Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “MAGNETICS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35Linked to original sources

Dual in vivo magnetic resonance evaluation of magnetically labeled mouse embryonic stem cells and cardiac function at 1.5 t.

Cell therapy has demonstrated the potential to restore injured myocardium. A reliable in vivo imaging method to localize transplanted cells and monitor their restorative effects will enable a systematic investigation of this therapeutic modality. The dual MRI capability of imaging both magnetically labeled mouse embryonic stem cells (mESC) and their restorative effects on cardiac function in a murine model of acute myocardial infarction is demonstrated. Serial in vivo MR detection of transplanted mESC and monitoring of the mESC-treated myocardium was conducted over a 4-week period using a 1.5 T clinical scanner. During the 4-week duration, the mESC-treated myocardium demonstrated sustained improvement of the left ventricular (LV) ejection fraction and conservation of LV mass. Furthermore, no significant difference of their restorative effects on the cardiac function was created by the magnetic labeling of mESC. Thus, in vivo MRI enables simultaneous detection of transplanted mESC and their therapeutic effect on the injured myocardium.

Animals↗

The trajectories of particles suspended in electrolytes under the influence of crossed electric and magnetic fields. Possible explanation of the sensitivity of organism to magnetic fields.

We observed that particles, suspended in an electrolyte and brought into crossed magnetic and electric fields of low intensities, will deviate in the central part of the electrophoresis chamber of a standard Zeiss Cytopherometer with a component vertical to both fields. The direction and magnitude, however, were sharply at variance with what would be expected by the action of the Lorentz force (EMF) on the surface of the particles. The magnitude of the deviation depends upon the magnetic and electric field strength, the ion concentration of the suspension medium and the geometry of the chamber. The movement of the particles is due to streaming of the electrolyte which is mainly caused by inhomogeneities of the electric field in the electrophoresis chamber. The magnitude of the effect is high enough to occur physiological conditions. Magneto-electrophoretic streaming might eventually act as a transducer mechanism which could explain the ability of some animals to orientate themselves in the geomagnetic field.

Electricity↗

Comparison of magnetic resonance angiography, magnetic resonance imaging and conventional angiography in cerebral arteriovenous malformation.

10 patients with an AVM of the brain were examined by magnetic resonance angiography (MRA), magnetic resonance imaging (MRI) and conventional cerebral angiography (CCA). From MRA in 7/10 patients important information about vascular supply could be provided; in 3 patients, all with small AVM's it could be only suspected. CCA revealed the vascularisation of the AVM's in all patients and showed additional hemodynamic aspects better than MRA. With MRI in all cases the AVM could be diagnosed, but only the involvement of the main cerebral vessels could be demonstrated: however, MRI is superior to MRA and CCA in showing the nidus and the involved brain structures.

Adolescent↗

Can magnetization transfer magnetic resonance imaging follow proteoglycan depletion in articular cartilage?

In this study we determined the efficiency of magnetization transfer magnetic resonance imaging (MT-MRI) to differentiate native and enzymatically degraded cartilage, using bovine sesamoid bones from the metacarpophalangeal joint as a model system. Gradual proteoglycan (PG) depletion was achieved by increasing incubation periods with testicular hyaluronidase. For native cartilage a Ms/Mo ratio of 0.303 +/- 0.09 (mean +/- SEM) was measured. Biochemically determined PG diminution up to 50% correlated strongly (r = 0.953) with changes in the Ms/Mo ratio. Further PG loss is not reflected in an equally drastic Ms/Mo increase, whereas subsequent treatment of PG-depleted cartilage samples with collagenase led to an additional rise in the Ms/Mo ratio. Proteoglycan depletion and the beginning destruction of the collagen structure were also assessed histochemically. Our study confirms that collagen contributes to the baseline MT effect observed in articular cartilage. However, the changes in the MT ratio in gradually PG-depleted cartilage with a largely intact collagen network indicate that PG contributes to the MT effect as well. Therefore MT-MRI might become a sensitive technique for the monitoring of subtle degradational changes in articular cartilage, the still inaccessible process in osteoarthritis.

Animals↗

Icteric-type hepatoma: magnetic resonance imaging and magnetic resonance cholangiographic features.

