Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Monitoring”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35Linked to original sources

The use of therapeutic drug monitoring to optimise immunosuppressive therapy.

Most experience of the therapeutic drug monitoring of immunosuppressive agents has been acquired in the field of solid organ transplantation; however, agents such as cyclosporin (cyclosporin A) are being increasingly utilised for the management of autoimmune diseases. Cyclosporin is the most widely studied immunosuppressant, but in spite of this many controversies still exist as to the optimum strategy for monitoring this drug. Owing to its widely variable pharmacokinetics and metabolism, and the absence of a simple method to measure therapeutic effectiveness, many factors should be considered. In most circumstances, measuring whole blood through concentrations of cyclosporin with a specific assay methodology is warranted. In addition, knowledge of other factors that may alter the pharmacokinetics (such as liver function, concomitant food or medications, gastrointestinal status, and time since transplantation) should be taken into account so that therapy can be appropriately adjusted. Other methods of monitoring have been investigated, such as AUC (area under the concentration-time curve) monitoring and immunological monitoring. However, further refinement of these techniques and greater experience with their efficacy must be accumulated before their role in the monitoring of cyclosporin can be defined. Tacrolimus, like cyclosporin, shares many of the difficulties in monitoring for efficacy and toxicity due largely to the variable pharmacokinetics; similarly to cyclosporin, whole blood through concentration monitoring should be utilised in combination with knowledge of the factors that may affect the pharmacokinetics. Muromonab CD3 (OKT3) is a monoclonal antibody used for the treatment and prophylaxis of acute allograft rejection. Several immunological monitoring techniques have been investigated for this agent. Monitoring CD3+ levels can assist clinicians in determining therapeutic efficacy, while measuring antimuromonab CD3 antibody titres can help determine if xenosensitisation has occurred, causing therapeutic ineffectiveness. The clinical monitoring of azathioprine, one of the first immunosuppressive agents used in transplantation, has historically been limited to monitoring complete blood counts for bone marrow suppression. However, newer techniques measuring intracellular DNA nucleotides appear to be promising. The new immunosuppressants on the horizon include mycophenolate mofetil and rapamycin. The clinical experience with therapeutic drug monitoring of these 2 compounds is scant in the literature; however, both agents have demonstrated efficacy in preventing or treating allograft rejection while maintaining a relatively well tolerated toxicity profile in recent clinical trials. Routine monitoring does not appear to be warranted for immunosuppressive therapy in autoimmune diseases.

Autoimmune Diseases↗

Evaluation of long-term home monitoring of blood glucose concentrations in cats with diabetes mellitus: 26 cases (1999-2002).

OBJECTIVE: To evaluate owner compliance with longterm home monitoring of blood glucose concentrations in diabetic cats and assess the influence of home monitoring on the frequency of reevaluation of those cats at a veterinary hospital. DESIGN: Retrospective study. ANIMALS: 26 cats with diabetes mellitus. PROCEDURE: Medical records of diabetic cats for which home monitoring was undertaken were reviewed, and owners were contacted by telephone. Signalment, laboratory test results, insulin treatment regimen, details of home monitoring, clinical signs during treatment, frequency of follow-up examinations, and survival times were evaluated. RESULTS: Monitoring of cats commenced within 12 weeks (median, 3 weeks) after initial evaluation; 8 owners were unable to perform home monitoring, and 1 cat was euthanatized after 1 week. In 17 cats, duration of home monitoring was 4.8 to 46.0 months (median, 22.0 months); 6 cats died after 7.0 to 18.0 months (median, 13.0 months). In 11 cats, home monitoring was ongoing at completion of the study (12.0 to 46.0 months' duration). Fourteen owners completed blood glucose curves every 2 to 4 weeks. Cats managed with home monitoring received higher dosages of insulin, compared with cats that were not monitored. Four of 17 cats managed by home monitoring had transient resolution of diabetes mellitus for as long as 1 year. Home monitoring did not affect the frequency of reevaluation at the veterinary hospital. CONCLUSIONS AND CLINICAL RELEVANCE: Owner compliance with long-term home monitoring appeared to be satisfactory, and home monitoring did not affect the frequency of reevaluation of patients by veterinarians.

Animal Husbandry↗

Sleeping with the enemy: clock monitoring in the maintenance of insomnia.

