multiplex PCR at low cycle number (20 cycles). The products are then quantitatively analyzed on an automatic sequencer to determine whether they are heterozygous for the deletion and thus are carriers. As a confirmation of the deletion data, and in cases in which a deletion is not found in the proband, fluorescent multiplex PCR linkage is done by using four previously described polymorphic dinucleotide sequences. The four (CA)n repeats are located throughout the dystrophin gene, making the analysis highly informative and accurate. We present the successful application of this protocol in families who proved refractory to more traditional analyses.

DNA↗

Steatocystoma multiplex.

A 25-year-old man with a 20-year history of asymptomatic nodules on his arms and trunk, which histopathological analysis showed to be consistent with steatocystoma multiplex, is presented. Steatocystoma multiplex is a disorder characterized by multiple, asymptomatic, dermal cysts that usually occur on the trunk and proximal aspects of the extremities. Steatocystoma multiplex with acral predominance has only recently been described. Development of steatocystomas has been hypothesized to be due to alterations in the structure of keratin 17. Treatment for lesions has included surgical excision or drainage, oral retinoids, and liquid nitrogen cryotherapy.

Adult↗