BACKGROUND: We evaluated the imaging features of magnetic resonance imaging (MRI) and magnetic resonance cholangiography (MRC) of icteric-type hepatoma and correlated these with the findings of endoscopic retrograde cholangiography (ERC), percutaneous cholangiography, and surgery. METHODS: Thirteen patients with viral hepatitis complicated by cirrhosis of the liver and obstructive jaundice underwent MRC and dynamic MRI. Five patients received percutaneous transhepatic cholangiography and drainage; one of these patients also underwent resection of the left hepatic lobe. Another patient received MRC followed by thrombectomy and T-tube insertion. ERC and endoscopic nasobiliary drainage were performed in another patient for bile diversion. RESULTS: Primary liver tumors and dilatation of biliary system were demonstrated in all patients. No capsule formation could be found in any primary liver tumors. MRI showed the simultaneous presence of an intraluminal tumor in the portal trunk and common hepatic duct in eight patients. Three different MRC features were found: (a) an oval defect in the hilar bile duct(s) with dilated intrahepatic ducts (n = 9), (b) dilated intrahepatic ducts with missing major bile ducts (n = 2), and (c) localized stricture of the hilar bile duct(s) (n = 2). CONCLUSION: The presence of one or more of the following features in multiplanar MRI and MRC help to identify this rare, specific type of hepatocellular carcinoma: (a) the presence of an intraluminal tumor in both the portal trunk and the common hepatic duct, (b) enhancement of the intraluminal tumor in the common hepatic duct on the arterial phase, (c) type I MRC feature, and (d) hemobilia, blood clot within the gallbladder, and/or type II MRC feature.

Adult↗

Magnetic resonance urography for the assessment of potential renal donors: comparison of the RARE technique with a low-dose gadolinium-enhanced magnetic resonance urography technique in the absence of pharmacological and mechanical intervention.

The aim of this study was to determine whether magnetic resonance urography without pharmacological (diuretic) stimulation and mechanical compression allows conclusive evaluation of the urinary system in potential renal donors. In 28 consecutive patients magnetic resonance urography (MRU) was performed on a 1.5-T system. Two techniques, rapid acquisition with relaxation enhancement (RARE) and a gadolinium (Gd)-enhanced 3D fast low angle shot (FLASH) sequence were compared in the absence of adjunctive measures. Two reviewers assessed image quality, presence of artifacts and completeness of visualization of the collecting systems and ureters. Among the 53 MR urograms, there was no difference in image quality and presence of artifacts between RARE and Gd-MRU. Despite high image quality, visualization of the urinary collecting system was insufficient. Continuous visualization from the collecting system to the distal ureter was demonstrated bilaterally in only 14% of the RARE and 26% of Gd-enhanced MR urograms, respectively. Overall, Gd-enhanced MRU was superior to the RARE technique in displaying the segments of the urinary collecting system, but this difference was not found to be statistically significant. Neither the RARE technique nor the gadolinium-enhanced MRU technique is accurate enough to allow the evaluation of the collecting system and ureters in potential renal donors in the absence of pharmacological intervention and compression.

Adult↗

Detection and characterization of hyperfine-shifted resonances in the proton nuclear magnetic resonance spectrum of Anabaena 7120 ferredoxin at high magnetic fields.

This paper presents previously unobserved signals in the 1H NMR spectra of oxidized and reduced [2Fe-2S]-ferredoxin from Anabaena 7120 detected at 400, 500, and 600 MHz. The signals shifted to low field exhibited longitudinal relaxation (T1) values in the range of 100-400 microseconds and line widths in the range of 1-10 kHz (at 400 MHz), and the chemical shifts of all signals showed strong temperature dependence. Although the line widths were smaller at lower magnetic fields, the resolution was better at higher magnetic fields. In the oxidized state, a broad signal was detected at 37 ppm, which corresponds to at least 6 protons, and whose chemical shift exhibits positive temperature dependence. This signal also was found in oxidized ferredoxin reconstituted in 2H2O, which excludes the signal as arising from solvent-exchangeable amide protons. In the reduced state, four signals detected between 90 and 140 ppm exhibited negative temperature dependence. These consisted of two pairs of signals, each pair having one component with half the linewidth of the other. On the basis of their chemical shifts, linewidths, longitudinal relaxation properties, and temperature dependence we assigned these resonances to four of the beta hydrogens of the ligated cysteines. Two solvent-exchangeable hyperfine-shifted signals were found in the reduced state; these are located upfield of the diamagnetic region. The low-field hyperfine resonances of half-reduced ferredoxin in the presence of sodium dithionite showed a self electron transfer exchange rate that was slow on the NMR scale as observed earlier (Chan, T., and Markley, J. L. (1983) Biochemistry 22, 5982-5987), but the exchange rate was accelerated in the presence of methyl viologen.