Two experiments that aimed to investigate the association between clock monitoring, pre-sleep worry and sleep are presented. In Experiment 1, 30 good and 30 poor sleepers were instructed either to monitor or not to monitor a clock as they were trying to get to sleep. Worry was indexed by self-rating. Sleep was measured by self-report and actigraphy. Compared to non-monitors, clock-monitors reported more pre-sleep worry and they experienced longer sleep onset latency (SOL). These findings held true for both good and poor sleepers. In Experiment 2, following one night of baseline measurement, 38 individuals diagnosed with primary insomnia were instructed to monitor either a clock or a digit display unit (a control monitoring task) as they were trying to get to sleep. The clock-monitoring task was rated to be more worry provoking and sleep interfering than the display unit-monitoring task. Whilst display unit-monitors experienced less pre-sleep worry, the clock-monitors experienced more pre-sleep worry and reported a longer SOL on the experimental night, relative to baseline. Further, compared to the display unit-monitors, the clock-monitors overestimated their SOL more on the experimental night. Together, these findings suggest that clock monitoring may trigger pre-sleep worry and serve to maintain insomnia by fuelling pre-sleep worry and exacerbating misperception of sleep.

Adult↗

Minimal monitoring of ovarian hyperstimulation: a useful simplification of the clinical phase of in vitro fertilization treatment.

OBJECTIVE: To investigate the feasibility of IVF treatment with minimal monitoring during ovarian hyperstimulation. DESIGN: Retrospective analysis and prospective study with real-time control group. SETTING: Transport IVF program with transport clinic and satellite clinics. PATIENTS: One hundred consecutive IVF cycles monitored at a transport clinic and 100 concurrent consecutive cycles monitored at satellite clinics, using the same stimulation-monitoring protocol and resulting in oocyte aspiration, are compared retrospectively for the number of ultrasound (US) measurements carried out during monitoring and for results of IVF treatment. No patient selection took place. After introduction of a minimal monitoring protocol at a transport clinic, a prospective study was started comparing 100 minimal monitoring cycles at a transport clinic with 100 concurrent conventional monitoring cycles at satellite clinics, all resulting in oocyte aspiration. Patients entered the retrospective or prospective study only once. In all cases the same laboratory facility was used. Monitoring of ovarian hyperstimulation was done with US measurements only. Cycles were canceled for impending ovarian hyperstimulation syndrome (OHSS) when > 35 follicles were seen to develop during hyperstimulation. RESULTS: Retrospective analysis shows no difference for the average number of US measurements at transport and satellite clinics (2.8 +/- 0.9 and 3.0 +/- 1.0; mean +/- SD). No differences were found in the number of ongoing pregnancies obtained in the two groups: 22 and 18, respectively. One case of severe OHSS occurred in the satellite clinic group. Introduction of minimal monitoring at the transport clinic gives a significant reduction of the average number of US measurements at the transport clinic compared with satellite clinics, where conventional monitoring continued to be used (1.5 +/- 0.8 versus 2.8 +/- 0.9). Ongoing pregnancies at transport and satellite clinics numbered 33 and 26, respectively. In both groups one patient developed severe OHSS. Sixty-two percent of cycles at the transport clinic were monitored with one US measurement only. No cancellations for impending OHSS occurred during the study period. CONCLUSION: A large group of patients need only one US measurement during monitoring of ovarian hyperstimulation. Minimal monitoring gives a useful further simplification of the clinical phase of IVF treatment, without adverse effects on treatment outcome and incidence of OHSS.

Ambulatory Care Facilities↗

Interinstitutional variation in glycohemoglobin monitoring and glycemic control of diabetic patients.