Eukaryota↗

Mössbauer investigation of deoxymyoglobin in a high magnetic field. Orientation of the electric field gradient and magnetic tensors.

We have examined the Mössbauer spectra of deosymyoglobin in a 6 T magnetic field in the temperature range 4.2-195 K. Spectra were fitted by the least-squares method using a phenomenological model in which the internal magnetic hyperfine field was assumed to be related to the applied field by a temperature dependent tensor õmega. The results indicate that õmega has axial symmetry and a principal axis system aligned with that of the electric field gradient (efg). The principal component of the latter is negative and lies on the symmetry axis of õmega. Our fits indicate that of efg asymmetry parameter is eta = 0.7, with no appreciable temperature dependence. Both axial and transverse components of õmega have the expected 1/T temperature dependence for T greater than 20 K. Our experimentally determined value of eta, combined with published single crystal zero-field measurements, constrains the efg-heme relative orientation to two possibilities. In neither of these is an efg principal axis near to the heme normal.

Animals↗

Polyglutaraldehyde: a new reagent for coupling proteins to microspheres and for labeling cell-surface receptions. II. Simplified labeling method by means of non-magnetic and magnetic polyglutaraldehyde microspheres.

Procedures were developed for the synthesis of a new immunoreagent in form of polyglutaraldehyde (PGL) microspheres in sizes ranging from about 50 nm to 1.5 micron. Addition of fluorochromes during synthesis yielded microspheres of high fluorescence intensity. By carrying out the polymerization of glutaraldehyde in presence of iron oxide, magnetic PGL microspheres were produced. Antibody conjugates obtained by interaction of PGL microspheres with immunoglobulins were used to label human red blood cells (RBC) and lymphocytes. A simple method for the separation of magnetically labeled human RBC from unlabeled cells was demonstrated.

Aldehydes↗

Residue-specific assignments of resonances in the 1H nuclear magnetic resonance spectrum of ribosomal protein E-L30 by systematic application of two-dimensional Fourier transform nuclear magnetic resonance methods.

A two-dimensional Fourier transform nuclear magnetic resonance study of the ribosomal protein E-L30 is reported. Five two-dimensional techniques, namely: nuclear magnetic resonance J-resolved spectroscopy, correlated spectroscopy, double quantum spectroscopy, relayed coherence transfer and nuclear Overhauser enhancement spectroscopy were used. Qualitative inspection of the spectra obtained by these techniques provided evidence that the E-L30 molecule has a well-defined structure in solution. This analysis indicated that, despite the fact that the protein is stable only at moderate temperatures and neutral pH, a structural analysis of the molecule would be feasible. A detailed analysis of the spectra permitted unambiguous discrimination between the spin systems of different amino acids, resulting in residue-specific resonance assignments. We were able to assign all resonances of all six threonine, four valine, five alanine, two histidine, two serine, one phenylalanine, one asparagine and one aspartic acid residue of E-L30. Complete resonance assignment was obtained for two glycine residues. Partial assignments became available for all six isoleucine, three glycine and one glutamine residue. These results form a sound basis for the structure determination of the protein described in the accompanying paper.

Amino Acid Sequence↗

The electronic and magnetic properties of rubredoxin: a low-temperature magnetic circular dichroism study.