OBJECTIVES: To compare how frequently institutions monitor glycohemoglobin in diabetic patients, the level of glycemic control achieved and to identify institutional factors associated with higher rates of monitoring and lower glycohemoglobin levels. METHODS: A total of 212 institutions retrospectively abstracted laboratory and outpatient records of up to 30 diabetic patients who had initial glycohemoglobin monitoring performed in their laboratories. Data from a cohort of 5586 diabetic patients and 17 365 assays were analyzed. RESULTS: Overall, 31.3% of patients underwent glycohemoglobin monitoring at least quarterly, the frequency recommended by the American Diabetes Association (ADA) to stabilize patients at target hemoglobin A(1c) (HbA(1c)) levels. A total of 64.9% of patients were monitored at least semiannually, the ADA recommendation for patients with stable diabetes in glycemic control (final HbA(1c) level <7%). When we compared the top and bottom deciles of the 212 institutions, there was more than an eightfold difference in the proportion of patients monitored at least quarterly and more than a twofold difference in the proportion of patients monitored at least semiannually. Glycemic control was assessed by examining the value of the last glycohemoglobin determination on record after at least 8 months of management. For all 5586 diabetic patients, the median value of the last HbA(1c) assay was 7.4%. Comparing the top and bottom deciles, there was almost a fourfold difference among institutions in the proportion of diabetic patients in glycemic control. The use of reminders to order glycohemoglobin monitoring was associated with higher rates of semiannual monitoring (P <.05) and tighter glycemic control (P <.05). In addition, patients who were monitored more frequently experienced glycohemoglobin reductions of greater magnitude (P <.001). The presence of diabetes clinics and the use of rapid methods for testing glycohemoglobin were not associated with monitoring frequency or glycohemoglobin levels. CONCLUSIONS: There is wide interinstitutional variation in the frequency with which diabetic patients are monitored and the level of glycemic control achieved. The use of prompting systems to remind providers to order glycohemoglobin monitoring was associated with more frequent monitoring and superior glycemic control.

Blood Glucose↗

Continuous glucose monitoring for the evaluation and improved control of gestational diabetes mellitus.

OBJECTIVES: To compare the daily glycemic profile reflected by continuous versus self-monitoring of blood glucose in women with gestational diabetes mellitus (GDM), and to evaluate possible differences in treatment strategy based on the two monitoring methods. MATERIALS AND METHODS: The study sample consisted of 57 women with gestational diabetes, 47 in Israel and ten in California. Gestational age ranged from 24 to 32 weeks in the Israeli women, and 32 to 36 weeks in the American women. Data derived from the Continuous Glucose Monitoring (CGM) System (MiniMed) for 72 h were compared to fingerstick glucose measurements (6-8 times a day). During continuous monitoring, patients documented the timing of food intake, insulin injections and hypoglycemic events. RESULTS: In the Israeli group, 23 women were treated by diet alone, and 24 by diet plus insulin. An average of 763 +/- 62 glucose measurements was recorded for each patient with continuous glucose monitoring. The mean total time of hyperglycemia (glucose level > 140 mg/dl) undetected by the fingerstick method was 132 +/- 31 min/day in the insulin-treated group and 94 +/- 23 min/day in the diet-treated group. Nocturnal hypoglycemic events (glucose levels < 50 mg/dl) were recorded in 14 patients, all insulin-treated. On the basis of the additional information provided by continuous monitoring, the therapeutic regimen (insulin therapy, diet adjustment, or both) was changed in 36 of the 47 patients. All ten American women were treated with insulin. The mean time of undetected hyperglycemia for a total group monitoring time of 30 days was 78 +/- 13 min/day. Eight women had nocturnal hypoglycemia on at least one of the three nights of monitoring for a total of 12 nights. A change in insulin dosage was made in all women on the basis of the data provided by continuous glucose monitoring. CONCLUSION: Continuous glucose monitoring is helpful for monitoring women with GDM and for adjusting diabetes therapy. It can accurately detect high postprandial blood glucose levels and nocturnal hypoglycemic events that may go unrecognized by intermittent blood glucose monitoring. A large prospective study on maternal and neonatal outcome is needed to determine the clinical implications of this new monitoring technique.

Adult↗

Detection of electrographic seizures with continuous EEG monitoring in critically ill patients.