Oxidized rubredoxin from Clostridium pasteurianum has been investigated by magnetic circular dichroism (MCD) spectroscopy over the temperature range 1.5 to 150 K and at magnetic fields between 0 and 4.5 tesla. The results show that studies of the temperature and field dependence of MCD transitions afford insight into the polarization of electronic transitions for ground states with large g-value anisotropy, in addition to estimates of ground-state g values and zero-field splitting parameters. In agreement with the assignment made by Eaton and Lovenberg (Eaton, W.A. and Lovenberg, W. (1973) in Iron-Sulfur Proteins, Vol. II (Lovenberg, W., ed.), pp. 131-162, Academic Press, New York), the ultraviolet-visible spectrum of oxidized rubredoxin is assigned to two S----Fe(III) charge transfer transitions (both 6A1----6T2 under tetrahedral symmetry), each spanning a range of 650-430 nm and 430-330 nm, respectively. The observed splitting in each of these transitions is attributed to a predominant axial distortion in the excited state resulting in effective D2d symmetry.

Circular Dichroism↗

Magnetic resonance angiography of coronary arteries with a 3-dimensional magnetization-prepared true fast imaging with steady-state precession sequence compared with conventional coronary angiography.

BACKGROUND: The aim of the study was to compare the detection of clinically significant coronary artery stenosis using a magnetic resonance 3-dimensional (3D) breath-hold true fast imaging with steady-state precession (trueFISP) sequence with conventional coronary angiography. METHODS: Twenty-nine patients who were scheduled to undergo or had recently undergone diagnostic conventional coronary angiogram participated in this study. The left main, left anterior descending, left circumflex, and right coronary arteries were studied using the 3D breath-hold trueFISP technique. Each artery was imaged with 1 acquisition in 16 to 32 heartbeats. The image quality, vessel length, and presence or absence of stenosis were evaluated. A score of 1 to 3 (1 = noninterpretable, 2 = good, 3 = excellent) was used to assess image quality. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of magnetic resonance angiography in detecting significant coronary artery stenosis (> 50% luminal narrowing) on conventional coronary angiogram were calculated. RESULTS: Of 116 vessels, 108 were assessed in 29 patients. Twenty vessels that had image quality score of 1 were excluded from further evaluation. The mean lengths of vessels visualized were the following: left anterior descending 3.6 cm, left circumflex 3.4 cm, and right coronary 6.6 cm. The entire length of the left main coronary artery was visualized. For the visualized arterial segments, the sensitivity, specificity, accuracy, positive predictive value, and negative predictive value for detecting significant coronary artery stenosis were 92.8%, 95.3%, 95.0%, 68.4%, and 99.2%, respectively. CONCLUSIONS: The 3D breath-hold trueFISP technique, which uses the endogenous contrast of blood, is potentially useful in ruling out significant coronary artery stenosis but not yet sensitive enough as a screening tool.

Adult↗

Magnetic force microscopy analysis of apoptosis of HL-60 cells induced by complex of antisense oligonucleotides and magnetic nanoparticles.

Magnetic force microscopy (MFM) has been employed to observe antisense oligonucleotides (ASOs)-coupled silica-coated magnetic iron oxide nanoparticles (SMNPs) internalized into human leukemia (HL-60) cells. The experiment demonstrated that the ASOs-coupled SMNPs delivery into the cells really occurred. The nanoparticles were internalized into the cells and the apoptotic topography can be directly visualized simultaneously with MFM technology. These present observations offer direct morphology evidence on studying the apoptosis of tumor cells and provide useful information for better design of new diagnostic and therapeutic tools in tumor treatment.

Apoptosis↗

A real electro-magnetic placebo (REMP) device for sham transcranial magnetic stimulation (TMS).

OBJECTIVE: There is growing interest in neuropsychiatry for repetitive transcranial magnetic stimulation (rTMS) as a neuromodulatory treatment. However, there are limitations in interpreting rTMS effects as a real consequence of physiological brain changes or as placebo-mediated unspecific effects, which may be particularly strong in psychiatric patients. This is due to the fact that existing sham rTMS procedures are less than optimal. A new placebo tool is introduced here, called real electro-magnetic placebo (REMP) device, which can simulate the scalp sensation induced by the real TMS, while leaving both the visual impact and acoustic sensation of real TMS unaltered. METHODS: Physical, neurophysiological and behavioural variables of monophasic and biphasic single-pulse TMS and biphasic 1Hz and 20Hz rTMS procedures (at different intensities) were tested in subjects who were expert or naïve of TMS. Results of the real TMS were compared with those induced by the REMP device and with two other currently used sham procedures, namely the commercially available Magstim sham coil and tilting the real coil by 90 degrees . RESULTS: The REMP device, besides producing scalp sensations similar to the real TMS, attenuated the TMS-induced electric field (as measured by a dipole probe) to a biologically inactive level. Behaviourally, neither expert nor naïve TMS subjects identified the "coil at 90 degrees " or the "Magstim sham coil" as a real TMS intervention, whilst naïve subjects were significantly more likely to identify the REMP-attenuated TMS as real. CONCLUSIONS: The "goodness of sham" of the REMP device is demonstrated by physical, neurophysiological, and behavioural results. SIGNIFICANCE: Such placebo TMS is superior to the available sham procedures when applied on subjects naïve to TMS, as in case of patients undergoing a clinical rTMS trial.

Adult↗

Multi-dimensional magnetic resonance imaging in a stray magnetic field.

Stray field imaging has been extensively utilized in the last 10 years to perform very high resolution imaging of samples in a single dimension using the massive field gradient present in the fringe of a superconducting magnet. By spinning the sample around the magic-angle, the stray field gradient is successively reoriented along three orthogonal directions in the sample reference frame, allowing the acquisition of a full three-dimensional Fourier image, thereby providing the possibility to perform multi-dimensional very high-resolution imaging with standard nuclear magnetic resonance spectroscopy equipment. Here, we show multi-dimensional images demonstrating the feasibility of this technique.

Electromagnetic Fields↗

Efficient simulation of magnetic resonance imaging with Bloch-Torrey equations using intra-voxel magnetization gradients.

The process of image formation in magnetic resonance imaging (MRI) can be simulated by means of an iterative solution of Bloch-Torrey equations. This is a useful accessory to analyze the influence of sample properties, sequence parameters and hardware specifications on the MRI signal. In this paper, a computer algorithm is presented which is based on calculating partial derivatives of the magnetization vector. This technique allows more efficient simulation than summation of isochromats (the latter being commonly employed for this purpose) and, as a result, the effect of diffusion on the MRI signal can be calculated iteratively. A detailed description of the algorithm is given, and its feasibility for different applications is studied. It is shown that the algorithm is most applicable to simulating the effect of field perturbations, i.e. intra-voxel dephasing, but is also useful for other typical imaging experiments and the simulation of diffusion weighting.

Algorithms↗

Effects of static and radiofrequency magnetic field inhomogeneity in ultra-high field magnetic resonance imaging.

To characterize the severe static (B(0)) and radiofrequency (B(1)) magnetic field inhomogeneity in ultra-high field (> or =7 T) magnetic resonance imaging, gradient echo (GE) and spin echo (SE) images of in vivo and postmortem human brains were acquired. The B(0) and B(1) inhomogeneity were experimentally mapped and/or numerically simulated, and correlated with the image artifacts. Whereas B(0) inhomogeneity affects predominantly GE images near air/tissue interfaces, B(1) inhomogeneity affects SE images more severely and shows non-intuitive patterns. Mapping of the B(0) and B(1) inhomogeneity is important in characterizing image artifacts. This will help develop better B(0) and B(1) inhomogeneity correction methods.

Adult↗

Fast 3D coronary artery contrast-enhanced magnetic resonance angiography with magnetization transfer contrast, fat suppression and parallel imaging as applied on an anthropomorphic moving heart phantom.

A magnetic resonance sequence for high-resolution imaging of coronary arteries in a very short acquisition time is presented. The technique is based on fast low-angle shot and uses fat saturation and magnetization transfer contrast prepulses to improve image contrast. GeneRalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) is implemented to shorten acquisition time. The sequence was tested on a moving anthropomorphic silicone heart phantom where the coronary arteries were filled with a gadolinium contrast agent solution, and imaging was performed at varying heart rates using GRAPPA. The clinical relevance of the phantom was validated by comparing the myocardial relaxation times of the phantom's homogeneous silicone cardiac wall to those of humans. Signal-to-noise ratio and contrast-to-noise ratio were higher when parallel imaging was used, possibly benefiting from the acquisition of one partition per heartbeat. Another advantage of parallel imaging for visualizing the coronary arteries is that the entire heart can be imaged within a few breath-holds.

Contrast Media↗