OBJECTIVE: To identify patients most likely to have seizures documented on continuous EEG (cEEG) monitoring and patients who require more prolonged cEEG to record the first seizure. METHODS: Five hundred seventy consecutive patients who underwent cEEG monitoring over a 6.5-year period were reviewed for the detection of subclinical seizures or evaluation of unexplained decrease in level of consciousness. Baseline demographic, clinical, and EEG findings were recorded and a multivariate logistic regression analysis performed to identify factors associated with 1) any EEG seizure activity and 2) first seizure detected after >24 hours of monitoring. RESULTS: Seizures were detected in 19% (n = 110) of patients who underwent cEEG monitoring; the seizures were exclusively nonconvulsive in 92% (n = 101) of these patients. Among patients with seizures, 89% (n = 98) were in intensive care units at the time of monitoring. Electrographic seizures were associated with coma (odds ratio [OR] 7.7, 95% CI 4.2 to 14.2), age <18 years (OR 6.7, 95% CI 2.8 to 16.2), a history of epilepsy (OR 2.7, 95% CI 1.3 to 5.5), and convulsive seizures during the current illness prior to monitoring (OR 2.4, 95% CI 1.4 to 4.3). Seizures were detected within the first 24 hours of cEEG monitoring in 88% of all patients who would eventually have seizures detected by cEEG. In another 5% (n = 6), the first seizure was recorded on monitoring day 2, and in 7% (n = 8), the first seizure was detected after 48 hours of monitoring. Comatose patients were more likely to have their first seizure recorded after >24 hours of monitoring (20% vs 5% of noncomatose patients; OR 4.5, p = 0.018). CONCLUSIONS: CEEG monitoring detected seizure activity in 19% of patients, and the seizures were almost always nonconvulsive. Coma, age <18 years, a history of epilepsy, and convulsive seizures prior to monitoring were risk factors for electrographic seizures. Comatose patients frequently required >24 hours of monitoring to detect the first electrographic seizure.

Adult↗

Home apnea monitoring and sudden infant death syndrome.

OBJECTIVE: To estimate the U.S. national prevalence of apnea monitor use by birth weight classification and to examine the relationship between the use of apnea monitors and the occurrence of Sudden Infant Death Syndrome (SIDS). DESIGN AND SETTING: Data obtained from the 1988 National Maternal and Infant Health Survey (NMIHS) were used. Prevalence estimates of apnea monitor use were obtained by weighting survey data, and the relationship between monitor use and SIDS was accomplished by a case-control analysis using SIDS deaths and live controls obtained from the NMIHS. OUTCOME MEASURE: Weighted estimates of the prevalence of apnea monitor use and odds ratios for the odds of use of an apnea monitor among SIDS victims compared with the odds of use of an apnea monitor among living controls. RESULTS: The national prevalence estimates for home apnea monitor use among birth weight strata of 500 to 1,499 g, 1,500 to 2,499 g, and 2,500 g or more for blacks were 19.9, 2.6, and 1.1% compared with 44.0, 8.8, and 1.2% for non-blacks. The only significant association between the use of apnea monitors and SIDS was for black 500- to 1,499-g infants. The adjusted odds ratio for SIDS among monitored black 500- to 1,499-g infants vs unmonitored infants was 3.93 (1.09, 14.17). CONCLUSIONS: This analysis suggests a marked difference in reported monitor use between U.S. black and non-black infants. In addition, black very low birth weight infants at highest risk for SIDS appear to be preferentially selected for monitoring. The protective effect of home apnea monitoring in this survey population is unclear.

Black or African American↗

Stream restoration and enhancement projects: is anyone monitoring?

Declines in salmon stocks and general watershed health in Washington State, USA, have led to an increase in stream restoration and enhancement projects initiated throughout the state. The increasing number of projects has also raised questions regarding the monitoring of these efforts. Project managers receiving hydraulic project approvals (HPAs) were surveyed to determine whether monitoring was taking place on their projects. About half the project managers surveyed reported the collection of baseline data and the use of biological, physical, chemical, or other water quality measures for their projects. Of those who reported collection of monitoring data, only 18% indicated that monitoring was required. Respondents were also asked to rank the importance of various project goals on a Likert scale. Project managers with projects focusing on "engineering" goals (e.g., roadbed stabilization) were less likely than other project managers to collect baseline monitoring data. Project managers with projects focusing on "restoration/ecological" or "fisheries" goals were more likely than other project managers to collect monitoring measures. Although monitoring appears to be taking place in slightly more than half of the projects surveyed, the nature of the data collected varies widely across projects, and in most cases the monitoring effort is voluntary. This suggests that project sponsors, funders, and managers must consider the issues involved in requiring appropriate monitoring, establishing standardized monitoring guidelines, the time frames in which to monitor, providing other incentives for conducting monitoring, and ensuring adequate funding for monitoring efforts.

Animals↗

Identifying and closing gaps in environmental monitoring by means of metadata, ecological regionalization and geostatistics using the UNESCO biosphere reserve Rhoen (Germany) as an example.

In Germany, environmental monitoring is intended to provide a holistic view of the environmental condition. To this end the monitoring operated by the federal states must use harmonized, resp., standardized methods. In addition, the monitoring sites should cover the ecoregions without any geographical gaps, the monitoring design should have no gaps in terms of ecologically relevant measurement parameters, and the sample data should be spatially without any gaps. This article outlines the extent to which the Rhoen Biosphere Reserve, occupying a part of the German federal states of Bavaria, Hesse and Thuringia, fulfills the listed requirements. The investigation considered collection, data banking and analysis of monitoring data and metadata, ecological regionalization and geostatistics. Metadata on the monitoring networks were collected by questionnaires and provided a complete inventory and description of the monitoring activities in the reserve and its surroundings. The analysis of these metadata reveals that most of the monitoring methods are harmonized across the boundaries of the three federal states the Rhoen is part of. The monitoring networks that measure precipitation, surface water levels, and groundwater quality are particularly overrepresented in the central ecoregions of the biosphere reserve. Soil monitoring sites are more equally distributed within the ecoregions of the Rhoen. The number of sites for the monitoring of air pollutants is not sufficient to draw spatially valid conclusions. To fill these spatial gaps, additional data on the annual average values of the concentrations of air pollutants from monitoring sites outside of the biosphere reserve had therefore been subject to geostatistical analysis and estimation. This yields valid information on the spatial patterns and temporal trends of air quality. The approach illustrated is applicable to similar cases, as, for example, the harmonization of international monitoring networks.

Ecology↗

Multicenter randomized clinical trial of home uterine activity monitoring for detection of preterm labor.

Home uterine activity monitoring has been described as an effective means of detecting uterine contractions, but controversy exists whether it is home uterine activity monitoring or increased nursing support in conjunction with it that contributes to earlier detection of preterm labor. In this study 377 women at risk for preterm labor from three centers were prospectively, randomly assigned to high-risk prenatal care alone (not monitored) or to the same care with twice-daily home uterine activity monitoring without increased nursing support (monitored). The two groups were medically and demographically similar at entry into the study. Routine visits, nonroutine visits, and gestational age at diagnosis of preterm labor were similar in both groups. Preterm labor occurred in 41 of 198 monitored and 39 of 179 not monitored patients. Mean cervical dilatation was 1.4 cm in 41 monitored compared with 2.5 cm for 37 not monitored (p = 0.0006); 73.1% of monitored and 27.5% of not monitored had preterm labor detected before 2 cm dilatation (p = 0.00009). Neonatal outcome of singleton pregnancies showed greater birth weight, fewer days in the neonatal intensive care unit, and fewer babies requiring oxygen therapy and mechanical ventilation in the monitored group. The better outcomes are probably due to the increased likelihood of diagnosis of preterm labor before advanced cervical dilatation with home uterine activity monitoring, thus providing the clinician with a better chance to initiate tocolytic therapy directed at improving pregnancy outcome.

Birth Weight↗

A metaanalysis of home uterine activity monitoring.

OBJECTIVE: Our purpose was to assess by metaanalysis the evidence from randomized clinical trials regarding home uterine activity monitoring. STUDY DESIGN: Six randomized controlled trials of home uterine activity monitoring, the same six trials reviewed by the U.S. Preventive Services Task Force on home uterine activity monitoring, were studied. Data were extracted from published reports of the six trials. In addition, unpublished data were obtained by personal communication from the trials' principal investigators. Insofar as possible, the principle of intention-to-treat was maintained. Data regarding twins were handled by use of numbers of pregnancies rather than numbers of infants as sample sizes. Stratified metaanalyses were conducted according to whether the trial did or did not control in study design for the nursing contact factor that accompanies home uterine activity monitoring. In addition, stratified metaanalyses were conducted for singleton and twin pregnancies. The four outcomes investigated were incidence of preterm birth, incidence of preterm labor combined with cervical dilatation > 2 cm, infant referral to the intensive care unit, and mean birth weight. RESULTS: Overall, for all pregnancies home uterine activity monitoring was associated with a statistically significant reduction of 52% in risk of preterm labor combined with cervical dilatation > 2 cm (relative risk = 0.48, p = 0.001) and a statistically significant increase of 86 gm in mean birth weight (p = 0.038). When stratified by singleton or twin pregnancy, the pooled results generally differed by strata. Among singleton pregnancies, home uterine activity monitoring was associated with a statistically significant reduction of 24% in risk of preterm birth (relative risk 0.76, p = 0.037) and a statistically significant increase of 126 gm in mean birth weight (p = 0.009). Among twin pregnancies, there was a statistically significant effect of home uterine activity monitoring with a reduction of 56% in risk of preterm labor combined with cervical dilatation > 2 cm (relative risk 0.44, p = 0.005). There were no statistically significant effects found overall and in any stratum with regard to infant referral to the intensive care unit. Metaanalyses of studies that controlled in design for the nursing contact factor that accompanies home uterine activity monitoring showed either no difference or stronger pooled effects compared with metaanalyses of those studies that did not control for nursing contact. This suggests that the potential bias attributed to the nursing contact feature that accompanies home uterine activity monitoring is not as appreciable as home uterine activity monitoring critics have suggested. CONCLUSIONS: Metaanalysis of existing clinical trial evidence regarding home uterine activity monitoring reveals statistically significant benefits of home uterine activity monitoring. Of the outcomes investigated, home uterine activity monitoring is associated with reductions in risks of preterm birth (in singleton pregnancies only) and preterm labor combined with cervical dilatation > 2 cm, as well as with increased mean birth weight (in singleton pregnancies only).

Female↗

A randomized comparison of home uterine activity monitoring in the outpatient management of women treated for preterm labor.

OBJECTIVE: The aim of the study was to evaluate home uterine activity monitoring as an intervention in reducing the rate of preterm birth among women treated for preterm labor. STUDY DESIGN: A total of 186 women were treated in the hospital with magnesium sulfate for preterm labor and were prospectively randomly assigned to study groups; among these, 162 were ultimately eligible for comparison. Eighty-two of these women were assigned to the monitored group and 80 were assigned to an unmonitored control group. Other than monitoring, all women received identical prenatal follow-up, including daily perinatal telephone contact and oral terbutaline therapy. Outcome comparisons were primarily directed toward evaluation of preterm birth at <35 weeks' gestation. Readmissions for recurrent preterm labor and observations lasting <24 hours were evaluated in monitored and unmonitored groups. Compliance with monitoring was also evaluated in the monitored group. RESULTS: The monitored and control groups were demographically similar. According to a multivariate logistic regression model, women with cervical dilatation of >/=2 cm were 4 times more likely to be delivered at <35 weeks' gestation (P <.05). Gestational ages at delivery were similar in the monitored and control groups. There was no significant difference in the overall rate of preterm delivery at <35 weeks' gestation between the monitored group (10.9%) and the control group (15.0%). The overall rates of delivery at <37 weeks' gestation were high (48.8% and 60.0% for monitored and control groups, respectively), and the difference was not significant. The numbers of women with >/=1 instance of readmission and treatment for recurrent preterm labor were equal in the monitored and control groups. The numbers of women with >/=1 hospital observation lasting <24 hours were not different between the groups. Compliance with monitoring did not significantly differ for women who were delivered at <35 weeks' gestation, women with >/=2 cm cervical dilatation at enrollment, or for African American women. CONCLUSION: A reduction in the likelihood of preterm delivery at <35 weeks' gestation was not further enhanced by the addition of home uterine monitoring to the outpatient management regimens of women treated for preterm labor.

Adolescent↗

Monitoring of patients with head injuries.

A practical protocol for evaluating and monitoring head injured patients has been presented. It has been stressed that monitoring is an ongoing process which begins with the initial evaluation and continues throughout the patient's hospital stay. The level of monitoring and thus the parameters to be monitored are determined on an individualized basis according to the patient's clinical status and his level of stupor and coma. It has been suggested that for mild head injuries, adequate monitoring includes periodic evaluation of the neurological status and vital signs; but the more severely injured patients require extensive and frequent monitoring of a large number of clinical and physiological parameters. Among the many parameters, the continuous monitoring of ICP and the respiratory system are perhaps the most useful indicators of the patient's condition. Several methods for continuous ICP monitoring which are readily adaptable to most neurosurgical practices have been discussed. These include the intraventricular catheter, subarachnoid screw, and the closed Rickham reservoir connected to a ventricular catheter. In our institution, the Rickham reservoir has been used to monitor ICP and at the time of this report, satisfactory ICP recordings have been obtained in 27 of 30 head injury patients. Although this method requires a small surgical procedure, we believe that the decreased incidence of infection, the rapid access to ventricular fluid, and its potential for long term monitoring justify its use. Suggestions for monitoring other physiological parameters have also been presented. Particular emphasis has been placed on the management of infants and children with head injuries. The clinical entity of chronic subdural hematoma in infants and children has been used to illustrate the value of ICP monitoring as a guide to further treatment. Finally, we have briefly discussed the place of computers in day to day patient care, research, and monitoring.

Blood Pressure↗

Electrocardiographic electrodes provide the same results as expensive special sensors in the routine monitoring of anesthetic depth.

UNLABELLED: The Bispectral Index (BIS) is a mathematically derived electroencephalographic (EEG) derivative that has been introduced to monitor depth of anesthesia (1,2). The A-2000 BIS monitoring system (Aspect Medical Systems, Inc., Newton, MA) is currently the only commercially available system to monitor depth of anesthesia. In several studies, its propensity to optimize the use of hypnotics to maintain and achieve a certain depth of anesthesia has been described (3,4). Some studies have even proposed that the routine use of the monitoring system can decrease awareness (1,5), an increasing factor in malpractice claims. The cost-benefit calculations for BIS monitoring suffer from the fact that like its predecessor, the 1000-A BIS monitor, the A-2000 BIS monitoring system demands the use of expensive, special electrodes (6). Although the application of the single-use BIS sensor is very comfortable and easy to use, its high price of approximately $10-20 US prevents many anesthesiologists from using it. Furthermore, whereas the former model of the monitor (1000-A BIS monitor; Aspect Medical Systems, Inc.) used standardized connectors, which allowed the use of other electrodes such as electrocardiogram (ECG), the new monitoring system makes this very difficult because of special connectors that match the equivalent connector at the proximal BIS sensor site. The purpose of this prospective study was to compare BIS values derived from the original BIS sensor with BIS values derived from commercially available ECG electrodes. This comparison was made possible by designing and manufacturing a connector allowing the use of ECG electrodes. IMPLICATIONS: The Bispectral Index (BIS) monitor adequately monitors depth of anesthesia. The routine use of this monitor has been hampered by the benefit-cost equation because only special expensive electrodes can be used. We examined the agreement of BIS values obtained by original sensor electrodes and commercial electrocardiogram (ECG) electrodes. These ECG electrodes can replace more expensive BIS sensors.

Anesthesia, General↗

Comparison of jugular venous oxygen saturation and brain tissue Po2 as monitors of cerebral ischemia after head injury.

OBJECTIVE: To compare the characteristics of jugular venous oxygen saturation (Sjvo2) and brain tissue Po2 (Pbto2) as monitors for cerebral ischemia after severe head injury. Sjvo2 has been useful as a monitor for cerebral ischemia, but it is limited by its inability to identify regional cerebral ischemia. Pbto2 may be superior to Sjvo2 for this purpose, because oxygenation in localized areas of the brain can be monitored. DESIGN: Sjvo2 and Pbto2 were successfully monitored in 58 patients with severe head injury. The changes in Sjvo2 and Pbto2 were compared during ischemic episodes. SETTING: Neurosurgical intensive care unit of a level I trauma center. MEASUREMENTS AND MAIN RESULTS: During the monitoring period, which averaged 90 hrs/patient, there were 54 episodes during which Sjvo2 decreased to <50% and/or Pbto2 decreased to <8 torr. Two of these episodes were caused by an infarction in the area of the Po2 probe, leaving 52 episodes of global hypoxia/ischemia that were identified by one of the two monitors. The sensitivities of the two monitors for detecting ischemia, using the thresholds of 50% and 8 torr for Sjvo2 and Pbto2, respectively, were similar. The Sjvo2 catheter detected 69.7% of the episodes and the Pbto2 catheter detected 63.5% of the episodes. In most of the remaining episodes, both probes reflected a decrease in oxygenation, but not to levels below the defined thresholds. The major differences in the two measures of oxygenation included the following: a) Sjvo2 more consistently reflected a reduction in oxygenation during hyperventilation; b) Pbto2 was affected more by changes in arterial Po2; and c) during severe global ischemia, Pbto2 decreased to 0 and remained at 0, whereas Sjvo2 initially decreased but then increased again as cerebral blood flow ceased, and the only blood in the jugular bulb was of extracerebral origin. CONCLUSIONS: The two monitors provide complimentary information, and neither monitor alone identifies all episodes of ischemia. The best strategy for using these monitors is to take advantage of the unique features of each monitor. Sjvo2 should be used as a monitor of global oxygenation; but Pbto2 should be used as a monitor of local oxygenation, ideally with the catheter placed in an area of the brain that is vulnerable to ischemia but that may be salvageable with appropriate treatment.

Adult↗

Carbon dioxide monitoring in emergency medicine training programs.

OBJECTIVES: Although the measurement of carbon dioxide (CO2) in breath is the standard of care for verification of endotracheal tube placement in all anesthesia practice and in the prehospital setting, there is currently no uniform consensus on the status of CO2 monitoring in emergency medicine. We conducted this survey to delineate practice patterns of CO2 monitoring in academic emergency medicine training programs and to describe the preference for type of CO2 monitoring device. METHODS: We surveyed the availability, presence, and types of CO2 monitoring in all general emergency medicine (GEM) residency programs and all pediatric emergency medicine (PEM) fellowship programs. A two-question survey was used, and data were collected from March 1998 to June 1998. The clinicians surveyed were asked whether their emergency department (ED) used CO2 monitoring for detection of endotracheal tube placement and, if so, what type of CO2 monitoring devices was used. Types of CO2 monitoring devices were categorized as colorimetric, capnometric, capnographic, or combinations of these. RESULTS: Of the 168 programs surveyed, all GEM and PEM programs responded, and the survey results showed that 136 of 168 (81%) used some form of CO2 monitoring, and 32 of 168 (19%) did not use CO2 monitoring. The majority of programs (115/168, 68%) used a single device. Colorimetric devices were used most frequently (76/168, 45%), and capnometry was used the least (9/168, 5%). PEM programs had a significant preference for quantitative CO2 monitoring, whereas GEM programs had a significant preference for qualitative CO2 monitoring. CONCLUSIONS: Although the majority of academic emergency medicine training programs used CO2 monitoring, 19% did not. Colorimetric devices were the most frequently used CO2 monitoring technology.

Carbon Dioxide↗

Home blood pressure self-monitoring: diagnostic performance in white-coat hypertension.

OBJECTIVE: To determine the diagnostic performance of home blood pressure self-monitoring in white-coat hypertension using a 3-day reading program. MATERIAL AND METHODS: One hundred and ninety nontreated patients recently diagnosed with mild-moderate hypertension, selected consecutively at four primary healthcare centers in the city of Barcelona, were included. Each patient underwent morning and night home blood pressure self-monitoring with readings in triplicate for three consecutive days, followed by 24-h ambulatory blood pressure monitoring. The normality cut-off point value for home blood pressure self-monitoring and daytime ambulatory blood pressure monitoring was 135/85 mmHg. RESULTS: Sixty-three patients were diagnosed with white-coat hypertension with home blood pressure self-monitoring (34.8%; 95% confidence interval: 27.9-42.2) and 74 with ambulatory blood pressure monitoring (41.6%; 95% confidence interval: 33.7-48.4). No statistically significant differences were observed between home blood pressure self-monitoring values and those of diurnal ambulatory blood pressure monitoring [137.4 (14.3)/82.1 (8.3) mmHg vs. 134.8 (11.3)/81.3 (9.5) mmHg]. Home blood pressure self-monitoring diagnostic performance parameters were sensitivity 50.0% (95% confidence interval: 38.3-61.7), specificity 75.7% (95% confidence interval: 66.3-83.2), positive and negative predictive values 58.7% (95% confidence interval: 45.6-70.8) and 68.6% (95% confidence interval: 59.4-76.7), respectively, and positive and negative probability coefficients 2.05 and 0.66, respectively. Analysis of different normality cut-off points using a receiver operating characteristic curve failed to produce significant improvement in the diagnostic performance of home blood pressure self-monitoring. CONCLUSIONS: The diagnostic accuracy of a 3-day home blood pressure self-monitoring reading program in white-coat hypertension was poor. Ambulatory blood pressure monitoring continues to be the test of choice for this indication.

Adolescent↗